Proc. of Int. Conf. on Advances in Civil Engineering 2012

Effect of Shear Wall Configuration on Seismic


Performance of Building
Ehsan Salimi Firoozabad1, Dr. K. Rama Mohan Rao2, Bahador Bagheri3
1.Post Graduate Student, Civil Engineering Department, JNTU Hyderabad, India
ehsansalimy.f@gmail.com
2.Professor and Head of Department, Civil Engineering Department, JNTU Hyderabad, India
rkunapareddy@yahoo.com
3. Post Graduate Student, Civil Engineering Department, JNTU Hyderabad, India
bahador_baghery@yahoo.com

AbstractOne of the most commonly used lateral load resisting (2000). Ref. [5] in Young-Hun Oh (2006) study, the level of
systems in buildings is shear wall system. It is well-established demands for deformation of shear walls was investigated
fact that shear walls are quite effective in seismic load using a displacement-based design approach.[6] R.K.L. Su
resistance of medium-rise to high-rise reinforced concrete (2008) reviews the seismic engineering research conducted
buildings. Shear walls have very high in-plane stiffness and
in Hong Kong with special emphasis on the prediction of
strength, which can be used simultaneously to resist large
horizontal loads and support gravity loads, making them quite seismic drift demand and capacity of existing buildings which
beneficial in seismic performance of buildings. Lot of have not been designed. [7] Kenneth A. Gent Franch (2008)
literature is available to design and analysis of shear wall; proposed the vulnerability index for masonry buildings was
the effect of different parameters such as: time period, wall modified to apply in confined masonry buildings and to obtain
density, slenderness ratio, on seismic behavior of shear wall a reasonable relationship with the wall density per unit floor
buildings has been studied as well. However, the decision about index. [8] the dynamic response of high rise structures under
the location of shear wall in multistory building and its effect the influence of discrete staggered shear walls has been
on performance against earthquakes is not much discussed in studied by B. Kameshwari (2011).
the literatures.
The main objective of the research work presented in this
In the present study main focus is to determine the effect of
shear wall configuration on seismic performance of buildings. paper is to study the seismic behavior of reinforced concrete
Time history analysis has been done to buildings with different shear wall buildings with respect to shear wall configurations.
number of stories and various configurations with same plan. Four buildings with same plan and different number of stories
The top story displacements have been obtained and compared (10, 15, 20, and 25) have been modeled considering six various
to each other for all models to meet the effect of shear wall shear wall configuration.[9] the criteria for structural
configuration on seismic performance of buildings. The performance of shear wall can be represented by the
analysis and design of models have been studied based on IS deformation demand inherent in the structure. The
codes, and SAP 2000 software have been used for this purpose.
displacement demand of buildings can be obtained when
these structures are submitted to real action of earthquake.
Index TermsShear wall configuration, Reinforced concrete
building, Seismic performance of building, Time history The ELCENTRO and TABAS earthquakes are used for this
analysis, Top story displacement purpose.

I. INTRODUCTION II. MODELING THE PROBLEM

Shear walls are vertical elements of the horizontal force Four buildings have been considered with same plan as
resisting system.[1] Shear walls are like vertically-oriented shown in figure 1 and different number of stories. Six different
wide beams that carry earthquake loads transfers to the configurations of shear wall are considered for all buildings.
foundation. Shear wall system is often used for resisting the The buildings are considered in zone V, with importance factor
lateral forces caused by seismic excitation, because of their of 1.5, response reduction factor of 5, and medium soil
high stiffness and strength.[2] Shear wall can be used condition. All loads such as: Dead, Live, and Earthquake
effectively for controlling the drift against seismic loads acting loads have been calculated and applied on building. Ref. [10]
on them.Mete A. Sozen (1989) is presented the critical the load combinations are considered based on IS 1893 and
structural parameters of shear wall building to relate drift the model has been analyzed and designed based on Indian
response to intensity of ground motion in an effort to answer Standard Codes using SAP 2000 software package.
design questions about the required amount of details and Shear wall configuration:
walls.[4] In order to evaluate seismic performance of confined Total six configurations have been considered for all
masonry buildings a methodology that compares buildings to evaluate the effect of shear wall configuration
displacement demands imposed by real earthquakes and their on seismic performance of building. Each configuration of
displacement capacities are proposed by Maximiliano Astroza shear walls is shown in different figure and named as shown
in fig [2-7].
2012 ACEE 121
DOI: 02.AETACE.2012.3. 7
Full Paper
Proc. of Int. Conf. on Advances in Civil Engineering 2012

Fig. 1. Base plan of buildings

Fig. 2. First shear wall configuration Fig. 3. Second shear wall configuration

Fig. 4. Third shear wall configuration Fig. 5. Fourth shear wall configuration

Fig. 6. Fifth shear wall configuration Fig. 7. Sixth shear wall configuration

III. DETERMINATION OF DISPLACEMENT DEMAND Earthquake Engineering Research Center.The top story
displacement of each building in X and Y direction with
The criteria for the structural performance of a shear wall
various configuration of shear wall is obtained and classified
can be represented by the deformation demand of structure.
for ELCENTRO and TABAS earthquake. The values have
The displacement demand of buildings can be obtained when
been read from one joint of roof level in both negative and
these structures are submitted to real action of earthquake
positive direction. So the largest value among those four
(time history analysis). The ELCENTRO and TABAS
values has been considered and given in table I, as maximum
earthquakes are used for this purpose. Ref. [11] these
displacement of building.
recorded accelerograms have been elicited from Pacific

2012 ACEE 122


DOI: 02.AETACE.2012.3.7
Full Paper
Proc. of Int. Conf. on Advances in Civil Engineering 2012

