The Prime Controller Card (PCC) is a pluggable

microprocessor controller that provides monitoring


and control for a broad range of DC Power
Systems. The PCC monitors all system parameters
including: DC voltage, rectifier current, rectifier
temperature, system capacity, battery parameters,
and circuit breaker status.

Alarm and warning notifications are indicated by


front panel LEDs, and through potential free alarm
contacts that allow remote signaling. External
monitoring of alarms is accomplished through an
RS232 port using PC-based PowCom software.
The PCC has an Ethernet port allowing monitoring
User controls and interfaces: and control over a TCP/IP network. Alarms can
User-selectable alarm parameters mapped via SNMP traps to customer OSS
Password controlled environment platforms such as HP Openview.
RS232 Interface and Form C dry alarm To meet individual site requirements, the PCC
contacts
contains a Programmable Logic Unit that can be
Programmable alarm routing, logic unit and
used to monitor and control specified requirements.
analog inputs
This allows individual alarm routing and logic
10 Mbps Ethernet interface with integrated
web server operations to be set as actions, alarms to be
triggered, and outputs to be activated based on
40-event alarm log
internal and external signal monitoring, comparing,
Intelligent site management: and processing.
Temperature compensation with
programmable compensation factor
Automatic and manual load testing
Battery voltage and symmetry monitoring
Low voltage disconnection
North America
+1-866.513.2839

Asia-Pacific
+86.755.29885888

Europe, Middle East


+353 61 225 977
Bel Power Solutions
152 North 3rd Street, Suite 805 tech.support@psbel.com
San Jose, CA 95112 USA

2014 Bel Power Solutions, inc. BCD.00998_AB


PCC Controller Module

Voltage 30 - 60 VDC 4 potential free change-over alarm


Alarm Contacts
Current < 200 mA contacts
Low Voltage Alarm
High Voltage Alarm
Batteries on Discharge
Display 3 x 16 character LCD Overvoltage Shutdown Alarm
Internal Communication RS485 Data Bus (20 modules max.) High Load (Rectifier Capacity Alarm)
RS232 Serial interface for remote Battery Test Failure
control via modem or directly from a Battery Symmetry Alarm
PC with PowComTM software. Mains Failure
External Communication Ethernet port allowing monitoring Alarms Module Alarm
and control over a 10Mbps TCP/IP Urgent Module Alarm
network and alarm mapping via Battery Fuse Failure
SNMP traps. Load Breaker Failure
Green LED - Power ON Battery/Load Disconnect Alarm
Indications Yellow LED - System warning High Battery Temperature Alarm
Red LED - System alarm Low Battery Temperature Alarm
Battery current reading (via shunt) Temperature Probe Failure
Output voltage reading 16 x Additional User Definable Alarms
6 x analog inputs for battery
Signal Inputs symmetry reading or general use
1 x battery temperature sensor
1 x load fuse failure Allows voltage controlled
Battery Disconnection
1 x battery fuse failure disconnection of batteries.
1 x LVD disconnect Manual time controlled or automatic
1 x PLD disconnect Boost Charging boost charging with adjustable time
1 x LVD/PLD reconnect and voltage levels.
Signal Outputs
4 x Alarm contact (Form C) Automatic or manual testing of
3 x LED batteries up to six times per year.
Battery Tests
1 x LCD Variables include test duration and
Software Site upgradeable by EPROM/ Flash end voltage.
Optional tool that measures batteries
for early detection of thermal runaway.
Symmetry
Allows for separate measurements of
Measurement
Dimensions (W x H x D) 85 mm x 40 mm x 225 mm up to 6 parallel battery branches using
Weight 0.2 kg (0.44 lb) mid-point measurement.
Operating Temperature - 40 to +70 C Allows continuous adjustment of
Storage Temperature - 40 to +85 C output voltage according to battery
Temperature
EN 61000-6-2, EN 61000-6-3, temperature. Features include
EMC Compensation
EN 300 386-2 adjustable compensation factor and
Charging
separate thresholds for high
Storage: ETS 300 019-2-1
temperature alarms.
Environment Transport: ETS 300 019-2-2
Operation: ETS 300 019-2-3 Optional feature that allows voltage or
Load Shedding (PLD) time controlled disconnection of non-
essential load.

NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous
environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured.
Specifications are subject to change without notice.

866.513.2839
tech.support@psbel.com

2014 Bel Power Solutions, inc. BCD.00998_AB