SVM204-A
Return to Master TOC
October, 2010
View Safety Info
OUTBACK 185
For use with machine code number: 11516
SERVICE MANUAL
Return to Master TOC
View Safety Info
WARNING
Return to Master TOC
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of Safety in Welding & Cutting - ANSI Standard Z49.1 from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of Arc Welding Safety booklet E205 is available from the
Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
Return to Master TOC
ELECTRIC AND
MAGNETIC FIELDS
____________________________________________________
1.c. Do not add the fuel near an open flame weld- may be dangerous
ing arc or when the engine is running. Stop
the engine and allow it to cool before refuel- 2.a. Electric current flowing through any conductor causes
ing to prevent spilled fuel from vaporizing on localized Electric and Magnetic Fields (EMF). Welding
contact with hot engine parts and igniting. Do current creates EMF fields around welding cables and
Return to Master TOC
not spill fuel when filling tank. If fuel is spilled, welding machines
wipe it up and do not start engine until fumes
have been eliminated. 2.b. EMF fields may interfere with some pacemakers, and
____________________________________________________ welders having a pacemaker should consult their physician
1.d. Keep all equipment safety guards, covers and devices in posi- before welding.
tion and in good repair.Keep hands, hair, clothing and tools
away from V-belts, gears, fans and all other moving parts 2.c. Exposure to EMF fields in welding may have other health
when starting, operating or repairing equipment. effects which are now not known.
____________________________________________________
2.d. All welders should use the following procedures in order to
1.e. In some cases it may be necessary to remove safety
minimize exposure to EMF fields from the welding circuit:
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete. 2.d.1. Route the electrode and work cables together - Secure
Always use the greatest care when working near moving them with tape when possible.
parts.
___________________________________________________ 2.d.2. Never coil the electrode lead around your body.
1.f. Do not put your hands near the engine fan. 2.d.3. Do not place your body between the electrode and
Do not attempt to override the governor or work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
Return to Master TOC
OUTBACK 185
ii SAFETY ii
3.a. The electrode and work (or ground) circuits 4.a. Use a shield with the proper filter and cover
are electrically hot when the welder is on. plates to protect your eyes from sparks and
Do not touch these hot parts with your bare the rays of the arc when welding or observing
skin or wet clothing. Wear dry, hole-free open arc welding. Headshield and filter lens
gloves to insulate hands. should conform to ANSI Z87. I standards.
3.b. Insulate yourself from work and ground using dry insulation. 4.b. Use suitable clothing made from durable flame-resistant
Make certain the insulation is large enough to cover your full material to protect your skin and that of your helpers from
area of physical contact with work and ground. the arc rays.
In addition to the normal safety precautions, if welding 4.c. Protect other nearby personnel with suitable, non-flammable
must be performed under electrically hazardous screening and/or warn them not to watch the arc nor expose
conditions (in damp locations or while wearing wet themselves to the arc rays or to hot spatter or metal.
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or FUMES AND GASES
accidental contact with the workpiece or ground) use
the following equipment: can be dangerous.
Semiautomatic DC Constant Voltage (Wire) Welder. 5.a. Welding may produce fumes and gases
Return to Master TOC
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
OUTBACK 185
iii SAFETY iii
6.g. Connect the work cable to the work as close to the welding switch at the fuse box before working on
area as practical. Work cables connected to the building the equipment.
framework or other locations away from the welding area
increase the possibility of the welding current passing through 8.b. Install equipment in accordance with the U.S. National
lifting chains, crane cables or other alternate circuits. This can Electrical Code, all local codes and the manufacturers
create fire hazards or overheat lifting chains or cables until recommendations.
they fail.
8.c. Ground the equipment in accordance with the U.S. National
6.h. Also see item 1.c. Electrical Code and the manufacturers recommendations.
6.I. Read and follow NFPA 51B Standard for Fire Prevention
During Welding, Cutting and Other Hot Work, available from
NFPA, 1 Batterymarch Park,PO box 9101, Quincy, Ma
022690-9101.
OUTBACK 185
iv SAFETY iv
Sret Pour Soudage A LArc 8. Sassurer que la masse est connecte le plus prs possible de
1. Protegez-vous contre la secousse lectrique: la zone de travail quil est pratique de le faire. Si on place la
masse sur la charpente de la construction ou dautres endroits
a. Les circuits llectrode et la pice sont sous tension loigns de la zone de travail, on augmente le risque de voir
quand la machine souder est en marche. Eviter toujours passer le courant de soudage par les chaines de levage,
tout contact entre les parties sous tension et la peau nue cbles de grue, ou autres circuits. Cela peut provoquer des
ou les vtements mouills. Porter des gants secs et sans risques dincendie ou dechauffement des chaines et des
trous pour isoler les mains. cbles jusqu ce quils se rompent.
b. Faire trs attention de bien sisoler de la masse quand on
soude dans des endroits humides, ou sur un plancher met- 9. Assurer une ventilation suffisante dans la zone de soudage.
allique ou des grilles metalliques, principalement dans Ceci est particulirement important pour le soudage de tles
Return to Master TOC
les positions assis ou couch pour lesquelles une grande galvanises plombes, ou cadmies ou tout autre mtal qui
partie du corps peut tre en contact avec la masse. produit des fumes toxiques.
c. Maintenir le porte-lectrode, la pince de masse, le cble de
soudage et la machine souder en bon et sr tat defonc- 10. Ne pas souder en prsence de vapeurs de chlore provenant
tionnement. doprations de dgraissage, nettoyage ou pistolage. La
d.Ne jamais plonger le porte-lectrode dans leau pour le chaleur ou les rayons de larc peuvent ragir avec les vapeurs
refroidir. du solvant pour produire du phosgne (gas fortement toxique)
e. Ne jamais toucher simultanment les parties sous tension ou autres produits irritants.
des porte-lectrodes connects deux machines souder
parce que la tension entre les deux pinces peut tre le total 11. Pour obtenir de plus amples renseignements sur la sret, voir
de la tension vide des deux machines. le code Code for safety in welding and cutting CSA Standard
f. Si on utilise la machine souder comme une source de W 117.2-1974.
courant pour soudage semi-automatique, ces precautions
pour le porte-lectrode sapplicuent aussi au pistolet de
soudage.
contre les chutes dans le cas ou on recoit un choc. Ne jamais LES MACHINES SOUDER
enrouler le cble-lectrode autour de nimporte quelle partie du
corps.
TRANSFORMATEUR ET
REDRESSEUR
3. Un coup darc peut tre plus svre quun coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant appropri ainsi 1. Relier la terre le chassis du poste conformement au code de
quun verre blanc afin de se protger les yeux du rayon- llectricit et aux recommendations du fabricant. Le dispositif
nement de larc et des projections quand on soude ou de montage ou la piece souder doit tre branch une
quand on regarde larc. bonne mise la terre.
b. Porter des vtements convenables afin de protger la peau
de soudeur et des aides contre le rayonnement de larc. 2. Autant que possible, Iinstallation et lentretien du poste seront
c. Protger lautre personnel travaillant proximit au effectus par un lectricien qualifi.
soudage laide dcrans appropris et non-inflammables.
3. Avant de faires des travaux linterieur de poste, la debranch-
4. Des gouttes de laitier en fusion sont mises de larc de er linterrupteur la boite de fusibles.
soudage. Se protger avec des vtements de protection libres
Return to Master TOC
de lhuile, tels que les gants en cuir, chemise paisse, pan- 4. Garder tous les couvercles et dispositifs de sret leur place.
talons sans revers, et chaussures montantes.
OUTBACK 185
Return to Master TOC v SAFETY v
Conformance
Products displaying the CE mark are in conformity with European Community Council Directive of 15 Dec
2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility,
2004/108/EC. It was manufactured in conformity with a national standard that implements a harmonized
standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment.
It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction
All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be
transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions
are received by other equipment, electrical interference may result. Electrical emissions may affect many
kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled
Return to Master TOC
machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions
may be required when a welding power source is used in a domestic establishment.
Note: The welding circuit may or may not be earthed for safety reasons according to national
codes. Changing the earthing arrangements should only be authorized by a person who is
competent to access whether the changes will increase the risk of injury, e.g., by allowing
parallel welding current return paths which may damage the earth circuits of other equip-
ment.
Return to Master TOC
Assessment of Area
Before installing welding equipment the user shall make an assessment of potential electromagnetic prob-
lems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment;
e) the health of the people around, e.g., the use of pacemakers and hearing aids;
Return to Master TOC
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
OUTBACK 185
Return to Master TOC vi SAFETY vi
The size of the surrounding area to be considered will depend on the structure of the building and other
activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.
Mains Supply
Welding equipment should be connected to the mains supply according to the manufacturers recommenda-
tions. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains
supply. Consideration should be given to shielding the supply cable of permanently installed welding equip-
ment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The
shielding should be connected to the welding power source so that good electrical contact is maintained
between the conduit and the welding power source enclosure.
Return to Master TOC
Welding Cables
The welding cables should be kept as short as possible and should be positioned close together, running at
or close to floor level.
Equipotential Bonding
Bonding of all metallic components in the welding installation and adjacent to it should be considered.
However, metallic components bonded to the work piece will increase the risk that the operator could
receive a shock by touching these metallic components and the electrode at the same time. The operator
should be insulated from all such bonded metallic components.
Return to Master TOC
_________________________
Return to Master TOC
1 Portions of the preceding text are contained in EN 60974-10: Electromagnetic Compatibility (EMC) prod-
uct standard for arc welding equipment.
OUTBACK 185
I - MASTER TABLE OF CONTENTS FOR ALL SECTIONS - I
Page
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i-vi
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section A
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section B
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section C
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section D
OUTBACK 185
Return to Master TOC A-1 TABLE OF CONTENTS - INSTALLATION SECTION A-1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Storing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-3
Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4
Tilting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4
Return to Master TOC
Lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4
Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4
Fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-4
OUTBACK 185
A-2 INSTALLATION A-2
Return to Section TOC
Return to Master TOC
KOHLER 1 cylinder 3750RPM High Idle 21.96 cu. in Electric & Recoil Fuel: 6.86 gal.
