Sunteți pe pagina 1din 1

Praesideo 3.

4 | Installation and User Instructions | 7 | System Hardware Installation en | 291

31.5 Maximum cable length The graph (see figure 31.5) shows the relation between
The maximum length of all optical fibers together (both the number of nodes in the system and maximum
POF and GOF) in the system depends on the number of optical fiber length in the system.
nodes in the system. Each piece of equipment has been
assigned a number of nodes.
Note
table 31.2: Nodes A system may not contain more than 63 nodes.
Type no. Description Nodes
LBB4402/00 Audio Expander 1
LBB4404/00 CobraNet Interface 1
PRS-NSP Network Splitter 1 Note
PRS-FIN(S) Fiber Interface 1 The PRS-FINNA counts as 0 nodes for the
PRS-FINNA Fiber Interface 0/1 system limit of 63 nodes, but as 1 node for the
LBB4421/xx Power Amplifier 1x500 W 1 maximum optical fiber length. Therefore, the
LBB4422/xx Power Amplifier 2x250 W 1 dashed part of the line is only applicable to
LBB4424/xx Power Amplifier 4x125 W 1 systems with PRS-FINNA Fiber Interfaces.
LBB4428/00 Power Amplifier 8x60 W 2
LBB4430/00 Call Station Basic 1
LBB4432/00 Call Station Keypad 0
PRS-CSNKP Numeric Keypad 0
LBB4433/00 Call Station Kit 1
LBB4434/00 Call Station Keypad Kit 0
PRS-CSI Call Station Interface 1
PRS-CRF Call Stacker 1
PRS-16MCI Multi Channel Interface 1
PRS-NCO-B Network Controller 3

2150

2050

1950

1850

1750

1650
Maximum cable length (m)

1550

1450

1350

1250

1150

1050

950

850

750

650

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

Number of nodes
figure 31.5: Maximum optical fiber length vs. number of nodes