Documente Academic
Documente Profesional
Documente Cultură
MAINTENANCE COURSE - T1 & T2 (RR / Metric) TABLE OF CONTENTS Apr 21, 2006
LEVEL III - ATA 24 Electrical Power Page 1
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 2
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 3
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 4
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
TABLE OF PRIORITY
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 5
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 6
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 7
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 8
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 9
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 10
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 11
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 12
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 13
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 14
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 15
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 16
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 17
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 18
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
AC ABNORMAL CONFIGURATION
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 19
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 20
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 21
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 22
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 23
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 24
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
DC ABNORMAL CONFIGURATION
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 25
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 26
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 27
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 28
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 29
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 30
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 31
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 32
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D1000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) NETWORK ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 33
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 34
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D2000000001
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 35
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 36
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D2000000001
PEDMU CARD
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 37
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 38
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D2000000001
RCCBM CARD
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 39
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 40
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D2000000001
PCDM CARD
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 41
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 42
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D2000000001
SRPS CARD
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC ARCHITECTURE DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 43
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 44
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 45
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 46
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 47
A380 TECHNICAL TRAINING MANUAL
an alternating voltage to the generator excitation function. The - Over / Under-voltage protection
generator excitation function regulates this alternating voltage and - Over-frequency protection (Opening / closure of the GLC)
sends an exciter field to the Main Exciter (ME). The ME transformed - Differential Protection (feeder fault between generator and GLC)
this exciter field in rectified AC voltage thanks to rotating diodes. The - Overload (without under-voltage condition)
Main Alternator (MA) induces a main field excitation and produces - Open circuit
the 115 VAC for the network. - Engine Fire Trip Request function (FIRE P/B SW)
The Point Of Regulation (POR) in the PEPDC is used to measure and - PMG Failure detection
monitor the delivered voltage. - Rotating diode failure detection
- GLC failure protection
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 48
A380 TECHNICAL TRAINING MANUAL
BITE Function
The GGPCU fulfills the electrical power generation BITE function
as follows:
- Detection of any failure affecting the VFG channel,
- Identification of the Line Replaceable Unit (LRU) responsible for
the failure,
- Memorises the information of the failure in a Non Volatile Memory
(NVM)
- Communication with CMS to transmit failure information, and
receive status information such as interactive mode functions including
system test, safety test and request for software identification data)
The GGPCU also transmits generating channel parameters and status
to the ECAM system.
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 49
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 50
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 51
A380 TECHNICAL TRAINING MANUAL
value
- The electrical parameters of the AC power delivered are out of limits
- Generator fault detection appears.
Notice that in case of loss of one PCDM, the control and management
of its contactors will be done by the other PCDM on the same side.
The ENMF has an AC load shedding function, which acts on the
galley line contactors in case of an overload. For monitoring purposes,
the PCDMs of one side sends network configuration and monitoring
data to the PEDMUs on the same side.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 52
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 53
A380 TECHNICAL TRAINING MANUAL
removes the ground of the SIC coil and two discrete signals inform
the PCDMs (1 signal per side) to open all BTCs. The white OFF
legend appears on the BUS TIE P/B SW.
Notice that the reconfiguration of the AC network is done in less than
100ms.
For monitoring purposes, the PCDMs of one side send network
configuration and monitoring data to the PEDMUs on the same side.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 54
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 55
A380 TECHNICAL TRAINING MANUAL
Note that there is no airflow control in the heat exchanger. The oil cooler
includes a Pressure Relief Valve letting bypass the cooler matrix in cold
start condition (high viscosity).
A low-pressure warning switch is triggered if the oil pressure is lower
than 35 psi. In this case, the VFG becomes faulty after 30s and it is
automatically disconnected after 5 min.
A pressure relief valve installed just before the generator regulates oil
flow to the rotor in order to avoid an over pressure of the oil circuit. The
excess oil returns directly to the sump through this pressure relief valve.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 56
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 57
A380 TECHNICAL TRAINING MANUAL
(2)(3)(4) OIL LVL LO": oil level servicing required for the next
DRIVE P/B SW comes on.
dispatch.
