INTRODUCERE N LabVIEW
1.Obiectivele lucrrii :
1. Obiectivele lucrrii
LUCRAREA NR. 3
1. Obiectivele lucrrii
You will build a VI that takes a number representing degrees Celsius and
converts it to a number representing degrees Fahrenheit. After you build a VI and
create its icon and connector pane, you can use the VI as a subVI. Then, you create
a VI that reads a measurement from the temperature sensor on the DAQ Signal
Accessory and displays the temperature in Celsius or Fahrenheit.
LUCRAREA NR. 4
1. Obiectivele lucrrii
You will build a VI that generates a signal, reduces the number of samples in the
signal, and displays the resulting data in a table on the front panel. Then, you build
a Express Filter VI, that generates a sine wave with a frequency of 10Hz and an
amplitude of 10V with white noise of 1V of amplitude and applies a fillter. Then, you
create a simple VI that acquires, analyzes, and presents data.
1. Obiectivele lucrrii
TABLOURI N LabVIEW
1. Obiectivele lucrrii
LUCRAREA NR. 7
CLUSTERE (GRUPURI)
1. Obiectivele lucrrii
LUCRAREA NR. 9
1. Obiectivele lucrrii
LUCRAREA NR. 10
1. Obiectivele lucrrii
b) NI-USB 6008
c) Precizrile din prezentul ndrumar;
LUCRAREA NR. 11
1. Obiectivele lucrrii
a To learn how to use LabVIEW for analog input through a DAQ card.
b To learn about Analog to Digital conversion and how to acquire a signal
and display it in LabVIEW.
c To study the effect of the sampling frequency in analog to digital
conversion.
In this experiment, you will write a LabVIEW VI to acquire an analog signal from the
analog input pins of the NI ELVIS, display it in LabVIEW, and calculate its RMS and
average values.
You will also show the relationship of amplitude to number of averages. This lab
requires background in analog to digital conversion and the concepts of sampling
and Nyquist sampling theorem.