Design your application for superior performance


Size heat exchangers for a perfect match
Danfoss XGC gasketed plate heat exchangers

One
global partner
With Danfoss you get one
reliable partner for support,
warranty and service.
Danfoss and our service
partners are nearby present
on all world continents.

districtenergy.danfoss.com
Designed in every scale for superior
energy efficiency and performance

Demands for quality, efficiency These demand conditions require with different characteristics, the
and economy superior performance of all parts of the exchangers can be adapted to a wide
Basically every customer demands system installation and high quality of all variety of applications.
the security of a stable and efficient components. Your supplier must fulfil
operation of the heating and cooling these demands. The XGC heat exchangers can easily
installation. To avoid low comfort be dismantled for inspection, cleaning
periods in the building or downtime Danfoss XGC gasketed plate heat and maintenance. Another benefit of
caused by maintenance and repair, the exchangers the XGC gasketed plate heat exchangers
system installation has to be service Danfoss XGC heat exchangers are is that they can easily be expanded or
friendly. A gasketed plate heat ex- designed for demanding temperature, adapted by adding or replacing plates
changer meets these requirements as pressure and flow conditions. Danfoss when the conditions change.
an efficient and high-quality solution. offers a very comprehensive range of
efficient heat exchangers for applica- The product range is suited for appli-
Since large scale heat exchangers tions in any scale. cations requiring high energy efficiency
are extensive investments, the total like district cooling interchangers,
economy of the system investment is The heat exchangers are built on a district heating substations or cooling/
of significant importance. It is necessary module based concept. Frames, plates heating pressure breakers.
that the operating cost is minimized with and connections can be combined to
high energy efficiency and expectancy form a number of different exchanger
of a long total system lifetime. types. By using different types of plates,
The XGC range offers: Product range specifications:
Tall and narrow types with long
Flow range: 10 - 4000 m3/h
thermal length to achieve close
temperature approach Working pressure: 10 - 25 bar
Compact types for general heating,
HVAC and hot water systems Connections: DN 32 DN 500
Large flow systems
Temperature: -20 to +180C
Double wall types for separation
of drinking water from heating
or cooling water

XGC-013 XGC-042
XGC-008 XGC-009 XGC-016 XGC-026 XGC-044

Connection size, DN 32-50 DN 100

XGC-051
XGC-054 XGC-091 XGC-118 XGC-060 XGC-100 XGC-140

DN 150 DN 200

XGC-085 XGC-145 XGC-205 XGC-265 XGC-325

DN 300

XGC-230 XGC-330 XGC-430

DN 500
In every scale
options from 77 cm to 4,4 meters!

Dimensions
Heat transfer
Type Connections Width B Height H Length D E F
area per
(DN) (mm) (mm) (mm) (mm) (mm)
plate (m2)
XGC 008 0.075 32 180 774 72 640 60

XGC 009 0.088 40 250 725 90 555 100

XGC 013 0.12 50 320 832 140 592 135

XGC 016 0.135 50 320 832 140 592 135

XGC 026 0.27 100 450 1110/1265 164/220 779 226

XGC 042 0.44 100 450 1520/1675 164/220 1189 226

XGC 044 0.44 100 450 1675 220 1189 226

XGC 051 0.55 150 585/630 1730 300 1143 300

XGC 054 0.552 150 630 1730 300 1143 300

XGC 091 0.91 150 626 2390 300 1800 285

XGC 118 1.18 150 626 2870 300 2280 285

XGC 060 0.56 200 825 1700 350 910 420

XGC 100 1.01 200 825 2280 350 1490 420

XGC 140 1.46 200 825 2860 350 2070 420

XGC 085 0.91 300 1060 1985 360 1140 570

XGC 145 1.53 300 1060 2565 360 1720 570

XGC 205 2.14 300 1060 3215 360 2300 570

XGC 265 2.76 300 1060 3795 360 2880 570

XGC 325 3.37 300 1060 4375 360 3460 570

XGC 230 2.37 500 1380/1510/1540 3172 450 2090 700

XGC 330 3.27 500 1380/1510/1540 3782 450 2700 700

XGC 430 4.17 500 1380/1510/1540 4392 450 3310 700


Wide span frame types to fit your needs Plates, gaskets materials,
working conditions

Frame types Plate materials


AISI 304 / EN 1.4301
Frame type NI and PI Frame type N and P
AISI 316 / EN 1.4401
Titanium Grade 1
254 SMO
C-276
Titanium Grade 11
Nickel 200/201

Gaskets
Nitril
EPDM
FKM, Viton

Max. working pressure


T-frame 6 bar
NI/N 10 bar
PI/P 16 bar
SI/S 25 bar

Max. working temp.


