Sunteți pe pagina 1din 22

02 THE FUTURE IS UP KAI KEN BI 03

1958 marked the start of Panasonics venture


into creating air conditioners through cutting
THE edge technology.

FUTURE
Today, we bring you a quantum leap in design
and performance, creating a new standard for
how all air conditioners will be made.

IS UP Peerless design. Powerful cooling.


Perfect comfort.

THE PHILOSOPHY OF
CONTENT PANASONIC AIR CONDITIONER COMPANY
02 The Future Is Up 13 Backlit SKY Controller 24 At Panasonic, were constantly finding new ways
Technical Explanation
to improve your life. Our innovations bring you comfort
03 Kai Ken Bi 14 30 Model Line Up when you need it most, take care of your health and
ELITE Inverter Single-Split beautify your homes and lives.
PREMIUM Inverter Single-Split
Deluxe non-Inverter Single-Split
04 SKY STREAM DESIGN 16 Standard non-Inverter Single-Split
Technical Explanation

06 SKYWING 17 39 Features Explanation


Technical Explanation

08 RADIANT COOLING 19 + 40 Features Comparison

10 The Benefits of 22 42 Model Line Up BI


RADIANT COOLING
KAI KEN

12 COMFORT HEALTH BEAUTY


featuring DUST SENSOR
Essential air conditioner functions that Clean and fresh air that improves your Minimalist and modern air conditioners
cool you the way you want. health and wellbeing. that beautify your homes.
04 SKY STREAM DESIGN 05

SKY
STREAM
DESIGN
- FORM & FUNCTION UP

The SKY STREAM design embodies the elegance and pursuit


of perfection inherent in Japanese design philosophy.
Each timeless, precise line and feature creates
an unmistakable impression of premium luxury. Yet the
true power of its design is only revealed when it is switched on.

MODERN & MINIMALIST LINES MULTIDIRECTIONAL ARM SLIDING LED PANEL

Sleek and striking design Experience better agility When switched on, the
that makes it a luxurious through better control with Sliding LED Panel slides
complement to designer a multidirectional arm that open to reveal its setting
interior. adjusts cooling the way you indicators.
want it.

Remark: Applicable to ELITE Inverter only.


06 SKYWING 07

SKYWING
- FLEXIBILITY UP MULTIDIRECTIONAL ARM

The new SKYWING is set to create a new


standard in air conditioner design. Located
at the top, the SKYWING is better able to
direct cool air towards the ceiling. This cool
air naturally glides along the ceiling surface,
spreading throughout the room and down
the walls. Heat is removed from the ceiling
and walls, resulting in a feeling of even,
all-round coolness RADIANT COOLING.

Controlled by a Multidirectional Arm, the SKYWING can cool you two ways: VERSATILE COOLING COMFORT WITH SKYWING

RADIANT COOLING FAST COOLING At the touch of a button, the SKYWING tilts down for
you to enjoy Panasonics powerful and efficient Fast
Cooling whenever you need to cool down quickly.
Experience more powerful cooling from the
moment you switch on the air conditioner. Once the
room has reached the set temperature, the
SKYWING will adjust to RADIANT COOLING for
The SKYWING angles upwards to direct cool air The SKYWING angles downward to provide you fast continuous comfort.
towards the ceiling and walls, spreading cool cooling at start up. Together with the high-powered
air gently and evenly throughout the room. Inverter compressor technology, P-TECh, SKY Series
gives you extreme cool air with extra fast speed.

Remark: Applicable to ELITE Inverter only.


08 RADIANT COOLING 09

RADIANT
COOLING 2
1
- ALL-ROUND COOLING UP

Ceilings and walls tend to trap heat, which make living spaces 3
inside hot and uncomfortable. The solution was inspired by a
scientific principle called the Coanda Effect.

THE PRINCIPLE OF THE COANDA EFFECT

The Coanda Effect is the tendency of airflow


to be drawn to a surface and to flow along it.

RADIANT COOLING AIRFLOW ASSESSMENT Here is how RADIANT COOLING works:

AIRFLOW SMOKE TEST TEMPERATURE DISTRIBUTION TEST BOTTOM AIR INTAKE


4 3 2 1
The room is evenly Heat trapped in the Cool air is evenly Cool air is directed
cooled down. ceiling and walls distributed throughout towards the ceiling.
is removed. the room.
Instead of blowing cold CONVENTIONAL AIR RADIANT COOLING Hot air is drawn in from
air directly onto people, CONDITIONER the bottom, and cool air RADIANT COOLING cools without direct airflow.The feeling is just like walking into a mall.
the SKYWING directs the Cold air blows By cooling the ceiling discharged from the top
airflow upwards to cool downward, leaving and walls first, to facilitate the even
the ceiling and walls. some parts of the comfortable cooling distribution of cool air. Remark: Applicable to ELITE Inverter only.

room warmer and spreads evenly


others colder. across the room.
10 THE BENEFITS OF RADIANT COOLING 11

BENEFITS Conventional air conditioner SKY SERIES

OF
COOLS GENTLY AND EVENLY

The SKY Series makes the room evenly cool, even though no airflow feeling.
The cooling system of SKY Series gives comfort based on the principleof RADIANT COOLING.

RADIANT 28
27
26
25
24
It's comfortable!"
28
27
26
25
24 It's comfortable!"
The temperature in
all areas of the room
can be evenly set at
a comfortable level.

COOLING
23 23
Temperature 22 22
21 "It's cold!" 21
distribution 20 20
19 19
18 18
17 17
C C

Comfortable in living

- BENEFITS UP
Intake airflow Discharge airflow
space with no wind
DR NAOSHI KAKITSUBA "I feel cold wind!" "Its comfortable" (less than 0.2 m/s*)
Air velocity Comfort zone *Meter per second
DEPT. OF ENVIRONMENTAL distribution Discharge
airflow
SCIENCE AND TECHNOLOGY, Intake airflow

MEIJO UNIVERSITY JAPAN

Test conditions: Measured in stable operation at 25C cooling with fan speed set at "HI."
Conventional air conditioners are built to blow Inspired by the cooling effect of
cold air downwards and directly at people to cool caves, Doctor Naoshi Kakitsuba
them instantly. However, when in direct contact investigated the benefits of RADIANT COOLING REMOVES HEAT FROM CEILING AND WALLS
with cold air for too long, some people RADIANT COOLING. He found that
SKY Series makes people comfortable because the radiant heat from ceiling is less.
experience discomfort and dry skin. this gentler and more even cooling
method results in a greater feeling
Average Average
of comfort and wellbeing. ceiling temperature:
35C
ceiling temperature:
30C
Radiant heat
from roof top
and ceiling
Mean Radiant Temperature Mean Radiant Temperature
(Measure by Globe Thermometer) (Measure by Globe Thermometer)
Average 26.2C Average 26.2C
room temperature: room temperature:
25C 25C
The globe temperature is about 0.8C higher
(=About 1.1C higher in terms of how people feel comfortable)
The globe temperature is a composite temperature used to estimate the
effect of temperature, humidity, and solar radiation on humans.

THE
THE PRINCIPLE OF RADIANT PRINCIPLE OF RADIANT COOLING
COOLING Slightly
uncomfortable Slightly Comfortable
comfortable

20%
Sensation

100%
evaluation
Heat is absorbed by the breeze on the skin, Room
Temp.
Room
Temp.
resulting in a cool feeling. 25 C 25 C
Conventional Cooling Slightly comfortable Comfortable /
Slightly comfortable
Conventional air conditioner Neither or Slightly
any side comfortable

Measured in stable operation at 25C cooling with fan speed set at "MEDIUM."
The breeze directly contacts
The actual average room temperature is the same.
the body for cooling.

MAINTAIN SKIN MOISTURE AND PREVENTS DRY SKIN


Heat is absorbed by the cool surrounding
walls and ceiling, resulting in a cool feeling. Skin doesnt become dry even in a room with SKY Series operating.
RADIANT COOLING
SKY SERIES

71% 98%
Skin moisture 60 min. 60 min.

after
60 minutes
210S 150S 210S 206S
The breeze cools the walls and ceiling,
which absorb the body heat.

Measured in stable operation at 25C cooling with fan speed set at "HI."

