Documente Academic
Documente Profesional
Documente Cultură
705010E, Ed.1
December 2004
www.saabrosemount.com
Technical Description
705010E, Ed.1
December 2004 Saab TankMaster HTG
Contents
Available technical documentation for Saab TankMaster HTG: ___________________________ 2
Abbreviations used in this document: ___________________________________________________ 3
1
Technical Description
705010E, Ed.1
Saab TankMaster HTG December 2004
2
Technical Description
705010E, Ed.1
December 2004 Saab TankMaster HTG
Abbreviations used in this document:
3
Technical Description
705010E, Ed.1
Saab TankMaster HTG December 2004
4
Technical Description
705010E, Ed.1
December 2004 Saab TankMaster HTG
Summary of functions & system overview TankMaster HTG system for display of measured
and calculated values. Protocols for communication
The TankMaster HTG system measures and with major suppliers of plant host computers have
calculates tank data for: been developed and certified.
Inventory calculations
Mass Custody transfer TankMaster HTG system overview.
Product movement
TankMaster PC for
data communication,
The HTG system is primarily calculating the mass calculations, displaying LAN
and reporting
of the product. These parameters are shown in the Host
5
Technical Description
705010E, Ed.1
Saab TankMaster HTG December 2004
Vapor pressure
All data is calculated according to updated API and
ISO standards. The temperature calculations include
API algorithms to handle elements close to the
bottom.
Liquid pressure
Temperature
Both metric and USA/UK units are supported.
Liquid pressure
TankMaster performs net volume calculations with
very high accuracy using up to 2000 strapping
points. TankMaster is using quadratic interpolation
for spheres and horizontal cylinders, which
Comparison of the pressure readouts from the increases volume accuracy and reduces number of
two submerged transmitters P1 and P2 are used strapping points. The TankMaster HTG system is
to calculate the specific gravity of the liquid, NMi certified for mass custody transfer. A hardware
thus generating mass and density. The pressure key is required for HTG calculations to be available.
transmitter P2 is optional, and if P2 is not used, the
density can be entered manually into TankMaster.
The liquid level can be determined by comparing
readouts from P3 (which measures the vapor
pressure in the tank) and P1.
6
Technical Description
705010E, Ed.1
December 2004 Saab TankMaster HTG
Base board
The base board is connecting everything together
inside the DS4. The base board also includes the
power supply.
7
Technical Description
705010E, Ed.1
Saab TankMaster HTG December 2004
Modbus
Modbus
TankMaster TankMaster
OPC Server OPC Server DCS
Modbus
DS4
PLC
HART FCU
TRL2 Field Bus Tank data, Level, Temperature, Pressure, Volume, etc.
8
Technical Description
705010E, Ed.1
December 2004 Saab TankMaster HTG
Reports and data sampling
Batch report for internal and external transfers.
Customized Reports to Microsoft Office
programs.
Automatic reports.
Reports via e-mail.
Audit log for events.
Historical data sampling.
Alarms
Reliable alarm handling of measured values with
high, high-high, low and low-low level alarms.
Alarms to mobile phones.
Alarms via e-mail.
TankMaster gives the most important inventory data for a specific tank in Leakage alarms based on net volume.
one easy-to-read window.
9
Technical Description
705010E, Ed.1
Saab TankMaster HTG December 2004
Others
User manager with different access levels for
personnel.
Customized views with graphic plant layouts.
Easy translation to other languages than English.
Advanced group configuration in geographical or
product groups etc.
Compatibility with Saabs earlier platform OPI
which can easily be replaced by TankMaster.
PC Requirement
10
Technical Description
705010E, Ed.1
Saab TankMaster HTG December 2004
www.saabrosemount.com