Those ECAM messages are inhibited during taxi and flight. Oil Filter
Oil Pressure In case of clogged filter condition, the VFG sends a differential
pressure signal to the control and Protection functions of the GGPCU.
A pressure switch monitors the VFG oil pressure. In case the oil
The GGPCU sends maintenance data to the CMS through the
pressure is behind a defined threshold (less than 35psi), the VFG sends
CPIOM-E and the AFDX network.
a fault warning to the control and protection function of its relative
The CMS sends information for the clogged filter. In addition, the
GGPCU. The ECAM displays the following caution; ELEC DRIVE
ECAM will start a counter and if the filter is not replaced within 500
1 (2)(3)(4) OIL PRESS LO. In addition, the FAULT light on the
hours, an "OIL SYSTEM FAULT" message is shown.
DRIVE pushbutton switch is lighted on. So the cockpit crew must
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 58
A380 TECHNICAL TRAINING MANUAL
The clogged filter can be visually checked by the DPI pop-up on the
VFG.
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 59
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D3000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 60
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) VARIABLE FREQUENCY GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 61
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 62
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D4000000001
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 63
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 64
A380 TECHNICAL TRAINING MANUAL
GGPCU Power Supply
The internal supply board of the GGPCU works with a 28 VDC power.
There are two electrical sources available to power the GGPCU; the
DC ESS BUS or the APU GEN. In the first case, the DC ESS BUS
supplies directly the GGPCU supply board with 28 VDC when the
VFG is not driven (no power produced by the VFG). When the VFG
is running, the PMG supplies AC power to the GGPCU supply board
through a TR installed inside the GGPCU.
L1W06161 - L0KT0T0 - LM24D4000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 65
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D4000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 66
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 67
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 68
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D4000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) APU GENERATOR DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 69
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EXTERNAL POWER DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 70
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D5000000001
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EXTERNAL POWER DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 71
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EXTERNAL POWER DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 72
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D5000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EXTERNAL POWER DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 73
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EXTERNAL POWER DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 74
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D5000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EXTERNAL POWER DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 75
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 76
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D6000000001
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 77
A380 TECHNICAL TRAINING MANUAL
The BCRU is internally supplied from two independent 28VDC power If an over-current failure occurs, the signal is sent before the contactors
sources. The first one is given by an internal device (power supply opening.
module), which is supplied from the normal AC network. The second
Configuration Management Function
one called "back-up" is supplied by the relative HOT BUS. This last
source is used on bat configuration like for the refuel. The BCRU has a configuration management function able to connect
and disconnect the BCRU and the battery to the their relative DC
Protection Functions BUS.
The BCRU fulfills some protection functions in order to protect the When AC power is available at the BCRU input, this one closes the
BCRU, the batteries and the DC electrical network. These protections related BLC and BAT LC (if battery is available). Then, the BCRU
have supplies its relative DC BUS and the battery fulfills the NBPT
- Protection against a short circuit, function.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 78
A380 TECHNICAL TRAINING MANUAL
Three seconds after a loss of AC power at the BCRU input, the BCRU coming from the BCRU to the On-board Maintenance System (OMS)
opens the related BLC and maintains the battery connected via the through the Secure Communication Interface (SCI).
BAT LC for two additional seconds.
Interface Module
Battery Charge Management Function The BCRU receives and sends analogue, discrete and digital signals
The BCRU optimizes the battery charging law to have enough energy to and from the other aircraft systems. The interface module enables
before the take-off to fulfill emergency operations. The Battery current the BCRU to communicate with other systems such as batteries,
measurement sends to the BCRU the battery charging or discharging network contactors, IOM-As, CPIOMs-E.
information. This current information is used to achieve the protective Thanks to the interface module, the BCRU sends contactors command,
functions, to optimize the charge of the battery and to fulfill the monitoring of the BCRU and monitoring of the DC network. The
security level. BCRU sends operational signals and failures to the IOM-As. Failure
The Battery is already connected to its related DC BUS for NBPT. If messages are shown to the crew on the Flight Warning System (FWS)
the battery is discharged, the BCRU regulates its output DC power in and Control and Display System (CDS).
order to increase the power delivered to the DC BUS. Consequently,
the DC BUS, which accepts a highest DC power, supplies the battery BCRU 1
to charge it.