CS 12.75 4 cycle 1825RPM Low Idle (360 cc) Start; (24.9L)
air-cooled 3400RPM Full Load
OHV gasoline Bore x Stroke Manual Oil: 1.2 Qts.
12.75 HP @ Choke (1.1L)
3600 RPM 3.35 x 2.48
Aluminum Block (85 mm x 63mm)
w/ Cast Iron Sleeve
Return to Section TOC
Return to Master TOC
100 100% 25
130 60% 25
150 20% 25
185 MAX OUTPUT ---
PHYSICAL DIMENSIONS
Return to Master TOC
OUTBACK 185
A-3 INSTALLATION A-3
OUTBACK 185
A-4 INSTALLATION A-4
STACKING OIL
Return to Section TOC
Return to Master TOC
OUTBACK 185 machines CANNOT be stacked. The OUTBACK 185 is shipped with the engine filled
with SAE 10W30 oil. CHECK THE OIL LEVEL
TILTING BEFORE YOU START THE ENGINE. This is an added
precaution. Do not screw in dipstick when checking oil
level. DO NOT OVERFILL. Be sure the fill plug is tight
Place the machine on a secure, level surface whenev-
after servicing.
er you use it or store it. Any surfaces you place it on
other than the ground must be firm, non-skid, and
structurally sound. FUEL
The gasoline engine is designed to run in a level posi- Fill the fuel tank with clean, fresh, regular grade (mini-
tion for best performance. It can operate at an angle, mum 87 octane lead free gasoline. DONOTMIX OIL
but this should never be more than 15 degrees in any WITHGAS. The OUTBACK 185 capacity is approxi-
direction. If you do operate it at a slight angle, be sure mately 6.8 gallons (25.74 Liter). DO NOT OVERFILL,
to check the oil regularly and keep the oil level full. allow room in the fuel tank for fuel expansion.
Also, fuel capacity will be a little less at an angle.
Return to Section TOC
Return to Master TOC
------------------------------------------------------------------------
Keep hands away from muffler or HOT engine
parts.
Stop the engine when fueling.
Do not smoke when fueling.
Remove fuel cap slowly to release pressure.
Do not overfill tank.
Wipe up spilled fuel and allow fumes to clear
before starting engine.
Keep sparks and flame away from tank.
------------------------------------------------------------------------
Return to Section TOC
Return to Master TOC
OUTBACK 185
A-5 INSTALLATION A-5
1 4
8 7 5
9
6
10
Return to Section TOC
Return to Master TOC
2
FIGURE A.1
1. CURRENT CONTROL DIAL 7. DUPLEX RECEPTACLE (2)- 120 VOLT, 20 AMP
2. WELD OUTPUT TERMINALS (2) 8. HOURMETER
3. GROUND STUD 9. ENGINE SWITCH
4. CIRCUIT BREAKERS (2) - 20 AMP 10. CHOKE
5. CIRCUIT BREAKER 30 Amp
6. RECEPTACLE - 240 VOLT, 50 AMP
Return to Section TOC
Return to Master TOC
OUTBACK 185
A-6 INSTALLATION A-6
OUTBACK 185
A-7 INSTALLATION A-7
For further protection against electric shock, any elec- The OUTBACK 185 is not recommended for premis-
trical equipment connected to the generator recepta- es wiring. The OUTBACK 185 does not have a com-
cles must use a three-blade, grounded type plug or an bined 120/240 volt receptacle and cannot be connect-
Underwriters Laboratories (UL) approved double insu- ed to a premises as described in other Lincoln litera-
lated tool with a two blade plug. ture.
OUTBACK 185
A-8 INSTALLATION A-8
Return to Section TOC
Return to Master TOC
CAUTION
Certain Electrical devices cannot be powered by the OUTBACK 185. See Table A.2
TABLE A.2
ELECTRICAL DEVICE USE WITH THE OUTBACK 185
Capacitive / Inductive Computers, high resolution TV sets, An inductive type line condition-
complicated electrical equipment. er along with transient and
surge protection is required,
and liabilities still exist.
DO NOT USE THESE DEVICES
WITH A OUTBACK 185.
Return to Section TOC
Return to Master TOC
The Lincoln Electric Company is not responsible for any damage to electrical components
improperly connected to a OUTBACK 185.
OUTBACK 185
Return to Master TOC B-1 TABLE OF CONTENTS - OPERATION SECTION B-1
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-4
OUTBACK 185
B-2 OPERATION B-2
SAFETY INSTRUCTIONS
Return to Section TOC
Return to Master TOC
WARNING WARNING
ELECTRIC SHOCK
ENGINE EXHAUST can kill.
can kill.
Use in open, well ventilated areas
Do not touch electrically live parts or vent exhaust outside.
or electrode with skin or wet Do not stack anything on or near
clothing. the engine.
WELDING SPARKS
can cause fire or
explosion
ARC RAYS
can burn.
OUTBACK 185
B-3 OPERATION B-3
Return to Section TOC
Return to Master TOC
WARNING / CHOKE
CAUTION
CIRCUIT
Return to Section TOC
FUEL
Return to Master TOC
BREAKER
FAST ELECTRODE
WELDING ARC
Return to Section TOC
Return to Master TOC
OUTBACK 185
B-4 OPERATION B-4
ADVANTAGES
The OUTBACK 185 is designed for commercial use
welder/generator applications. As a welder it provides
185 amp DC constant current welding for stick
185 amps of DC constant current for welding with DC
electrodes.
stick electrodes. A single dial lets you select a full
Lightweight / portable.
range of welding output from 50 to 185 amps.
Full range, continuous welding output control with
a single knob.
As a generator it can supply up to surge watts or con-
Automatic shutdown under low oil level condition.
tinuous watts of 120 / 240 volt, single-phase AC power.
Hour Meter Standard.
The machine is portable.
Surge watts or Watts of continuous 120 / 240 volt
A Kohler CS 12.75 HP air cooled, OHV gasoline
single phase AC auxiliary power.
engine powers the welder / generator. It has an engine
Kohler CS 12.75 HP overhead cam air-cooled
warranty of 3 years.
gasoline engine. Smooth running, long life.
RECOMMENDED APPLICATIONS
WELDING CAPABILITY
Return to Section TOC
Return to Master TOC
OUTBACK 185
B-5 OPERATION B-5
CONTROLS AND SETTINGS All welder/generator controls are located on the Output Control Panel. Gasoline
Return to Section TOC
Return to Master TOC
engine controls are mounted on the engine. See Figure B.1 and the figures in engine operation section.
OUTPUT PANEL CONTROLS
10 1 9 7
12 2
8
11
Return to Section TOC
Return to Master TOC
6 5
3 or 4 FIGURE B.1
WELDER/GENERATOR CONTROLS 10. HOUR METER: Records the time that the engine has
See Figure B.1 for the location of the following features: run for maintenance purposes.
1. CURRENT CONTROL DIAL: Adjusts continuous cur-
11. ENGINE CHOKE: Engine starting aid.
rent output. The amperages on the dial correspond to
the approximate amperages needed for specific
Lincoln welding electrodes. 12. ENGINE SWITCH:
Used to start the engine, Select High Idle or Auto Idle
2. 30 AMP CIRCUIT BREAKER: Provide separate over-
load current protection for the 120 Volt and 240 Volt while the engine is running and stops the engine.
Receptacles When placed in the OFF position, the ignition
3. WELD POSITIVE OUTPUT TERMINAL: Provides the circuit is de-energized to shut down the engine.
Return to Section TOC
Return to Master TOC
OUTBACK 185
B-6 OPERATION B-6
Starting/Shutdown Instructions It is normal for any engine to use larger quantities of oil
until break-in is accomplished. Check the oil level
Be sure all Pre-Operation Engine Service has been twice a day during the break-in period (about 50 run-
performed. Also, Read owners manual before starting ning hours). Change the oil after the first 5 hours of
for the first time. (See INSTALLATION section) operation. See the Engine Instruction Manual for fur-
ther details.
Remove all loads connected to the AC power recepta-
cles. Before starting, first open the fuel shutoff valve. CAUTION
Always pull the choke control out when starting the IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE
engine; cold, warm or hot. UNIT SHOULD BE SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF THE MACHINE.
Turn the engine switch to the Start position and AVOID LONG IDLE RUNNING PERIODS. REMOVE
crank the engine until it starts, slowly return the choke LOADS AND ALLOW ENGINE TO COOL SEVERAL
control to the full in position (choke open), and turn MINUTES AT LOW IDLE BEFORE SHUTDOWN.
Return to Section TOC
-----------------------------------------------------------------------
Return to Master TOC
Stop the engine by placing the engine switch in the Typical Fuel Consumption
Off ( ) position.
KOHLER CS 12.75 HP
WARNING
Return to Section TOC
Close the fuel valve when the machine is 2250 R.P.M .75 ( LITERS/HOUR)
transported to prevent fuel leakage from NO LOAD .40 GALLONS/HOUR
the carburetor. 3750 R.P.M. 1.51 ( LITERS/HOUR)
------------------------------------------------------------------------
DC CC WELD OUTPUT .73 GALLONS/HOUR
100 AMPS, 25 VOLTS 2.77 ( LITERS/HOUR)
OUTBACK 185
B-7 OPERATION B-7
If you are welding for a long time, you may need to the purchase of a conversion kit. These products are
turn the dial slightly upward to maintain the same available where Lincoln products are sold. Contact your
results. local authorized Lincoln representative for more details.
The numbers on the dial correspond to the approxi-
mate amps needed to weld using specific Lincoln Plasma Cutting with Lincoln Pro-Cut 25.
welding rods. Table B.2, WELDING APPLICATIONS,
give you the recommended dial settings based on the The OUTBACK 185 generator power can be used to
thickness of the work and the size and type of rod supply up to 5,200 watts continuous input power to a Pro-
youre using. Cut 25. The Pro-Cut will work satisfactorily under the fol-
lowing conditions:
TO USE THE OUTBACK 185 FOR WELDING:
1. Remove the flange nuts from the weld output ter- 1. Set the Current Control on the OUTBACK 185 to the
minals and place the work and electrode welding 185 amp position. (Higher Settings may result in a
cables over the terminals. See Figure B.1 and shutdown of the Pro-Cut 25.)
