CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

Table of Contents
LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS...................................................................................2
INPUT LISTING............................................................................................................................................................ 3
2
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

LISTING OF STATIC LOAD CASES FOR THIS ANALYSIS

1 (SUS) W+P1
2 (SUS) W+P2
3 (OPE) W+D1+T1+P1
4 (OPE) W+D2+T2+P2
5 (OPE) W+D2+T2+P2+U1
6 (OPE) W+D2+T2+P2-U1
7 (OPE) W+D2+T2+P2+U2
8 (OPE) W+D2+T2+P2-U2
9 (OCC) L9=L5-L4
10 (OCC) L10=L6-L4
11 (OCC) L11=L7-L4
12 (OCC) L12=L8-L4
13 (OCC) L13=L9+L2
14 (OCC) L14=L10+L2
15 (OCC) L15=L11+L2
16 (OCC) L16=L12+L2
17 (EXP) L17=L3-L1
18 (EXP) L18=L4-L2
3
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
Job Description:

PROJECT:

CLIENT :

ANALYST:

NOTES :

PIPE DATA
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
From 1175 To 1180 DZ= 370.000 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
Dia= 2,032.000 mm Wall= 12.000 mm
GENERAL
T1= 50 C T2= 29 C P1= .6000 MPa P2= .3250 MPa Mat= (601)A134 A283C
E= 203,401 N/sq.mm EH1= 201,012 N/sq.mm EH2= 202,392 N/sq.mm
EH3= 203,401 N/sq.mm EH4= 203,401 N/sq.mm EH5= 203,401 N/sq.mm
EH6= 203,401 N/sq.mm EH7= 203,401 N/sq.mm EH8= 203,401 N/sq.mm
EH9= 203,401 N/sq.mm v = .300 Pipe Den=7850.0000000 kg/cu.m.
Fluid Den=1000.0000000 kg/cu.m. Insul Thk= .000 mm
RESTRAINTS
Node 1175 ANC
UNIFORM LOAD
Vector1 in G-s X1 Dir = .28 g Y1 Dir = .00 g Z1 Dir = .00 g
Vector2 in G-s X2 Dir = .00 g Y2 Dir = .28 g Z2 Dir = .00 g
Vector3 in G-s X3 Dir = .00 g Y3 Dir = .00 g Z3 Dir = .00 g
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1180 To 1185 DZ= 79.900 mm
RIGID Weight=14,696.61 N
RESTRAINTS
Node 1185 ANC Cnode 1186
-----------------------------------------------------------------------------
From 1186 To 1190 DZ= .100 mm
RIGID Weight= 18.39 N
-----------------------------------------------------------------------------
From 1190 To 1194 DZ= 500.000 mm
EXPANSION JOINT
Axial K= 2,067 N/mm Trans K= 2,294 N/mm Tors K= 1,000,000,000 Nmm/rad
Eff Dia=2,400.000 mm
-----------------------------------------------------------------------------
From 1194 To 1193 DZ= -500.000 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
GENERAL
T1= 13 C T2= 13 C P1= .0000 MPa P2= .0000 MPa
RIGID Weight= .00 N
RESTRAINTS
Node 1193 Z Cnode 1190
Node 1193 RX Cnode 1190
4
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
Node 1193 RY Cnode 1190
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1194 To 1195 DZ= .100 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
GENERAL
T1= 50 C T2= 29 C P1= .6000 MPa P2= .3250 MPa
RIGID Weight= 26.37 N
RESTRAINTS
Node 1195 ANC Cnode 1196
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1196 To 1201 DZ= 79.900 mm
RIGID Weight=21,073.63 N
-----------------------------------------------------------------------------
From 1201 To 1200 DZ= 3,020.024 mm
BEND at "TO" end
Radius= 2,940.000 mm (user) Bend Angle= 90.000 Angle/Node @1= 45.00 1199
Angle/Node @2= .00 1198 Miters= 4
-----------------------------------------------------------------------------
From 1200 To 1206 DX= -4,178.990 mm
-----------------------------------------------------------------------------
