Experiment 1:Counter-Current
Calculations
Hot Water
Density: 988.18 kg/m3
Heat Capacity: 4175.00 J/kg.K
Thermal cond: 0.6436 W/m.K
Viscosity: 0.0005494 Pa.s
Cold Water
Density: 995.67 kg/m3
Heat Capacity: 4183.00 J/kg.K
Thermal cond: 0.6155 W/m.K
Viscosity: 0.0008007 Pa.s
Shell & Tube Heat Exchanger
Shell:
Internal diameter 82 mm
Length 500 mm
Material Borosilicate glass
Tube:
External diameter 9.53 mm
Internal diameter 7.75 mm
Length 500 mm
Tube count 10 (single pass)
Tube pitch 18 mm (triangle)
Baffle 8
Baffle cut 20%
Material Stainless steel 316L
2
Exchange area: 1.15 m (approx.)
1 m L 1 m3 1 min
60 s 2.0
min 1000 L 60 s
L 1 m3
10.0
min 1000 L kg J
995.67 4183
m 3
kg
kg J
988.18 4175
m
3
kg ( 45.430.3 )
( 49.347.1 )
2096.33W
1512.74 W
8.83
= 1142.12 W/m.K
Result for heat transfer hot, heat transfer cold, heat loss, efficiency and LMTD for different flow