B.1a. Replace and tighten the flange nuts
securely. Be sure the connections are tight. 2. Leave the "ON/OFF" switch on the Pro-Cut "OFF"
Return to Section TOC
Return to Master TOC
OUTBACK 185
B-8 OPERATION B-8
GENERAL INFORMATION NOTE: You can supply multiple loads as long as the
total load does not exceed 5700 Peak watts or
The OUTBACK 185 is rated at 5700 Peak watts or 5200 continuous watts. Be sure to start the
5200 continuous watts. It provides both 120 volt and largest loads first.
240 volt power. You can draw up to 20 amps from
either side of the 120 volt duplex receptacle, but not
more than 35.4 amps from both sides at once. Up to
Return to Section TOC
Return to Master TOC
TABLE B.2
ELECTRODE SELECTION GUIDE
CURRENT RANGE (AMPS)
AWS ELECTRODE
CLASSIFICATION ELECTRODE TYPE POLARITY
3/32 SIZE 1/8 SIZE 5/32 SIZE
E6010 FLEETWELD 5P DC+ 50-75 75-135 90-175
E6011 FLEETWELD 35 DC+ 50-75 70-110 80-145
E6011 FLEETWELD 180 DC+ 50-80 55-110 105-135
E6013 FLEETWELD 37 DC 70-95 100-135 145-180
E7018 EXCALIBUR 7018 DC+ 70-100 90-125 125-185
Return to Section TOC
E708-17 & E308L-17 BLUE MAX 308/308L AC-DC DC+ 50-80 75-110 95-150
ENi-CI SOFTWELD 99Ni DC+ 50-80 80-110 100-140
- WEARSHIELD ABR DC+ - 50-150 50-185
1/8 AND
SHEET THICKNESS THINNER 1/8 AND THICKER
OUTBACK 185
B-9 OPERATION B-9
TABLE B.3
Return to Section TOC
Return to Master TOC
Radio 50
*Refrigerator/Freezer (small) 600 1,500 - 2,400
Slow Cooker 200
*Submersible Pump - 1 HP 1,000 2,500 - 4,000
*Sump Pump 600 1,500 - 2,400
Toaster 1,100
Weed Trimmer 500
Lincoln Wire Feeder/Welder 4,000
NOTES:
Wattages listed are approximate. Check your equipment for actual wattage.
Equipment with unusually high *START-UP WATTS are listed. For start-up of other equipment that uses a
motor, listed in the table, multiply RUNNING WATTS by 2.
Return to Section TOC
Return to Master TOC
Multiple loads can be used as long as the total load does not exceed 5,700 Peak watts. Be sure to start
the largest loads first.
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-10
NOTES
OUTBACK 185
B-10
Return to Master TOC C-1 TABLE OF CONTENTS - ACCESSORIES SECTION C-1
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1
OUTBACK 185
C-2 ACCESSORIES C-2
OPTIONS/ACCESSORIES
Return to Section TOC
Return to Master TOC
OUTBACK 185
Return to Master TOC D-1 TABLE OF CONTENTS - MAINTENANCE SECTION D-1
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC D-2
OUTBACK 185
MAINTENANCE
D-2
D-3 MAINTENANCE D-3
------------------------------------------------------------------------
Read the Safety Precautions in the front of this manu-
al and in the Kohler Operating and Maintenance
OIL
Instructions manual before working on the OUT-
BACK185 Keep all equipment safety guards, covers,
and devices in position and in good repair. Keep your
hands, hair, clothing, and tools away from the recoil
housing, fans, and all other moving parts when start-
ing, operating, or repairing this machine.
Do not screw in FILL to FULL mark on
ROUTINE AND PERIODIC dipstick to check oil dipstick - recheck
MAINTENANCE
ENGINE MAINTENANCE 12 mm
HEX
Return to Section TOC
Return to Master TOC
CAUTION
To prevent the engine from accidentally starting, dis- Drain
plug
connect the spark plug lead before servicing the OIL DRAIN
PLUG
engine. Oil drain
Tighten dipstick
------------------------------------------------------------------------ firmly before starting
See the Kohler Owners manual for a summary of
maintenance intervals for the engine. Follow either the FUEL: At the end of each days use, refill
hourly or the calendar intervals, whichever come first. the fuel tank to minimize moisture conden-
More frequent service may be required, depending on sation and dirt contamination in the fuel
your specific application and operating conditions. The line.
Kohler Owners manual shows engine maintenance
replacement parts and numbers. AIR CLEANER: With normal operating
conditions, the maintenance schedule for
cleaning and re-oiling the foam pre-filter is
Return to Section TOC
Return to Master TOC
OUTBACK 185
D-4 MAINTENANCE D-4
FIGURE D.2
OPERATIONAL CLEARANCE
CAUTION
Approximately 12-18 of clearance should be
around this unit during operation for air flow.
Return to Section TOC
Return to Master TOC
WARNING
OVERSPEED IS HAZARDOUS - The maximum
allowable high idle speed for this machine is 3750
RPM, no load. Do NOT tamper with the governor
components or setting or make any other
adjustments to increase the maximum speed.
Severe personal injury and damage to the machine
can result if operated at speeds above maximum.
------------------------------------------------------------------------
Return to Section TOC
Return to Master TOC
OUTBACK 185
D-5 MAINTENANCE D-5
Return to Section TOC
Return to Master TOC
4
Return to Section TOC
Return to Master TOC
5
Return to Section TOC
Return to Master TOC
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC D-6
NOTES
OUTBACK 185
D-6
Return to Master TOC E-1 TABLE OF CONTENTS-THEORY OF OPERATION SECTION E-1
OIL LEVEL
CB1 CB3
OIL INDICATOR
LEVEL
CB2 CB4
MODULE
(KOHLER) REACTOR
OIL LEVEL AUXIIARY WINDINGS
Return to Master TOC
SWITCH
SLIP STATOR
_
RINGS
+ CHOKE +
WELD OUTPUT
RECTIFIER OUTPUT
IGNITION ENGINE ROTOR WINDINGS
(2 PHASE) STUDS
BRUSHES
STARTER / EXCITER
IDLE
SOLENOID ALTERNATOR SOLENOID WINDING
BOOST
10 AMP WINDING
FUSE
OFF
AUTO
HIGH
_ +
START
BATTERY
ENGINE
SHUTDOWN
RELAY OUTPUT
AUTOMATIC OUTPUT CONTROL
Return to Master TOC
HOUR
METER
FIELD / CONTROL PC BOARD
OUTBACK 185
E-2 THEORY OF OPERATION E-2
OIL LEVEL
CB1 CB3
OIL INDICATOR
LEVEL
CB2 CB4
MODULE
(KOHLER) REACTOR
OIL LEVEL AUXIIARY WINDINGS
SWITCH
SLIP STATOR
_
RINGS
+ CHOKE +
WELD OUTPUT
RECTIFIER OUTPUT
IGNITION ENGINE ROTOR WINDINGS
(2 PHASE) STUDS
BRUSHES
STARTER / EXCITER
IDLE
SOLENOID ALTERNATOR SOLENOID WINDING
BOOST
10 AMP WINDING
FUSE
OFF
AUTO
HIGH
_ +
Return to Section TOC
Return to Master TOC
START
BATTERY
ENGINE
SHUTDOWN
RELAY OUTPUT
AUTOMATIC OUTPUT CONTROL
IDLER CONTROL CIRCUIT
CIRCUIT
HOUR
METER
FIELD / CONTROL PC BOARD
ENGINE STARTING, PROTECTION If the battery is too low to properly power the starter
motor, the built-in recoil starter can be used to crank
AND BATTERY CHARGING the engine. (As long as the battery can produce 6 volts
or more, the engine ignition system will remain
ENGINE STARTING enabled.)
A 12 Volt battery supplies power to the rotary
run/stop/idle switch through a fuse that is located
Return to Section TOC
inside the control box. There is also a lead running volts available to activate the engine ignition system. If
from the fuse to the PC board. This is for battery the battery is removed or completely dead, the engine
charging only. will not start.
When the switch is placed in the Low Idle or High ENGINE PROTECTION
Idle position, a relay on the PC board is activated. The Kohler engine has a built-in oil level sensor that is
This relay activates the engine ignition system by connected to an oil level module. If the oil level is low,
opening a ground lead from the engine magneto. the ignition magneto is disabled. This will prevent the
engine from starting, or shut it down. Low oil level will
When the switch is held in the Start position, the also cause a warning light on the Outbacks control
starter motor solenoid is activated, cranking the panel to flicker for a few seconds when cranking the
engine. After the engine starts, the switch is released engine.
and returns to the high idle position.
Return to Section TOC
Return to Master TOC
OUTBACK 185
E-3 THEORY OF OPERATION E-3
OIL LEVEL
CB1 CB3
OIL INDICATOR
LEVEL
CB2 CB4
MODULE
(KOHLER) REACTOR
OIL LEVEL AUXIIARY WINDINGS
SWITCH
SLIP STATOR
_
RINGS
+ CHOKE +
WELD OUTPUT
RECTIFIER OUTPUT
IGNITION ENGINE ROTOR WINDINGS
(2 PHASE) STUDS
BRUSHES
STARTER / EXCITER
IDLE
SOLENOID ALTERNATOR SOLENOID WINDING
BOOST
10 AMP WINDING
FUSE
OFF
AUTO
HIGH
_ +
Return to Section TOC
Return to Master TOC
START
BATTERY
ENGINE
SHUTDOWN
RELAY OUTPUT
AUTOMATIC OUTPUT CONTROL
IDLER CONTROL CIRCUIT
CIRCUIT
HOUR
METER
FIELD / CONTROL PC BOARD
ENGINE STARTING, PROTECTION NOTE: The engine charging system must be function-
al for the Outback 185 to produce weld or auxiliary
AND BATTERY CHARGING (contin- output.
ued)
NOTE: The battery must remain connected at all times.