Remark: Applicable to ELITE Inverter only. All test results are based on internal test.
12 nanoe-G & DUST SENSOR BACKLIT SKY CONTROLLER 13

SKY
featuring DUST SENSOR CONTROLLER
- HEALTH & WELLBEING UP
- VERSATILE CONTROL UP

SKY Series also features Panasonics advanced air The remote control has been
purification system, nanoe-G, which now comes with an redesigned for maximum ease of
innovative new DUST SENSOR. use and to complement the stylish
new design for SKY Series.
With simple and intuitive
controls, the Sky Controller
comes with various settings
that meet your everyday
air conditioning needs.

REMOVES DOWN TO PM2.5 AUTOMATED ACTIVATION BACKLIT LED SCREEN

nanoe-G releases negative ions which attach The DUST SENSOR automatically switches on The Sky Controller reveals its settings in a
to particles as small as PM2.5, the measuring nanoe-G to purify the air whenever a high level of better light thanks to the new backlit screen.
benchmark of air quality monitoring agencies. particle concentration is detected. Now you can adjust your settings without having
These particles are then brought back to the to switch on the lights.
positively-charged filter and removed from the air.
Please refer to page 24 - 25

CONSTANT AIR MONITORING DISTINCTIVE SLIDING COVER PRECISE TEMPERATURE CONTROL

The DUST SENSOR is constantly monitoring particle concentration levels in the room.

LED ACTIVITY LED ACTIVITY

DUST WHITE AIR IS CLEAN


DUST RED AIR IS DIRTY
SENSOR SENSOR

nanoe-G
nanoe-G OFF nanoe-G WHITE IS ACTIVATED
TO PURIFY THE AIR
A smooth sliding cover does not only enhance With the Sky Controllers 0.5C temperature control,
When particle concentration level is safe, the When particle concentration level is high, the the remotes clean lines, but keeps the buttons enjoy more precise temperature regulation and
indicator on the LED panel is white. indicator light turns red. nanoe-G switches free from dirt and smudges. experience greater comfort.
on to purify the air.

Remark: Applicable to ELITE Inverter only. Remark: Applicable to ELITE Inverter only.
14 iAUTO-X 15

P-TECh
FA S T
COOLING
- POWER & SPEED UP - HAPPINESS IS COMING HOME
TO FAST COOLING

On a hot day, feel the satisfaction of quick cooling that happens in an instant.
iAUTO-X provides powerful instant
cooling. Joining forces with fast,
high-powered inverter control through
the use of Panasonic Thermal
Enhancement Technology (P-TECh),
twin flaps direct the airflow for fast
cooling. Delivering this powerful cooling
airflow makes possible a 35% reduction
in the time required to reach the set
temperature.

The new Panasonic Thermal Enhancement AUTOMATIC FAN SPEED FASTER COOLING
Technology (P-TECh) enables the compressor iAUTO-X will automatically iAUTO-X cools you down 35% faster compared to

P-TECh to achieve maximum frequency in the shortest


time from start up. This lets you enjoy more
switch fan speed to high fan
speed and super high fan speed
Panasonic Standard non-Inverter model with high fan.

powerful cooling from the moment you switch depending on the temperature Room Temperature
on the air conditioner. difference between the room
35C
and the set temperature.

DASH & HIGH COMPRESSOR FREQUENCY PREMIUM Inverter with iAUTO-X

29C Standard non-Inverter model with


LOW SPEED
2015 Panasonic high fan
CY

HIGHEST FREQUENCY Quick


EQUEN

25C
Compressor Frequency (Hz)

Time
MAX FR

MEDIUM SPEED

2014 Panasonic
35 %*
O

PREMIUM STANDARD
DASH T

INVERTER NON-INVERTER
WITH iAUTO-X MODEL WITH
HIGH FAN SPEED HIGH FAN Faster Cooling
* Comparison of 1.5HP PREMIUM Inverter with iAUTO-X mode and
Standard non-Inverter model with cooling mode
PREMIUM Inverter: iAUTO-X Mode
iAUTO-X Mode, Outside Temperature: 35C /24C
Remote setting temperature: 25C with Fan Speed: Auto
Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight
SUPER HIGH FAN SPEED Standard non-Inverter: Cooling Mode with High Fan
COOL Mode, Outside Temperature: 35C /24C
Remote setting temperature : 25C with Fan Speed High
Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight

Remark: The time to reach the setting temperature was measured.


Applicable for PREMIUM Inverter with iAUTO-X warmer cooler At Panasonic Amenity Room (size: 16.6m) The effect differs
Time (min.) according to conditions in installation and usage.

Remark: P-TECh is applicable for ELITE Inverter and PREMIUM Inverter only. Remark: Applicable to PREMIUM Inverter only.
16 i A U TO - X T E C H N I C A L E X P L A N AT I O N i A U TO T E C H N I C A L E X P L A N AT I O N 17

SHOWER
COOLING
AEROWINGS features twin flaps Conventional air conditioners are built to blow
that give you more control over the cold air downwards and directly at people to cool
direction of the airflow. them instantly. However, when in direct contact
- COMFORT THAT GOES ON AND * Applicable to PREMIUM Inverter, Standard Inverter, - COOLING COMFORT with cold air for too long, some people
ON WITH SHOWER COOLING Standard non-Inverter & Semi Deluxe non-Inverter.
experience discomfort and dry skin.

After reaching the set temperature, Shower Cooling


directs airflow towards the ceiling to avoid direct cooling.
This helps distribute cool air evenly throughout the
room, giving you longer lasting comfort.

INNER FLAP

OUTER FLAP

Panasonic Air Conditioners with Aerowings feature an indoor design with wider intake
grille and super-high fan speed to produce bigger air volume.

FOR SHOWER COOLING BIGGER INTAKE HONEYCOMB INTAKE GRILLE

PKH (2014) SKT (2016)


TRUE COMFORT IS JUST A TOUCH AWAY
HOT AIR INTAKE MORE HOT AIR INTAKE

1. FAST COOLING AT START UP


214mm BIG INTAKE 236mm

FAN SPEED
2014 model iAUTO mode

At start up, iAUTO will run at super high fan speed to


HIGH SUPER HIGH* 35C 2013 cool mode with High Fan

cool the room faster, 15% faster for cooler comfort.

Room Temperature
29C
HOT AIR INTAKE Quick
2. MAINTAIN COOLING COMFORT
25C
Super High
High

Before you feel too cold and Panasonic Air Conditioners feature a New Honeycomb Intake Grille has a
Medium
Once the room cools down, iAUTO provides constant

Fan Speed
uncomfortable, AEROWINGS shifts new intake grille which is 22 mm wider opening to increase the suction Time cool airflow to maintain a comfortable level of relative
the airflow upwards to spread cool wider and improved indoor fan speed of hot air from the room so that the humidity, to stay cool and comfortable all day long.
air over a wider area. This ensures that goes up to a super-high fan room can be cooled faster. The
cool air is evenly distributed speed at start up. The new chassis stronger honeycomb structure also
throughout the room and you can design generates bigger air volume offers the air conditioner better 3. AUTOMATIC FAN SPEED
stay comfortable without that contributes to faster cooling. protection.
experiencing continuous direct iAUTO automatically switches fan speed to high and
cooling. super high fan speed depending on the temperature
difference between the room and the set temperature.

Remark: Applicable to PREMIUM Inverter only. Remark: Applicable to DELUXE Non Inverter & STANDARD Non Inverter only.
iAUTO TECHNICAL
18 E X P L A N AT I O N ECONAVI + INVERTER 19

SINE WAVE DRIVE

iAUTO utilises high efficient Sine Wave DC motor to


realise both powerful cooling and energy saving.
- ENERGY SAVING
SINE WAVE COMPARISONS

Sine Wave drive produces smooth wave


COOL. ECO. TOGETHER.
curves.This reduces power loss or energy waste.
Sine Wave (blue)
curves smoothly
compared to conventional
Conventional rectangle drive produces distortions
which results in power efficiency loss.
With ECONAVIs Human Activity Sensors and Panasonic INVERTERs
rectangle (grey)
alternating speed frequency, enjoy energy saving highs while
experiencing ultimate comfort.
ADVANTAGES OF SINE WAVE

1. EFFICIENCY UP EVEN AT
HIGH ROTATIONAL SPEED PER MINUTE (RPM) MOTOR EFFICIENCY DATA (EX. INDOOR UNIT)
80

Reduced current distortion enables fan motor to 75


start faster, run cooler and perform more efficiently

Efficiency (%)
70
even while running at super high fan speed to help
reduce power consumption. 65

60
300 500 700 900 1100 1300 1500

2. STABLE OPERATION Speed (r/min)

Legend: Sine Wave Conventional rectangle


Sine Wave regulates power voltage that is identical to
power supplied, ensuring consistent performance
and stable operation.

