Sunteți pe pagina 1din 5

The voltage masured in mv, produced by a type-k thermocouple

for varius junction temprature is shown in the next sheet.


1 - Type in your name in the boxes bellow to generate your unique data set.
2 - Plot the date using excel scatter plot.
3 - Calculate the coefficient of the linear regression and R 2 value as explained in class.
4 - Fit a line to data using excel trendline and compare the equation and R 2 value with your calculation

First Name Last Name Your Unique Code


Tanyia Bynum 150
ned in class.
R 2 value with your calculations.
Temprature, T(oC) Voltage, V(mV) t1-tbar v1-vbar (t1-tbar)^2
50 1.9815 -356.25 -14.81625 126914.0625
100 4.3515 -306.25 -12.44625 93789.0625
200 7.7615 -206.25 -9.03625 42539.0625
300 12.5115 -106.25 -4.28625 11289.0625
400 16.7015 -6.25 -0.09625 39.0625
500 19.6215 93.75 2.82375 8789.0625
700 29.4315 293.75 12.63375 86289.0625
1000 42.0215 593.75 25.22375 352539.0625

Sum of T Sum of V Sum(t1-tbar)^2


3250 134.382 722187.5

N of T N of V N of T-1
8 8 7

Tbar Vbar Sum of T^2


406.25 16.79775 103169.64286

Sqaure of ST
321.20031578
(v1-vbar)^2 (t1-bar)/st (v1-vbar)/vt Product(G*h)
219.521264063 -1.109121 -1.0964099 1.2160511395
154.909139063 -0.9534549 -0.9210287 0.8781592618
81.6538140625 -0.6421227 -0.668687 0.4293790626
18.3719390625 -0.3307905 -0.3171846 0.1049216485
0.0092640625 -0.0194583 -0.0071225 0.0001385924
7.9735640625 0.29187393 0.2089589 0.0609896567 Temprature & Vo
159.611639063 0.91453833 0.93490377 0.855005331 45
636.237564063 1.84853492 1.86657002 3.4504198576 40 f(x) = 0.0420419732x - 0.2
35 R = 0.9985903686
Sum(v1-vbar)^2 Sum of Product 30
1278.2881875 6.9950645501 25
Voltage(V) 20
15
N of V r=SP/N-1
10
7 0.9992949357
5
0
Sum of V^2 R^2 0 200 400 60
182.612598214 0.9985903686 Tempra

Square of SV M=R*SV/ST
13.5134228904 0.0420419732

B=vbar-m*tbar
-0.281801601
Temprature & Voltage

= 0.0420419732x - 0.281801601
= 0.9985903686

200 400 600 800 1000 1200

Temprature(C)

S-ar putea să vă placă și