Titrimetric Methods of Analysis

based upon measuring the amount of


reagent of known concentration (SR) that is
consumed by the analyte (A)
a A + b SR -- In c P

widely used for routine analyses because


they are rapid, convenient, accurate and
readily automated
Titrimetric Methods of Analysis

1. Volumetric Titrimetry involves measuring the volume of a


solution of known concentration
that is needed to react essentially
completely with the analyte

2. Gravimetric Titrimetry differs only in that mass of the


reagent is measured instead of its
volume

3. Coulometric Titrimetry the reagent is a constant direct


electrical current of known
magnitude that directly or indirectly
reacts with the analyte; the time
required to complete the
electrochemical reaction is
measured
Advantages of Weight Titrations

1. Calibration of glassware and tedious


cleaning to ensure proper drainage is
avoided.
2. Temperature corrections are unnecessary.
3. Weight measurement can be made with
considerably greater precision and
accuracy.
4. Weight titrations are more easily
automated.
Volumetric Titrimetry

Titration
performed by slowly adding
a standard solution from a Equivalence Point
buret to a solution of the amount T = amount A
analyte until the reaction
between the two is judged End Point - a physical
complete
change associated with the
volume of reagent needed to condition of chemical
complete the titration is equivalence occurs during
determined from the
difference between the titration
initial and final volume
readings Et = Veq - Vep
Volumetric Titrimetry

Indicator
often added to the analyte instruments to detect end
solution in order to give an points: voltmeters,
observable physical change ammeters, ohmmeters,
(the end point) at or near colorimeters, temperature
the equivalence point recorders and
refractometers
typical indicator changes:
appearance/disappearance weaker than the analyte,
of color, a change in color, kept at a minimum
appearance/disappearance amount, intensely colored
of turbidity and react last with the
titrant
Volumetric Titrimetry

Primary Standard Characteristics:

a highly purified high purity


compound that serves stability toward air
as a reference material absence of hydrate water
in all volumetric ready availability at
methods modest cost
accuracy of a method reasonable solubility in
is critically dependent the titration medium
on the properties of reasonably large molar
this compound mass
Volumetric Titrimetry

Secondary Standard Characteristics:

standard solution / be sufficiently stable


standard titrant react rapidly with the
analyte
a reagent of known
react more or less
concentration that is
completely with the
used to carry out a
analyte
titrimetric analysis
undergo a selective
expressed in terms of reaction with the
molarity and normality analyte
Methods for Establishing Concentration
of Standard Titrants

A. Direct Method B. Standardization

carefully weighed quantity 1. weighed quantity of a


of a primary standard is primary standard
dissolved in a suitable
solvent and diluted to an 2. measured volume of
exactly known volume in a another standard
volumetric flask solution/secondary
standard
Types of Titration Methods
1. Direct Titration 2. Indirect Titration
Method Method
titrant reacts directly Replacement Titration
with analyte/standard Method
employs a preliminary
a simple relationship
exist between the titrant reaction in which the
used and the analyte/standard is
analyte/standard replaced by an equivalent
present amount of another
substance which is then
determined by titration
Types of Titration Methods
3. Back-Titration
Chemical Equations:
Method
Residual Titration Method Direct Titration:
aA + bT In cP
a known excess of the
Indirect Titration:
titrant is added to the
aA + b R c NS
analyte/standard solution
d NS + e T In f P
amount of analyte is Back-Titration:
found by difference
aA + b T1 c P
excess
d T1 + e T2 In fP
excess
Classification of Volumetric Methods

1. Acid-Base 2. Precipitation

many compounds, both the titrant forms an insoluble


inorganic and organic, are product with the analyte
either acids or bases and can be
titrated with a standard indicators can be used to detect
solution of a strong base or a the end point or the potential of
strong acid the solution can be monitored
electrically
end points of these titrations
are easy to detect, either by
means of an indicator or by
following he change in pH with
a pH meter
Classification of Volumetric Methods

3. Complexometric 4. REDOX

the titrant is a reagent that involves the titration of an


forms a water-soluble complex oxidizing agent with a reducing
with the analyte, a metal ion agent or vice-versa

the titrant is often a chelating there must be a sufficiently


agent ; EDTA large difference between the
oxidizing and reducing
reverse titration may be carried capabilities
out also
end points detected by
indicators can be used to form appropriate indicators or by
a highly colored complex with various electrometric means
metal ion
Exercise 6
Assay of Table Wine
A 25.00-mL sample of Sample White Table Wine
white table wine was Analyte H2C4H4O6
diluted to about 100-mL
and titrated with 28.40- Indicator Phenolphthalein
mL of 0.05412-N NaOH Titrant NaOH
with phenolphthalein Method Volumetric Titrimetry
as indicator. Express the
Reaction Acid-Base Reaction
acidity of the wine in
terms of grams of Titration Direct Titration Method
tartaric acid Method
(H2C4H4O6) per 100 mL. Given:
25.00-mL sample
Molar Masses: 28.40-mL of 0.05412-N NaOH
H2C4H4O6 = 150.09 Answer: 0.4614 g /100 mL
NaOH = 40.00
Exercise 6

Standardization of HCl
Exactly 50.00-g of HCl Analyte HCl
required 29.71-g of Standard Ba(OH)2
0.01963-Mw Ba(OH)2 to Indicator Bromocresol Green
reach an end point with Method Weight Titrimetry
bromocresol green Reaction Acid-Base Reaction
indicator. Calculate the Type of Standardization & Titration Method
weight molarity of the Secondary Standardization
HCl solution. Direct Titration Method
Given:
Molar Masses: 50.00-g HCl
HCl = 36.46 29.71-g 0.01963-MW Ba(OH)2
Ba(OH)2 = 171.36 Answer: 0.02333-MW
Exercise 6
A sample of copper Assay of Copper Ore
ore weighing 2.132-g is Sample Copper Ore
dissolved in acid and Analyte Copper
the copper is Method Coulometric Titrimetry
electrolyzed: Reaction Redox Reaction
Cu 2+ + 2 e- Cu Given:
If 8.04-min is required 2.132-g sample
for the electrolysis using 8.04-min - 2.00A
a constant current of Answer: 14.9%
2.00-A, calculate the
percentage of copper
in the ore.
Molar Mass: Cu = 63.54