3. LOW VIBRATION

Motor loads runs smoother with low vibrations


resulting in quieter operation.

QUALITY CONTROL THROUGH SIMULATED LABORATORY TEST

Panasonic carried out testing at our own Environmental Testing Room which simulates a
standard living room condition. This makes it possible to ensure air conditioner operates at
optimum performance level under varying conditions.

Testing is done in a large space of 16.6m to simulate


size of actual living room. Indoor temperature is
150 SENSORS
measured using 150 sensors to get the average
THE PERFECT MATCH SAVES YOU
* Comparison of 1.5HP Inverter model with ECONAVI (with Dual
room temperature. This ensures accuracy of indoor 16.6m
Human Activity Sensor, Sunlight Sensor, and Temperature Wave)
FOR HOME LIVING MORE ENERGY ON and 1.5HP Standard non-Inverter (Cooling)
temperature data. FOR PEACE OF MIND Inverter with ECONAVI:

ECONAVI ON, Outside Temperature: 35C/24C

Remote setting temperature: 25C with Fan Speed High


* Comparison of 1.5HP Deluxe non-Inverter model with iAUTO mode and cooling mode ECONAVI and INVERTER is a Your Panasonic Air Horizontal Airflow direction: Step 3, Vertical Airflow direction:
iAUTO Mode
iAUTO Mode, Outside Temperature: 35C /24C
perfect match of energy Conditioner simply knows ECONAVI mode

Setting temperature goes up 2C in total, 1C controlled by ECONAVI


Remote setting temperature: 25C with Fan Speed: Auto
Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight
saving features that keeps air when to keep power usage activity level detection and another 1C controlled by ECONAVI light
intensity detection.
Cooling Mode with High Fan conditioning in your home at a minimum. So, you can Temperature Wave is ON
COOL Mode, Outside Temperature: 35C /24C
Remote setting temperature : 25C with Fan Speed High more efficient and rest and relax comfortably Standard non-Inverter without ECONAVI:
FASTER Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight Outside Temperature: 35C/24C
COOLING The cooling speed was calculated by measuring the time to reach the setting temperature.
comfortable throughout the at home knowing that you Remote setting temperature: 25C with Fan Speed High
At Panasonic Amenity Room (size: 16.6m)
The effect differs according to conditions in installation and usage.
day. can save energy. Horizontal Airflow direction: Step 3, Vertical Airflow direction: Straight

Total power consumption amount is measured for 2 hours under


stable operation. At Panasonic Amenity Room (size: 16.6m)

This is the maximum energy saving value, and the effect differs
according to conditions in installation and usage.

Remark: Applicable to DELUXE Non Inverter & STANDARD Non Inverter only. Remark: Applicable to PREMIUM Inverter only.
20 ECONAVI + INVERTER 21

ECONAVI SENSORS INVERTER


ECONAVI has two sensors; the Human Activity Sensor and the
A conventional non-INVERTER
Sunlight Sensor. Together, they monitor human location, movement, NON-INVERTER
air conditioner can only operate at
absence, and sunlight intensity to use energy more efficiently. Room Big temperature
temperature fluctuations
a constant speed which is
too powerful to maintain the
Set
temperature set temperature. Thus, it switches
the compressor on and off

Output power
repeatedly. This results in wider
temperature fluctuations leading
ON OFF ON OFF ON
to wasteful consumption of energy.
Time

Remark: Energy is wasted by switching


Legend: Output Power Temperature the compressor ON and OFF to
maintain the set temperature.

The Panasonic INVERTER


INVERTER
air conditioner varies the
Room Little temperature rotation speed of the compressor,
temperature fluctuations
providing a precise method of
maintaining the set temperature.
Thus, Panasonic INVERTER
air conditioners give you

Output power
Set temperature
exceptional energy saving
ON
performance while ensuring you
Time stay comfortable at all times.
Remark: Saves energy by varying the
Legend: Output Power Temperature rotation speed of the
compressor to maintain the
set temperature.

CONSTANT COMFORT
ECONAVI SAVES YOU ENERGY
BECAUSE IT SENSES: Precise temperature control with a wide power output range enables an INVERTER
air conditioner to meet different room occupancy levels thus ensuring constant comfort.

Whether its a sunny MAXIMUM POWER MEDIUM POWER MINIMUM POWER


Where you are. day or at night.
AREA SEARCH SUNLIGHT DETECTION

Adapts rhythmic
When you leave temperature control
the room. after detecting
low activity level. Compressor rotation speed: HIGH Normal condition Compressor rotation speed: SLOW
ABSENCE DETECTION TEMPERATURE WAVE
When required, the unit operates When not required, the unit operates at
at full power. low power to save energy.

When you are Power: 4.50kW Power: 3.50kW Power: 1.02kW


less active.
Graph shows the 1.5HP PREMIUM Inverter models wide power output range during cooling.
ACTIVITY DETECTION

Remark: Applicable to PREMIUM Inverter only.


22 nanoe-G 23

- AIR PURIFICATION

nanoe-G releases 3 trillion of fine particles to clean the air PURIFIES AIR IN YOUR HOME DOWN TO
in your home environment for fresher and cleaner living.
THE SMALLEST DETAIL

1 REMOVAL OF AIRBORNE PARTICLES


nanoe-G can effectively remove up to 99% of PM2.5*1 and
airborne particles*2 such as bacteria, viruses and mould.

1 AIRBORNE *1
&*2 Please refer to page 24 - 26

Remark:
* 3 trillion is the simulated
*
*
Removal of airborne particles, even number of nanoe-G fine

PM2.5, those smaller than 2.5 micrometers


particles
mentioned
under the
conditions. 2 DEACTIVATION OF ADHESIVE
Bacteria, Viruses
& Mould Removal in size (PM2.5).
Actual measured nanoe-G
fine particles at the centre
2
MICRO-ORGANISMS AND
of the room (13m ):100k/cc
calculated number of DEODORISATION OF ADHESIVE ODOURS
Airborne particles: nanoe-G fine particles in the
entire room assuming they
are evenly distributed.
nanoe-G particles are able to deactivate up to 99%*3 of
PM2.5
Bacteria Viruses Mould
bacteria, viruses and inhibit mould growth that settles
on surfaces around you. The odours adhered on the
Natural Ion Wind spreads curtains and sofa are deodorised.
nanoe-G fine particles
that are released from
the nanoe-G generator.
*3
Please refer to page 27

3 trillion* nanoe-G
fine particles released

3 IN-FILTER
from the generator.
3 IN-FILTER DEACTIVATION

*4
DEACTIVATION With In-Filter Deactivation, nanoe-G deactivates 99%*4 of
bacteria and viruses trapped inside the filter.
Bacteria & Viruses

Deactivates bacteria and viruses trapped


Deactivation
nanoe-G catches
airborne particles in the filter.
*4
Please refer to page 28 & 29

2 ADHESIVE Remark: Applicable to PREMIUM Inverter & DELUXE Non Inverter only.

Mechanism *3
Deactivates adhesive micro-organisms and
Odour Particle Bacteria & Viruses
deodorises adhesive odours.
Deactivation

nanoe-G
Strike Odour Particles Decompose and Remove Odour
24 nano e -G T E C H N I C A L E X P L A N AT I O N 25

SOURCES OF PM2.5
W H AT I S P M 2 . 5 ?
PM2.5 can be found suspended in the air, including dust, dirt, smoke and liquid droplets.
These fine particles come from man-made sources such as the combustion of fossil
"Particulate matter," also known as PM is made up of a fuels, open burning and industrial processes as well as natural ones, which include sea
number of components including extremely small particles and sprays and dust carried by strong winds.
liquid droplets. Sized at less than 2.5 micrometers (PM2.5),
these particles are said to pose health problems as they
can easily enter our lungs.

