DESIGN BASIS REPORT FOR CW AND ACW SYSTEM

ANNEXURE-III

CW PIPE THICKNESS CALCULATION


(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 4.5 kgf/cm2
pressure
Allowable stress, SE : SE 1198 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 235Mpa).
Corrosion allowance A 1.5 mm.

Pipe OD considered Do 4040 mm.


159.06 inch
13.25 ft
Pipe ID calculated Di 4000 mm.
157.48 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 4040 mm.

Minimum wall thickness (tmin) to withstand the tmin 9.09 mm.


internal pressure : [(PxDo)/2xSE + A ]

Considering 12.5% manufacturing tolerance, 10.4 mm.


required thickness, trq =

Rounded off to, 11.0 mm.

Min. Wall thickness as per AWWA-M11, Eqn. 4- (D0+20)/400 11.4 mm


6,for pipe sizes greater than 54 inch
Minimum Wall thickness as per specification 12.0 mm

Increased steel shell thickness, t selected 20.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units

Maxm. Surge pressure to be kept within 1.4* Max Psurge 6.3 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure

### Checking Against Collapsing Pressure for aboveground installation


Not Applicable.

Page 1 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III

Page 2 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III

### Pipe Thickness Calculation for Buried Installation:


Description Formula Value Units
Increased thickness of steel pipe to meet the t 20.0 mm
buckling and deflection criteria, t :
0.787 inch
Pipe OD D0 4040 mm
159.06 inch
13.25 ft
Soil coverage on top of pipe as Considered h 1.250 m
4.10 ft
Unit weight. of filled soil as Considered wc 2 ton/m3
124.85 lb/ft3
Modulus of soil E' 1000 psi

Height of water surface above top of pipe (h w) : hw 1.25 m


Soil Load (Dead Load) on the pipe conduit
Soil Load(Wc) : wC x h x D 6786.80 lb/ft
Live Load(WL) : (Ref.Table:6-3 of AWWA M11) psf value 250 psf
hence WL = 3313.65 lb/ft
276.14 lb/inch.
Total load (W) per unit length of pipe : W=WC+WL 10100.44 lb/ft
841.70 lb/inch.

### Checking Against Deflection:


Horizontal deflection of pipe due to soil and truck loading (d x):
(Ref. Eq. 6-5 of AWWA M-11)
KWr 3
d x =D L
( )
EI +0 . 061 -----------------(Eq.
E' r 3 6-5)
Description Formula Value Units
Deflection lag factor, DL : 1.5
Bedding constant, K : 0.1
Load per unit of pipe length, W : 841.70 lb/inch
Outside radius of CW duct, r (=D/2) : 79.53 in
6.63 ft
Modulus of elasticity of pipe, Es = 30000000 psi

Modulus of soil, E' reaction:(assuming 1000 psi


moderate compaction of bedding)

Page 3 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III

Moment of inertia of cross section of pipewall, Is =I = 1 b t 3 0.04068 in4/in of pipe


12

Page 4 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III

Description Formula Value Units


Stiffness of steel shell (EsIs) EsIs 1220474.88 lb-inch
therefore dx1 = 1.9906 inch
(this must be within 5% of pipe dia if pipe is 1.25 % of OD
flexible lining and coated and calculated value
is=
[ Deflection Criteria: The deflection calculated as per eq.6-5 must be within 2% of pipe
dia if pipe is mortar-lined and coated, 3% of pipe dia if pipe is mortar-lined and
flexible coated, and 5 % of pipe dia if pipe is flexible lining and coated.]

Hence deflection is within allowable limit considering flexible lining and coate
### Checking Against Buckling:
Buckling Pressure Criteria:
(1) Buckling pressure due to live load and soil load must be < the allowable buckling
pressure calculated as per eq.6-7.
(2) Buckling pressure due to soil load and internal vacuum of pipe must be < the
allowable buckling pressure as per eq.6-7
Ref. eq.6-7 of AWWA M11
1 EI
Allowable buckling pressure (qa) :
q a =( )(32R w B'E' 3 )1/2--------Eq. (6-7)AWWA M11
FS D
Description Formula Value Units
FS=design factor : 2

