Sunteți pe pagina 1din 13

Equipment List, Electrical

Equipment List, Electrical


Applicable for P910a, P910c, P910i

Contents
1 General ...............................................................................................2
2 Column Definitions ...........................................................................2
2.1 Description Columns .............................................................2
2.2 Process Columns ..................................................................2
3 Repair Equipment, Electrical............................................................3
3.1 Sony Ericsson-Provided Repair Equipment ..........................3
3.2 Equipment Provided by Other Supplier .................................6
4 Revision History ..............................................................................13

131 30-2/FEA 209 544/90 A


Equipment List, Electrical

1 General
This document describes the equipment needed, in addition to the equipment listed in the Mechanical Equipment List, to upgrade the
applicable product(s)s software, test the applicable product(s) and to repair the product(s) at an Electrical Repair Level. The first section is
equipment that can be purchased from a Sony Ericsson Parts and Tools warehouse. The second section is equipment that must be purchased
from other vendors.

2 Column Definitions

2.1 Description Columns


Pos = (Position Number) = The equipment reference numbers used in the Installation Instruction documents.
Description = The name of the equipment.
Part Number = The Sony Ericsson part number to use when ordering from a Sony Ericsson Parts and Tools warehouse.
Comments = Additional information that helps to specify or clarify the equipment.

2.2 Process Columns


These columns show which processes use the equipment. An X in a column indicates that the equipment must be used, and a Z in a
column indicates that the use of that equipment is optional.
Test = A manual and/or automated method of evaluating the functionality of a phone.
Repair = A method of fixing a phone.

131 30-2/FEA 209 544/90 A 2(13)


Equipment List, Electrical

3 Repair Equipment, Electrical

3.1 Sony Ericsson-Provided Repair Equipment

Repair
Test
Pos Description Part Number Comments Picture
51 RF Cable RPM 119 855

X X

62 RF Probe RNT 403 303/001 Using an RF Probe (POS-62) along


with the RF fixture (POS-63) is one
option for making a RF connection
Z X
to the handsets during the GNG
test. Another option is to use the
RF Shield Package (POS 91).
63 RF Fixture NTZ 112 1054 Using an RF Probe (POS-62) along
with the RF fixture is one option for
making a RF connection to the
Z X
handsets during the GNG test.
Another option is to use the RF
Shield Package (POS 91).

131 30-2/FEA 209 544/90 A 3(13)


Equipment List, Electrical

Repair
Test
Pos Description Part Number Comments Picture
52 Battery Eliminator NTZ 112 509 The Battery Eliminator may be used
for the GNG Test and Calibration
Routine only if the Power Supply
Z Z
meets the requirements listed.
See POS-77 for Power Supply
requirements.
9 Sony Ericsson Programming LTN 214 1484 The Sony Ericsson Programming
Interface (SEPI) Interface (SEPI) is used in
conjunction with the SEPI interface
cable (POS 10) and the USB
computer cable (POS 43) to perform
Z X
calibration on this product.

Note: This interface may also be


used in the set up to Flash SW to the
phone.
10 Sony Ericsson Programming KRY 101 1115 This is part of the hardware needed
Interface (SEPI) cable for performing calibration. This
cable connects the phone to the SEPI
(POS 9).
Z X

Note: The SEPI cable may also be


used in the set up used to Flash SW
to the phone.

131 30-2/FEA 209 544/90 A 4(13)


Equipment List, Electrical

Repair
Test
Pos Description Part Number Comments Picture
54 Rework Fixture for PCB LTD 260 273

131 30-2/FEA 209 544/90 A 5(13)


Equipment List, Electrical

3.2 Equipment Provided by Other Supplier

Repair
Test
Pos Description Comments Picture
76 Test and Calibration Instrument options:

Anritsu MT 8801B
Required Components: If it is preferred to use a test instrument that
MT8801B (Radio Com. Analyser) is not specified, the test script must be
MT8801B-02 (SG-local) written according to 2/1524-2/FEA 209 X X
MX880115A (GSM Measurement 544/90 and approval of the test script must
Software) be obtained from Sony Ericsson.
Required Software:
Main 4.02
System 4.05

Anritsu MT 8801C
Required Components:
MT8801C (Radio Com. Analyser)
MX880115A (GSM Measurement
Software)
Required Software:
Main 4.02
System 4.05

131 30-2/FEA 209 544/90 A 6(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
Test and Calibration Instrument options
(Continued):

Anritsu MT 8802A
Required Components:
MT8802A (Radio Com. Analyser)
MX880215A (GSM Measurement
Software)
Required Software:
Main 1.11
System 2.07

Agilent 8960
Required Components:
E5515C (8960 Series 10 Mainframe)
w/ option 2
E1968A GSM Test Application

131 30-2/FEA 209 544/90 A 7(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
Willtek 4403/4405/4407

Required Components:
Firmware 3.21
The 4403 instrument needs to have
option # M897163 installed.