PM2.5 REMOVAL EFFICIENCY BASED ON TIME


POLLEN BACTERIA / FINE
MOULD PARTICLES SERIAL MEASUREMENT OF PM2.5 CONCENTRATION

PM2.5 2.0
Legend:

Air conditioner with nanoe-G

PM2.5 Concentration (mg/ m3)


1.8
1.6
1.4
DIAMETER 1.2 80 min 202 min
1.0
>10m <10m
<2.5m 0.8
90% removal 99% removal
0.6
0.4
0.2
0.0
0 30 60 90 120 150 180 210 240 270 300

Time Elapsed (min.)

PARTICLE SIZE COMPARISON

AIRBORNE

REMOVES
PARTICLE SIZE COMPARISON REMOVES
POLLEN
10m-100m
Size
(m)
Large
10m
99 %*1
PM2.5
99%*2
BACTERIA
VIRUSES
and MOULD
BACTERIA
1m-10m
* PM2.5 Removal was certified by FCG Research Institute, Inc * Airborne Removal was certified by Kitasato Research Center
2.5m for Environmental Science
Test Report no. : 25034
PM2.5 is found in PM2.5 : Cigarette Smoke (as PM2.5) KRCES-Bio. Test Report no. : 23_0182
Bacteria : Staphylococcus aureus (NBRC 12732)
Effectiveness is measured on 0.3m-2.5m. (Specific size only)
VIRUS Industrial Smoke
KRCES-Env. Test Report no. : 22_0008
Exhaust Gas This removal effect is not proven for all the airborne toxic substances.
0.001m-0.1m Virus : Escherichia coli phage (X-174 ATCC 13706-B1)
Haze All results are based on specific testing conditions. : Influenza (H1N1) 2009 Virus
Cigarette Smoke Small
All tests are not demonstrated under actual usage situation. KRCES-Env. Test Report no. : 23_0140
Mould : Penicillium pinophilum (NBRC 6345)
All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.
26 nano e -G T E C H N I C A L E X P L A N AT I O N 27

ADHESIVE
THE EFFECTIVENESS OF
ODOUR DEODORISATION: THE ODOUR ADHERED ON THE CURTAINS AND SOFA

5
Decrease in odour intensity by one level after 2 hours of operation.
AIRBORNE 4.17
4
DATA ON REMOVAL OF AIRBORNE BACTERIA WAS PRESENTED BY HARVARD SCHOOL OF PUBLIC HEALTH RESEARCHERS Test Subject: Adhesive smell of tobacco smoke
3.25
AT NANO-SYMPOSIUM AT KYOTO UNIVERSITY, 2012 Test Chamber: 20m 1 Level Down

Odour Intensity
Measurement Method: Six-level odour intensity indication method 3
Test report No.: 13-1204
2.25
In a large space of 40 m The effect after 100 minutes in a 40 m test space [about the size of a 10 tatami mat room], not the
2
Removal effect has been evaluated. effect in a space where actually used. Odour Intensity Degree of Smell
Natural AC with
1 Performance evaluation of a novel ionizer for air purification applications. Dr. S. Rudnick et al. 0 No odour Decay nanoe-G
Harvard School of Public Health, Environmental Health Nanoscience Lab. 1 Barely able to detect (detection threshold) 1
2 Able to recognise a smell, but weak (recognition threshold)
C/Co (Normalized spore concentration)

nanoe-G
0.1 3 Easily perceptible
A study of the removal effect of airborne bacteria by using an air-conditioner incorporating nanoe-G was 4 Strong
nanoe-G on
0
nanoe-G off carried out in a large space, and the results were presented at Nano-Symposium jointly held in 5 Very Strong
0.01
September 2012 by Harvard University and Kyoto University. Initial After 2 hours
1 log10 reduction

Experimental data Projection


Test methods: Bacteria removal method: Release of nanoe-G ions.
Target: Airborne bacteria, Test results: It is estimated that after three hours of operation the nanoe-G will
ADHESIVE
0.001
0 20 40 60 80 100 120 140 160 180
achieve 2.7 log10 reductions, ~ 1 log10 reduction more, as compared to without nanoe-G.
time (min)

TARGET SUBSTANCE EFFECTIVENESS TESTING TEST REPORT METHOD RESULT


SUBSTANCE NAME INSTITUTE NO

AIRBORNE The AC with nanoe-G was


99% inactivation after
Japan Food Test Report 24 hour operation of
Staphylococcus aureus operated in a test space (10m)
Bacteria 99% Research No. nanoe-G. (compared to
(NBRC 12732) and viable cells were counted by
Laboratories 11047933001-02 the original condition/
pour plate method.
ventilation mode)
TARGET SUBSTANCE EFFECTIVENESS TESTING TEST REPORT METHOD RESULT
SUBSTANCE NAME INSTITUTE NO nanoe-G was operated in a test 99% inactivation after
Japan Food Test Report box (90 Litre) and phage infectivity
Bacteriophage 120 minutes operation
Virus 99% Research No. titer was determined by plaque
The AC with nanoe-G was (Phi X 174 NBRC 103405) of nanoe-G. (compared
Laboratories 11073649001-02 technique.
Cigarette Smoke operated in a test room (23m) and 99% removal from the to non-operation)
FCG Research Test Report air after 202 minutes of
PM2.5 (as PM2.5) 99% the concentration of PM2.5 was
Institute, Inc No. 25034 operation.
measured by PM2.5 Digital Dust Cladosporium Inhibit Japan Food Test Report nanoe-G was operated in a test The growth of the
Indicator. Mould cladosporioides Mould Research No. box (1m) and colonies on the subject was inhibited.
(NBRC 6348) Growth Laboratories 11047937001-02 plate were counted. (>85% after 7 days)
Kitasato The AC with nanoe-G was
Research KRCES-Bio. operated in a test room (25m) and 99% removal from the The AC with nanoe-G was
Staphylococcus
Bacteria 99% Center for Test Report aerosol was collected and air after 150 minutes of operated in a test room (20m) and
aureus (NBRC 12732) Decrease in odour
Environmental No. 23_0182 bacterial count was calculated. operation. the deodorisation effect on a piece
Science Smell of tabacco Decrease by OMI ODOR-AIR Test Report intensity by one level
Odour of cloth impregnated with odour
smoke one level SERVICE Co.Ltd. No. 13-1204 after 120 minutes of
components of cigarette smoke
operation.
Kitasato The AC with nanoe-G was was evaluated using six-level
Research KRCES-Env. operated in a test room (25m) and 99% removal from the odour intensity indication method.
99% Center for Test Report airborne phages were collected air after 120 minutes of
Environmental No. 22_0008 and phage count of the collected operation. Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
Science air was calculated.
Escherichia coli phage
(X-174 ATCC 13706-B1)
Kitasato nanoe-G was operated in a test
Research KRCES-Env. chamber (200 Litre) and the 99% removal from the ADHESIVE ADHESIVE ODOURS
99% Center for Test Report phages were collected and phage air after 5 minutes of
Environmental No. 22_0008 count of the collected air was operation.
Science calculated.

nanoe-G was operated in a test


chamber (200 Litre) and the DEACTIVATES

99
influenza viruses were collected 99% removal from the

%*3
Virus and the virus titers were air after 5 minutes of
calculated by the Reed and operation. DEODORISES
Muench method.
ADHESIVE ODOUR
BACTERIA
Kitasato In view of health hazard associated with spatial distribution of and VIRUSES (TOBACCO SMELL)
Research KRCES-Env. Influenza (H1N1) 2009 virus, nanoe-G removal effectiveness
Influenza (H1N1) 2009 Test Report
99% Center for cannot be tested in large test room (25m). When tested in 200
virus
Environmental No. 22_0008 Litre chamber, nanoe-G was able to decrease Influenza (H1N1) INHIBITS MOULD GROWTH
Science 2009 virus (99%) when it was operated for 5 minutes.
Additionally when tested in larger test room (25m), nanoe-G
can remove 99.5% of Coli phage virus when operated for 120
minutes. It was validated that evaluation on the influenza virus
could be speculated from the results on the phage according * Adhesive Deactivation was certified by Japan Food Research Laboratories Adhesive odour deodorisation was certified by OMI ODOR-AIR SERVICE Co. Ltd.
to the test results in a 200 Litre test chamber. It appeared that
the air-conditioners in a larger test room (25m) would be able Test Report number : 11047933001-02 Test Report No. 13-1204
to remove the influenza virus as effectively as the phage. Bacteria : Staphylococcus aureus (NBRC 12732)
Test Report number : 11073649001-02 All results are based on specific testing conditions.
Kitasato Virus : Bacteriophage (Phi X 174 NBRC 103405) All tests are not demonstrated under actual usage situation.
The AC with nanoe-G was
Research KRCES-Bio. operated in a test room (25m) and 99% removal from the Test Report number : 11047937001-02
Penicillium pinophilum Test Report Mould : Cladosporium cladosporioides (NBRC 6348)
Mould 99% Center for aerosol was collected and fungal air after 90 minutes of
(NBRC 6345) No. 23_0140
Environmental spores count was calculated. operation.
Science All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.

Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
28 nano e -G T E C H N I C A L E X P L A N AT I O N 29

HOW DOES IN-FILTER DEACTIVATION

IN-FILTER TARGET
SUBSTANCE
SUBSTANCE
NAME
EFFECTIVENESS TESTING
INSTITUTE
TEST REPORT
NO
METHOD RESULT

DEACTIVATION Japan Food


The test piece impregnated with
Staphylococcus aureus was placed
on the filter of the Air Conditioner
indoor unit, and then nanoe-G was

WORK?
Staphylococcus aureus Test Report 99% of deactivation after
Bacteria 99% Research operated. After the test piece was
(NBRC 12732) No. 12037932001 2-hour nanoe-G operation.
Laboratories collected, viable cells were counted.
* test substance was placed on the 4
locations of the filter; upper/lower
right and upper/lower left.

The test piece impregnated with


Escherichia coli phage was placed
on the filter of the Air Conditioner
indoor unit, and then nanoe-G was
Japan Food 99% of deactivation after
Escherichia coli phage Test Report operated. After the test piece was
99% Research 2-hour nanoe-G operation.
(X-174 ATCC 13706-B1) No. 12014705001 collected, phage infectivity titer was
Laboratories determined.
* test substance was placed on the 4
locations of the filter; upper/lower
right and upper/lower left.
Virus
The test piece impregnated with
Average 90% on Influenza (H1N1) 2009 Virus was
placed on the filter of the Air Average 90% deactivation
filter (The Kitasato
KRCES-Virus Conditioner indoor unit, and then after 2-hour nanoe-G
percentage varies Research
Influenza (H1N1) 2009 Test Report nanoe-G was operated. After the test operation.
from 78.9% to 96.1% Center for
Virus No. 24_0013 piece was collected, virus infectivity (The percentage varies from
depending on its Environmental
titer was determined. 78.9% to 96.1%, depending
1. POWER OFF 2. FAN OPERATION location) Science on its location on filter)
* test substance was placed on the 4
locations of the filter; upper/lower
right and upper/lower left.
The air-conditioner first has to be The fan operation will run automatically
turned off. for 30 minutes with the flaps slightly
open to ensure the internal components
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
are dry and free from condensation.

Remark: Remark:
Main power must be switched on for the The 30-minute fan operation is only applicable when the
entire duration. unit has been operated in COOL /DRY mode.

IN-FILTER DEACTIVATION
Fan Operation : On
Flap : Flaps slightly open
nanoe-G LED : On
DEACTIVATES DEACTIVATES

99
AVERAGE
%*4
BACTERIA
and VIRUSES 9O% INFLUENZA
(H1N1)
2009 VIRUS
INHIBITS MOULD GROWTH

3. nanoe-G OPERATION 4. DEACTIVATION EFFECT *4 In-Filter Deactivation was certified by Japan Food Research In-Filter Deactivation was certified by Kitasato Research Center
Laboratories for Environmental Science
Test Report number : 12037932001 Test Report number : KRCES-Virus Test Report No. 24_0013
Natural Ion Wind spreads nanoe-G nanoe-G deactivates bacteria and viruses Bacteria : Staphylococcus aureus (NBRC 12732) Virus : Influenza (H1N1) 2009 Virus
Test Report number : 12014705001 All results are based on specific testing conditions.
particles that are released from the that are trapped in the filter within 2
Virus : Escherichia coli phage (-174 ATCC 13706-B1) All tests are not demonstrated under actual usage situation.
nanoe-G generator. hours.
All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.
Fan Operation : Off
Flap : Closed
nanoe-G LED : On

Remark: Depending on the Air Conditioners accumulated operation time, nanoe-G In-Filter Deactivation may be activated only once a day.
30 PRODUCT LINE-UP 31

Wall-Mounted : ELITE Single-Split Type

(CS-VS10SKH-1)

COOLING MODELS
CS-VS10SKH-1 | CS-VS13SKH-1 | CS-VS18SKH-1 Wireless
RADIANT COOLING DUST SENSOR

BACKLIT SKY CONTROLLER


(Random)

SPECIFICATIONS ( ): Outdoor Unit

MODEL (50Hz) CS-VS10SKH-1 CS-VS13SKH-1 CS-VS18SKH-1 CS-VS10SKH-1/ CS-VS18SKH-1

[CU-VS10SKH-1] [CU-VS13SKH-1] [CU-VS18SKH-1] Enjoy innovative design at your CS-VS13SKH-1

(min-max) Btu/h 9,550 (2,860-11,200) 12,500 (3,140-14,300) 17,700 (3,750-19,800)


fingertips with the new stylish and
Cooling Capacity
(min-max) kW 2.80 (0.84-3.28) 3.66 (0.92-4.20) 5.20 (1.10-5.80) sleek Backlit Sky Controller.
(min-max) Btu/hW 13.08 (12.71-12.44) 13.16 (12.08-12.12) 12.21 (12.93-11.72)
EER
(min-max) W/W 3.84 (3.73-3.64) 3.85 (3.54-3.56) 3.59 (3.79-3.43)
With fast access to key operations and
Voltage V 230
Electrical Data Running Current A 3.4 4.4 7.0
a smooth gliding cover revealing more
Power Input (min-max) W 730 (225-900) 950 (260-1,180) 1,450 (290-1,690) options, controlling your settings has
Moisture Removal
L/h 1.6 2.1 2.9 become simple and intuitive.
Pt/h 3.4 4.4 6.1 1 Backlit LED screen lets you view
operations status in the dark.
Air Circulation m/min. 10.5 12.0 13.4
(Indoor/Hi) ft/min. 370 425 475
With a width of 58.9mm and a height
2 Power Button.
Inside (Hi/Lo/S-Lo) (dB-A) 36/25/18 41/27/19 46/36/31 of 144.7mm, the Sky Controller fits
Noise
Outside (Hi) (dB-A) 47 48 49 comfortably into your hand. 3 iCOMFORT lets you come home to
1
mm 318 (230) 318 (230) 318 (230) fast cooling. Then enjoy continuous
Height
inch 12-17/32 (9-1/16) 12-17/32 (9-1/16) 12-17/32 (9-1/16) comfort with RADIANT COOLING
2
mm 950 (650) 950 (780) 950 (824) which avoids direct cooling.
Dimensions Width 3
inch 37-13/32 (25-19/32) 37-13/32 (30-23/32) 37-13/32 (32-15/32) 4
4 Press up or down to set the 5
mm 280 (511) 280 (511) 280 (511)
Depth temperature.
inch 11-1/32 (20-1/8) 11-1/32 (20-1/8) 11-1/32 (20-1/8)
kg 13 (21) 13 (29) 13 (33) 7
Net Weight 5 Toggles between RADIANT COOLING 6 8
lb 29 (46) 29 (64) 29 (73) (SHOWER) and Fast Cooling (DIRECT).
mm 6.35 9 10
Liquid Side
Refrigerant inch 1/4 6 Activates the nanoe-G even when
Pipe Diameter mm 9.52 12.70 the air conditioner is switched off.
Gas Side 11
inch 3/8 1/2
Chargeless Pipe Length m 7.5 10 7 Set the airflow.
Maximum Pipe Length m 15 30 12
Pipe Extension
Max Elevation Length m 5 20
8 Adjusts the fan speed.
Additional Refrigerant Gas* g/m 15
Power Supply Indoor
9 Toggles between COOL and DRY
Caution For CS-VS10/VS13/VS18SKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness. setting mode.
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

OUTDOOR
10 Delays off timer with temperature
control for better sleep.