The BCRU 1, normally powered by the AC BUS 2, supplies the DC BUS
Reset Function 1 through the BLC 1. In parallel, the BAT 1 is connected to the DC BUS
The BCRU has a remote reset C/B placed on the reset overhead panel. 1 through the BAT LC 1 in order to fulfill the NBPT function. The BCRU
The BCRU can be reset via a maintenance test request through the 1 is in charge of the control and management of the BLC 1 and BAT LC
Central Maintenance System (CMS). 1 contactor coils by means of discrete signal. It also manages the BAT
1 charge.
BITE Function When no AC power is available and the BAT 1 P/BSW is set to the ON
BCRU has a BITE function, which fulfills: position, the BCRU1 BACK-UP RELAY connects the HOT BUS 1 to
- Failure Validation and Localization the BCRU 1 for internal supply.
L1W06161 - L0KT0T0 - LM24D6000000001
- Storage of the data The BCRU 1 can be reset via the TR 1 C/B placed on the overhead
- Communication with the aircraft RESET PANEL (1231VM).
The BITE is done automatically during power up (Power on self test
(POST)) and continuously during operation (C-BIT).
The POST checks all the BCRU and TR Line Contactors and all the
BAT LC. The POST also checks the BCRU protection functions.
The BCRUs are connected to the Electrical System BITE Function
(ESBF) in the CPIOM-E 1 and 2 through ARINC bus 429. The aim
of the ESBF is to gather, correlate and transmit BITE information
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 79
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D6000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 80
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 81
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 82
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D6000000001
BCRU 2
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 83
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 85
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D6000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 86
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) DC MAIN GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 87
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 88
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D7000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 89
A380 TECHNICAL TRAINING MANUAL
Then, the actuator opens RAT fairings doors and deploys the RAT the Display Unit (DU).
by means of spring forces.
Manual Deployment
The cockpit crew can deploy the RAT manually via the RAT MAN
ON P/B SW. This action must be done in case the automatic
deployment fails or, during a manual test procedure. When the RAT
MAN ON P/B SW is pressed, a discrete signal is sent to the
Emergency Power Centre, which supplies 28 VDC (DC ESS BUS)
to Solenoid 1. Then the deployment process is identical to the
automatic deployment
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 90
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D7000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 91
A380 TECHNICAL TRAINING MANUAL
When all parameters are correct at the POR, the GCU sends a Power 28 VDC supply for this BITE function comes from the SEPDC 1.
Ready Signal to the Emergency Power Centre. Therefore, the
Emergency Power Centre opens the AC ESS FEED contactors and Cockpit Communication
the GCU closes the EGLC. For cockpit communication purpose, the GCU sends status and
The GCU is designed with protective functions, which are: parameters of the RAT GEN to the cockpit through the ADCN via
- An OVERVOLTAGE protection IOM-As.
- An UNDERVOLTAGE protection
GCU Supply
- DIFFERENTIAL CURRENT protection
- OVERCURRENT protection When the turbine rotates, the generator starts to provide AC power.
- PARALLEL OPEN FEEDER protection The Pilot Exciter supplies the GCU (except for the BITE function)
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 92
A380 TECHNICAL TRAINING MANUAL
by converting internally the AC power to a DC power. The SEPDC
1 supplies 28 VDC power for the BITE function
L1W06161 - L0KT0T0 - LM24D7000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 93
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D7000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 94
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 95
A380 TECHNICAL TRAINING MANUAL
- Fan failure
- Output overvoltage,
- Output undervoltage
- Overheat
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 96
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D7000000001
STATIC INVERTER
MAINTENANCE COURSE - T1 & T2 (RR / Metric) EMERGENCY GENERATION SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 97
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 98
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D8000000001
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 99
A380 TECHNICAL TRAINING MANUAL
Each PEDMU receives discrete signals in order to get pushbuttons is received from the PCDM.