If the battery is disconnected while the machine is run-
BATTERY CHARGING
Return to Section TOC
The Kohler engine has a built-in battery charging sys- likely cause the PC board electronics to malfunction
tem. Output from the charging system is applied to the and may cause permanent damage to the PC board.
PC board where it is stabilized by the battery and then
used to power the board electronics, the generator
flashing system, and the hour meter. The remaining
output exits the PC board, is routed through a fuse
located inside the control box, and applied to the bat-
tery.
Return to Section TOC
Return to Master TOC
OUTBACK 185
E-4 THEORY OF OPERATION E-4
OIL LEVEL
CB1 CB3
OIL INDICATOR
LEVEL
CB2 CB4
MODULE
(KOHLER) REACTOR
OIL LEVEL AUXIIARY WINDINGS
SWITCH
SLIP STATOR
_
RINGS
+ CHOKE +
WELD OUTPUT
RECTIFIER OUTPUT
IGNITION ENGINE ROTOR WINDINGS
(2 PHASE) STUDS
BRUSHES
STARTER / EXCITER
IDLE
SOLENOID ALTERNATOR SOLENOID WINDING
BOOST
10 AMP WINDING
FUSE
OFF
AUTO
HIGH
_ +
Return to Section TOC
Return to Master TOC
START
BATTERY
ENGINE
SHUTDOWN
RELAY OUTPUT
AUTOMATIC OUTPUT CONTROL
IDLER CONTROL CIRCUIT
CIRCUIT
HOUR
METER
FIELD / CONTROL PC BOARD
AUTOMATIC IDLE SYSTEM Weld and auxiliary current are detected by a toroidal
current sensor that is connected to the PC board.
The Outback 185 is equipped with an automatic When sufficient current flows through the sensor; the
engine idle system. A solenoid is used to pull the PC board detects this and immediately interrupts the
engine throttle to a preset low speed position when 12 negative (-) connection to the solenoid. The solenoid
volts DC is applied. When no voltage is applied, the is released and the engine RPM increases to the high
Return to Section TOC
OUTBACK 185
E-5 THEORY OF OPERATION E-5
OIL LEVEL
CB1 CB3
OIL INDICATOR
LEVEL
CB2 CB4
MODULE
(KOHLER) REACTOR
OIL LEVEL AUXIIARY WINDINGS
SWITCH
SLIP STATOR
_
RINGS
+ CHOKE +
WELD OUTPUT
RECTIFIER OUTPUT
IGNITION ENGINE ROTOR WINDINGS
(2 PHASE) STUDS
BRUSHES
STARTER / EXCITER
IDLE
SOLENOID ALTERNATOR SOLENOID WINDING
BOOST
10 AMP WINDING
FUSE
OFF
AUTO
HIGH
_ +
Return to Section TOC
Return to Master TOC
START
BATTERY
ENGINE
SHUTDOWN
RELAY OUTPUT
AUTOMATIC OUTPUT CONTROL
IDLER CONTROL CIRCUIT
CIRCUIT
HOUR
METER
FIELD / CONTROL PC BOARD
GENERATING POWER high position, all of the windings should be putting out
maximum voltage almost immediately. The rotor field
Flashing voltage is now considerably higher than the flashing
When the engine is running, power from the engine voltage that was used to start the generating process.
charging system is stabilized, and then applied to the The flashing diode on the control PC board blocks
rotor brushes through a series of PC board mounted that higher field voltage from intruding into the 12VDC
Return to Section TOC
battery system.
Return to Master TOC
OUTBACK 185
E-6 THEORY OF OPERATION E-6
OIL LEVEL
CB1 CB3
OIL INDICATOR
LEVEL
CB2 CB4
MODULE
(KOHLER) REACTOR
OIL LEVEL AUXIIARY WINDINGS
SWITCH
SLIP STATOR
_
RINGS
+ CHOKE +
WELD OUTPUT
RECTIFIER OUTPUT
IGNITION ENGINE ROTOR WINDINGS
(2 PHASE) STUDS
BRUSHES
STARTER / EXCITER
IDLE
SOLENOID ALTERNATOR SOLENOID WINDING
BOOST
10 AMP WINDING
FUSE
OFF
AUTO
HIGH
_ +
Return to Section TOC
Return to Master TOC
START
BATTERY
ENGINE
SHUTDOWN
RELAY OUTPUT
AUTOMATIC OUTPUT CONTROL
IDLER CONTROL CIRCUIT
CIRCUIT
HOUR
METER
FIELD / CONTROL PC BOARD
GENERATING POWER
(continued)
DC Weld Output Weld Boost:
AC output from the two phase-shifted weld windings The Outback 185 is equipped with a weld boost cir-
pass through a reactor then to a two-phase bridge rec-
Return to Section TOC
tifier. DC output from the rectifier is then stabilized by tains a weld boost winding that produces output rela-
a choke and terminates at two weld output terminals. tive to the weld current. In high welding load situations,
the exciter winding will tend to drop off in output while
Weld Output Control the boost windings output tends to increase. The out-
Weld output is controlled by varying the current in the put from this boost winding is routed through a circuit
rotating field winding. This is done through circuitry on breaker. It is then rectified and added to the exciter cir-
the PC board that detects the position of the output cuit, resulting in a significant improvement in weld per-
control potentiometer and then limits the rotor current formance.
accordingly.
OUTBACK 185
Return to Master TOC F-1 TABLE OF CONTENTS - TROUBLESHOOTING AND REPAIR F-1
OUTBACK 185
F-2 TROUBLESHOOTING AND REPAIR F-2
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained
Personnel. Unauthorized repairs performed on this equipment may result in danger to
the technician and machine operator and will invalidate your factory warranty. For your
safety and to avoid Electrical Shock, please observe all safety notes and precautions
detailed throughout this manual.
---------------------------------------------------------------------------------------------------------------------------
This Troubleshooting Guide is provided to Step 3. RECOMMENDED
help you locate and repair possible machine COURSE OF ACTION
malfunctions. Simply follow the three-step The last column labeled Recommended
procedure listed below. Course of Action lists the most likely com-
ponents that may have failed in your
Step 1. LOCATE PROBLEM(SYMPTOM). machine. It also specifies the appropriate
Return to Section TOC
Return to Master TOC
Look under the column labeled PROBLEM test procedure to verify that the subject com-
(SYMPTOMS). This column describes pos- ponent is either good or bad. If there are a
sible symptoms that the machine may exhib- number of possible components, check the
it. Find the listing that best describes the components in the order listed to eliminate
symptom that the machine is exhibiting. one possibility at a time until you locate the
Symptoms are grouped into the following cause of your problem.
categories: output problems.
All of the referenced test procedures
Step 2. PERFORM EXTERNAL TESTS. referred to in the Troubleshooting Guide are
The second column labeled POSSIBLE described in detail at the end of this chapter.
AREAS OF MISADJUSTMENT(S) lists the Refer to the Troubleshooting and Repair
obvious external possibilities that may con- Table of Contents to locate each specific
tribute to the machine symptom. Perform Test Procedure. All of the specified test
these tests/checks in the order listed. In points, components, terminal strips, etc. can
general, these tests can be conducted with- be found on the referenced electrical wiring
out removing the case wrap-around cover. diagrams and schematics. Refer to the
Electrical Diagrams Section Table of
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the
tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting
assistance before you proceed. Call 1-888-935-3877.
-----------------------------------------------------------------------------------------------------------------------------------
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-3 TROUBLESHOOTING AND REPAIR F-3
PC board can be damaged by static electricity. b. If the original problem is recreated by the
- Remove your bodys static substitution of the original board, then the PC
charge before opening the static- board was the problem. Reinstall the
shielding bag. Wear an anti-static replacement PC board and test the machine.
wrist strap. For safety, use a 1 6. Always indicate that this procedure was
Meg ohm resistive cord connected followed when warranty reports are to be
ATTENTION to a grounded part of the submitted.
Static-Sensitive equipment frame.
NOTE: Following this procedure and writing on the
Devices - If you dont have a wrist strap, warranty report, INSTALLED AND SWITCHED PC
Handle only at touch an un-painted, grounded,
BOARDS TO VERIFY PROBLEM, will help avoid
Static-Safe part of the equipment frame. Keep denial of legitimate PC board warranty claims.
Workstations touching the frame to prevent
static build-up. Be sure not to
touch any electrically live parts at
the same time.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-4 TROUBLESHOOTING AND REPAIR F-4
OUTPUT PROBLEMS
Major physical or electrical Contact the Lincoln Electric
damage. Service Department at 1-888-935-
3877.
The engine will not crank while 1. Be certain that the battery is 1. Test the fuse located under the
using the electric start function. properly connected and white cover at the back of the
adequately charged. control box.
2. Try cranking the engine using 2. Test for battery voltage at lead
the recoil starter. If the engine 210B where it connects to the
will still not turn, or the recoil starter solenoid, while holding
Return to Section TOC
Engine will not start. The starter 1. If using the recoil starter, be 1. Check for battery voltage at the
motor will crank the engine sure the engine switch is in the PC board pin J3-10. (lead #211)
normally. high or auto position. If voltage is not resent, the
Return to Section TOC
Return to Master TOC
replace if necessary.
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-5 TROUBLESHOOTING AND REPAIR F-5
OUTPUT PROBLEMS
(Continued) 8. Observe the oil level indicator Reconnect P4/J4 to shut the
light while cranking the engine. engine down.
If the light is blinking while
cranking the engine, the oil level Attempt to start the engine
may be low, or the oil level using the recoil starter; if the
system may be faulty. Contact engine starts, check lead #212
the engine manufacturer. for faulty insulation. If lead
#212 is good, replace the PC
board.