11 Set the 24-hour ON & OFF Timer or


24-hour Dual ON & OFF Timer.
CU-VS10SKH-1 CU-VS13SKH-1 CU-VS18SKH-1

12 Set the actual time [hour and


minute].
32 PRODUCT LINE-UP 33

Wall-Mounted : Premium Single-Split Type

CS-S10SKH-1 | CS-S13SKH-1 | CS-S15SKH-1 Wireless

COOLING MODELS

CS-S18SKH-1 | CS-S24SKH-1 | CS-S28SKH-1 Wireless


C

EASY-TO-USE REMOTE
(Random) CS-S10SKH-1/

SPECIFICATIONS
CS-S13SKH-1/
( ): Outdoor Unit CS-S15SKH-1

CONTROLLER CS-S24SKH-1 CS-S18SKH-1/


MODEL (50Hz) CS-S10SKH-1 CS-S13SKH-1 CS-S15SKH-1 CS-S18SKH-1 CS-S24SKH-1 CS-S28SKH-1 CS-S28SKH-1

[CU-S10SKH-1] [CU-S13SKH-1] [CU-S15SKH-1] [CU-S18SKH-1] [CU-S24SKH-1] [CU-S28SKH-1]

Cooling Capacity
(min-max) Btu/h 9,550 (2,860-11,200) 12,500 (3,140-14,300) 15,000 (3,650-17,100) 18,000 (3,750-20,500) 21,300 (3,820-24,200) 24,200 (3,920-29,000)
Panasonics wireless remote
(min-max) kW 2.80 (0.84-3.28) 3.66 (0.92-4.20) 4.40 (1.07-5.00) 5.27 (1.10-6.00) 6.25 (1.12-7.10) 7.10 (1.15-8.50)

EER (min-max) Btu/hW 12.57 (12.71-12.17) 12.02 (12.08-11.92) 12.71 (12.81-12.57) 12.86 (12.93-12.06) 11.83 (11.58-11.00) 11.92 (11.20-10.74)
controller features a large Liquid
Voltage V 230 Crystal Display (LCD) panel which
Electrical Data Running Current A 3.6 4.8 5.4 6.5 8.2 9.3 makes it even more user-friendly. So
1 LCD display for an easy overview of
Power Input (min-max) W 760 (225-920) 1,040 (260-1,200) 1,180 (285-1,360) 1,400 (290-1,700) 1,800 (330-2,200) 2,030 (350-2,700)
you can sit back and enjoy easy the operation status.
L/h 1.6 2.1 2.4 2.9 3.5 4.1
Moisture Removal
Pt/h 3.4 4.4 5.1 6.1 7.4 8.7
operation and long-lasting comfort
2 Come home to fast cooling. Then
Air Circulation m/min. 10.1 10.9 12.8 17.7 18.1 18.4 from your Panasonic Air Conditioner. enjoy continuous comfort with Shower
(Indoor/Hi) ft/min. 355 385 450 625 640 650 Cooling which avoids direct cooling.
Inside (Hi/Lo/S-Lo) (dB-A) 36/26/22 38/28/25 43/30/27 44/32/29 45/34/31 47/37/34
Noise 3 ECONAVI monitors sunlight intensity,
Outside (Hi) (dB-A) 47 48 50 50 52 53
human movement, activity levels and 1
mm 296 (511) 296 (542) 296 (619) 296 (695) 296 (795)
Height human absence to detect and reduce
inch 11-21/32 (20-1/8) 11-21/32 (21-11/32) 11-21/32 (24-3/8) 11-21/32 (27-3/8) 11-21/32 (31-5/16) energy waste.
mm 870 (650) 870 (780) 1,070 (824) 1,070 (875)
Dimensions Width
inch 34-9/32 (25-19/32) 34-9/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32) 4 Activates the nanoe-G function even 2 3
mm 236 (230) 236 (289) 241 (299) 241 (320) when the air conditioner is switched
Depth off.
inch 9-5/16 (9-1/16) 9-5/16 (11-13/32) 9-1/2 (11-25/32) 9-1/2 (12-5/8) 5
6 4
Net Weight
kg 9 (20) 9 (27) 9 (31) 12 (36) 12 (43) 12 (57) 5 Press up or down to set the
lb 20 (44) 20 (60) 20 (68) 26 (79) 26 (95) 26 (126) temperature.
7 8
mm 6.35
Liquid Side
Refrigerant inch 1/4 6 Toggles between iAUTO-X, COOL and
Pipe Diameter mm 9.52 12.70 15.88
DUAL TIMER DRY setting mode. 10
Gas Side 9
inch 3/8 1/2 5/8
7 Delays off timer with temperature
Chargeless Pipe Length m 7.5 10 control for better sleep. 11
Maximum Pipe Length m 15 30 20 30
Pipe Extension
Max Elevation Length m 5 20 15 20 8 Set the airflow.
DUAL TIMER FOR 2 ON AND OFF TIMES PER DAY 12
Additional Refrigerant Gas* g/m 15 20 30

Power Supply 9 Adjusts the fan speed.


Indoor Outdoor For convenience, the dual timer repeats everyday
Caution For CS-S10/S13/S15/S18/S24/S28SKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
until you cancel it.
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
10 Quiet function allows you to sleep
comfortably at night.
OUTDOOR Select ON or OFF Timer
11 Set the 24-hour ON & OFF Timer or
24-hour Dual ON & OFF Timer.

CU-S13SKH-1 CU-S18SKH-1 CU-S24SKH-1 CU-S28SKH-1


CU-S10SKH-1 1 2 Cancel 1 2 Cancel 12 Set the actual time (hour and
CU-S15SKH-1
minute).

Set the time.

TIMER
34 PRODUCT LINE-UP 35

Wall-Mounted : Deluxe non-Inverter Single-Split Type

CS-V9RKH-1 | CS-V12RKH-1 Wireless

COOLING MODELS

CS-V18RKH-1 | CS-V24RKH-1 | CS-V28RKH-1 Wireless

SPECIFICATIONS EASY-TO-USE REMOTE


(Random) CS-V9RKH-1

( ): Outdoor Unit

CONTROLLER CS-V12RKH-1 CS-V18RKH-1/ CS-V28RKH-1


MODEL (50Hz) CS-V9RKH-1 CS-V12RKH-1 CS-V18RKH-1 CS-V24RKH-1 CS-V28RKH-1 CS-V24RKH-1

[CU-V9RKH-1] [CU-V12RKH-1] [CU-V18RKH-1] [CU-V24RKH-1] [CU-V28RKH-1]

9,210 12,000 18,200


Cooling Capacity
Btu/h 23,400 27,000
Panasonics wireless remote
kW 2.70 3.52 5.33 6.85 7.92
EER Btu/hW 11.1 9.7 9.8 9.9
controller features a large Liquid
Voltage V 230 Crystal Display (LCD) panel which
Electrical Data Running Current A 3.7 5.0 8.3 10.6 12.8 makes it even more user-friendly. So
830 1,080 1 LCD display for an easy overview of
Power Input W 1,870 2,400 2,730
you can sit back and enjoy easy the operation status.
L/h 1.6 2.0 2.9 3.9 4.6
Moisture Removal
Pt/h 3.4 4.2 6.1 8.2 9.7
operation and long-lasting comfort
Automatic Intelligence switches fan
Air Circulation m/min. 10.1 11.2 16.9 18.7 20.2 from your Panasonic Air Conditioner. 2
speed for faster cooling with just one
(Indoor/Hi) ft/min. 357 395 597 660 713 touch of a button.
Inside (Hi/Lo) (dB-A) 37/26 41/29 43/39 47/42 49/44
Noise
Outside (Hi) (dB-A) 48 50 55 57 56 ECONAVI monitors sunlight intensity,
3
mm 296 (511) 296 (542) 296 (619) 296 (695) 296 (750) human movement, activity levels and
Height 1
inch 11-21/32 (20-1/8) 11-21/32 (21-11/32) 11-21/32 (24-3/8) 11-21/32 (27-3/8) 11-21/32 (29-17/32) human absence to detect and reduce
mm 870 (650) 870 (780) 1,070 (824) 1,070 (875) energy waste.
Dimensions Width
inch 33-9/32 (25-19/32) 34-9/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32)
mm 236 (230) 236 (289) 241 (299) 241 (320) 241 (345) 4 Toggles between iAUTO, COOL, and 2 3
Depth DRY setting mode.
inch 9-5/16 (9-1/16) 9-5/16 (11-13/32) 9-1/2 (11-25/32) 9-1/2 (12-5/8) 9-1/2 (13-19/32)
5
kg 9 (25) 9 (30) 12 (34) 12 (52) 12 (56)
Net Weight 5 Prevents the room temperature from 4 6
lb 20 (55) 20 (66) 26 (75) 26 (115) 26 (123) getting too hot or too cold when you
mm 6.35 are sleeping.
Liquid Side 7
Refrigerant inch 1/4
Pipe Diameter Activates the nanoe-G function even 8
mm 9.52 12.70 15.88 6
Gas Side
inch 3/8 1/2 5/8 when the air conditioner is switched 9
off. 10
Chargeless Pipe Length m 7.5
Maximum Pipe Length m 10 15 25 30 Delays off timer with temperature
Pipe Extension 7
Max Elevation Length m 5 20 control for better sleep. 11
Additional Refrigerant Gas* g/m 10 20 30
Power Supply Indoor Outdoor 8 Adjusts the fan speed.
12
Caution For CS-V9/V12/V18/V24/V28RKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. 9 Set the airflow.