Water buoyancy factor, Rw= 1-0.33x(hw / h) : 0.67


B'=empirical coefficient of elastic support 0.25
= 1/(1+4 X e^(-0.065h))
D=2r 159.06
Therefore, qa= 20.00 psi

### Condition-1 (considering the external loads as live load, dead load and water
buoyancy )
wC WL
q a1 = y w h w + R w +
D D
Buckling pressure due to live load WL/D 1.74 psi
As calculated below ywhw+RwWc/D 4.16 psi

Hence, buckling pressure, qa1 : 5.90 psi


(this must be less than the calculated allowable buckling pressure, i.e., q a1<qa
Hence, the actual buckling pressure is within the allowable limit.

Page 5 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III

5.2*Condition-2 (considering dead load, internal vacuum and water buoyancy *):
Ref. Eq. 6-8 of AWWA M11
Buckling pressure due to soil load and internal vacuum condition within pipe (q a2) :

wC
q a2= y w hw + R w + Pv
D ---------(Eq.6-8) AWWA M11

Description Formula Value Units


Specific weight of water, yw 0.0361 lb/cu. inch.
Height of water surface above pipe conduit, hw 49.21 inch.
Density of the pipe material as assumed, 7.85 ton/cu.m.
Soil Load on the pipe conduit, WC 565.57 lb/inch.
Hence ywhw+RwWc/D 4.16 psi
Considering 100% internal vacuum during Pv = 14.69 psi
transient condition
Hence, buckling pressure, qa2 : 18.85 psi
Allowable buckling pressure(psi), qa : 20.00 psi
Since qa >qa2
Hence, the actual buckling pressure is within the
allowable limit considering both type of allowable
buckling pressure
So the required steel pipe thickness to meet the buckling 20 mm
and deflection criteria is
*Since simultaneous application of live load and internal vacuum
transients need not normally be considered, the effect of live load has not
been taken into consideration here.

Page 6 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III_A

CW PIPE THICKNESS CALCULATION


(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 4.5 kgf/cm2
pressure
Allowable stress, SE : SE 1198 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 235Mpa).
Corrosion allowance A 1.5 mm.
Pipe OD considered Do 2840 mm.
111.81 inch
9.32 ft
Pipe ID calculated Di 2800 mm.
110.24 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 2840 mm.
Minimum wall thickness (tmin) to withstand the tmin 6.83 mm.
internal pressure : [(PxDo)/2xSE + A ]
Considering 12.5% manufacturing tolerance, 7.8 mm.
required thickness, trq =

Rounded off to, 8.0 mm.


Min. Wall thickness required as per AWWA-M11, (D0+20)/400 8.4 mm
Eqn. 4-6,for pipe sizes greater than 54 inch
Increased steel shell thickness, t selected 20.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units
Maxm. Surge pressure to be kept within 1.4* Max Psurge 0 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure

### Checking Against Collapsing Pressure for above ground installation

Description Formula Value Units


Increased steel shell thickness t 20.0 mm.
0.79 inch
Outside diameter of Pipe Do 111.81 inch
Pc=Collapsing pressure=50200000*(t/Do)^3 Pc 17.53 psi
Vaccum inside pipe Pv 14.69 psi
Pipe size is adequate

Page 7 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III_A

CW PIPE THICKNESS CALCULATION


(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 4.5 kgf/cm2
pressure
Allowable stress, SE : SE 1198 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 235Mpa).
Corrosion allowance A 1.5 mm.
Pipe OD considered Do 2536 mm.
99.84 inch
8.32 ft
Pipe ID calculated Di 2500 mm.
98.42 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 2536 mm.
Minimum wall thickness (tmin) to withstand the tmin 6.26 mm.
internal pressure : [(PxDo)/2xSE + A ]
Considering 12.5% manufacturing tolerance, 7.2 mm.
required thickness, trq =

Rounded off to, 8.0 mm.