and network status. Moreover, the PDMI receives through a can bus The second level of shedding given by the PEDMU is linked to an
RCCB trip reset order, secure open orders, and RCCB secure open overload situation. In this case, according to its shedding table taking
reset. into account the primary network configuration, the PEDMU sends
Note that each PEDMU of one side communicates with all the opening orders to RCCBMs following a predetermined order. In that
RCCBMs of the same side. case, some loads are momentarily disconnected in order to restore a
The PEDMUs receive from PCDM closing and opening orders for power supply margin.
Battery Charge and Rectifier Unit (BCRU) 2 and Transformer Rectifier Note that this shedding acts before the overload situation leads the
Unit (TRU) 2 RCCBs. These orders will then be transmitted to the GGPCU to open Bus Tie Contactors (BTCs), Generator Line
RCCBM. Contactors (GLCs) and External Power Contactors (EPCs).
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 100
A380 TECHNICAL TRAINING MANUAL
When no Shedding table is downloaded in the PEDMU, this one shall Downloading
not send shedding orders to the RCCBMs. The SCI interface lets download and save in the PEDMU the shedding
Two pushbuttons control the power supply of galleys and commercial table related to its shedding function and the aircraft configuration
items. They are directly connected via a discrete signal to the PEDMU. table (loads presence and current rating). The PEDMU includes the
When released out, the OFF legend on the pushbutton comes on. capability to download the aircraft configuration table, received from
The GALLEY pushbutton is used to cut off all galleys electrical the SCI and to transfer it to the RCCBMs. The PEDMU will include
equipment of the A/C. a shop loading capability for its applicative software used for example,
The COMMERCIAL pushbutton is used to cut off all commercial to download the software when the PEDMU is installed in the PEPDC.
equipment in the cabin (Such as In Flight Entertainment, Electric seats When a PEDMU is downloading a RCCBM or a PCDM, the adjacent
...) including the Galleys. PEDMU shall fulfill the PEDMU functions.
As an example, Commercial P/B can be selected OFF for a ferry flight
without passengers; then the galleys will not operate as well. CDS and FWS data function
Messages are sent to the ECAM to indicate the loss of power to the The PEDMU transmits CDS and FWS data to IOMs through ARINC
crewmembers. 429 links.
Information is also shown on the FAP page "Power management"
accessed through "System info". This page displays the list of cabin Maintenance function by PDMI
items de-energized. The PDMI interface, which works through the PEDMUs, lets whatever
Note that the aircraft is designed to fly without overload with three the electrical A/C configuration is:
VFGs operating. - Check the C/B status (closed/open),
- Check the RCCB status (tripped/not tripped, closed/open, secure
Monitoring open activated/not activated)
The PEDMUdoes the monitoring of all units and components of the - Check RCCB current measurements,
PEPDC. To do it, the PEDMU receives monitoring information from - Send secure open orders/resets to RCCBM.
PCDM and RCCBM. It also reads the status of AC and DC circuit When aircraft is not energized, PEDMU shall be supplied by the PDMI
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 101
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 102
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 103
A380 TECHNICAL TRAINING MANUAL
such as: the line contactors, the transfer contactors and the transfer
The GALLEY PBSW signal is received by the PCDM to open all
busbars contactors.
galley contactors (Galley Line Contactor (GALC) 1, 2, 3 and 4). This
The ENMF receives the state of power sources from the power sources
shedding has priority on ENMF control and is activated as long as the
control units (Generator and Ground Power Control Units (GGPCUs),
pushbutton is active. When the GALLEY PBSW becomes inactivated,
BCRUs) and the current AC and DC network configuration by the
the galley contactors, which had been opened, are then reconnected
PCDM analysis. Each contactor position is defined by the ENMF
except if others shedding functions asked shedding.