The engine will not shut down. 1. Place the engine switch in the
stop position and check for
battery voltage at the PC board
pin J3-10. (lead #211) If
voltage is present, the switch is
defective.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-6 TROUBLESHOOTING AND REPAIR F-6
OUTPUT PROBLEMS
The engine runs erratically or 1. Check that the fuel valve is fully 1. Check the idle solenoid and
stops running. open, and that there is engine carburetor linkage for
sufficient, fresh gasoline in the damage, excessive dirt, or
tank. binding. If possible, perform
the engine RPM adjustment
2. The choke may be engaged. procedure.
Be sure the choke handle is
pushed in completely after the 2. Place the engine switch in the
engine has begun to warm up. stop position, unplug engine
to welder harness connector
3. Be certain that the battery is (P4/J4) located inside the
properly connected and control box at the bottom left.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-7 TROUBLESHOOTING AND REPAIR F-7
OUTPUT PROBLEMS
Engine will not idle down. Weld 1. Check that the engine switch is 1. The idle solenoid may be
and auxiliary outputs are normal. in the Auto position. improperly adjusted. Perform
the Engine RPM adjustment
2. Check that the engine choke is procedure.
fully open.
2. With the engine running, place
3. There may be a load on the the engine switch in the Auto
weld or auxiliary output. position. Check for battery
Disconnect all cables and cords. voltage at the idle solenoid,
lead 213B. if battery voltage is
not present, check engine
switch, connector P4/J4, and
Return to Section TOC
Return to Master TOC
Engine idles own but will not stay Low idle ROM may be set too low.
at low idle. Perform the engine RPM
adjustment procedure.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-8 TROUBLESHOOTING AND REPAIR F-8
OUTPUT PROBLEMS
The engine will not go to high idle 1. Poor connection in weld circuit; 1. Unplug P4/J4 connector and
when a welding or auxiliary load check cables, connectors, work measure the idle solenoid
is applied. Engine idles up clamp and electrode holder. resistance between leads
normally and outputs are normal Check that work clamp is 213B and 215A. it should
when the engine switch is placed making a good connection to measure about 15 ohms.
in the high position. the work piece. Measure the resistance from
lead 213B or lead 215A to
2. Load too low to activate the idle chassis ground. Resistance
circuit. Plug in a device that should be very high; 500,000
applies a load of 100 watts or (500K) ohms or higher.
more. Replace the solenoid if the
resistance is significantly
Return to Section TOC
Return to Master TOC
Engine runs normally. the machine. Disconnect all be worn or faulty. Perform the
cables and cords from the weld brush and slip ring service
output terminals and the procedure.
auxiliary receptacles. Check for
2. With the engine running, check
DC open circuit voltage (OCV)
for battery voltage at the PC
(About 70 to 80 volts) at the
board, J3-9 (lead #208A). If
weld output terminals and check
voltage is not present, check
for AC auxiliary voltage at the
conductors and connection at
120 and 240 VAC receptacles.
leads 208A, 208, and the
2. Check that circuit breakers are engine wiring leading to the
not tripped. engine charging system. If the
connections are good, the
battery charging system may
be faulty. Contact a qualified
engine repair technician.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-9 TROUBLESHOOTING AND REPAIR F-9
OUTPUT PROBLEMS
(Continued) 3. If voltage is present at J3-9, check
for battery voltage at J3-8 (lead
#224A). If voltage is not present,
replace the PC board.
4. If voltage is present at J3-8,
check for battery voltage at J1-
9 (lead #224). If voltage is not
present, check leads 224 and
224A. Check the positive
terminal connections at the
hour meter.
Return to Section TOC
Return to Master TOC
There is no weld output, or weld 1. Check weld cables, 1. Check for loose or damaged
voltage drops dramatically when connections, work clamps, and connections between the
trying to strike an arc. The electrode holder. output terminals, the choke,
115/230 VAC auxiliary output is the rectifier, the rector, and the
normal; engine operates 2. With engine running at high
stator. See wiring diagram.
idle, and output control set to
Return to Section TOC
normally.
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-10 TROUBLESHOOTING AND REPAIR F-10
OUTPUT PROBLEMS
(Continued) 4. With the engine still running,
check for about 70 to 80 VDC
at the output rectifier positive
and negative terminal. If
voltage is not present, the
rectifier is probably faulty.
No 115/230 VAC auxiliary output 1. Check for faulty extension 1. Check for AC voltage at the
Weld output is normal and engine cords, tools, lights, etc. Plug in back of the receptacles. If
operates normally. a known working device. voltage is present at the back
of the receptacles but the
2. Check for tripped circuit receptacles still will not
breakers. function, replace the
3. If the Outback has optional receptacle.
GFCI receptacles, try resetting 2. Check for 120 VAC from lead
them. #5 to leads #3 and #6 at the
NOTE: Engine must be running at circuit breakers. See wiring
high idle RPM or the GFCI diagram. If 120 VAC is
receptacles will not reset. present, one or more circuit
breakers may be defective.
Low weld and auxiliary output, 1. The output control may be set 1. Perform the Engine RPM
the engine operates normally. too low. adjustment procedure.
2. Engine RPM may be low. 2. The brushes and slip rings may
be worn or faulty. Perform the
3. The battery may be faulty. brush and slip ring service
procedure.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
F-11 TROUBLESHOOTING AND REPAIR F-11
OUTPUT PROBLEMS
The welding arc is cold or weld 1. The weld boost circuit breaker 1. Perform the Engine RPM
performance is poor. Engine may have tripped. This circuit adjustment procedure.
operates normally and auxiliary breaker is a small button on the
output is normal. bottom of the control box, not 2. The brushes and slip rings
far from the positive weld output may be worn or faulty. Perform
terminal. the brush and slip ring
service procedure,
2. Check the weld cables,
electrode holder, and work 3. Perform the battery and
clamp. Try welding with a charging system tests.
known good set of short, 4. Perform the weld boost
adequately sized cables. circuit tests.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12
NOTES
OUTBACK 185
F-12
F-13 TROUBLESHOOTING AND REPAIR F-13
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
Test will determine whether the engine is operating at the correct speed (RPM) during
both HIGH and LOW idle conditions.
MATERIALS NEEDED
Miscellaneous hand tools and metric wrench set
High visibility marker
Strobe-tach, frequency counter, or vibratach
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-14 TROUBLESHOOTING AND REPAIR F-14
FAN BLADE
Return to Section TOC
Return to Master TOC
STROBE-TACH MARK
Return to Section TOC
Return to Master TOC
PROCEDURE
Strobe-Tach Method
1. Turn the engine off. 7. Move the idle switch to the AUTO IDLE posi-
tion and wait for the idle solenoid to energize.
2. Place a highly visible mark on a component that The engine RPM should drop and stabilize at
rotates while the engine is running. The rotor- the low idle RPM.
cooling fan is a good place for this mark. See
Figure F.1. 8. Synchronize the strobe-tach to read the low idle
RPM.
3. Connect the strobe-tach according to the man-
ufacturers instructions. 9. The tach should read between 2250 and 2500
RPM.
4. Start the engine and place the idle switch in the
HIGH IDLE position. Make sure that there is 10. If either of the readings is incorrect, proceed to
no load on the machine. the Throttle Adjustment Procedure in this
Return to Section TOC
Return to Master TOC
section.
5. Direct the strobe-tach light at the mark and syn-
chronize the strobe-tach.
6. The tach should read between 3700 and 3800
RPM.
OUTBACK 185
F-15 TROUBLESHOOTING AND REPAIR F-15
INCREASE DECREASE
(RPM) (RPM)
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-16 TROUBLESHOOTING AND REPAIR F-16
Vibratach Method
A Vibratach is used to measure the vibrations 4. Move the idle switch to the AUTO IDLE posi-
caused by the running engine. It can be positioned tion and wait for the idle solenoid to energize,
anywhere where the engine vibration is reasonably and the engine RPM to drop and stabilize at the
strong. low idle RPM.
1. Read and understand the manufacturers 5. Position and adjust the Vibratach; it should read
instructions for the Vibratach. between 2250 and 2500 RPM.
2. Start the engine and place the idle switch in the 6. If either of the readings is incorrect, proceed to
HIGH IDLE position. Make sure there is no the Throttle Adjustment Procedure later in
load on the machine. this section.
OUTBACK 185
F-17 TROUBLESHOOTING AND REPAIR F-17
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This procedure will aid the technician in the adjustment of the throttle.
MATERIALS NEEDED
Flathead Screw
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-18 TROUBLESHOOTING AND REPAIR F-18
PROCEDURE
Check that the linkage attaching the solenoid to the 1. With engine running and no load applied to the
engine speed control lever is in good condition and machine, place the engine switch in the AUTO
moves freely. IDLE position. Wait for the idle solenoid to
energize and the engine speed to drop and sta-
1. Start the engine and place the engine switch in bilize at low idle RPM.
the HIGH IDLE position. The solenoid should
be de-energized. Be certain that there is no 2. If the low idle RPM requires adjustment, turn
load on the machine. the low idle adjustment screw. See Figure F.4.
The low idle RPM should be between 2250 and
2. If the high idle RPM requires adjustment, using 2500 RPM.
flathead screw turn the high idle adjustment
screw. See Figure F.4. Turning the screw
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-19 TROUBLESHOOTING AND REPAIR F-19
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
PROCEDURE DESCRIPTION
This procedure provides guidance in testing and maintaining the brush and slip ring sys-
tem.