Min. Wall thickness required as per AWWA-M11, (D0+20)/400 7.6 mm
Eqn. 4-6,for pipe sizes greater than 54 inch
Increased steel shell thickness, t selected 18.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units
Maxm. Surge pressure to be kept within 1.4* Max Psurge 0 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure

### Checking Against Collapsing Pressure for above ground installation

Description Formula Value Units


Increased steel shell thickness t 18.0 mm.
0.71 inch
Outside diameter of Pipe Do 99.84 inch
Pc=Collapsing pressure=50200000*(t/Do)^3 Pc 17.95 psi
Vaccum inside pipe Pv 14.69 psi
Pipe size is adequate

Page 8 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III_A

Page 9 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III_A

KWr 3
d x =D L
( EI +0 . 061 E' r 3 )

1 3
I= b t
12

Page 10 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III_A
1 3
I= b t
12

1 EI
q a =( )(32R w B'E' 3 )1/2
FS D

wC WL
q a1 = y w h w + R w +
D D

Page 11 of 39
DESIGN BASIS REPORT FOR CW AND ACW SYSTEM
ANNEXURE-III_A

wC
q a2= y w hw + R w + Pv
D

Page 12 of 39
CW PIPE THICKNESS CALCULATION
(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 4.5 kgf/cm2
pressure
Allowable stress, SE : SE 1198 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 235Mpa).
Corrosion allowance A 1.5 mm.

Pipe OD considered Do 3940 mm.


155.12 inch
12.93 ft
Pipe ID calculated Di 3900 mm.
153.54 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 3940 mm.
Minimum wall thickness (tmin) to withstand the tmin 8.90 mm.
internal pressure : [(PxDo)/2xSE + A ]

Considering 12.5% manufacturing tolerance, 10.2 mm.


required thickness, trq =

Rounded off to, 11.0 mm.


Min. Wall thickness as per AWWA-M11, Eqn. 4- (D0+20)/400 11.1 mm
6,for pipe sizes greater than 54 inch
Minimum Wall thickness as per specification 12.0 mm

Increased steel shell thickness, t selected 20.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units
Maxm. Surge pressure to be kept within 1.4* Max Psurge 6.3 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure
### Checking Against Collapsing Pressure for aboveground installation
Not Applicable.

### Pipe Thickness Calculation for Buried Installation:


Description Formula Value Units
Increased thickness of steel pipe to meet the t 20.0 mm
buckling and deflection criteria, t :
0.787 inch
Pipe OD D0 3940 mm
155.12 inch
12.93 ft
Soil coverage on top of pipe as Considered h 1.250 m
4.10 ft
Unit weight. of filled soil as Considered wc 2 ton/m3
124.85 lb/ft3
Modulus of soil E' 1000 psi
Height of water surface above top of pipe (h w) : hw 1.25 m
Soil Load (Dead Load) on the pipe conduit
Soil Load(Wc) : wC x h x D 6618.81 lb/ft
Live Load(WL) : (Ref.Table:6-3 of AWWA M11) psf value 250 psf
hence WL = 3231.63 lb/ft
269.30 lb/inch.
Total load (W) per unit length of pipe : W=WC+WL 9850.43 lb/ft
820.87 lb/inch.

### Checking Against Deflection:


Horizontal deflection of pipe due to soil and truck loading (d x):
(Ref. Eq. 6-5 of AWWA M-11)
KWr 3
d x =D L ( )
EI +0 . 061 -----------------(Eq.
E' r 3 6-5)
Description Formula Value Units
Deflection lag factor, DL : 1.5
Bedding constant, K : 0.1
Load per unit of pipe length, W : 820.87 lb/inch
Outside radius of CW duct, r (=D/2) : 77.56 in
6.46 ft
Modulus of elasticity of pipe, Es = 30000000 psi
Modulus of soil, E' reaction:(assuming 1000 psi
moderate compaction of bedding)
Moment of inertia of cross section of pipewall, Is = 1 3 0.04068 in4/in of pipe
I= bt
12
Description Formula Value Units
Stiffness of steel shell (EsIs) EsIs 1220474.88 lb-inch
therefore dx1 = 1.9355 inch
(this must be within 5% of pipe dia if pipe is 1.25 % of OD
flexible lining and coated and calculated value
is=
[ Deflection Criteria: The deflection calculated as per eq.6-5 must be within 2% of pipe
dia if pipe is mortar-lined and coated, 3% of pipe dia if pipe is mortar-lined and
flexible coated, and 5 % of pipe dia if pipe is flexible lining and coated.]