From 1206 To 1202 DX= -69.989 mm
-----------------------------------------------------------------------------
From 1202 To 1203 DX= -501.000 mm
-----------------------------------------------------------------------------
From 1203 To 1204 DX= -69.989 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
GENERAL
T1= 50 C T2= 29 C P1= .6000 MPa P2= .3250 MPa
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1204 To 1205 DX= -1,230.239 mm
RESTRAINTS
Node 1205 Z Mu = .10
Node 1205 Y Mu = .30
-----------------------------------------------------------------------------
From 1205 To 1210 DX= -2,850.000 mm
-----------------------------------------------------------------------------
From 1210 To 1215 DX= -500.000 mm
RIGID Weight=40,750.00 N
RESTRAINTS
Node 1215 Z Mu = .10
-----------------------------------------------------------------------------
From 1215 To 1220 DX= -500.000 mm
RIGID Weight=40,750.00 N
-----------------------------------------------------------------------------
From 1220 To 1230 DX= -1,450.000 mm
RESTRAINTS
Node 1230 ANC
-----------------------------------------------------------------------------
From 1230 To 1240 DX= -450.000 mm
5
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
-----------------------------------------------------------------------------
From 1240 To 1260 DX= -730.000 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1260 To 1265 DX= -870.000 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
Dia= 1,948.000 mm Wall= 12.000 mm
Insul Thk= .000 mm
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1265 To 1266 DX= -100.000 mm
Dia= 1,828.800 mm Wall= 12.000 mm
Insul Thk= .000 mm
RIGID Weight=14,200.00 N
-----------------------------------------------------------------------------
From 1266 To 1267 DX= -468.000 mm
EXPANSION JOINT
Axial K= 1,772 N/mm Trans K= 1,956 N/mm
Tors K= 9,999,999,800,000 Nmm/rad Eff Dia=2,096.000 mm
-----------------------------------------------------------------------------
From 1266 To 1268 DX= -468.000 mm DY= .000 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
GENERAL
T1= 13 C T2= 13 C P1= .0000 MPa P2= .0000 MPa
RIGID Weight= .00 N
RESTRAINTS
Node 1268 X Cnode 1267 Gap= 2.000 mm
Node 1268 RY Cnode 1267
Node 1268 RZ Cnode 1267
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1267 To 1270 DX= -50.000 mm
B31.1 (2010) Sc= 87 N/sq.mm Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
GENERAL
T1= 50 C T2= 29 C P1= .6000 MPa P2= .3250 MPa
RIGID Weight= 5,200.00 N
DISPLACEMENTS
Node 1270 DX1= .700 mm DY1= .000 mm DZ1= .800 mm RX1= .000
RY1= .000 RZ1= .000 DX2= .300 mm DY2= .000 mm DZ2= .400 mm
RX2= .000 RY2= .000 RZ2= .000
ALLOWABLE STRESSES
-----------------------------------------------------------------------------
From 1260 To 1280 DY= -1,531.938 mm
Dia= 813.000 mm Wall= 10.000 mm
Insul Thk= .000 mm
SIF's & TEE's
Node 1260 Unreinforced Tee Meets D1, Notes 10a,c,d,e,f =ON
6
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
-----------------------------------------------------------------------------
From 1280 To 1290 DY= -53.975 mm
RIGID Weight= 3,000.00 N

MATERIAL Changes:
1175 1180 Mat= (601)A134 A283C E= 203,401 N/sq.mm
v = .300 Density= 7,850.0000 kg/cu.m.
JOBNAME: F:\DATA_SUMIT\PROJECTS\TERNA\PUMP DISCHARGE\PUMP DISCHARGE\15-09-2016-

