Sunteți pe pagina 1din 10

GYC-1000

Bracket / Extension Coaxial illumination Dual protective filter GYC-1000 Specifications


Table for Integration probe (Endophoto Treatment Laser Frequency-Doubled Diode Pumped Solid State Laser
with a Slit Lamp probe with the coaxial Wavelength Green: 532nm
The extension table or illumination) Output power Green: 50-1700mW GREEN LASER PHOTOCOAGULATOR
Output type Continuous Wave
bracket can be used to

GYC-1000
The coaxial illumination Exposure times 0.01-3.00 seconds
integrate the GYC-1000 with probe enables one-hand Automation repeat 0.1-1.0 seconds intervals
a slit lamp for space saving operation by performing Aiming laser Red Diode
and better operability. Power supply 90-264Vac, 50/60Hz, 200VA
photocoagulation and
Dimension/ Weight 215 (W) x 280 (D) x 90 (H)mm / 6.7kg
providing lighting at the For the endophotocoagulation 8.46(W) x 11.0(D) x 3.5(H) / 14.8lbs
same time. delivery unit, the optional Optional Delivery Slit Lamp Delivery (Nidek, Zeiss, Haag Streit, etc.)
BIO Delivery, MIO Delivery
dual protective filter allows an
Endophotocoagulation Delivery
assistant to safely observe the
operation.

Carriage Handle

Extension Table

HEAD OFFICE
Fiber diameter: 200 m 34-14 Maehama, Hiroishi
Compatible devices: Nidek Gamagori, Aichi 443-0038, Japan
VT series and CV-24000 Telephone : 81-533-67-6611
Facsimile : 81-533-67-6610
URL : http://www.nidek.co.jp

Portable for remote use. TOKYO OFFICE


(International Div.)
6F Takahashi Bldg.,
Bracket 3-2 Kanda-Jinboucho

GYC-1000 Chiyoda, Tokyo 101-0051, Japan


Telephone : 81-3-3288-0571
Facsimile : 81-3-3288-0570

Optional Accessories NIDEK INC.


47651 Westinghouse Drive
Fremont, CA 94539, U.S.A.
Telephone : 1-510-226-5700
: 1-800-223-9044 (US only)
Facsimile : 1-510-226-5750
Safety Goggles Integration with the URL : http://www.nidek.com
NIDEK NIDEK TECHNOLOGIES AMERICA INC.
Phacoemulsification 5500 West Friendly Ave.
Suite 101
System CV-24000 Greensboro, NC 27410, U.S.A.
(Optional) Telephone : 1-336-851-0225
: 1-888-382-5064 (US only)
The GYC-1000 can be Facsimile : 1-336-851-0917
integrated into the NIDEK URL : http://www.nidektech.com

CV-24000 using the special CV-24000 NIDEK SOCIETE ANONYME


bracket (optional). This Europarc
13, rue Auguste Perret
integration can eliminate 94042 Creteil, France
problems such as the lack of Telephone : 33-1-49 80 97 97
For assistants, safety goggles hygiene and difficulties at Facsimile : 33-1-49 80 32 08
URL : http://www.nidek.fr
reduce the reflected beams the time of installation /
power to 1/104 or less for connection. The endophoto NIDEK TECHNOLOGIES SRL.
Via dell'Artigianato, 6 / A
their eye protection. (Note: probes can connect to the 35020 Albignasego (Padova), Italy
Do not look directly at the GYC-1000, contributing to Telephone : 39 049 8629200 / 8626399
GYC-1000 Facsimile : 39 049 8626824
emitted beam). space saving, easy setup and URL : http://www.nidektechnologies.it
simple system operation. Bracket

*Specifications and design are subject to change without notice for improvement.

Printed on environment-friendly recycled paper.

CNIDEK 2005 Printed in Japan GYC-1000 NNDIM5


Quietest Photocoagulator in the Market Detachable Control Panel 1. Slit lamp delivery unit 2. Attachable slit lamp 3. Endophotocoagulation
The new technologies - DWC and IFC functions - reduce noise The GYC-1000s compact delivery unit delivery unit
during coagulation: control panel is connected by NIDEK slit lamp Attachable to your existing slit lamp Spot size: 400 m (tip of probe)

