Documente Academic
Documente Profesional
Documente Cultură
IEC 61850
Moxa Systems
August, 2009
Theme
Confidential
Future of Power: Smart Grid
Confidential
Smart Grid Infrastructure
Substation Automation
Advanced Metering Infrastructure
Power
Generation Customers
DNP 3.0
IEC 60870-5
DNP 3.0
ModBus
ModBus
Confidential
Protocol Trend for Power Automation
Newton Evans: 2005-2007
Migrating to
Ethernet-based
Confidential
Future Power Automation Protocols
DNP 3.0
LAN
IEC
IEC60870-5
61850
DNP 3.0
ModBus
ModBus/TCP LAN
ModBus
ModBus/TCP
Confidential
Substation Automation Empowered
By IEC 61850
Confidential
Benefits of IEC 61850 Power
Substation
Protocol Integration
Easy
Time to Market
Maintenance IEC 61850
Confidential
Moxa Offering
Confidential
Moxa Embedded Solution
Confidential
Lead with IEC61850-3 Certified
Embedded Computer DA-681
PASS!
DA-681-I-DPP-T
IEC 61850-3 Test
Confidential
Using DA-681 in IEC61850-3 Substation
Requirements
IEC61850-3 certified hardware
Multiple LANs to connect IED device and communicate
dispatch control center
Requires 100-240 AC/DC power input
19-inch rackmount, fanless design
Benefits
The DA-681 has 6 LANs for network redundancy and
centralized communication
Excellent patented heat dissipation design for use in
-40 ~ 75C environments
Serial port with isolation protection for integrating legacy RTU
into IEC 61850 substation
Dual power design to connect simultaneously to 100 VDC and
240 VAC power sources
Confidential
Features Briefing
Intel x86 1GHz CPU with 910GMLE chipset
Built-in DDR2 SDRAM and industrial-grade
DOM
19-inch rackmount installation, 1U high
6 Ethernet ports for network redundancy
2 USB 2.0 Host, supporting system boot up
4 Serial 232 & 8 RS-485 ports (wide baud rate)
CF/SATA interfaces for storage expansion
100 to 240V AC/DC power input
Dual power for redundant application (DP/DPP
model only)
Fanless and low power consumption design
Confidential
Challenges to Certify IEC 61850-3
Function Test
EMC Test
Anti-Vibration Test
Confidential
Unique Design to Conquer EMC Test
Confidential
Wide Temperature Know-How
Thermal Placement
Optimization of
Components Natural-Convection
Chamber to Test
Wide Temperature
Components Database
Optimal Heat Transfer
Methods
Confidential
Special Heat Dissipation Design
Confidential
System Throttling Design
time
Confidential
120 hours Uninterrupted Testing
Confidential
Production Quality Management
(Dynamic Burn-in)
High temp. (55~75dc) Room temp. (30~40dc) Wide temp. (-40~85 dc)
Pilot Run 24~48hrs Mass Production 4~24hrs W/T Product screen 24 hrs
Over 80% function test items are covered during burn-in test program.
Monitoring programs control the entire burn-in status,
and show the data for analysis.
Confidential
Anti-Vibration Tolerance Test
50 G Anti-Shock
5-500 MHz Anti-Vibration
Confidential
Summary
Confidential
Thanks!
Confidential