Willtek 4202
Required Components: This instrument is only capable of running a
M101302 - 4202S Mainframe stand alone Go/No Go test.
M 248 418 - GSM 850 option (needed
for the P910a handset only) This instrument does not require SERP.
91 RF Shield Package options: Using an RF shield package is one of the
options for making a RF connection to the
handset during the GNG test. Another
Rohde & Schwarz RF Shield Package option is to use the combination of an RF
CMU-Z10 Shield box fixture (POS 53) and an RF cable (POS 51).
CMU-Z11 Antenna Coupler Z
NOTE: The Rohde & Schwarz package
will require the use of a precision N-type
male to SMA female RF adapter to mate
with the SEMC RF cable (see POS 110 for
ordering information).

131 30-2/FEA 209 544/90 A 8(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
77 Power Supply Device Requirements:
Output Voltage: 0-5 volt minimum.
Output Current: 0-2 amps minimum.
NOTE! Transient response time: < 100 s
If using the Power Supply in conjunction with
a Battery Eliminator (Dummy Battery) to Some examples of Power Supplies that
Z Z
power the phone during test or calibration a meet these requirements are as follows:
high quality DC source that meets the Agilent 66xx series
following requirements must be used. Agilent 663x series
Agilent 663xx series

88 Power cable - Red Cable Requirements:


Minimum cross sectional area of
conductor = 1.2mm2
Maximum length = 1.5 m
One end of cable must have a male
banana-type connector to be able to Z Z
interface with the Battery Eliminator.
The other end of the cable needs
whatever connection is necessary to
connect to the power supply that you
have.

131 30-2/FEA 209 544/90 A 9(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
89 Power cable - Black Cable Requirements:
Minimum cross sectional area of
conductor = 1.2mm2
Maximum length = 1.5 m
One end of cable must have a male
banana-type connector to be able to Z Z
interface with the Battery Eliminator.
The other end of the cable needs
whatever connection is necessary to
connect to the power supply that you
have.
79 Large Convection (Hot Air) Device Certain components on the parts list can
only be replaced using this device. It is
specified in the parts list, which parts
require the use of this device to be
replaced.

X
Device Requirements:
The device should allow variable
adjustment over a temperature range.
The range of airflow the device is
capable of generating should fall above
20 litre/minute.

131 30-2/FEA 209 544/90 A 10(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
80 Nozzles for Large Convection (Hot Air) NOTE: Only necessary if you have a large
X
Device convection device.
82 Microscope Minimum magnification required is 10x X
90 Component baking oven Temperature requirements: 125C +5C/-
0C
X
Required for drying moisture sensitive
components.
83 GPIB Card National Instruments or Keithley

NOTES:
A GPIB card is required for SERP. Z X
Drivers are required and will be
supplied with the card.

84 GPIB Cable Z X
43 USB Computer Cable Type A to Type B USB cable.

This is part of the hardware needed for


performing calibration. This cable connects
Z X
the computer (POS 96) to the SEPI (POS
9).
Note: This cable may also be used in the set
up used to Flash SW to the phone.

131 30-2/FEA 209 544/90 A 11(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
96 Computer One of the following operating systems
must be used:
Windows 2000 with service pack 2 or
higher.
Windows XP.

Minimum Requirements: Z X
One unused PCI slot for GPIB card.
Two (2) USB Ports.
The processor and RAM of the
computer should at least meet the the
minimum requirements specified by the
operating system's manufacturer.
99 Test SIM According to your Instrument supplier. X Z
109 Printer Optional, but recommended. Z Z

131 30-2/FEA 209 544/90 A 12(13)


Equipment List, Electrical

Repair
Test
Pos Description Comments Picture
110 RF adapter (Precision) for RF shield box This adapter is used to connect the RF
shield box (POS-91) to the RF cable (POS
51) and is only required if a shield package
The adapter for the Rohde & Schwarz is going to be used for the GNG test.
Shield box must be a precision N-type
Z
male to SMA female adapter. Possible source:
Pasternack Enterprises - (949) 261-
1920 or www.pasternack.com
Part number: PE9430

4 Revision History
Rev. Date Changes / Comments
A 2004-08-16 Initial Release

131 30-2/FEA 209 544/90 A 13(13)