Hence deflection is within allowable limit considering flexible lining and coate
### Checking Against Buckling:
Buckling Pressure Criteria:
(1) Buckling pressure due to live load and soil load must be < the allowable buckling
pressure calculated as per eq.6-7.
(2) Buckling pressure due to soil load and internal vacuum of pipe must be < the
allowable buckling pressure as per eq.6-7
Ref. eq.6-7 of AWWA M11
Allowable buckling pressure (qa) : 1 EI
q a =( )(32R w B'E' 3 )1/2--------Eq. (6-7)
AWWA M11
FS D
Description Formula Value Units
FS=design factor : 2
Water buoyancy factor, Rw= 1-0.33x(hw / h) : 0.67
B'=empirical coefficient of elastic support 0.25
= 1/(1+4 X e^(-0.065h))
D=2r 155.12
Therefore, qa= 20.77 psi
### Condition-1 (considering the external loads as live load, dead load and water
buoyancy )
wC WL
q a1 = y w h w + R w +
D D
Buckling pressure due to live load WL/D 1.74 psi
As calculated below ywhw+RwWc/D 4.16 psi

Hence, buckling pressure, qa1 : 5.90 psi


(this must be less than the calculated allowable buckling pressure, i.e., q a1<qa
Hence, the actual buckling pressure is within the allowable limit.
5.2 Condition-2 (considering dead load, internal vacuum and water buoyancy *):
Ref. Eq. 6-8 of AWWA M11
Buckling pressure due to soil load and internal vacuum condition within pipe (q a2) :

wC
q a2= y w hw + R w + Pv
D ---------(Eq.6-8) AWWA M11

Description Formula Value Units


Specific weight of water, yw 0.0361 lb/cu. inch.
Height of water surface above pipe conduit, hw 49.21 inch.
Density of the pipe material as assumed, 7.85 ton/cu.m.
Soil Load on the pipe conduit, WC 551.57 lb/inch.
Hence ywhw+RwWc/D 4.16 psi
Considering 100% internal vacuum during Pv = 14.69 psi
transient condition
Hence, buckling pressure, qa2 : 18.85 psi
Allowable buckling pressure(psi), q a : 20.77 psi
Since qa >qa2
Hence, the actual buckling pressure is within the
allowable limit considering both type of allowable
buckling pressure
So the required steel pipe thickness to meet the buckling 20 mm
and deflection criteria is
*Since simultaneous application of live load and internal vacuum
transients need not normally be considered, the effect of live load has not
been taken into consideration here.
/in of pipe
CW PIPE THICKNESS CALCULATION
(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 4.5 kgf/cm2
pressure
Allowable stress, SE : SE 1198 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 235Mpa).
Corrosion allowance A 1.5 mm.

Pipe OD considered Do 2828 mm.


111.34 inch
9.28 ft
Pipe ID calculated Di 2800 mm.
110.24 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 2828 mm.
Minimum wall thickness (tmin) to withstand the tmin 6.81 mm.
internal pressure : [(PxDo)/2xSE + A ]

Considering 12.5% manufacturing tolerance, 7.8 mm.


required thickness, trq =

Rounded off to, 8.0 mm.


Min. Wall thickness as per AWWA-M11, Eqn. 4- (D0+20)/400 8.3 mm
6,for pipe sizes greater than 54 inch
Minimum Wall thickness as per specification 12.0 mm

Increased steel shell thickness, t selected 14.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units
Maxm. Surge pressure to be kept within 1.4* Max Psurge 6.3 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure
### Checking Against Collapsing Pressure for aboveground installation
Not Applicable.