OUTDOOR
10 Adjusts the fan speed.

CU-V9RKH-1 CU-V12RKH-1 CU-V18RKH-1 CU-V24RKH-1 CU-V28RKH-1 11 Set the 24-hour ON & OFF Timer or
24-hour Dual ON & OFF Timer.

12 Set the actual time (hour and


** Not applicable for EER Label minute).
36 PRODUCT LINE-UP 37

Wall-Mounted : Standard non-Inverter Single-Split Type

CS-PV9SKH-1 | CS-PV12SKH-1 Wireless

COOLING MODELS

(Optional)

CS-PV18SKH-1 | CS-PV24SKH-1 | CS-PV28SKH-1 Wireless


(Random) CS-PV9SKH-1

SPECIFICATIONS ( ): Outdoor Unit EASY-TO-USE REMOTE CS-PV12SKH-1 CS-PV18SKH-1/ CS-PV28SKH-1

CONTROLLER
CS-PV24SKH-1

MODEL (50Hz) CS-PV9SKH-1 CS-PV12SKH-1 CS-PV18SKH-1 CS-PV24SKH-1 CS-PV28SKH-1


[CU-PV9SKH-1] [CU-PV12SKH-1] [CU-PV18SKH-1] [CU-PV24SKH-1] [CU-PV28SKH-1]

9,210 12,000 18,200


Cooling Capacity
Btu/h 23,400 27,000
Panasonics wireless remote
kW 2.70 3.52 5.33 6.85 7.92
EER Btu/hW 10.96 11.01 9.73 9.75 9.64
controller features a large Liquid
Voltage V 230 Crystal Display (LCD) panel which
Electrical Data Running Current A 3.7 5.0 8.3 10.6 13.0 makes it even more user-friendly. So
840 1,090
Power Input W 1,870 2,400 2,800
you can sit back and enjoy easy
L/h 1.6 2.0 2.9 3.9 4.6
Moisture Removal
Pt/h 3.4 4.2 6.1 8.2 9.7
operation and long-lasting comfort
Air Circulation m/min. 10.2 11.3 16.9 18.7 20.2 from your Panasonic Air Conditioner.
(Indoor/Hi) ft/min. 360 399 597 660 713
Inside (Hi/Lo) (dB-A) 38/26 41/29 43/39 47/42 50/46
Noise
Outside (Hi) (dB-A) 48 52 55 57
mm 290 (511) 290 (542) 290 (619) 290 (695) 290 (750)
Height
inch 11-7/16 (20-1/8) 11-7/16 (21-11/32) 11-7/16 (24-3/8) 11-7/16 (27-3/8) 11-7/16 (29-17/32)
mm 850 (650) 850 (780) 1,070 (824) 1,070 (875)
Dimensions Width
inch 33-15/32 (25-19/32) 33-15/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32)
mm 199 (230) 199 (289) 240 (299) 240 (320) 240 (345)
Depth
inch 7-27/32 (9-1/16) 7-27/32 (11-13/32) 9-15/32 (11-25/32) 9-15/32 (12-5/8) 9-15/32 (13-19/32)
kg 8 (25) 8 (30) 12 (35) 12 (52) 12 (56)
Net Weight
lb 18 (55) 18 (66) 26 (77) 26 (115) 26 (123)
mm 6.35
Liquid Side
Refrigerant inch 1/4
Pipe Diameter mm 9.52 12.70 15.88
Gas Side
inch 3/8 1/2 5/8
Chargeless Pipe Length m 7.5
Maximum Pipe Length m 10 15 25 30
Pipe Extension
Max Elevation Length m 5 20
Additional Refrigerant Gas* g/m 10 20 30
Power Supply Indoor Outdoor

Caution For CS-PV9/PV12/PV18/PV24/PV28SKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

OUTDOOR

CU-PV9SKH-1 CU-PV12SKH-1 CU-PV18SKH-1 CU-PV24SKH-1 CU-PV28SKH-1

** Not applicable for EER Label


38 PRODUCT LINE-UP 39

Wall-Mounted : Standard non-Inverter Single-Split Type


FEATURES EXPLANATION
COMFORT
RADIANT COOLING iAUTO
Cools the ceiling and walls first, providing continuous cooling comfort RADIANT COOLING
Automatic Intelligence switches fan speed for faster cooling with just one
without direct airflow. touch of a button.

iCOMFORT QUIET MODE


Wired Let you come home to fast cooling. Then enjoy continuous comfort
CS-SV9SKH-1 | CS-SV12SKH-1 (Included in the unit) with RADIANT COOLING which avoids direct cooling.

iAUTO-X SOFT DRY OPERATION MODE


Come home to fast cooling. Then enjoy continuous comfort with Starts with cooling to dehumidify, then provides continuous breeze at a
Shower Cooling which avoids direct cooling. low frequency to keep a room dry without much change to the
temperature.
ECONAVI
Detects and reduces waste for more energy savings. PERSONAL AIRFLOW CREATION
Vertical and horizontal airflow patterns can be combined as desired to
achieve optimum comfort, with operation possible by remote even from a
TEMPERATURE WAVE C
distance.
Rhythmic temperature-controlled pattern to save energy without
Wired sacrificing comfort.
AIRFLOW DIRECTION CONTROL (UP & DOWN)
CS-SV18SKH-1 | CS-SV24SKH-1 | CS-SV28SKH-1 (Included in the unit) AUTOCOMFORT
Detects high activity levels and adjusts cooling power
to improve comfort.
MANUAL HORIZONTAL AIRFLOW DIRECTION CONTROL
SLEEP MODE
SPECIFICATIONS ( ): Outdoor Unit Delays off timer with temperature control for better sleep. SLEEP

INVERTER CONTROL AUTOMATIC OPERATION MODE


MODEL (50Hz) CS-SV9SKH-1 CS-SV12SKH-1 CS-SV18SKH-1 CS-SV24SKH-1 CS-SV28SKH-1 Varies the rotation speed of the compressor for higher energy savings.
[CU-PV9SKH-1] [CU-PV12SKH-1] [CU-PV18SKH-1] [CU-PV24SKH-1] [CU-PV28SKH-1]

Btu/h 9,210 12,000 18,200 23,400 27,000 CLEANER AIR


Cooling Capacity
kW 2.70 3.52 5.33 6.85 7.92
nanoe-G ANTI-BACTERIAL FILTER
EER Btu/hW 10.96 11.01 9.73 9.75 9.64 nanoe-G works effectively on airborne particles including PM2.5, The Anti-Bacterial Filter combines three effects in one: anti-allergen,
adhesive and in-filter micro-organisms such as bacteria, viruses anti-virus and anti-bacteria protection to provide clean air.
Voltage V 230 and mould ensuring a cleaner living environment.
Electrical Data Running Current A 3.7 5.0 8.3 10.6 13.0 ODOUR-REMOVING FUNCTION
With this function, there's no unpleasant odor when the unit starts up.
Power Input W 840 1,090 1,870 2,400 2,800 DUST SENSOR That's because the fan remains off momentarily, while the source of the
Monitors particle concentration levels and turns on nanoe-G DUST SENSOR