Nitril 140C
EPDM 170C
FKM 180C

Approvals
PED 97/23/EC
Special demanding applications
we manage the challenges!

Double wall heat exchangers


No risk of flow media Gasket
contamination with double wall
heat exchangers. Medium 1
The plates are welded together
around the port holes in pairs.
This design requires one additional Gasket
plate per flow channel.
Medium 2
In case a plate or gasket is leaking,
the primary and secondary media will
not be mixed. The leakage will also be
visible from outside. The Heat exchangers
are approved for drinking water. Even if medium 1 should leak, it cannot mix with medium 2.

Gasketed heat exchangers for


district cooling

The district cooling systems with plate Due to the increased heat exchanger sur-
heat exchangers often replace traditional face required for efficient transfer of cold
air-conditioning system in buildings. water into the cooling system, gasketed
As the district cooling plant transfers plate heat exchangers are typically the
cold water through the network to preferred choice.
building and end-users, the district cool-
ing system offers operating flexibility,
lower operation costs and reduced
start-up investment.

Picture: Stockmann Oyj Abp

District Cooling at Stockmann - Outer dimensions of the substation: - The substation includes 7 large
Store-house, Helsinki, Finland: Length 15 m, width 6.5 m and height gasketed plate heat exchangers
Substation with large scale gasketed 3.5 m
heat exchangers from Danfoss. - Pipe sizes on the primary side are
- Capacity of the cooling substation is DN 300, on the secondary side
7.7 MW, divided into 3 circuits DN 150/250/300
Service and maintenance
efficient operation and reduced downtime

Dirt and scale can block your heat carry out performance diagnostics, At partner service centres, Danfoss can
exchanger and cause unplanned high pressure washing of plates while provide you the advanced service that
downtime. Through a partnership hanging in the frame, plate inspection, cannot be performed on site. We offer
agreement with a leading service checking and replacing gaskets as high level competence together
provider, Danfoss offer service at needed and reassemble the unit. with advanced equipment to ensure
customer site or in service centres comprehensive service. We clean the
located strategic places worldwide. A fouled plate pack can be replaced plates and put in new gaskets. Every
If you have no time for servicing, a with a spare plate pack to reduce the plate is thoroughly inspected to locate
service engineer will attend your site service time on the unit. The fouled any pinhole or cracks. After a final
to inspect the plate heat exchanger. plates will be carefully packed and hydrostatic test they are packed and
The engineer will work out an individual shipped to the closest service centre. shipped back to your location.
action plan to fit your requirements,

One global partner


With Danfoss you get one reliable partner for support,
warranty and service. Danfoss and our service partners
are nearby present on all world continents.
Controls for every district heating and cooling application
Danfoss provides a complete range of The product range consists of controllers
automatic controls, heat exchangers for all purposes:
and substations needed throughout Differential pressure and flow
the process of generating and distri- controllers
buting heat or cooling to homes and Self-acting temperature controllers
buildings. Our products contribute Electronic controllers
to individual comfort, reduce energy Motorized control valves
consumption as well as providing reliable Ball valves
and lasting operations and guarantee Heat meters
minimum servicing.
Danfoss offers a wide range of pre-
fabricated substation for heating and
cooling with XGC heat exchangers.

System performance benefits - enabled by Danfoss automatic controls


Differential pressure Ensures adequate heat or cooling supply to all subscribers
control provides: Reduces flow in the network
Hydraulic balancing of the district Reduces energy loss
heating network Increases pump performance
Constant differential pressure (p) Enables accurate temperature control and low return temperature
across the control valve Prolongs the life of the control equipment

Low diffenrential pressure (p) Prevents cavitation


across the control valve Reduces noise emission in the system

Flow control and flow Secures adequate heat or cooling supply to all subscribers
limitation provide: Establishes a reliable basis for settling of fixed subscriber costs
Exact limitation of the flow Ensures optimum hydraulic balance

Temperature controllers provide: Ensures adequate temperatures in your system


Exact temperature control Offers modular design possibilities (e.g. controller + safety thermostat)
Offers safety functions (according to DIN standards)

E-mail: heating@danfoss.com www.districtenergy.danfoss.com