### Pipe Thickness Calculation for Buried Installation:


Description Formula Value Units
Increased thickness of steel pipe to meet the t 14.0 mm
buckling and deflection criteria, t :
0.551 inch
Pipe OD D0 2828 mm
111.34 inch
9.28 ft
Soil coverage on top of pipe as Considered h 1.250 m
4.10 ft
Unit weight. of filled soil as Considered wc 2 ton/m3
124.85 lb/ft3
Modulus of soil E' 1000 psi
Height of water surface above top of pipe (h w) : hw 1.25 m
Soil Load (Dead Load) on the pipe conduit
Soil Load(Wc) : wC x h x D 4750.76 lb/ft
Live Load(WL) : (Ref.Table:6-3 of AWWA M11) psf value 250 psf
hence WL = 2319.55 lb/ft
193.30 lb/inch.
Total load (W) per unit length of pipe : W=WC+WL 7070.31 lb/ft
589.19 lb/inch.

### Checking Against Deflection:


Horizontal deflection of pipe due to soil and truck loading (d x):
(Ref. Eq. 6-5 of AWWA M-11)
KWr 3
d x =D L ( )
EI +0 . 061 -----------------(Eq.
E' r 3 6-5)
Description Formula Value Units
Deflection lag factor, DL : 1.5
Bedding constant, K : 0.1
Load per unit of pipe length, W : 589.19 lb/inch
Outside radius of CW duct, r (=D/2) : 55.67 in
4.64 ft
Modulus of elasticity of pipe, Es = 30000000 psi
Modulus of soil, E' reaction:(assuming 1000 psi
moderate compaction of bedding)
Moment of inertia of cross section of pipewall, Is = 1 3 0.01395 in4/in of pipe
I= bt
12
Description Formula Value Units
Stiffness of steel shell (EsIs) EsIs 418622.88 lb-inch
therefore dx1 = 1.3934 inch
(this must be within 5% of pipe dia if pipe is 1.25 % of OD
flexible lining and coated and calculated value
is=
[ Deflection Criteria: The deflection calculated as per eq.6-5 must be within 2% of pipe
dia if pipe is mortar-lined and coated, 3% of pipe dia if pipe is mortar-lined and
flexible coated, and 5 % of pipe dia if pipe is flexible lining and coated.]

Hence deflection is within allowable limit considering flexible lining and coate
### Checking Against Buckling:
Buckling Pressure Criteria:
(1) Buckling pressure due to live load and soil load must be < the allowable buckling
pressure calculated as per eq.6-7.
(2) Buckling pressure due to soil load and internal vacuum of pipe must be < the
allowable buckling pressure as per eq.6-7
Ref. eq.6-7 of AWWA M11
Allowable buckling pressure (qa) : 1 EI
q a =( )(32R w B'E' 3 )1/2--------Eq. (6-7)
AWWA M11
FS D
Description Formula Value Units
FS=design factor : 2
Water buoyancy factor, Rw= 1-0.33x(hw / h) : 0.67
B'=empirical coefficient of elastic support 0.25
= 1/(1+4 X e^(-0.065h))
D=2r 111.34
Therefore, qa= 20.00 psi
### Condition-1 (considering the external loads as live load, dead load and water
buoyancy )
wC WL
q a1 = y w h w + R w +
D D
Buckling pressure due to live load WL/D 1.74 psi
As calculated below ywhw+RwWc/D 4.16 psi

Hence, buckling pressure, qa1 : 5.90 psi


(this must be less than the calculated allowable buckling pressure, i.e., q a1<qa
Hence, the actual buckling pressure is within the allowable limit.
5.2 Condition-2 (considering dead load, internal vacuum and water buoyancy *):
Ref. Eq. 6-8 of AWWA M11
Buckling pressure due to soil load and internal vacuum condition within pipe (q a2) :

wC
q a2= y w hw + R w + Pv
D ---------(Eq.6-8) AWWA M11

Description Formula Value Units


Specific weight of water, yw 0.0361 lb/cu. inch.
Height of water surface above pipe conduit, hw 49.21 inch.
Density of the pipe material as assumed, 7.85 ton/cu.m.
Soil Load on the pipe conduit, WC 395.90 lb/inch.
Hence ywhw+RwWc/D 4.16 psi
Considering 100% internal vacuum during Pv = 14.69 psi
transient condition
Hence, buckling pressure, qa2 : 18.85 psi
Allowable buckling pressure(psi), q a : 20.00 psi
Since qa >qa2
Hence, the actual buckling pressure is within the
allowable limit considering both type of allowable
buckling pressure
So the required steel pipe thickness to meet the buckling 14 mm
and deflection criteria is
*Since simultaneous application of live load and internal vacuum
transients need not normally be considered, the effect of live load has not
been taken into consideration here.
/in of pipe
CW PIPE THICKNESS CALCULATION
(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 4.5 kgf/cm2
pressure
Allowable stress, SE : SE 1198 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 235Mpa).
Corrosion allowance A 1.5 mm.