L/h 1.6 2.0 2.9 3.9 4.6 odour inside the air conditioner is suppressed.
if levels are high.
Moisture Removal
Pt/h 3.4 4.2 6.1 8.2 9.7 The unit must be in cool or dry mode and the fan speed must be set to
automatic.
Air Circulation m/min. 10.2 11.3 16.9 18.7 20.2 ANTI-DUST COATING
Anti-dust coating prevents dust from accumulating on cross flow
(Indoor/Hi) ft/min. 360 399 597 660 713 fan by keeping it clean. REMOVABLE, WASHABLE PANEL
Inside (Hi/Lo) (dB-A) 38/26 41/29 43/39 47/42 50/46
Noise CONVENIENCE
Outside (Hi/S-Lo) (dB-A) 48 52 55 57

Height
mm 290 (511) 290 (542) 290 (619) 290 (695) 290 (750) 24-HOUR DUAL ON & OFF 24-HOUR ON & OFF
inch 11-7/16 (20-1/8) 11-7/16 (21-11/32) 11-7/16 (24-3/8) 11-7/16 (27-3/8) 11-7/16 (29-17/32) REAL SETTING TIMER REAL SETTING TIMER
This feature enables you to preset two different sets of start/stop The exact operating time (hour and minute) of the air conditioner can be
mm 850 (650) 850 (780) 1,070 (824) 1,070 (875) operation timer (hour and minute) within a 24-hour time frame.
Dimensions Width set in advance. From here on, the unit will operate in accordance to
inch 33-15/32 (25-19/32) 33-15/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32) these preset hours every day until the system is reset.
mm 199 (230) 199 (289) 240 (299) 240 (320) 240 (345)
Depth LCD WIRELESS REMOTE CONTROL WIRED REMOTE CONTROL
inch 7-27/32 (9-1/16) 7-27/32 (11-13/32) 9-15/32 (11-25/32) 9-15/32 (12-5/8) 9-15/32 (13-19/32)
kg 8 (25) 8 (30) 12 (35) 12 (52) 12 (56)
Net Weight
lb 18 (55) 18 (66) 26 (77) 26 (115) 26 (123) RELIABILITY
mm 6.35 RANDOM AUTO RESTART LONG PIPING
Liquid Side
Refrigerant inch 1/4
(Random)
Pipe Diameter mm 9.52 12.70 15.88
Gas Side BLUE FIN CONDENSER TOP-PANEL MAINTENANCE ACCESS
inch 3/8 1/2 5/8
Chargeless Pipe Length m 7.5
SELF-DIAGNOSTIC FUNCTION
Maximum Pipe Length m 10 15 25 30 Should a malfunction occur, the unit diagnoses the problem and
Pipe Extension shows the corresponding alphanumeric code. This allows for
Max Elevation Length m 5 20
quicker servicing.
Additional Refrigerant Gas* g/m 10 20 30
Power Supply Indoor Outdoor

Caution For CS-SV9/SV12/SV18/SV24/SV28SKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

OUTDOOR

CU-PV9SKH-1 CU-PV12SKH-1 CU-PV18SKH-1 CU-PV24SKH-1 CU-PV28SKH-1

** Not applicable for EER Label


40 F E AT U R E S C O M PA R I S O N & E X P L A N AT I O N 41

FEATURES COMPARISON

Split Type ELITE Inverter Premium Inverter Deluxe non-Inverter STANDARD non-Inverter STANDARD non-Inverter
Wall-Mounted

CS-VS10SKH-1 CS-S10SKH-1 CS-S18SKH-1 CS-V9RKH-1 CS-V18RKH-1 CS-PV9SKH-1 CS-PV18SKH-1 CS-SV9SKH-1 CS-SV18SKH-1


CS-VS13SKH-1 CS-S13SKH-1 CS-S24SKH-1 CS-V12RKH-1 CS-V24RKH-1 CS-PV12SKH-1 CS-PV24SKH-1 CS-SV12SKH-1 CS-SV24SKH-1
CS-VS18SKH-1 CS-S15SKH-1 CS-S28SKH-1 CS-V28RKH-1 CS-PV28SKH-1 CS-SV28SKH-1
Cooling Models

COMFORT

RADIANT COOLING Radiant Cooling

iComfort

iAUTO-X * Fast Cooling.


Refer to Page 6-7
ECONAVI

C Temperature Wave

AUTOCOMFORT

SLEEP SLEEP

Inverter Control

iAUTO

Quiet Mode

Soft Dry Operation Mode

Personal Airflow Creation

Airflow Direction Control (Up & Down)

Manual Horizontal Airflow Direction Control

Automatic Operation Mode (Cooling)

CLEANER AIR

nanoe-G

DUST SENSOR
Dust Sensor

Anti-Dust Coating

Anti-Bacterial Filter
(Optional) (Optional)
Odour-Removing Function

Removable, Washable Panel

CONVENIENCE

24-Hour Dual ON & OFF Real Setting Timer

24-Hour ON & OFF Real Setting Timer

LCD Wireless Remote Control

Wired Remote Control

RELIABILITY

Random Auto Restart (32 Restart Patterns)


(Random)

Blue Fin Condenser

Long Piping (Numbers indicate the maximum pipe length) 15m (VU10/13) 15m 20m (S24) 10m (V9) 25m (V18/V24) 10m (PV9) 25m (PV18/24) 10m (SV9) 25m (SV18/24)
30m (VU18) 30m (S18/28) 15m (V12) 30m (V28) 15m (PV12) 30m (PV28) 15m (SV12) 30m (SV28)
Top-Panel Maintenance Access

Self-Diagnostic Function
42 PRODUCT LINE-UP 43

MODEL LINE-UP
Horse Power (HP) 1.0 1.5 1.75 2.0 2.5 3.0

Capacity (Btu/h) 9,000 / 10,000 12,000 / 13,000 15,000 18,000 24,000 28,000
INVERTER DELUXE INVERTER DELUXE WIDE FEATURES

Wall-Mounted
ELITE
INVERTER
Page 30-31
CS-VS10SKH-1 CS-VS13SKH-1 CS-VS18SKH-1
(CU-VS10SKH-1) (CU-VS13SKH-1) (CU-VS18SKH-1)

(CS-VS10SKH-1)

INVERTER DELUXE INVERTER DELUXE WIDE FEATURES

Wall-Mounted
PREMIUM
INVERTER
Page 32-33
CS-S10SKH-1 CS-S13SKH-1 CS-S15SKH-1 CS-S18SKH-1 CS-S24SKH-1 CS-S28SKH-1
(CU-S10SKH-1) (CU-S13SKH-1) (CU-S15SKH-1) (CU-S18SKH-1) (CU-S24SKH-1) (CU-S28SKH-1)

STANDARD STANDARD WIDE FEATURES

Wall-Mounted
DELUXE
NON
INVERTER
CS-V9RKH-1 CS-V12RKH-1 CS-V18RKH-1 CS-V24RKH-1 CS-V28RKH-1
Page 34-35 (CU-V9RKH-1) (CU-V12RKH-1) (CU-V18RKH-1) (CU-V24RKH-1) (CU-V28RKH-1)

STANDARD STANDARD WIDE FEATURES

Wall-Mounted
STANDARD
NON
INVERTER
Page 36-37
CS-PV9SKH-1 CS-PV12SKH-1 CS-PV18SKH-1 CS-PV24SKH-1 CS-PV28SKH-1
(CU-PV9SKH-1) (CU-PV12SKH-1) (CU-PV18SKH-1) (CU-PV24SKH-1) (CU-PV28SKH-1)

STANDARD STANDARD WIDE FEATURES

Wall-Mounted
STANDARD
NON
INVERTER
Page 38 CS-SV9SKH-1 CS-SV12SKH-1 CS-SV18SKH-1 CS-SV24SKH-1 CS-SV28SKH-1
(CU-PV9SKH-1) (CU-PV12SKH-1) (CU-PV18SKH-1) (CU-PV24SKH-1) (CU-PV28SKH-1)

( ): Outdoor Unit Cooling Models

S-ar putea să vă placă și