taking into account:
- The power sources information, Ground Servicing Management
- The priority laws defining the AC and DC main busbar power supply When GrouND SELECT ConTroL PBSW is activated, the PCDM
source, sends a Ground signal to the RCCBMs, which manage ground service
- The current network status. RCCBs.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 104
A380 TECHNICAL TRAINING MANUAL
If a "Power ready" from a GGPCU is activated during ground service disables its contactor controls in order to let normal ENMF work by
mode, PCDM aborts the ground service mode in order to give priority the adjacent PCDM.
to normal mode. During normal mode (power from Variable Frequency
Generator (VFG), APU or EXT PWR (External Power)), an activated
Ground Servicing signal is not taken into account by PCDM in order
to give priority to normal mode.
Monitoring
The PCDM monitors the status of each AC and DC contactor located
on the same and opposite sides. Then it provides the monitoring data
to the monitoring function included in the PEDMU through its CAN
bus. In case of reconfiguration, the PCDM sends the new configuration
when the network is stabilized
The PCDM sends to the PEDMU the following data:
- PCDM status (BITE results),
- Contactor status,
- Voltage presence and value of each main busbar,
- Configuration of the network
The PEDMU then sends to the CPIOM from its monitoring function
the following data:
- The AC and DC primary distribution network status,
- The AC main busbars voltage presence and value,
- The RCCBs AC current measurements.
BITE
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 105
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 106
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 107
A380 TECHNICAL TRAINING MANUAL
the RCCBM closes simultaneously the ATA RCCBs. The ATA The RCCBM also monitors the AC and DC RCCB drivers, which
systems orders have the priority over the PEDMU orders to close any have:
RCCB. - The monitoring of the control applied at the input of contactor driver,
After sending a RCCB opening or closing order, the RCCBM inhibits - The monitoring of the status of the RCCB driver controlled which
during 100ms the reading of the current flowing through the RCCB. is transmitted to the PEDMU
The secure open order put in place via the PDMI prevents from closing
the related RCCB. The secure open orders have full authority over Ground Servicing Management
the commutation orders received from the PEDMU. The RCCBM When GND SELECT CTL PBSW is activated, the PCDM sends a
acknowledges the secure open orders to the PEDMU. The Secure Ground Servicing signal to the RCCBMs. Then, the RCCBMs close
open orders are saved in the RCCBM Secure open memory. all Ground Service (GS) RCCBs
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 108
A380 TECHNICAL TRAINING MANUAL
In ground servicing configuration, no dialog with PEDMU shall be
possible (PEDMU not supplied). When Ground Servicing discrete
becomes deactivated, the RCCBM shall open GS RCCBs and enter
in normal mode.
BITE
The RCCBM BITE function comprises power-up, continuous and
initiated tests. The BITE of the RCCBM is transmitted to the CMS
through the PEDMUs. During Interactive BITE, RCCBM only
activates the communication with PEDMU for interactive BITE.
Downloading
The RCCBM needs an aircraft configuration table to work. The aircraft
configuration table (loads presence and current rating) is downloadable
via the CAN bus between RCCBM and PEDMU. The data come from
the SCI connected to the PEDMU and are saved in the PEDMU
memory and RCCBM memory. The RCCBMs will check coherence
between their aircraft configuration table and the really installed
RCCBs in the PEPDC. The RCCBM will include a shop loading
capability for its applicative software. This mean is used to download
the software when the RCCBM is installed in the PEPDC. At "shop"
or "on aircraft" downloading, the RCCBM is downloaded lane after
lane and stays functional during "on aircraft" downloading
Maintenance Function by PDMI
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 109
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 110
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 111
A380 TECHNICAL TRAINING MANUAL
The SRPS lets the electrical starting phase of the aircraft supply the
other boards (PCDM, RCCBM, PEDMU) and particular contactors
and RCCBs.
