A B C A B C A B C

A B C
9512 9512
9512 9512
4337 2850 1525 775 4337 2850 1525 775
4387 2825 1525 775 4387 2825 1525 775

1 1 1 1
WH 6
s2
s1-s2
a DEEP WELL
b
ACU
s1 s3w 5
SPO

EXISTING BUILDING

EXISTING BUILDING
EXISTING BUILDING

EXISTING BUILDING
TV

TV
EXISTING
7500

7500

7500

7500
7675
2-s2 EXISTING b
UP UP
2 2 2 2
s3w dn SPO
s3w up a
a
2-s2 4
1 3 2
s1
s1
DN d d DN
3 3 3 3

175
s3w
s1 s2,s3

GENSET
SECOND FLOOR

GROUND FLOOR GROUND FLOOR SECOND FLOOR

1 LIGHTING OUTLET LAYOUT


E-1 SCALE: 1:100 MTS
LIGHTING OUTLET BRANCH - CIRCUIT HOMERUN
2 POWER OUTLET LAYOUT
SERVICE ENTRANCE,
2-14 MM SQ. THW IN 1" DIA. E-1 SCALE: 1:100 MTS
RSC
PINLIGHT OUTLET PANEL BOARD

POWER SERVICE
ENT. WALL/POST LAMP OUTLET SERVICE ENTRANCE
230V,1,2W, 60 1. ALL ELECTRICAL WORKS HEREIN INCLUDED SHALL BE EXECUTED
HZ. ACCORDING TO THE REQUIREMENTS OF THE PHILIPPINE ELECTRICAL
CODE, THE RULES AND REGULATIONS OF THE SUBDIVISION, LOCAL
KW-HR METER
CL-100
M CONVENIENCE OUTLET CIRCUIT BREAKER GOVERNMENT AND THE REQUIREMENTS OF THE POWER
COMPANY, INEC.
MTS
60 AT 60 AT 2. COORDINATE WITH OTHER TRADES AND SPECIALTY WORKS CONTRACTORS FOR UP-TO-
SPECIAL PURPOSE OUTLET M SERVICE KW/HR METER DATE REQUIREMENTS ON RELATED ELECTRICAL WORKS INCLUDED HEREIN PRIOR TO
CUT OUT, GENSET SPO EXECUTION.
60 AT, 2P
S ONE GANG SWITCH U RISER UP
(ON NEMA 3R) 15 AT 15 AT 3. ALL FEEDERS AND BRANCH CIRCUITS SHALL BE INSTALLED AS INDICATED ON PLANS.
60 AT INDIVIDUAL BRANCH CIRCUIT HOMERUNS SHALL NOT BE COMBINED IN SAME RACEWAY
60 AT LO SPO
1 2 S2 TWO - GANG SWITCH D RISER DOWN UNLESS SO INDICATED.

4. LIGHTING BRANCH CIRCUITS WITHOUT DESIGNATION SHALL BE 2.0 MM THHN


SERVICE FEEDER, 15 AT 15 AT
S3 THREE - GANG SWITCH SWITCH HOMERUN CONVENIENCE OUTLET BRANCH CIRCUIT SHALL BE 2-3.5 MM THHN
2-14.0 MM SQ TW IN 1" DIA LO CO
uPVC 3 4
5. ALL CONDUCTORS ARE COPPER WITH 600V THHN INSULATION UNLESS NOTED
= 93.63 Amps. S3W THREE - WAY SWITCH LIGHTING LINE OTHERWISE. (PHELPS DODGE, PHILFLEX OR APPROVED EQUAL).
G 20 AT 20 AT
ACU WATER 6. ALL POWER WIRING SHALL BE IN UNPLASTICIZED POLYVINYL CONDUIT (PVC), UNLESS
5 6 HEATER S3W+S THREE - WAY & ONE WAY SWITCH IN POWER LINE OTHERWISE SPECIFIED. (NELTEX, VENDEX, EMERALD OR APPROVED EQUAL). GEN LUN
A STREET
A SINGLE SWITCH PLATE
7. ALL CONDUITS AND METAL FRAMES OF EQUIPMENT SHALL BE GROUNDED BY

PU
CONNECTING TO EQUIPMENT GROUNDING CONDUCTOR OR TO NEAREST WATER

RISER DIAGRAM ELECTRICAL SYMBOLS

ULA
SERVICE PIPE.
3 1-8.0 MM. SQ. TW IN 20 MM DIA. PVC
5

LIP
8. MOUNTING HEIGHTS OF DEVICES SHALL BE DETAILED ON THE PLANS, OR AS DETAILED
E-1 DRIVEN TO 20 MM. DIA. x 3.0M E-1 BY THE ARCHITECT AND OR AS FOLLOWS:

