7SR10 Argus

Overcurrent and Earth Fault Protection

siemens.com/reyrolle

Description
The Reyrolle 7SR10 Argus overcurrent and earth fault relay is
a numerical overcurrent protection relay intended as a
simple protection solution for distribution and industrial
applications. The relay is developed using the latest
generation of hardware technology and is available in
multiple variants depending on power supply, Binary input/
binary output configuration and data communication
facility.

Main Function Feeder protection for distribution and industrial


networks

Inputs and Outputs 4 Current Transformers with 1A and 5A


Inputs, 3 or 6 Binary Inputs and 3 or 6 Binary
Outputs

Communication Front USB, Rear RS485 port (optional) for remote


connection

Housing Size 4, 4U high - non draw-out case

Benefits Applications
Circuit breaker open and close fascia push button Feeder overcurrent protection
Protection settings can be viewed and edited from the Backup protection
fascia Compact substation
9 users programmable LEDs Protection against harmonic injection into grid by non
Cold load protection conventional sources of energy
Two setting groups Focused on renewable energy sources
Password protection - 2 levels Industry medium voltage and low voltage applications
User programmable logic aided by 8 virtual inputs /
outputs
Self Monitoring
Circuit breaker trip and maintenance counter
The last 15 fault records are displayed on the relay fascia
Waveform recorder stores 15 records (1 second
duration)


Protecting your electrical assets... today and tomorrow

Protection functions Reydisp software


46BC Broken Conductor, Load Unbalance In addition to being fully programmable via the relays
46NPS Negative Phase Sequence Overcurrent fascia keys, the 7SR10 utilises the free of charge Reydisp
49 Thermal Overload Evolution setting software package. This software
50 Instantaneous Overcurrent Protection supports setting, data and waveform analysis and
50N/G Instantaneous Earth Fault commissioning aids.
51 Time Delayed Overcurrent Protection
51N/G Time Delayed Derived / Measured Earth Fault
Protection
51C Cold Load Pickup
50BF Circuit Breaker Fail
51SEF Time Delayed Sensitive Earth Fault Protection
81HBL2 Inrush Restraint
50SEF Instantaneous Sensitive Earth Fault

Supervision Functions
Trip Circuit Supervision (74TC)
Total Harmonic Distribution Supervision (81THD)

Control Functions
86 Lockout
CB Control
79 Optional Auto Reclose

Subject to changes and errors


Siemens Protection For enquires please contact our The information given in this
Devices Limited Customer Support Center document only contains
general descriptions and / or
North Farm Road Phone: +49 180/524 8437 (24hrs) performance features which
Hebburn Fax: +49 180/524 24 71 may not always specifically
Tyne & Wear E-mail: support.ic@siemens.com reflect those described or which
NE31 1TZ www.siemens.com/protection may undergo modification in
United Kingdom the course of further
development of the products.
Article No. EMEA-B10053-00-76GB
The requested performance
Printed in the UK
features are binding only when
they are expressly agreed upon
in the concluded contract.

S-ar putea să vă placă și