SRAM Restore:

FROM System Data Restore:


- Select 2.RESTORE SRAM" The following confirmation 1.) from the main menu select item 6. SYSTEM DATA
message is displayed. To start backup, press the [YES] LOADING.
2.) The menu of files stored on the Memory Card in the PCMCIA
FANUC
soft key.
Slot will be displayed Series 30*/31*/32*/35*
-Upon the termination of backup, the system displays the
3.) Use the [UP] [DOWN] soft keys to select the file to be loaded to
following message. Press the [SELECT] soft key.
the FROM(use the soft key to view the next page).
4.) Press the [SELECT] Soft Key.
SRAM Backup/Restore (Open System): 5.) When Prompted LOADING OK? press the [YES] Soft key.
1.) Select SRAM Tab
2.) Click on [Backup] button to store SRAM Image
6.) When Complete Press the [SELECT] key to go on.
System Backup
-Or FROM Data Backup/Restore (Open System):

Loader)
3.) Click on [Restore] button to retrieve SRAM Data
(Boot
Quick Reference

4.) FROM Data


FROM data are files stored in the CNCs internal Flash FROM Backup:
Memory. They include FANUC System Software, MTB 1.) Select the System Data tab on the screen shown above
Ladder Files, and MTB Custom Screen Files. 2.) Highlight the file to be saved
3.) To Backup Files press the [Save] button.
A limited Number of User Files may be backed up from the
Control Flash ROM. The following files may be backed up 4.) File will be saved to memory location.
to a memory card
FROM Restore:
1.) Select the System Data tab on the screen shown above.
2.) Press the [Load] key.
3.) a screen showing the contents of the Memory Card or the
selected storage device will appear.
4.) Highlight the file to be saved
5.) To load the Files press the [Load] button. Contents:
FROM System Data Save: 6.) File will loaded to the CNC FROM Memory.
1.) from the main menu select item 6. SYSTEM DATA I. Requirements ..2
SAVE NOTE: II. Activating Boot Loader
2.) The menu of files stored on the control Flash ROM will In Standard Control (non-Open) to exit any menu use the [UP] 1.) Standard CNC System...2
be displayed [DOWN] soft keys to select the END menu Item (if END does not 2.) Open CNC System .3
3.) Use the [UP] [DOWN] soft keys to select the file to be appear in the menu use the soft key to view the next page). III. System Backup
saved (use the soft key to view the next page).
1.) Description .....4
4.) Press the [SELECT] Soft Key. NOTE:
5.) When Prompted SYSTEM DATA SAVE OK? press the 2.) Main Menu ...4
Please refer the the FANUC Series 30i/31i/32i Maintenance Manual
[YES] Soft key. 3.) SRAM Data ..4
B-63945EN/03, Appendices C & F for further details
6.) When Complete Press the [SELECT] key to go on. 4.) FROM Data ..........................................5
5 6 1
2.) Entering Boot Loader With HSSB Open CNC III. System Backup
I. Requirements
1.) Description:
NOTE: The Boot Loader is used to backup Image of the user SRAM
Hardware Requirements: In an Open System CNC the Boot Loader can store information on (Static RAM ) Data and selected and selected files located in
a PCMCIA Flash Memory card or any storage device connected to the system FROM (Flash ROM)
-Standard Control the PC used as the primary display.
-Flash Memory Card =< 1 GIG max 2.) Main Menu Screen
- or
Start up:
- HSSB Open System
- PC with HSSB Board Mounted in PCI Slot 1.) Make Sure Power is off.
- or - 2.) Note Current Position of Rotary
- Ethernet switch.
- PC with Custom FOCAS2 VB Application 3.) Move Switch to the E position
(Very Uncommon and not covered here) 4.) Power Up the control
5.) The following screen should
appear:

II. Activating System Boot Loader 3.) SRAM Data

SRAM data is user data stored in the battery backed up


1.)Standard CNC System memory of the CNC. These utilities store the whole SRAM
image as a single file for backup. SRAM Data includes:
NOTE:
Programs, Offsets, Parameters, PMC Parameters, Macro
Boot Loader will only use a Flash Memory Card as a backup device.
Variables, etc
Mount the Flash Memory Card in the PCMCIA slot located just left of
SRAM Back up :
the LCD Display or in the slot on the Logic rack of a stand alone
type control
Press the [UP] or [DOWN] soft key to select the SRAM DATA
BACKUP function. After positioning the cursor to the desired
function, press the [SELECT] soft key. The following menu
will be displayed:

Selecting Back up File Destination:

Entering the Boot Loader: 1.) Click on the [ Settings } button and the following - Select "1.SRAM BACKUP" The following confirmation
message box should appear: message is displayed. To start backup, press the [YES]
Turn the power on CNC Control while simultaneously soft key.
pressing the two soft keys at the right end. - Upon the termination of backup, the system displays
the following message. Press the [SELECT] soft key.
NOTE:
If no soft keys are provided as with a touch panel, use MDI
numeric keys 6 and 7. CAUTION: Do not change the name of this file Control
2.) Select "Memory Card on CNC": Specify the memory will not recognize it by other name.
card slot of the CNC. CAUTION: Do not load this file to any other CNC
-Or except the one it came from, it will corrupt control
3.) Select Folder and use the Browse button to select a memory requiring a Service Call.
storage device connected to the PC.