MATERIALS NEEDED
500 or 600 grit emery cloth
220 or 320 grit commutator stone (Optional)
Needlenose Pliers
1/4 Nut Driver
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-20 TROUBLESHOOTING AND REPAIR F-20
SCREWS (2)
LOCKING TABS
Return to Section TOC
Return to Master TOC
COVER
PROCEDURE
1. Remove the brush cover from the end of the 6. The brushes should be of sufficient length and
generator. have adequate spring tension. Generally, the
brushes should be replaced if either brush has
2. Pry outward at the top of the plastic brush cover less than 1/4 remaining before it reaches the
while depressing the two locking tabs at the end of its travel. Spring tension should be suf-
sides of the cover. See Figure F.5. ficient to hold the brushes firmly against the slip
3. Remove the brush and brush holder assembly. rings.
4. Use needle-nose pliers to remove the leads 7. The brushes should be removed from the brush
from the brush terminals, and then use the 1/4 holder and be examined. The terminals should
nut driver to remove the two screws holding the be clean. The shunt, (braided lead connecting
brush holder in place. The brush holder assem- the carbon brush to the terminal) should be in
bly can now be pulled straight out from the end good condition and firmly connected to the car-
of the generator toward the front of the bon brush and to the connection terminal.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-21 TROUBLESHOOTING AND REPAIR F-21
CABLE TIE
Return to Section TOC
Return to Master TOC
BRUSHES
Return to Section TOC
Return to Master TOC
9. Check for evidence of sticking brushes. 2. Use low-pressure compressed air to thoroughly
Sticking brushes will normally result in the slip blow the carbon, commutator stone and sand-
rings being pitted and discolored from exces- paper dust from the machine before operating.
sive arcing. Another sign of sticking brushes is
3. To install the brush holder assembly, push the
instability or loss of both weld and auxiliary out-
brushes into the brush holder assembly and
put, but the machine may also begin to work
place a plastic cable tie through the holes pro-
properly for a short time after being jarred or
vided. See Figure F.6.
moved.
4. Slide the brush holder assembly back into the
10. If there is any evidence that the brushes may
generator and secure with the two screws
have been sticking in the brush holders, a new
removed earlier. Reattach the leads and
brush holder and brush assembly should be
remove the cable tie. Replace the plastic gen-
installed.
erator cover.
Cleaning Slip Rings
1. In the event that the slip rings have become
Return to Section TOC
Return to Master TOC
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-22
NOTES
OUTBACK 185
F-22
F-23 TROUBLESHOOTING AND REPAIR F-23
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test will determine if correct voltage is being applied to the rotor slip rings.
MATERIALS NEEDED
Misc. hand tools
Multimeter
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-24 TROUBLESHOOTING AND REPAIR F-24
SLIP RINGS
BRUSHES
Return to Section TOC
Return to Master TOC
+
-
Return to Section TOC
Return to Master TOC
PROCEDURE
1. Be certain the battery is fully charged and the 9. Check for battery voltage at lead 224 (J1-9).
battery charging system is functioning normally. Check that the PC board is properly grounded
at lead GND-G (J1-2). If the board is getting
2. Ensure that there is no load on either the weld battery voltage and is properly grounded,
or auxiliary outputs. replace the board.
3. Set the output control to maximum. 10. If the voltage reading is about 3 to 5 volts DC,
4. Remove the plastic brush cover from the end of check for AC voltage between Lead #7
the generator. See Brush and Slip Ring (Terminal B2) and Lead #9 (Terminal B1). If
Service Procedure. the voltage is about the same or higher than
the voltage reading of the brush leads, replace
5. Attach voltmeter leads to the brush terminals. the board.
(The positive terminal is closest to the genera-
tor winding) 11. If the AC voltage between leads #7 and #9 is
significantly lower than the DC voltage on the
Return to Section TOC
Return to Master TOC
6. Start the engine and place the engine switch in brush leads, perform the Stator Short Circuit
the HIGH position. and Ground Test and Stator Voltage Test.
7. The voltmeter should read about 50 VDC.
8. If the voltage reading is zero or near zero, per-
form the Rotor Resistance Test.
OUTBACK 185
F-25 TROUBLESHOOTING AND REPAIR F-25
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test will determine if the battery charging system is functioning properly.
MATERIALS NEEDED
Misc. hand tools
Multimeter
Jumper lead with a 10-amp inline fuse or circuit breaker
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-26 TROUBLESHOOTING AND REPAIR F-26
BATTERY
Return to Section TOC
Return to Master TOC
-
+
Return to Section TOC
Return to Master TOC
PROCEDURE
WARNING
4. Disconnect lead #208 from the engine alterna-
DO NOT REMOVE BATTERY tor and place a fused jumper lead between the
CABLE WHILE MACHINE IS RUN- alternator and the positive battery terminal.
NING, OR ATTEMPT TO OPERATE See Figure F.8. See wiring diagram.
THE ENGINE WITHOUT A BAT-
TERY CONNECTED. Serious dam- 5. Start the engine and check voltage at the bat-
age to the PC board may result. tery. If the DC voltage is now 13.5 to 14.5,
check leads 208, 208A, and lead 209. If these
1. Be sure the battery is fully charged, in good leads and connections are good, replace the
condition and is securely connected. board.
2. Start the engine and test the voltage at the bat- 6. If the voltage is still low, or if the inline fuse
tery terminals. The meter should read between blows, the engine charging system is most like-
13.5 and 14.5 volts DC. ly faulty. Contact a qualified engine repair tech-
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-27 TROUBLESHOOTING AND REPAIR F-27
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test determines if the stator is producing the correct voltage from each of the wind-
ings. This test should be performed if rotor voltage is normal but one or more of the out-
put voltage readings are incorrect.
MATERIALS NEEDED
Miscellaneous hand tools
Wiring diagram
Multimeter
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-28 TROUBLESHOOTING AND REPAIR F-28
PROCEDURE
1. Verify that the engine RPM is normal. See the 5. If the voltage is not present or is significantly dif-
Engine RPM Adjustment Procedure. ferent from expected readings, check the wiring
between test points and the stator winding. See
2. Start the machine and place the idle switch in wiring diagram. If the wiring is in good condi-
the high position. See Figure F.9. tion, the stator is defective.
3. Check for AC voltage between the neutral stud *Voltage shown is for a stator that is at normal full
on the control panel bottom and the #3 lead load temperature. Readings will likely be slightly
connection at the CB1 circuit breaker. Also higher if machine is cold.
check the voltage between the neutral stud and
the #6 lead connection at the CB1 circuit break-
er. Voltage should read between 115 and 130*
volts. See wiring diagram.
4. Check for AC voltage between leads W1 and
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-29 TROUBLESHOOTING AND REPAIR F-29
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test will determine if the rotor winding is open, shorted or grounded.
MATERIALS NEEDED
Miscellaneous hand tools
Ohmmeter (analog type meter required for dynamic resistance test)
Wiring Diagram
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-30 TROUBLESHOOTING AND REPAIR F-30
SLIP RINGS
BRUSHES
Return to Section TOC
Return to Master TOC
+
-
Return to Section TOC
Return to Master TOC
PROCEDURE
1. Turn the engine off. 6. Measure the resistance to ground. Place one
meter probe on either of the slip rings. Place
2. Remove the plastic cover from the end of the the other probe on any good, unpainted chassis
generator. See Brush and Slip Ring Service ground. The resistance should be very high, at
Procedure. least 500,000 (500k) ohms.
3. Using needle-nose pliers, remove the leads 7. If the test does not meet the resistance specifi-
from the brush terminals. This will electrically cations, then the rotor may be faulty and should
isolate the rotor windings. be replaced.
4. Remove the brush and brush holder assembly. 8. If this test meets resistance specifications, con-
See Brush and Slip Ring Service Procedure. tinue testing using the Dynamic Rotor
5. Using the ohmmeter, check the rotor winding Resistance and Ground Test.
resistance across the slip rings. Normal resis- *Voltage shown is for a stator that is at normal full
tance is approximately 9* ohms, at 77F. load temperature. Readings will likely be slightly
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-31 TROUBLESHOOTING AND REPAIR F-31
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test will aid the technician in checking for faults in the rotor winding.
MATERIALS NEEDED
Analog Ohmmeter
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-32 TROUBLESHOOTING AND REPAIR F-32
SLIP RINGS
BRUSHES
Return to Section TOC
Return to Master TOC
+
-
Return to Section TOC
Return to Master TOC
1. This test requires that the brushes and slip rings 7. Restart the engine and run it at high idle speed.
are clean, in good condition, and are properly The resistance should be very high, at least
seated. 500,000 (500k) ohms.
2. Perform the Brush and Slip Ring Service 8. If the resistance readings differ significantly
Procedure. Then reinstall the brush holder and from the values indicated, re-check the brushes
brush assembly. and the brush spring tension. If the brushes
and slip rings are good, replace the rotor.
3. Insulate the lead wires that had been discon-
nected from the brushes during the static rotor 9. Re-attach the brush leads and install the brush
Return to Section TOC
Return to Master TOC
4. Securely attach the ohmmeter leads to the *NOTE: The resistance of the copper windings will
brush terminals. Use clips or terminals to change the temperature. Higher temper-
attach the leads BEFORE starting the engine. atures will produce higher resistance, and
See Figure F.11. lower temperatures will produce lower
resistance.
OUTBACK 185
F-33 TROUBLESHOOTING AND REPAIR F-33
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test will determine if there are undesirable electrical connections between the stator
windings and chassis ground, or between individual windings within the stator. This test
should be performed if flashing voltage is present at the rotor slip rings, but the voltage
output on leads #7 and #9 is too low.
MATERIALS NEEDED
Miscellaneous hand tools
Ohmmeter
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-34 TROUBLESHOOTING AND REPAIR F-34
5. Disconnect the #7 and #9 leads from the PC b) The #5 lead that had been disconnected
Return to Section TOC
Return to Master TOC
If any of these readings are less than 500,000 (500k) ohms, check for damaged, contaminated, or
(500k) ohms, check for grounded components or shorted wiring, or defective components connected
wiring that remain connected to the stator, such as to the stator windings. If necessary, disconnect
circuit breakers, receptacles, output rectifier, reac- and isolate leads as close to the stator winding as
tor, etc. See Wiring Diagram. If necessary, dis- possible. See Wiring Diagram. If the low resis-
connect and isolate the stator leads as close to the tance is determined to be between the windings
stator winding as possible. If the low resistance to within the stator, the stator is defective and should
ground is determined to be in the stator windings, be replaced.
the stator is defective and should be replaced.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-35 TROUBLESHOOTING AND REPAIR F-35
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This test checks the functionality of the weld boost system. This test should be done if
the weld terminal open circuit voltage and engine RPM are normal, but the machine weld
output is low.