Pipe OD considered Do 2728 mm.


107.40 inch
8.95 ft
Pipe ID calculated Di 2700 mm.
106.30 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 2728 mm.
Minimum wall thickness (tmin) to withstand the tmin 6.62 mm.
internal pressure : [(PxDo)/2xSE + A ]

Considering 12.5% manufacturing tolerance, 7.6 mm.


required thickness, trq =

Rounded off to, 8.0 mm.


Min. Wall thickness as per AWWA-M11, Eqn. 4- (D0+20)/400 8.1 mm
6,for pipe sizes greater than 54 inch
Minimum Wall thickness as per specification 12.0 mm

Increased steel shell thickness, t selected 14.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units
Maxm. Surge pressure to be kept within 1.4* Max Psurge 6.3 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure
### Checking Against Collapsing Pressure for aboveground installation
Not Applicable.

### Pipe Thickness Calculation for Buried Installation:


Description Formula Value Units
Increased thickness of steel pipe to meet the t 14.0 mm
buckling and deflection criteria, t :
0.551 inch
Pipe OD D0 2728 mm
107.40 inch
8.95 ft
Soil coverage on top of pipe as Considered h 1.250 m
4.10 ft
Unit weight. of filled soil as Considered wc 2 ton/m3
124.85 lb/ft3
Modulus of soil E' 1000 psi
Height of water surface above top of pipe (h w) : hw 1.25 m
Soil Load (Dead Load) on the pipe conduit
Soil Load(Wc) : wC x h x D 4582.77 lb/ft
Live Load(WL) : (Ref.Table:6-3 of AWWA M11) psf value 250 psf
hence WL = 2237.53 lb/ft
186.46 lb/inch.
Total load (W) per unit length of pipe : W=WC+WL 6820.30 lb/ft
568.36 lb/inch.

### Checking Against Deflection:


Horizontal deflection of pipe due to soil and truck loading (d x):
(Ref. Eq. 6-5 of AWWA M-11)
KWr 3
d x =D L ( )
EI +0 . 061 -----------------(Eq.
E' r 3 6-5)
Description Formula Value Units
Deflection lag factor, DL : 1.5
Bedding constant, K : 0.1
Load per unit of pipe length, W : 568.36 lb/inch
Outside radius of CW duct, r (=D/2) : 53.70 in
4.48 ft
Modulus of elasticity of pipe, Es = 30000000 psi
Modulus of soil, E' reaction:(assuming 1000 psi
moderate compaction of bedding)
Moment of inertia of cross section of pipewall, Is = 1 3 0.01395 in4/in of pipe
I= bt
12
Description Formula Value Units
Stiffness of steel shell (EsIs) EsIs 418622.88 lb-inch
therefore dx1 = 1.3383 inch
(this must be within 5% of pipe dia if pipe is 1.25 % of OD
flexible lining and coated and calculated value
is=
[ Deflection Criteria: The deflection calculated as per eq.6-5 must be within 2% of pipe
dia if pipe is mortar-lined and coated, 3% of pipe dia if pipe is mortar-lined and
flexible coated, and 5 % of pipe dia if pipe is flexible lining and coated.]

