Sunteți pe pagina 1din 4

PREVENTIVE MAINTENANCE SCHEDULE: HALF YEARLY

PLASMA SECTION

SL EQUIPMENT INSPECTION ITEMS DATE SIGN


N DON DUE TEC AME
O. E H
UNIT 9MCD A Check for water cooled electric power cables and gun
cooling water connections for their proper fitment and
1. DISTRIBUTIO
serviceability conditions of cables. Check for tightness
N UNIT of insulator guide.
A Clean the nozzle jets with proper size of wire from
back end. Do not use oversize wires. Do not rotate
the wires. Push the wire straight in and out.
B Clean the siphon plug jets with proper size of wire. Do
UNIT 6P-II not use oversize wires. Do not rotate the wires.
GUN C When nozzle is installed on the gun, ensure that
2. siphon plug bore is clean and nozzle nut is firmly
THERMOSPR hand tightened on the siphon plug.
AY GUN D Perform leak checks and checks for any obstructions
in either the oxygen or fuel gas circuits. If any
abnormalities found, fix the problem and do
corrective actions.
E Check for recommended flow rates and pressure.
3. UNIT 4HL A Operate the system and check for any abnormality by
TILTING increasing the speed and decreasing it.
TABLE UNIT B Lubricate if required.
SL EQUIPMENT INSPECTION ITEMS DATE SIGN
N DON DUE TEC AME
O. E H
4. UNIT 6HE A Check for proper operation of the unit.
ELECTRICAL B Ensure that all incating lights are serviceable
CONTROL
UNIT
5. UNIT 4HC A Operate the system and check for any abnormality by
TRAVERSE increasing the speed and decreasing it.
UNIT
6. UNIT 8ME A Operate the system and check for water pressure and
HEAT water temperature. It should be within limits during
operation of system.
EXCHANGER
UNIT
7. UNIT 4MP A Ensure that all incating lights are serviceable during
DUEL operation.
POWDER B Check for gas leaks. Check for positive feeding of
powder after loading.
FEEDER UNIT
SL EQUIPMENT INSPECTION ITEMS DATE SIGN
N DON DUE TEC AME
O. E H
8. SPRAY A Clean ventilation/exhaust system.
BOOTH B Clean water tank. Re-fill with fresh clean water.
C Check for serviceability of fans, power sources, and
filtration equipments. Check for proper operation of
ventilation and exhaust system.
D Check for serviceability of fire protection equipments.
E Check all pipings and their connections for leakage.
F Check for proper earthing and bonding of all
equipments before operation.
G Check water pumps for leakage during operation.
9. GRIT BLAST A Check foot switch for smooth operation
B Check air regulator, pressure gage and exhaust valve
M/C for smooth operation.
C Check air filter for any blockage.
D Check orifice of abrasive mixing tube against wear.
E Check rubber linings of cabin walls.

S-ar putea să vă placă și