MATERIALS NEEDED
Resistive load bank
Misc. hand tools
Multimeter
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-36 TROUBLESHOOTING AND REPAIR F-36
PROCEDURE
1. Check that the CB4 circuit breaker is not tripped. 10. Start the engine and apply a load of about 80
to 100 Amps.
2. Check that the battery is fully charged and in
good condition. 11. Check for AC voltage between leads 13 and 14
at the PC board. See wiring diagram.
3. Set the output dial to the Maximum position.
12. If voltage is present, rotate the output control
4. Start the engine and place the engine switch in knob and observe the voltage between leads
the High idle position. 13 and 14. The voltage should rise and fall as
5. Verify that the engine RPM is correct. See the the output control is moved.
Engine RPM adjustment procedure. 13. If the voltage at leads 13 and 14 is responding
6. Turn on the load bank and adjust to get a 165 to as described above, the PC board is probably
190 Amp load. defective.
7. Check engine RPM, it should not fall below 3300 14. If no significant voltage is detected at leads 13
RPM. and 14, and if the voltage does not respond to
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-37 TROUBLESHOOTING AND REPAIR F-37
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This procedure will aid the technician in the removal and replacement of the case sheet
metal covers.
MATERIALS NEEDED
3/8 Wrench
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-38 TROUBLESHOOTING AND REPAIR F-38
CASE SCREWS
Return to Section TOC
Return to Master TOC
CASE SCREWS
Return to Section TOC
Return to Master TOC
PROCEDURE
1. Using a 3/8 wrench, remove all screws from
the top of the red sheet metal cover.
2. Lift the top cover off of the machine
3. To replace the cover, reverse the above proce-
dure.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-39 TROUBLESHOOTING AND REPAIR F-39
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This procedure will aid the technician in the removal and replacement of the fuel tank
enclosure.
MATERIALS NEEDED
Approved gasoline container and pump
7/16 Wrench
Rags
Pliers
3/8 Wrench
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-40 TROUBLESHOOTING AND REPAIR F-40
FUEL TANK
3/8 SCREWS
Return to Section TOC
Return to Master TOC
3/8 SCREWS
PROCEDURE
WARNING
5. Using pliers, remove fuel line clamp located on
Because gasoline is highly gasoline valve.
flammable, the following
procedures should be done in 6. Carefully remove the fuel line from the gasoline
a well-ventilated area; far valve.
away from flame, sparks, or 7. Flex the end of the sheet steel fuel tank enclo-
any other sources of ignition. sure out slightly and lift the tank out of the
machine.
1. Perform the Case Cover Removal Procedure.
8. If access to the top of the engine is required,
2. Close gasoline valve. Red Lever located on using the 3/8 wrench, remove the five screws
bottom of gas tank. holding the bottom of the fuel tank enclosure
3. Using a 7/16 wrench, disconnect the negative and lift it out of the machine.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-41 TROUBLESHOOTING AND REPAIR F-41
MOUNTING BRACKET
Return to Section TOC
Return to Master TOC
-
+
BATTERY
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-42
NOTES
OUTBACK 185
F-42
F-43 TROUBLESHOOTING AND REPAIR F-43
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
TEST DESCRIPTION
This procedure will aid the technician in the removal and replacement of the control box.
MATERIALS NEEDED
Cable Ties
Wire Marking Supplies
Wiring Diagram
Phillips Screwdriver
3/8 Wrench
7/16 Wrench
Needle Nose Pliers
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-44 TROUBLESHOOTING AND REPAIR F-44
FUEL TANK
CONTROL BOX
Return to Section TOC
Return to Master TOC
PROCEDURE
1. Perform the Case Cover Removal Procedure. 9. Using the wiring diagram, identify all of the
wires, wire splices, and plugs that connect con-
2. Using the 7/16 wrench, loosen battery mount- trol box components to the engine and genera-
ing bracket. See Figure F.16. tor. If any wire or connector is not clearly
3. Remove the battery. marked, mark them so they can be properly
reconnected. It is also helpful to make notes as
4. Perform the Fuel Tank and Enclosure Removl needed.
Procedure.
10. Cut cable ties as needed and disconnect
5. Disconnect the spark plug wire to prevent acci- these wires.
dental starting of the engine.
11. Remove any remaining 3/8 screws from left
6. Replace three of the screws that had been side of the control box and gently lift the con-
removed when the fuel tank enclosure bottom trol box off the generator assembly.
was removed. These screws are used to tem-
12. Reverse the above procedure to reassemble.
Return to Section TOC
Return to Master TOC
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-45
MOUNTING BRACKET
+
-
OUTBACK 185
BATTERY
FIGURE F.17 BATTERY LOCATION
TROUBLESHOOTING AND REPAIR
CONTROL BOX REMOVAL AND REPLACEMENT PROCEDURE (continued)
F-45
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-46
NOTES
OUTBACK 185
F-46
F-47 TROUBLESHOOTING AND REPAIR F-47
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the stator.
MATERIALS NEEDED
1/2 Wrench
7/16 Wrench
Hoist
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-48 TROUBLESHOOTING AND REPAIR F-48
HAMMER TAPPING
POINTS
TOLERANCE RING
BRUSH ASSEMBLY
Return to Section TOC
Return to Master TOC
PROCEDURE
1. Perform the Control Box Removal Procedure. 6. Using a 7/16 wrench, remove the four bolts
connecting the cast stator brackets. Note the
2. Remove the brushes. See the Brush and Slip precise position of all hardware components
Ring Service Procedure. and washers. Using a plastic hammer, gently
3. Label and disconnect any wiring connecting the and evenly tap outward on the end cast brack-
engine/generator assembly to the tubular et. See Figure F.18.
frame. Remove cable ties and flexible plastic The stator frame assembly can now be carefully
conduit as needed. See wiring diagram. removed.
4. Using the 1/2 wrench, remove the nuts secur- IMPORTANT: Handle and store the stator careful-
ing the generator and engine to the rubber ly to avoid damage to the windings.
mounts. Note ground lead and washer place-
ment for reassembly. See Figure F.19.
5. Use a hoist or get a helper and lift the engine
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-49 TROUBLESHOOTING AND REPAIR F-49
OUTBACK 185
F-50 TROUBLESHOOTING AND REPAIR F-50
TOLERANCE RING
Return to Section TOC
Return to Master TOC
STATOR
Return to Section TOC
Return to Master TOC
10. Check the air gap between the rotor and the
stator. Feeler gages are inserted between the
rotor and stator through the brush access
opening. A .010 gage should be able to pass
completely through the air gap and a .030
gage should not penetrate the air gap any far-
ther than any tapered portion on the end of the
gage.
11. Reinstall the control box and fuel tank previ-
ously removed.
12. Replace the case wraparound cover.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-51 TROUBLESHOOTING AND REPAIR F-51
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
Return to Section TOC
Return to Master TOC
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the rotor.
MATERIALS NEEDED
Rotor Puller Tool (See parts pages for the tool part number)
Impact Wrench
Return to Section TOC
Return to Master TOC
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-52 TROUBLESHOOTING AND REPAIR F-52
ROTOR
Return to Section TOC
Return to Master TOC
THROUGH BOLT
PROCEDURE
IMPORTANT
Return to Section TOC
Return to Master TOC
1. Perform the Stator Removal Procedure. It is highly recommended that a new bearing be
2. Remove the long through-bolt from the bearing installed before the rotor is secured to the
end of the rotor. (An impact wrench works best engine crankshaft.
for removing this through-bolt). See Figure 2. Thoroughly clean the engine crankshaft and the
F.21. rotor shaft where it mates to the engine crank-
3. Remove the rotor from the engine crankshaft shaft. Place the rotor on the crankshaft.
using the Lincoln rotor-pulling tool. See instruc- 3. When installing rotor thru-bolt, apply thread-
tions supplied with the tool. locking compound, (Locktite 2760 or equiva-
lent) torque the rotor thru-bolt to 22 to 24 ft-lbs.
IMPORTANT
4. After the rotor is secured to the engine crank-
Handle and store the rotor very carefully to shaft, check the run-out at the bearing outer
avoid damage to the windings. race. Run out should not exceed .015 F.I.M.
If necessary, the cast end bracket can now be 5. See the stator removal and installation proce-
removed from the engine. dures for further assembly instructions.
Return to Section TOC
Return to Master TOC
OUTBACK 185
F-53 TROUBLESHOOTING AND REPAIR F-53
PROCEDURE
NOTE: Values shown above are for a machine that is at normal full load temperature. Readings will
likely be slightly higher if machine is cold.
Return to Section TOC
Return to Master TOC
OUTBACK 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-54
NOTES
OUTBACK 185
F-54
Return to Master TOC G-1 TABLE OF CONTENTS - DIAGRAM SECTION G-1
* NOTE: Many PC Board Assemblies are now totally encapsulated, surface mounted and or multi-lay-
ered and are therefore considered to be unserviceable. Assembly drawings of these boards are
no longer provided.
Return to Master TOC
Return to Master TOC
Return to Master TOC
OUTBACK 185
G-2 ElEcTrical DiaGramS G-2
WiriNG DiaGram - cOmplETE machiNE cODE 11516 (l13878)
Return to Section TOC
Return to Master TOC
77
GND-J GROUND STUD
76 ON CONTROL PANEL
R1 FRONT
75 7
OIL GND-G
LEVEL
GND-K
MODULE 224A
LOW OIL 9 GND
INDICATOR GND-C
L.E.D. 224 GND-F
Return to Section TOC
Return to Master TOC
BW BW CB1
HOUR METER 30A
3
3 11
BLUE Y Y
GND-K CB2
3A 20A 3B
P4 5 GND-C GND-D J4
BR BR 5 5A SILVER
B 5A J6
1 212
2 GND-I 5B
BLACK 210B 3 210A NEUTRAL STUD
ON CONTROL 6B
208 4 208A PANEL BOTTOM CB3, 20A 240 V
213B 5 6
YR GND-E
215A 6 215 WRAP IN
IDLE SILVER
6A 30A 6B
OPPOSITE CB1 5B J5
BW SOLENOID OFF 213A DIRECTIONS
FUSE S1 12
BLACK 230
IGNITION 209A 213 W3 W3A 3RD
ALT.