Hence deflection is within allowable limit considering flexible lining and coate
### Checking Against Buckling:
Buckling Pressure Criteria:
(1) Buckling pressure due to live load and soil load must be < the allowable buckling
pressure calculated as per eq.6-7.
(2) Buckling pressure due to soil load and internal vacuum of pipe must be < the
allowable buckling pressure as per eq.6-7
Ref. eq.6-7 of AWWA M11
Allowable buckling pressure (qa) : 1 EI
q a =( )(32R w B'E' 3 )1/2--------Eq. (6-7)
AWWA M11
FS D
Description Formula Value Units
FS=design factor : 2
Water buoyancy factor, Rw= 1-0.33x(hw / h) : 0.67
B'=empirical coefficient of elastic support 0.25
= 1/(1+4 X e^(-0.065h))
D=2r 107.40
Therefore, qa= 21.11 psi
### Condition-1 (considering the external loads as live load, dead load and water
buoyancy )
wC WL
q a1 = y w h w + R w +
D D
Buckling pressure due to live load WL/D 1.74 psi
As calculated below ywhw+RwWc/D 4.16 psi

Hence, buckling pressure, qa1 : 5.90 psi


(this must be less than the calculated allowable buckling pressure, i.e., q a1<qa
Hence, the actual buckling pressure is within the allowable limit.
5.2 Condition-2 (considering dead load, internal vacuum and water buoyancy *):
Ref. Eq. 6-8 of AWWA M11
Buckling pressure due to soil load and internal vacuum condition within pipe (q a2) :

wC
q a2= y w hw + R w + Pv
D ---------(Eq.6-8) AWWA M11

Description Formula Value Units


Specific weight of water, yw 0.0361 lb/cu. inch.
Height of water surface above pipe conduit, hw 49.21 inch.
Density of the pipe material as assumed, 7.85 ton/cu.m.
Soil Load on the pipe conduit, WC 381.90 lb/inch.
Hence ywhw+RwWc/D 4.16 psi
Considering 100% internal vacuum during Pv = 14.69 psi
transient condition
Hence, buckling pressure, qa2 : 18.85 psi
Allowable buckling pressure(psi), q a : 21.11 psi
Since qa >qa2
Hence, the actual buckling pressure is within the
allowable limit considering both type of allowable
buckling pressure
So the required steel pipe thickness to meet the buckling 14 mm
and deflection criteria is
*Since simultaneous application of live load and internal vacuum
transients need not normally be considered, the effect of live load has not
been taken into consideration here.
/in of pipe
CW PIPE THICKNESS CALCULATION
(Ref. AWWA M11 )
A. CONSIDERATION:
### Input Data:
Description Formula Value Units
Assuming CW pump shut off head as internal P 5 kgf/cm2
pressure
Allowable stress, SE : SE 1275 kgf/cm2
(Considering pipes manufactured to CS piping
with IS 2062 GR. B plate material ;SE=0.5Ys,
Where Ys = 250Mpa for thickness <20 mm).
Corrosion allowance A 1.6 mm.

Pipe OD considered Do 4086 mm.


160.87 inch
13.41 ft
Pipe ID calculated Di 4050 mm.
159.45 inch.

### Pipe Thickness Calculation for Internal Pressure:


Description Formula Value Units
Steel Pipe OD, Outer diameter of the pipe is Do 4086 mm.
Minimum wall thickness (tmin) to withstand the tmin 9.61 mm.
internal pressure : [(PxDo)/2xSE + A ]

Considering 5% manufacturing tolerance, 10.1 mm.


required thickness, trq =

Rounded off to, 11.0 mm.


Min. Wall thickness as per AWWA-M11, Eqn. 4- (D0+20)/400 11.5 mm
6,for pipe sizes greater than 54 inch
Increased steel shell thickness, t selected 18.0 mm

### Checking Against Surge Over Pressure Condition


Description Formula Value Units
Maxm. Surge pressure to be kept within 1.5* Max Psurge 7.5 kgf/cm2*
design pressure to maintain the thickness
required for internal pressure

### Checking Against Collapsing Pressure for aboveground installation


Not Applicable.

### Pipe Thickness Calculation for Buried Installation:


Description Formula Value Units
Increased thickness of steel pipe to meet the t 18.0 mm
buckling and deflection criteria, t :
0.709 inch
Pipe OD D0 4086 mm
160.87 inch
13.41 ft
Soil coverage on top of pipe as Considered h 1.000 m
3.28 ft
Unit weight. of filled soil as Considered wc 2 ton/m3
124.85 lb/ft3
Modulus of soil E' 1000 psi
Height of water surface above top of pipe (h w) : hw 1.00 m
Soil Load (Dead Load) on the pipe conduit
Soil Load(Wc) : wC x h x D 5491.26 lb/ft
Live Load(WL) : (Ref.Table:6-3 of AWWA M11) psf value 250 psf
hence WL = 3351.38 lb/ft
279.28 lb/inch.
Total load (W) per unit length of pipe : W=WC+WL 8842.64 lb/ft
736.89 lb/inch.