TABLE I. MAXIMUM TOP STORY DRIFT OF BUILDING

IV. CODE LIMITATION OF STORY DRIFT which are close to 1, indicates that the equations are accurate
According to IS1893, the story drift in any story due to to find maximum mean drift. The mean drift values shown in
the minimum specified lateral load shall not exceed 0.004 times fig [8-13] should be less than permissible drift based on IS
of story height. It means the maximum mean drift, which is 1983 which is 0.004 for each story. The maximum mean drift of
defined as top story drift divided by height of the building all buildings with various configurations under ELCENTRO
shall not exceed 0.004. The maximum mean drift to number of earthquake are less than 0.004. The results obtained from 25
story diagram is obtained for both earthquakes to do storey building show that, maximum mean drift is more than
comparison between the values of maximum mean drift and 0.004 in all shear wall configurations except sixth one. So, it is
code limitation. Also the equation of each trend line (based observed, although,those configurations is adequate for 10,
on the values of maximum mean drift correspond to the 15, and 20 storey building, but when the number of story
number of story) and corresponding correlation coefficients increasing those configuration may not satisfy the drift
is given; the correlation coefficient indicates the accuracy of limitation. The sixth configuration results are acceptable for
equation. The R square value is between zero (lowest all models. The maximum drift is 0.0038 in 25 stories building
accuracy) and one (highest accuracy). Hence the values which is less than 0.004. So the best shear wall position for

2012 ACEE 123


DOI: 02.AETACE.2012.3.7
Full Paper
Proc. of Int. Conf. on Advances in Civil Engineering 2012

this building, considering its plan is the sixth configuration. in lower number of storey buildings but, it satisfied the
However, the values are more than those in other positions limitation for all considering buildings.

Fig. 8. First shear wall configuration

Fig. 9. Second shear wall configuration

Fig. 10. Third shear wall configuration

Fig. 11. Fourth shear wall configuration

2012 ACEE 124


DOI: 02.AETACE.2012.3.7
Full Paper
Proc. of Int. Conf. on Advances in Civil Engineering 2012

Fig. 12. Fifth sear wall configuration

Fig. 13. Sixth shear wall configuration

CONCLUSIONS
Robust Walls Proceedings of Fifth Chilean Conference on
The study on the dynamic response of building with Seismology and Earthquake Eng., Santiago, 1989.
various shear wall configuration and their influence on [4] Maximiliano ASTROZA, Mara Ofelia MORONI and Carlos
seismic behavior of building is carried out and the top storey SALINAS Seismic Behavior Qualification Methodology For
drift for those configurations are obtained. From the study, Confined Masonry Buildings Proceedings of 12th World
the following conclusions have been made. Conference on Earthquake Engineering (12WCEE), Auckland,
1. Different position of shear walls can reduce the top N.Z, paper number 1123, 2000.
story drift at least twice, which means the drift of building is [5] Young-Hun Oh, Sang-Whan Han, and Yeoh-Soo Choi,
Evaluation and Improvement of Deformation Capacities of
reduced 100 percent from highest value to lowest one.
Shear Walls Using Displacement-Based Seismic Design
2. Maximum drift limitation of 0.004 as per IS code is International Journal of Concrete Structures and Materials
satisfied for all height of the building using ELCENTRO Vol.18, No.1E, pp.55-61, June 2006.
earthquake, whereas the above limitation is not satisfied by [6] R.K.L. Su, N.T.K. Lam, H.H. Tsang Seismic Drift Demand
TABAS earthquake. and Capacity of Non-Seismically Designed Concrete Buildings
3. For configuration sixth, the maximum drift limitation is In Hong Kong Journal Articles Refereed Electronic Journal
satisfied by both ELCENTRO and TABAS earthquakes, this of Structural Engineering, Vol. 8, pp. 110-120, 2008.
shows that, the location of shear walls plays major role for [7] Kenneth A. Gent Franch, Gian M. Giuliano Morbelli,
the limitation of drift. Maximiliano A. Astroza Inostroza, Roberto E. Gori, A seismic
vulnerability index for confined masonry shear wall buildings
4. The quantity of shear walls cannot guarantee the seismic
and a relationship with the damage Journal of engineering
behavior of buildings, which means, if you provide more shear structure, 30, pp. 2605-2612, 2008.
walls, it will not guarantee the better seismic behavior of [8] B. Kameshwari, G. Elangovan, p. Sivabala, G. Vaisakh
buildings. Dynamic Response Of High Rise Structures Under The
Influence Of Discrete Staggered Shear Walls International
REFERENCES journal of engineering science and technology, Vol 3, No 10,
October 2011.
[1] Najma Nainan, Dynamic Response of Seismo-resistant [9] Elisa Lumantarna, Nelson Lam, Bidur Kafle, JohnWilson,
Building Frames International Journal of Engineering Science Displacement Controlled Behaviour of Asymmetrical
and Technology (IJEST), Vol. 4 No.05, pp. 1865-1870, May Buildings Australian Earthquake Engineering Society
2012. Conference, 2008.
[2] Mete. A. Sozen Seismic Behavior of Reinforced Concrete [10] IS: 1893 (Part 1), 2002, Criteria for Earthquake Resistant
Building Chapter 13, CRC press LLC, 2004. Design of Structures general provisions and buildings, Bureau
[3] Sozen, M. A., Earthquake Response of Buildings with of Indian Standards, New Delhi.
[11] Pacific Earthquake Engineering Research Center (PEER): NGA
Database, http://peer.berkeley.edu/

2012 ACEE 125