OIL COILS AUTO D1 +
STARTER POS EL-B ELEC
LEVEL HIGH 211 WRAP 1 (TOP)
SENSOR SPARK
SOLENOID TURN
CHOKE ELECTRODE
210A L1
(CLOSED WHEN PLUG +
OIL LEVEL
ENGINE
STARTER
12
VOLT 209
W4
AC REACTOR _ +
4TH (TOP)
1 5 1 6 1 2
J3 J1 J2
6 10 7 12 3 4
B1 B2 B3 B4
FIELD / IDLER PC BOARD
Return to Section TOC
Return to Master TOC
L13878PRINT
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
OUTBacK 185
G-3 ElEcTrical DiaGramS G-3
SchEmaTic - cOmplETE machiNE cODE 11516 (G6205)
Return to Section TOC
Return to Master TOC
GROUNDSTUD
7 ONCONTROL PANEL
FRONT
GND-G
82 VAC GND-K
9 GND
GND-C
GND-F
CB1
30A
3
3 11
CB2
3A 20A 3B
5 GND-C GND-D J4
5 5A SILVER
5A J6
5B
NEUTRAL STUD
ONCONTROL
PANEL BOTTOM
6B
CB3, 20A 240 V
6
GND-E
SILVER
CB1 6B 5B J5
WRAP 4 TURNS
INOPPOSITE
6A 30A
DIRECTIONS
12
TOP W3A D1
3RD
W3 AC REACTOR ELEC
62 VAC EL-B +
< 0
ELECTRODE
Return to Section TOC
CHOKE
Return to Master TOC
AC REACTOR both
64 VAC top front
< 90
ROTOR
FIELD W2 2ND
Pos. brush is closest to lamination
+ MAY OPEN IF
MACHINE IS
WORK _
9 ohms SLIP OVERLOADED 13A
30 min to 50 VDC max RINGS CB4 14
- UNDER Boost Coils WORK
Used to supply bd. under front edge
brushes lower front CONTROL
power during of control box ( RIGHT)
under cover BOX
1. 2 volts AC @ 55 HZ heavy weld short
13 ckt conditions.
indicates quick 9 7 200A 219 Hi rpm with a100W bulb
on 115 aux 6v in = 72 v out
connections 260 261
4 places no load = 26mV.
4.7V
77 J3-6
GND-J
76
+ DRIVER
R1 J1-8 CIRCUIT
1.4V - SUPPRESSOR FOR
13 kHz. D1 RECTIFIER J1-12 8
OIL +
LEVEL insulated inline 75 J3-5 .05
connectors - 130V 5K
Return to Section TOC
MODULE
Return to Master TOC
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
OUTBacK 185
G-4 ElEcTrical DiaGramS G-4
SchEmaTic - FiElD cONTrOl / iDlE pc BOarD (G4793-1)
Return to Section TOC
Return to Master TOC
J2 TO IDLE
1 SOLENOID
J1
6
+ DIODES
C1 5.1K
TP1
R1
0.05uF 5W +10V
130V 600V
38J
- DIODES +10V R65
J1 13.7K
12 +10V
SNUBBER R64 D12
R25
24.3K 1A
+10V 33.2K C34 400V
0.047uF
R42
10K 250V
J3 J1 #215
R39
3 22.1K 3
TO IDLE
7 1 SET SOLENOID
R24
R2 133K Q1
J3 1 2 RESET 18A
10 X1 200V
5 6 2901N 3 IN1 X4
22 1 15 MONO_IN DZ4
R23
R26
CR1 CR1 100K 14 OSC_INH OUT1 4 475 15V 1W
12VDC 6 8-BYPASS C9
OUT2 5 11
R17 0.047uF
3 4 C18 C17 9 A DECODE 13 R38 13 X1 250V
26.7K
R43
2
750
0.1uF 0.022uF 10 B 10K 10
50V 50V 4536B 2901N
11 C
R27
100K D14
12 D 1A/FR
J3 CASE +10V 400V
OVERCURRENT
R14
4 7 CLOCK_INH PROTECTION C10
1.3K 0.51
R11
COM 22uF 5W
63V
J3 +10V
7
R40
10K
COM
J3
9 COM
R49
D1 D3 8.25K
Return to Section TOC
14A 14A
Return to Master TOC
200V 9 12
200V
J3 X1 14 X6 14 10
8 8 13 8 +12V
2901N 224N D18 X6
+10V 0.2A C25 9
C2 C3 30V 0.1uF 224N D20
R50
330uF 330uF 3.32K 0.2A R7
100V 100V 50V 30V #224
J1
9 +12 BATTERY
COM From
R41
162K 5 2901N 0.125 RUN SWITCH
R51
CASE 100K
X1 2 TP2
4 50V
D17 15J
0.2A +10V COM
D16 30V
R10 0.2A +10V
162 30V C15 COM
C6
D9
1A 1.8uF CLUSTER 2
20V
2.21K
R6
DZ2 0.1uF 30V
J2 50V +10V
R72
260 3 12V 4.75K
1W
R76
COM 8.25K
3
TOROID 332
R8
X6 1 5 10
DZ1
R4
C5 COM C38 5W
R70
J2 12V 10 2 7
2.21K
0.1uF
R73
261 4 10K 224N D22 X6
R5
1W 0.1uF 1A 50V 0.2A C40
50V 0.1uF 6 224N D23
30V 30V
R74
6.19K 50V 0.2A
R12
R9 332 10 FLASH
30V
R3
162 D8 +10V 5W
COM
R71
1M COM
R75
100K
D4
R13
332 3A/FR
600V
D19 COM
R67
10K 0.2A C29
30V 100uF
5 16V
J3 7 C37
6 R28 R68 X5 COM
475 6 47pF C36 TP-A D13
47.5 100V 0.022uF C4
C19 224N 1A
77 50V 400V
0.1uF 700 700 160V
50V R69
R66
7.5K J1 #200B B2
10K CONTROL POT INPUT
1A
Return to Master TOC
J1 12 10 400V
8 R44 CURRENT AMP
76 14 5 8 1 4
100K C21 C20 X5 R45 X7 D7
0.1uF 0.1uF 13 1K 7 9
C24 50V 50V 224N X7 R55 33074A C7 DZ3
R37
C13 10K 82uF
R29
50V COM 10 5W D5 3
50V +10V 14A B1
22.1K 200V 9
R61
R56 10K 8 Q7
10 100K R58 VREF 195mA
4 B3
75 J3 8 RT/CT VCC 7 60V COM
5 R30 R48 X5 C23 2
9 47pF VFB X3 OUT 6 J1 219 2
47.5 475 C22 C26
224N 100V
0.022uF 0.1uF R62 1 COMP GND 5 Q4
5 -FIELD
50V 50V 10K 3 2843A C27
R35
R47 CS 10K 0.5A 1 D6 4
0.1uF
R46
J3 40V 249 Q3
1 NC 475 2.67K 50V
C32 C33 R36 56A
R63
J3 0.0047uF 100pF 51.1K 15K 200V GBPC3504W
2 NC COM 3
50V 100V R59 195mA
60V Q6 Q5 DZ5 B4
J2 C30 .5A D15
2 COM 40V 0.2A 18V 0.1
NC C31 0.0027uF
R22
30V 1W 5W
3 0.0047uF 50V
1 50V
J1 X5
1 NC COM
2 224N
J1
4 NC OVERCURRENT
J1 PROTECTION
7 NC
COM R57
J1 COM
10 NC 2K
12
TP-B
CLUSTER 1 3 R77 R52 14 X7
R54
200
1 X7 10 D21 475 13
1A/FR 33074A
2
J1 33074A 400V
5E 2 +12V
GND D2 D10 DZ7 18V R78
3A 1W 2K
600V COM R33 R34 C41 C43
1A 3.32K 0.022uF 0.1uF
R53
3.32K 221
CASE 400V +10V 50V 50V
+10V LAST NO. USED
TP-C
GENERAL INFORMATION R- 78 Q- 7 TP- 2
Q2 ELECTRICAL SYMBOLS PER E1537 C- 43 X- 7 B- 4
Return to Section TOC
3A
Return to Master TOC
R32
0.022uF X1 0.022uF X5 0.022uF X4 0.022uF X6 0.022uF X7 8.2V 750 C14 3.01K
50V 2901N 50V 224N 50V 50V 224N 50V 33074A 5W 1 0.1uF FRAME CONNECTION
4536B
Vss 50V EARTH GROUND CONNECTION
C11 X2 8 C12
12 11 8 11 11 220uF 431I 220uF CLUSTER INFORMATION
25V 25V
ASSEMBLY No. CLUSTER No. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OWNED BY LINCOLN GLOBAL, INC. AND MAY NOT BE DUPLICATED, COMMUNICATED
DZ8 6 PROPRIETARY & CONFIDENTIAL: TO OTHER PARTIES, OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF LINCOLN GLOBAL, INC.
R31
8.2V 1K
5W L13696-1 1 SINCE COMPONENTS OR CIRCUITRY ON A
COM PRINTED CIRCUIT BOARD MAY CHANGE DESIGN INFORMATION EQUIPMENT TYPE:
OUTBACK 185 PAGE 01 OF 01
DEVELOPMENT 1 & 2 WITHOUT AFFECTING THE INTERCHANGE- DRAWN BY: APM 9-16-2009 DOCUMENT DOCUMENT
ABILITY OF A COMPLETE BOARD, THIS
DIAGRAM MAY NOT SHOW THE EXACT ENGINEER: APM REFERENCE:
SCHEMATIC,SUBJECT:
FIELD/IDLE CONTROL PCB NUMBER: REVISION:
COM
COMPONENTS OR CIRCUITRY OF CONTROLS
HAVING A COMMON CODE NUMBER. APPROVED: DRS --------- MATERIAL
DISPOSITION:
APPROVAL
DATE: NA
4-24-2009
PROJECT
NUMBER: 5026038 4793-1G0 A G
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
OUTBacK 185