ALLOWABLE STRESS Changes


1175 1180 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1194 1193 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1194 1195 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1203 1204 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1240 1260 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1260 1265 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1266 1268 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm
1267 1270 B31.1 (2010) Sc= 87 N/sq.mm
Sh1= 87 N/sq.mm Sh2= 87 N/sq.mm
7
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
Sh3= 87 N/sq.mm Sh4= 87 N/sq.mm
Sh5= 87 N/sq.mm Sh6= 87 N/sq.mm
Sh7= 87 N/sq.mm Sh8= 87 N/sq.mm
Sh9= 87 N/sq.mm Sy= 207 N/sq.mm

BEND ELEMENTS
1201 1200 Radius= 2,940.000 mm (user)
Bend Angle= 90.000 Angle/Node @1= 45.00
1199 Angle/Node @2= .00 1198 Miters= 4

RIGIDS
1180 1185 RIGID Weight=14,696.61 N
1186 1190 RIGID Weight= 18.39 N
1194 1193 RIGID Weight= .00 N
1194 1195 RIGID Weight= 26.37 N
1196 1201 RIGID Weight=21,073.63 N
1210 1215 RIGID Weight=40,750.00 N
1215 1220 RIGID Weight=40,750.00 N
1265 1266 RIGID Weight=14,200.00 N
1266 1268 RIGID Weight= .00 N
1267 1270 RIGID Weight= 5,200.00 N
1280 1290 RIGID Weight= 3,000.00 N

SIF's & TEE's


1260 1280 Node 1260 Unreinforced Tee
Meets D1, Notes 10a,c,d,e,f =ON

Expansion Joint Stiffness and Effective Diameter Data


1190 1194 Axial K= 2,067 N/mm Trans K= 2,294 N/mm
Tors K= 1,000,000,000 Nmm/rad
Eff Dia=2,400.000 mm
1266 1267 Axial K= 1,772 N/mm Trans K= 1,956 N/mm
Tors K= 9,999,999,800,000 Nmm/rad
Eff Dia=2,096.000 mm

REDUCERS
1240 1260 Diam2= 1,948.000 mm Wall2= 12.000 mm
1260 1265 Diam2= 1,828.800 mm Wall2= 12.000 mm

RESTRAINTS Len MU
GAP YIELD Dir
NODE TYPE CNODE STIF1 STIF2 FORCE Vectors
-------+-------+------+----------+----------+----------+---------------------
1175 ANC .000 .000 .000
1185 ANC 1186 .000 .000 .000
1193 Z 1190 .000 .000 1.000
8
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
1193 RX 1190 1.000 .000 .000
1193 RY 1190 .000 -1.000 .000
1195 ANC 1196 .000 .000 .000
1205 Z .10 .000 .000 1.000
1205 Y .30 .000 -1.000 .000
1215 Z .10 .000 .000 1.000
1230 ANC .000 .000 .000
1268 X 1267 2.00 1.000 .000 .000
1268 RY 1267 .000 -1.000 .000
1268 RZ 1267 .000 .000 1.000

DISPLACEMENTS
1267 1270 Node 1270 DX1= .700 mm DY1= .000 mm
DZ1= .800 mm RX1= .000 RY1= .000 RZ1= .000
DX2= .300 mm DY2= .000 mm DZ2= .400 mm
RX2= .000 RY2= .000 RZ2= .000

UNIFORM LOAD Changes


1175 1180 Vector1 in G-s
X1 Dir = .28 g Y1 Dir = .00 g
Z1 Dir = .00 g
Vector2 in G-s
X2 Dir = .00 g Y2 Dir = .28 g
Z2 Dir = .00 g
Vector3 in G-s
X3 Dir = .00 g Y3 Dir = .00 g
Z3 Dir = .00 g

INPUT UNITS USED...