The SRPS can be supplied by AC power from the GGPCU and the
main AC BUS. Notice that each SRPS is supplied by its related
GGPCU or AC BUS. The SRPS is also supplied with 28 VDC power
from:
- The main DC BUS 1 and 2,
- The DC ESS BUS
- The DC GROUND SERVICE BUS.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 112
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D8000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) PEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 113
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 114
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D9000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 115
A380 TECHNICAL TRAINING MANUAL
o 1 Ground Fault Interruption (GFI) board, a discreet "turn off" signal is sent to the appropriate SSPC channel(s).
o AC and DC Solid State Power Controller (SSPC) boards (commutation The GFI monitors and reports the channel trip status to the gateway.
devices).
SSPC
Gateway module The SSPCs are used for AC and DC currents switching and protection.
The Gateway module is the interface between the external world and The main functions of the SSPC are:
the SEPDC equipment. All the communication-messages to and from o Protection of the wiring against short circuit (like a circuit breaker)
the SEPDC equipment are done via this module. The Gateway o Commutation of the power (like a relay)
interfaces with the aircraft ADCN network via redundant AFDX signal A SEPDC is able to contain up to 30 AC SSPC and up to 39 DC SSPC.
(Network A and Network B). There are two redundant internal CAN This technology can replace both a circuit breaker and a relay in a
Buses between the Gateway module and other LRMs of the SEPDC. circuit and offers greater remote control flexibility by both user
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 116
A380 TECHNICAL TRAINING MANUAL
systems and Human Machine Interface (HMI). Some SSPCs are
commanded by their user ATA system, as a logic relay within a
function of that system. For this purpose, SSPCs are commanded by
the ATA system they supply (or an interfacing ATA system). The
control logic is specified in the affected ATA system design, to reduce
the need for separate logic relays in that system. For example, the
Take off lights are supplied directly from the SSPCs and they operate
when their switch is on with the nose landing gear down condition.
Other examples are found in Main Hydraulic Power, Normal Braking,
Landing Gear Control, Primary Flight Control Computer System and
Thrust Reverser logic.
L1W06161 - L0KT0T0 - LM24D9000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 117
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D9000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 118
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 119
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 120
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24D9000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SEPDC SYSTEM DESCRIPTION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 121
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SECONDARY POWER DISTRIBUTION BOX SYSTEM DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 122
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DA000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SECONDARY POWER DISTRIBUTION BOX SYSTEM DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 123
A380 TECHNICAL TRAINING MANUAL
- One Ground Fault Interruption (GFI) module, only for the AC loads in Current Transformer (CT) for Ground Leakage current feedback.
the cabin SPDB, During fault conditions, the GFI function detects unbalanced current
- AC and DC Solid State Power Controller (SSPC) modules. conditions between the supply phase/s and the return path. If the
Notice that the boards inside the SPDBs are the same than the boards amplitude and duration of the unbalance exceeds the GFI preset value,
inside the SEPDC. a discreet "turn off" signal is sent to the appropriate SSPC channel.
Communication and Control Architecture The GFI monitors and reports the channel trip status to the gateway.
The Gateway module is the interface between the external world and Power Supply Module (PSM) module
the SPDB equipment. All the communication-messages to and from Each SPDB is supplied by one PSM. The PSM supplies control power
the SPDB equipment are done via this module. The Gateway interfaces for all the LRMs within the SPDB (Gateways, GFI, AC and DC
with the aircraft ADCN network via redundant AFDX signal (Network SSPCs).
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SECONDARY POWER DISTRIBUTION BOX SYSTEM DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 124
A380 TECHNICAL TRAINING MANUAL
PDMI
The PDMI communicates with the SPDBs through the SEPDCs and
the ADCN network. PDMI sends orders in Ethernet format to the
SEPDC, which transforms it in AFDX format and sends it to the
SPDBs through the ADCN. The PDMI is used for ground maintenance
(SSPCs control and monitoring) and configuration downloading.
