Sunteți pe pagina 1din 4

Load Designation Equation Primary Load

U=1.4 D D
(405.31a)

U=1.2 D+1.6 L+0.5(LrR) L


(405.31b)

U=1.2 D+1.6 ( LrR ) +(1.0 L0.5 W ) Lr or R


(405.31c)

U=1.2 D+1.0 W +1.0 L+0.5 ( LrR ) W


(405.31d)

U=1.2 D+1.0E+1.0 L E
(405.31e)

U=0.9 D+1.0 W W
(405.31f)

U=0.9 D+1.0 E E
(405.31g)

SECTION 405: LOADS

Table 405.3.1 Load Combinations

(NSCP 2015, SECTION 405: LOADS)

SECTION 406: STRUCTURAL ANALYSIS

Table 406.3.2.1: Dimensional Limits for Effective Overhanging Flange


Width for T-Beams

Flange location Effective overhanging flange width, beyond face


of web
Each side of web Least of: 8h
s w /2

l n /8

One side of web Least of: 6h


s w /2

l n /12

(NSCP 2015, SECTION 406: STRUCTURAL ANALYSIS)


Table 406.5.2 Approximate Moments for Non-Prestressed Continuous
beams and One-Way Slabs

Moment Location Condition Mu


Discontinuous end w u l 2n /14
integral with support
End span
Discontinuous end w u l 2n /11
Positive unrestrained
All w u l 2n /16
Interior spans
Member built
integrally with w u l 2n /24
supporting spandrel
Interior face of
beam
exterior support Member built 2
integrally with w u l n /16
supporting column
Two spans w u l 2n / 9
Exterior face of
interior support More than two w u l 2n /10
spans
Face of other All 2
w u l n /11
supports
a) Slabs with
Negative
spans not
exceeding
3m.
b) Beams
where ratio
Face of all supports of sum of w u l 2n /12
satisfying (a) or (b) column
stiffness to
beam
stiffness
exceeds 8 at
each end of
span
ln
To calculate negative moments, shall be the average of the adjacent clear span lengths.

SECTION 407: ONE-WAY SLABS

Table 407.3.1.1 Minimum Thickness of Solid Non-Prestressed One-Way


Slabs

Support condition h(1 )


Minimum
Simply supported l/20
One end continuous l/24
Both ends continuous l/28
Cantilever l/10

[1] fy h
Expression applicable for normal weight concrete and = 420 MPa. For other cases, minimum shall be modified in accordance

with sections 407.3.1.1.1 through 407.3.1.1.3, as appropriate.

407.3.1.1.1 For
fy other than 420 MPa, the expressions in Table 407.3.1.1 shall be

multiplied by (0.4+ 700f ). y

Table 407.6.1.1 As,min for Non-Prestressed One-Way Slabs

Reinforcement f y , MPa As,min


type
Deformed bars <420 0.0020Ag
Deformed bars or 0.0018 420
Ag
welded wire >420 Greater of: fy
reiforcement
0.0014Ag

SECTION 408: TWO-WAY SLAB


[3] [3]
Without drop panels With drop panels
Exterior panels Interior Exterior panels Interior
panels panels
Without With edge Without With edge
[4] [4]
edge beams edge beams
beams beams
280 l n /33 l n /36 l n /36 l n /36 l n /40 l n /40

420 l n /30 l n /33 l n /33 l n /33 l n /36 l n /36

520 l n /28 l n /31 l n /31 l n /31 l n /34 l n /34

[1] ln
is the clear span in the long direction, measured face to face of supports (mm).

[2] fy
for between the values given in the table, minimum thickness shall be calculated by linear interpolation.

[3]
Drop panels as given in section 408.2.4.

[4] af
Slabs with beams between columns along exterior edges. The value of for the edge beam shall be calculated in accordance with

af
section 408.10.2.7. Exterior panels shall be considered to be without edge beams if is less than 0.8

Table 408.3.1.2 Minimum thickness of Non-Prestressed Two-Way Slabs with Beams


Spanning between Supports on All Sides
a fm [1]
Minimum h, mm
a fm 0.2 Section 408.3.1.1 applies (a)
fy
l n (0.8 )
1,400 (b)[2][3]
0.22<a fm 2.0 Greater of: 36 +5 ( afm0.2)

125 (c)
fy
l n ( 0.8 )
a fm >2.0 Greater of: 1,400 (d)[2][3]
36+9
90 (e)
[1] a fm is the average value of af for all beams on edges of a panel and
af

shall be calculated in accordance with Section 408.10.2.7.


[2] l n is the clear span in the long direction

S-ar putea să vă placă și