UNITS= LII NOM/SCH INPUT= OFF


LENGTH inches x 25.400 = mm
FORCE pounds x 4.448 = N
MASS(dynamics) pounds x 0.454 = kg
MOMENTS(INPUT) inch-pounds x 0.113 = Nm
MOMENTS(OUTPUT) inch-pounds x 0.113 = Nm
STRESS lbs./sq.in. x 0.007 = N/sq.mm
TEMP. SCALE degrees F. x 0.556 = C
PRESSURE psig x 0.007 = MPa
ELASTIC MODULUS lbs./sq.in. x 0.007 = N/sq.mm
PIPE DENSITY lbs./cu.in. x 27680.000 = kg/cu.m.
INSULATION DENS. lbs./cu.in. x 27680.000 = kg/cu.m.
FLUID DENSITY lbs./cu.in. x 27680.000 = kg/cu.m.
TRANSL. STIF lbs./in. x 0.175 = N/mm
ROTATIONAL STIF in.lb./deg. x 6473.600 = Nmm/rad
UNIFORM LOAD lb./in. x 0.175 = N/mm
G LOAD g's x 1.000 = g
WIND LOAD lbs./sq.in. x 0.007 = N/sq.mm
ELEVATION inches x 25.400 = mm
COMPOUND LENGTH inches x 25.400 = mm
DIAMETER inches x 25.400 = mm
WALL THICKNESS inches x 25.400 = mm
9
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING

SETUP FILE PARAMETERS


------------------------------------------------------------------------------
CONNECT GEOMETRY THRU CNODES = YES
MIN ALLOWED BEND ANGLE = 5.00000
MAX ALLOWED BEND ANGLE = 95.0000
BEND LENGTH ATTACHMENT PERCENT = 1.00000
MIN ANGLE TO ADJACENT BEND PT = 5.00000
LOOP CLOSURE TOLERANCE = 25.4000 mm
THERMAL BOWING HORZ TOLERANCE = 0.100000E-03
AUTO NODE NUMBER INCREMENT= 10.0000
Z AXIS UP= YES
USE PRESSURE STIFFENING = DEFAULT
ALPHA TOLERANCE = 0.500000E-01
RESLD-FORCE = NO
HGR DEF RESWGT STIF = 0.175120E+12 N/mm
DECOMP SNG TOL = 0.100000E+11
BEND AXIAL SHAPE = YES
FRICT STIF = 175120. N/mm
FRICT NORM FORCE VAR = 0.150000
FRICT ANGLE VAR = 15.0000
FRICT SLIDE MULT = 1.00000
ROD TOLERANCE = 1.00000
ROD INC = 2.00000
INCORE NUMERICAL CHECK = NO
OUTCORE NUMERICAL CHECK = NO
DEFAULT TRANS RESTRAINT STIFF= 0.175120E+12 N/mm
DEFAULT ROT RESTRAINT STIFF= 0.647360E+16 Nmm/rad
IGNORE SPRING HANGER STIFFNESS = NO
MISSING MASS ZPA = EXTRACTED
MIN WALL MILL TOLERANCE = 12.5000
WRC-107 VERSION = MAR 79 1B1/2B1
WRC-107 INTERPOLATION = LAST VALUE
DEFAULT AMBIENT TEMPERATURE= 12.6024 C
BOURDON PRESSURE= NONE
COEFFICIENT OF FRICTION (MU) = 0.300000
INCLUDE SPRG STIF IN HGR OPE = NO
INCLUDE INSULATION IN HYDROTEST = NO
REDUCED INTERSECTION = B31.1(POST1980)
USE WRC329 NO
NO REDUCED SIF FOR RFT AND WLT NO
B31.1 REDUCED Z FIX = YES
CLASS 1 BRANCH FLEX NO
ALL STRESS CASES CORRODED = NO
ADD TORSION IN SL STRESS = DEFAULT
ADD F/A IN STRESS = DEFAULT
OCCASIONAL LOAD FACTOR = 1.20000
DEFAULT CODE = ISO-14692
B31.3 SUS CASE SIF FACTOR = 1.00000
ALLOW USERS BEND SIF = NO
USE SCHNEIDER NO
YIELD CRITERION STRESS = MAX 3D SHEAR
USE PD/4T NO
BASE HOOP STRESS ON ? = ID
EN13480 USE IN OUTPLANE SIFS= NO
LIBERAL EXPANSION ALLOWABLE= YES
10
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
B31.3 SEC 319.2.3C SAXIAL= NO
B31.3 WELDING/CONTOUR TEE ISB16.9 FALSE
PRESSURE VARIATION IN EXP CASE= DEFAULT
IMPLEMENT B313 APP-P NO
IMPLEMENT B313 CODE CASE 178 YES
IGNORE B31.1/B31.3 Wc FACTOR= NO
USE FRP SIF = YES
USE FRP FLEX = YES
BS 7159 Pressure Stiffening= Design Strain
FRP Property Data File= CAESAR.FRP
FRP Emod (axial) = 11791.1 N/sq.mm
FRP Ratio Gmod/Emod (axial) = 0.370000
FRP Ea/Eh*Vh/a = 0.172100
FRP Laminate Type = THREE
FRP Alpha = 24.9982 C
FRP Density = 1860.10 kg/cu.m.
EXCLUDE f2 FROM UKOOA BENDING = NO

