SCHEDULE OF FINISHES

Walls
Footings 230x600mm in medium strength concrete to NBR standard and SANS 10400.
Walls are built with 90mm bricks - heights as per plan. External walls to plastered and
painted with 50mm cavity between internal and external skins with 2.5 butterfly wire
26.5 ties per square meter. All internal walls plastered with lime cement.
ROOF PITCH Brickforce in 4 layers over all openings, with precast concrete lintels to openings

1,744
greater than one metre.
300 300
Window-sills
External & Internal, smooth finished cement plaster.

4,294
DPC Roof Construction
Cement roof tiles @ 26.5 pitch on 38x38 SAP battens at maximum 320 centres on
prefabricated gangnail trusses at maximum 760 c/c, fixed to 114x38 wallplates and
2,550 anchored to brickwork with 30x2mmx1m hoop iron ties, built into walls for minimum of
PLASTER & PAINT 600mm. SABS approved underlay to tiled roof. All roof timber to be minimum Grade 5
NGL SA Pine TAN treated. All gable ends to be tied with hoop iron built into wall for
FRONT ELEVATION 1 minimum 600mm and up to two trusses away from gable to SANS 10400-L where
applicable. Bracing as per A19 Engineer.
SCALE 1:100
BEDRM LOUNGE
DPC DPC Eaves
400x200 250mic DPM
375mic DPM UNDER ALL WALLS 300mm Open eaves overhang with 225mmx10mm painted fibre cement fascias.
THICKENED
MINIMUM 150mm ABOVE FGL FOUNDATION
600x230 600x230 Rainwater Disposal
SECTION A-A Alu. gutters with 75mm PVC downpipes as per plan.
SCALE 1:100
Ceilings
3 25mm Isoboard EPS ceiling on 38 x 38 SA Pine battens at 300mm spacing and 76mm
Rhino cornice with 155mm thick flexible polyester blanket(Isotherm).

Floors
6,300 Finished as per plan and/or client choice/building tender, on 25mm screed, on 80mm
230 90 230 concrete for ground storey, (as above) on 250 micron waterproof sheeting, on
2,400 3,350 compacted filling and sand blinding. All floor levels to be a minimum of 150mm above
230 90 90 230 FGL.
2,400 900 2,360
Doors & Windows
3,945 900 1,455 Windows top-hung aluminium, as per plan codes & elevations.
W6 Note : Safety glass to window panes larger than 1sq.m or closer than 500mm from
(900x1100) FFL to SANS 10137 and to comply to SANS 10400-N.
DP ELEVATION 2
230

230

230
SCALE 1:100 Drainage
BEDRM 1 110mm Smooth uPVC Sewer pipe with minimum 1:60 fall with IL at minimum
1,575

BEDRM 2 (Carpet) 450mm. 50mm 2way vent valve on start of one pipe sewer system. All sewer lines
B.I.C

(Carpet) passing under structure to comply to SANS 10400-PP24 (encase in sand or concrete).
2,600

2,600
All drainage to comply to SANS 10400-P.
(900x1100)

3,520
3,590

Electricals - as per building tender.


W6
900

Position of Oostersee Electrical connection box on exterior wall to be determined on


site.
90

90

NOTES:
Figured dimensions takes preference to scaled dimensions.
2,335

All relevant levels and dimensions to be verified on site prior to construction.


(900x900)

B.I.C BATH RM
1,900

All work to comply to NBR, Local Bylaws and Municipal Regulations.


(Tiles)
90

900
W5

B.I.C All levels to be determined on site and can/may be to adjusted to the descrepancy
HWC IN

4
ROOF

of the developer and his appointed builder. Developer to approve plan prior to
9,510

9,510

2
(900x1100)

PLASTER & PAINT submission to council.


90

All glazing to SANS 10137 & SANS 10400-N. Printed dimensions take prference over
2,700

TV
900

1,885
W6

scaled dimensions. All work to be carried out in strict accordence to NBR and local
ELEVATION 3 bylaws.
5,760

A A SCALE 1:100
BEDRM 3 Finishes in builders contract takes preference over finishes specified on plan.
LOUNGE In case of discrepances the author of the plan should be contacted before proceeding
(Carpet)
1,840

(1500x1500)

(Tiles) with any construction.


90

1,500

4,370
W1

KITCHEN
(Tiles)
2,580

900

1,705

PD26
230

1,060

WM
600
230

230

W5 W6
(900x900) (900x1100)
980 900 980 900 820 900 820 PLASTER & PAINT 37 VAN DER STEL STREET P.O. BOX 1399 TEL: 021 906 6770
KUILSRIVER KUILSRIVER FAX: 021 906 6775
230 90 230
2,400 3,350 ELEVATION 4 7579 7580 EMAIL : nationhousing@mweb.co.za
230 230 230 230 SCALE 1:100
2,400 900 2,080 ELECTRICAL HOUSE PLAN- Type 5-60 sq.m DATE : AUG 2016
6,300 TELEPHONE POINT
PROPOSED NEW DWELLING DRAWING : Type 5-60 sq.m
CEILING LIGHT POINT MONTCLAIR
FOR .......... ON ERF ...... , PROJECT :NATION HOUSING
1 SANS 10400-XA WATERPROOF LIGHT POINT
MONTCLAIR SCALE : 1:100
15 AMP PLUG POINT
HWC DETAILS:
FLOOR PLAN
SCALE 1:100
PIPING 15mm AND 22mm CLASS 1
COPPER TUBE
15 AMP UNDERCOUNTER
MOUNT PLUG POINT
AREA HOUSE : 60 sq.m HWC KWIKOT ECONO STD GALV. 150L
15 AMP PLUG POINT 2000mm HIGH
WALLS EXT. 230 CAVITY GEYSER.
1200mm HIGH PC WALL LAGGING (R=1) ON ALL EXPOSED PIPES DISTRIBUTION BOARD
INT. 90 x 190 mm
BUILDING LINES W1= 1.5x1.5 = 2.25 sq.m TV TV POINT
RAINWATER CHANNEL NOTE: W5 = (0.9 x 0.9)x2 = 1.62 sq.m
DP FFL ABOVE NGL TO BE W6= (0.9x1.1) x 4 = 3.96 sq.m
RAINWATER D.P. STOVE CONNECTION
TOTAL =7.83 sq.m
110mm PVC SEWER DETERMINED ON SITE. FLOOR AREA : 60 sq.m
AT 1:40 GRADIENT MINIMUM 150mm. FENESTRATION PERCENTAGE : 13.05 % BALL FITTINGS TO ALL LIGHT POINTS