KA
COPPER CLAD GROUNDING ROD LOCAL SWITCHES - 1370 MM ABOVE FLOOR FINISH
RECEPTACLES - 300 MM ABOVE FLOOR FINISH JP RIZAL
COUNTERHEIGHT OUTLETS - 300 MM ABOVE BUILT-IN COUNTERS STREET
TYPE OF LOAD SWITCHES OTHER LOAD LOAD IN
BRANCH 9. COVER PLATES SHALL BE MODERN PLATES, TYPE AND COLOR SUBJECT TO ARCHITECTS
BRANCH CKT.
CKT NO VOLTS PHASE
PROTECTION
NO. AND SIZE OF WIRE AND CONDUIT ARROVAL. (NATIONAL, TOSHIBA OR APPROVED EQUAL) FREZ
RATING
LO CO S1 S2 S3 S3W TYPE
VOLT-AMP.
VOLT-AMP. AMP CARE
10. PANEL BOARD SHALL BE NEMA TYPE WITH NEMA 1 ENCLOSURE, PAINTED GI GAUGE #14
COMPLETE WITH CORROSION FREE HARDWARE SUCH AS HINGED DOOR, POLISH METAL A BONOFACIO ST.

EET
CATCH AND LOCK. PANELBOARDS SHALL CONTAIN A SINGLE BRAND OF MOLDED CASE,
GENSET 230V 1 60 AT CB 2 -14.0 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 8.0 SQ. MM. THHN GROUNDING "BOLT-ON" TYPE THERMAL MAGNETIC TRIP CIRCUITS BREAKERS (SQUARE D,

SITE

STR
WESTINGHOUSE,
G.E. OR APPROVED EQUAL). NUMBER AND SIZE OF CIRCUIT BREAKER SHALL BE AS SHOWN
1 6 2 2 1 230V 1 600VA 2.61A 15 AT CB 2 -2.0 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 2.0 SQ. MM. THHN GROUNDING

OLN
IN THE PANEL BOARD SCHEDULE.

11. FOR EXACT DIMENSIONS, REFER TO ARCHITECTURAL PLANS. DO NOT SCALE PLANS.

LINC
2 SPO 2000 230V 1 2000VA 8.70A 20 AT CB 2 -3.5 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 3.5 SQ. MM. THHN GROUNDING
12. CONTRACTOR TO PREPARE AS-BUILT PLAN AFTER THE COMPLETION OF THE PROJECT.
3 17 2 4 2 2 230V 1 1700VA 7.39A 15AT CB 2 -2.0 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 2.0 SQ. MM. THHN GROUNDING
13. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION
OF A
4 11 230V 1 1980VA 8.61A 20 AT CB 2 -3.5 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 3.5 SQ. MM. THHN GROUNDING DULY LICENSED ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.

5 ACU 1840 230V 1 1840VA 8.00A 20 AT CB 2 -3.5 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 3.5 SQ. MM. THHN GROUNDING

6
WATER
3500 230V 1 3500VA 15.22A 20 AT CB 2 -3.5 SQ. MM. THHN CU. WIRE, 20 MM PVC PIPE + 3.5 SQ. MM. THHN GROUNDING
6 ELECTRICAL NOTES
HEATER
E-1 SCALE: 1:100 MTS 7 VICINITY MAP
TOTAL 23 11 2 6 2 3 11,620VA 42.92A
E-1 SCALE: NTS.

COMPUTATION:

It = 11,620VA (.80) + 2.5 = 42.92 AMPERES USE 2 - 14.0MM THW CU. IN 1" RSC EXPOSED 4 SCHED. OF LOADS
230V PROVIDE 60AT, 2P, 250VAC MAIN DISCONNECT SWITCH WITH RAIN TIGHT BOX ENCLOSURE. E-1

R.A. 9266, ART.IV, SEC. 33 PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE OWNER SHEET NO.

OWNERSHIP OF PLANS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT


AS BUILT PLAN:
DRAWING AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED AND SEALED AS INSTRUMENT OF SERVICE ARE THE
INTELLECTUAL PROPERTY OF THE ARCHITECT WHETHER THE OBJECT WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR OF A TWO STOREY RESIDENTIAL E 1
ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF THE SAID DOCUMENTS FOR USED IN ANY REPITITION OF OTHER PROJECTS OR BUILDINGS
WHETHER EXECUTED PARTLY OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF THE ARCHITECTS OR AUTHOR OF THE SAID DOCUMENT. ALL PRC NO. VALIDITY MRS. EMERENCIANA GONZALES
ARCHITECT SHALL INCORPORATE THIS PROVISION IN ALL CONTRACT DOCUMENT AND OTHER INSTRUMENT OF SERVICE.
PTR NO. DATE:
5/5
PLACE TIN: LOCATION : BRGY. 27 NRA. SRA. de SOLEDAD, LAOAG CITY