Sunteți pe pagina 1din 1

COLUMN LOCATION: 3-E, 3-I, 1-A (FTG-2F)

COLUMN #: C1 REBARS: 18-25MM


Column Transverse Reinforcement
f'c = 24
fy = 414
fyt = 228
L of Column= 5500 mm
L unsupported= 4900 mm
d= 600 mm
b= 300 mm
Dia. Of Long bars= 25 mm
# of Longitudinal bars along d = 7 PCS
# of Longitudinal bars along long b = 4 PCS
hx1= 64.16667 mm
hx2= 193.3333 mm SAY:
Lu/6= 816.6667 mm 820 mm okay!
L @ depth = 600 mm 600 mm okay!
Use Lo= 820 mm
Use Lmid= 3260 mm
Use trans. Bar dia.= 10 mm
REQUIRED TIES:
ALONG "b" ALONG "d"
hc1= 236 mm hc1= 536 mm
Ag1= 180000 mm^2 Ag1= 180000 mm^2
Ach1= 126496 mm^2 Ach1= 126496 mm^2
Ash1= 236.418 mm^2 Ash1= 536.949 mm^2
Ash2= 167.684 mm^2 Ash2= 167.684 mm^2
TIES Area Required= 236.418 mm^2 TIES Area Required= 536.949 mm^2
# of bars = 3.01 pcs # of bars = 6.836647 pcs
provide = 4 LEGS provide minimum = 4 LEGS

TIES SPACING W/O SEISMIC PROVISION:


16Ldb= 400 mm 400 mm okay!
48hdb= 480 mm 480 mm okay!
S min= 300 mm 300 mm okay!
REQUIRED SPACING @ Lo = 300 mm

TIES SPACING CONSIDERING SEISMIC PROVISION: (NSCP 2010, 421.6.4.1)


Spacing @ Lo:
S @ b/4= 75 mm 75 mm okay!
So= 150 mm 150 mm okay!
S min= 150 mm 150 mm okay!
REQUIRED SPACING @ Lo = 75 mm

Spacing @ MIDSPAN:
S @ 6db= 150 mm 150 mm okay!
Smin= 150 mm 150 mm okay!
Required Spacing @ Lmid = 150 mm

RECOMMENDATION FOR TRANSVERSE BARS:


USE: 10 MM
Minimum No. TIE Legs along "d": 4 legs

Minimum No. TIE Legs along "b": 4 legs


TIES SPACING: 1 @ 50 mm, 11 @75mm, REST @ 150mm