EXECUTION CONTROL PARAMETERS

Rigid/ExpJt Print Flag ..... 1.000


Bourdon Option ............. .000
Loop Closure Flag .......... 2.000
Thermal Bowing Delta Temp .. .000 C
Liberal Allowable Flag ..... .000
Uniform Load Option ........ 1.000

Ambient Temperature ........ 12.600 C


Plastic (FRP) Alpha ........ 21.598
Plastic (FRP) GMOD/EMODa ... .250
Plastic (FRP) Laminate Type. 3.000
Eqn Optimizer .............. .000
Node Selection ............. .000
Eqn Ordering ............... .000
Collins .................... .000
Degree Determination ....... .000
User Eqn Control ........... .000

COORDINATE REPORT
/--------------------(mm )----------------------/
NODE X Y Z
1175 969335.250 1257487.750 -405.437
1180 969335.250 1257487.750 -35.437
1185 969335.250 1257487.750 44.463
1193 969335.250 1257487.750 44.563
1194 969335.250 1257487.750 544.563
1193 969335.250 1257487.750 44.563
1194 969335.250 1257487.750 544.563
1195 969335.250 1257487.750 544.663
1201 969335.250 1257487.750 624.563
1200 969335.250 1257487.750 3644.587
1206 965156.250 1257487.750 3644.587
1202 965086.250 1257487.750 3644.587
1203 964585.250 1257487.750 3644.587
11
CAESAR II 2013 R1 Ver.6.10.00.0028, (Build 121130) Date: DEC 2, 2016 Time: 15:45
Job:: PUMP DISCHARGE
Licensed To:: LAHMEYER INTERNATIONAL (INDIA) PVT LTD.

INPUT LISTING
1204 964515.250 1257487.750 3644.587
1205 963285.000 1257487.750 3644.587
1210 960435.000 1257487.750 3644.587
1215 959935.000 1257487.750 3644.587
1220 959435.000 1257487.750 3644.587
1230 957985.000 1257487.750 3644.587
1240 957535.000 1257487.750 3644.587
1260 956805.000 1257487.750 3644.587
1265 955935.000 1257487.750 3644.587
1266 955835.000 1257487.750 3644.587
1268 955367.000 1257487.750 3644.587
1266 955835.000 1257487.750 3644.587
1268 955367.000 1257487.750 3644.587
1270 955317.000 1257487.750 3644.587
1260 956805.000 1257487.750 3644.587
1280 956805.000 1255955.750 3644.587
1290 956805.000 1255901.750 3644.587