L1W06161 - L0KT0T0 - LM24DA000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SECONDARY POWER DISTRIBUTION BOX SYSTEM DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 125
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DA000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SECONDARY POWER DISTRIBUTION BOX SYSTEM DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 126
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) SECONDARY POWER DISTRIBUTION BOX SYSTEM DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 127
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 128
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DC000000001
SYSTEM ARCHITECTURE
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 129
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 130
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DC000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 131
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 132
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DC000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 133
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 134
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DC000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 135
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 136
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DC000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 137
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 138
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DC000000001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) POWER DISTRIBUTION MAINT INTERFACE DESC. (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 139
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 140
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DTLEVEL0201
DESCRIPTION
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 141
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 142
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DTLEVEL0201
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 143
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 144
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DTLEVEL0201
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 145
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 146
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24DTLEVEL0201
MAINTENANCE COURSE - T1 & T2 (RR / Metric) RAM AIR TURBINE STOWAGE DESCRIPTION (2) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 147
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 148
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 149
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 150
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
ESBF TESTS - OMS INTERACTIVE TESTS OVERVIEW ... CBM CONFIGURATION DUMP
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 151
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 152
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 153
A380 TECHNICAL TRAINING MANUAL
This test automatically starts a safety test and the data bus test of the
system.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 154
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 155
A380 TECHNICAL TRAINING MANUAL
This test automatically starts a safety test and the data bus test of the
system.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 156
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 157
A380 TECHNICAL TRAINING MANUAL
system.
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 158
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
SPDB 7-8 TESTS - OMS INTERACTIVE TESTS OVERVIEW ... SYSTEM TEST
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 159
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 160
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
VFG OIL - VISUAL INSPECTION OF THE VFG FOR OIL LEAKAGE AND CHECK OF THE ELECTRICAL CIRCUITS ... VISUAL INSPECTION
OF THE VFG OIL LEVEL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 161
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 162
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
VFG OIL - FILLING OF THE VFG WITH OIL OR ADDITION OF OIL AFTER A LEVEL CHECK
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 163
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 164
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 165
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 166
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24Y1MAINT0001
MAINTENANCE COURSE - T1 & T2 (RR / Metric) ELECTRICAL POWER SYSTEM MAINTENANCE (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 167
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 168
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
GENERAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 169
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 170
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 171
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 172
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 173
A380 TECHNICAL TRAINING MANUAL
DC Reconfiguration
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 174
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 175
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 176
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
ECAM PAGES
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 177
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 178
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 179
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 180
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 181
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 182
A380 TECHNICAL TRAINING MANUAL
L1W06161 - L0KT0T0 - LM24O1LEVEL0301
BITE
MAINTENANCE COURSE - T1 & T2 (RR / Metric) OPERATION, CONTROL & INDICATING (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 183
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) COMPONENT LOCATION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 184
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) COMPONENT LOCATION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 185
A380 TECHNICAL TRAINING MANUAL
A/C ZONE 260 A/C ZONE 120
DC Essential & Normal Generation Switching DC Essential Distribution
A/C ZONE 262 A/C ZONE 262
A/C ZONE 120 Refueling on Battery
Battery DC Generation (BAT) A/C ZONE 120
A/C ZONE 120 Primary & Secondary Power Distribution Interface
A/C ZONE 260 A/C ZONE 120
A/C ZONE 160
Primary Power Distribution (PEPDC)
External Power
A/C ZONE 120
A/C ZONE 120
Secondary Power Distribution (SEPDC)
DC Ground Service Bus Control
A/C ZONE 120
A/C ZONE 120
Cabin & Cargo Power Distribution (SPDB)
AC Main Distribution
A/C ZONE 220
A/C ZONE 120 A/C ZONE 230
L1W06161 - L0KT0T0 - LM24C1LEVEL0301
MAINTENANCE COURSE - T1 & T2 (RR / Metric) COMPONENT LOCATION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 186
A380 TECHNICAL TRAINING MANUAL
MAINTENANCE COURSE - T1 & T2 (RR / Metric) COMPONENT LOCATION (3) Apr 18, 2006
LEVEL III - ATA 24 Electrical Power Page 187
AIRBUS S.A.S.
31707 BLAGNAC cedex, FRANCE
STM
REFERENCE L1W06161
APRIL 2006
PRINTED IN FRANCE
AIRBUS S.A.S. 2006
ALL RIGHTS RESERVED