### Checking Against Deflection:


Horizontal deflection of pipe due to soil and truck loading (d x):
(Ref. Eq. 6-5 of AWWA M-11)
KWr 3
d x =D L
( )
EI +0 . 061 -----------------(Eq.
E' r 3 6-5)
Description Formula Value Units
Deflection lag factor, DL : 1.5
Bedding constant, K : 0.1
Load per unit of pipe length, W : 736.89 lb/inch
Outside radius of CW duct, r (=D/2) : 80.43 in
6.70 ft
Modulus of elasticity of pipe, Es = 30000000 psi
Modulus of soil, E' reaction:(assuming 1000 psi
moderate compaction of bedding)
Moment of inertia of cross section of pipewall, Is = 1 3 0.02966 in4/in of pipe
I= bt
12
Description Formula Value Units
Stiffness of steel shell (EsIs) EsIs 889726.19 lb-inch
therefore dx1 = 1.7626 inch
(this must be within 5% of pipe dia if pipe is 1.10 % of OD
flexible lining and coated and calculated value
is=
[ Deflection Criteria: The deflection calculated as per eq.6-5 must be within 2% of pipe
dia if pipe is mortar-lined and coated, 3% of pipe dia if pipe is mortar-lined and
flexible coated, and 5 % of pipe dia if pipe is flexible lining and coated.]

Hence deflection is within allowable limit considering flexible lining and coate
### Checking Against Buckling:
Buckling Pressure Criteria:
(1) Buckling pressure due to live load and soil load must be < the allowable buckling
pressure calculated as per eq.6-7.
(2) Buckling pressure due to soil load and internal vacuum of pipe must be < the
allowable buckling pressure as per eq.6-7
Ref. eq.6-7 of AWWA M11
Allowable buckling pressure (qa) : 1 EI
q a =( )(32R w B'E' 3 )1/2--------Eq. (6-7)
AWWA M11
FS D
Description Formula Value Units
FS=design factor : 2
Water buoyancy factor, Rw= 1-0.33x(hw / h) : 0.67
B'=empirical coefficient of elastic support 0.24
= 1/(1+4 X e^(-0.065h))
D=2r 160.87
Therefore, qa= 16.45 psi

### Condition-1 (considering the external loads as live load, dead load and water
buoyancy )
wC WL
q a1 = y w h w + R w +
D D
Buckling pressure due to live load WL/D 1.74 psi
As calculated below ywhw+RwWc/D 3.33 psi

Hence, buckling pressure, qa1 : 5.06 psi


(this must be less than the calculated allowable buckling pressure, i.e., q a1<qa
Hence, the actual buckling pressure is within the allowable limit.
5.2*Condition-2 (considering dead load, internal vacuum and water buoyancy *):
Ref. Eq. 6-8 of AWWA M11
Buckling pressure due to soil load and internal vacuum condition within pipe (q a2) :

wC
q a2= y w hw + R w + Pv
D ---------(Eq.6-8) AWWA M11

Description Formula Value Units


Specific weight of water, yw 0.0361 lb/cu. inch.
Height of water surface above pipe conduit, hw 39.37 inch.
Density of the pipe material as assumed, 7.85 ton/cu.m.
Soil Load on the pipe conduit, WC 457.60 lb/inch.
Hence ywhw+RwWc/D 3.33 psi
Considering 80% internal vacuum during Pv = 11.36 psi
transient condition
Hence, buckling pressure, qa2 : 14.69 psi
Allowable buckling pressure(psi), qa : 16.45 psi
Since qa >qa2
Hence, the actual buckling pressure is within the
allowable limit considering both type of allowable
buckling pressure
So the required steel pipe thickness to meet the buckling 18 mm
and deflection criteria is
*Since simultaneous application of live load and internal vacuum
transients need not normally be considered, the effect of live load has not
been taken into consideration here.