1. Patrol inspection for material cutting of main lift padeye, there is no material identification on the padeye,
already inform the manufacturer and they promised to improve it.
1.2 Witness UT inspection at site, one area has problem and was marked, will be repaired by welding.Pi;e
No.:3568-C06-057.
1.3 Witness MT inspection for ancillaries at site, no findings and the result is accepted.
1.4 Conduct in-process inspection for production and installation of ancillaries, one findings is that the position of
opening on the pile is too close to the butt welds, this is not a reasonable practice, already instructed the worker at
site and they promised to improve it in the future and take this into consideration. Pile No.: 3568-C04-065, 3568-
C04-066, 3568-C05-067, 3568-C05-068.
Summary: The comments that I proposed are typical, and applicable to all of our products, but not just limited to
the products that I conduct actual inspection.