DWC (Digital Wave Control) IFC (Intelligent Fan Control) a cord, and can be detached delivery unit ZEISS attachable slit Endophoto probe (5pcs)
(NIDEK SL-1800 type) lamp
function: function: from the main body of the (attachable to ZEISS
Spot size: 50-500 m
The DWC function reduces The CPU periodically monitors the
unit. continuously variable 30SL/M, 125/16)
the mechanical noise, as the internal temperature, and reduces The luminescent digital Protective filter unit Spot size: 50~500 m
display with optimal back (motorized / manual) continuously variable
OPEN/CLOSE movement of the noise by controlling the ON/OFF of
light provides easier Protective filter unit
internal shutter is no longer the cooling fan. In addition, the 30SL/M
necessary. The GYC-1000 controls GYC-1000 incorporates a less noisy operation in a dark room. (motorized/manual)
the laser wave by digital signal fan so the system is quiet even With a slit lamp delivery unit, 125/16 (manual) Protective filter unit
from the CPU. when the fan is working. the spot size indication on (Usable with ZEISS
ZEISS SL130 delivery HAAG attachable slit or WILD surgical
Noise Difference: the control panel enables
lamp microscope)
(Increase from room noise) setting and confirmation all Spot size: 50-500 m
continuously variable (attachable to HAAG
Former GYC 16.7db at once. STREIT 900BM type) 4. Combination delivery
GYC-1000 1.6db Protective filter unit
(motorized) Spot size: 50-500 m unit
continuously variable
Attachable to NIDEK OPTHALMIC YAG
LASER YC-1300/1400/1600/1800
True Continuous Wave (CW)
The GYC-1000s solid state

Average Output Power


laser is a true continuous

Output Power
* HAAG STREIT 900BQ, 900CN and NIDEK
wave (CW), not a pulsed laser. SL-450, 250 are also attachable
CW laser delivery assures
predictable treatment results
by eliminating the potential
Coagulation Time Coagulation Time
risks associated with pulsed
laser systems. Continuous Wave Pulsed Laser A dual-application combination
photocoagulator / Yag laser system.

NIDEK GYC-1000 GYC-1000 GYC-1000


Flexibility & Versatility Superior Performance Optional Delivery Units
Universal Design The Worlds Smallest Lowest Power 532nm Green Laser Treatment With Safety Features 5. Binocular indirect ophthalmoscope delivery unit 6. Monocular indirect
The NIDEK GYC-1000 utilizes Green Laser on the Requirement Efficient, safe Precision The GYC-1000 has a variety Adjustable working distance allows effective photocoagulation at ophthalmoscope
a diode pumped solid-state Market The new technology - ITC photocoagulation is a Exposure time of conventional of safety features: it is the most favorable distance. delivery unit
laser to achieve maximum The compact ( W215 x D280 x (Intelligent Thermo Control) hallmark of the GYC-1000. lasers can be adjusted in 0.10 equipped with a filter that
laser life and the greatest function - reduces the power The 532nm laser beam passes second increments, from 0.10 reduces the power of the Keeler All Pupil HEINE OMEGA 180 type NEITZ BS- type
H90 mm) and lightweight
efficiency at low heat requirement, offering through the ocular media to 1.00 seconds. reflected green laser to 1/104 Spot size: 185 (WD300)-556 Spot size: 180 (WD300)-520 Spot size: 262 (WD300)-752
(6.7kg / 14.8lbs) console
emission. optimum and economical with low attenuation to The GYC-1000s exposure or less; the error indicator (WD700) m (WD700) m (WD700) m
offers maximum operational
The GYC-1000 laser can be minimize power loss. function displays the nature (variable according to the working (variable according to the working (variable according to the working
flexibility and treatment control of the temperature time can be adjusted in 0.05
distance) distance) distance)
plugged into any standard versatility - from the office to under CPU management. - Higher absorption by the second increments from 0.10 of the error encountered on
power outlet and requires no the O.R. pigment epitheliopathy, to 0.50 seconds, which is the the time display of the
external hookup for High Reliability hemoglobin, and oxidized most widely used range for control panel; the system
operation, yet achieves high 215mm hemoglobin photocoagulation. The finer conducts a self-diagnosis to
A digitally controlled instant
power output (max. 1700mW 280mm - Lower absorption by the adjustments provide more monitor the system
duty cycle permits the laser to
on the cornea). 90mm xanthophyll pigment precise treatment for patients. condition; and more.
be used at very fast speeds
The GYC-1000s specially
and high powers for Oxyhemoglobin
designed silent air cooling Hemoglobin
Exposure time
extended periods of time RPE
Xanthophyll
system minimizes the typical 0.01-0.10s (0.01s increment)
without failure.

575.0-
maintenance problems

488.0

514.5
532.0

630.0

647.1
The GYC-1000 provides many 0.10-0.50s (0.05s increment)
common to conventional 100
0.50-1.00s (0.10s increment)
years of superior, reliable
plasma tube technology. Ergonomically easy to handle. 80
1.00-3.00s (1.00s increment)
performance. Lightweight with bright, clear
Absorption

60

40
illumination.
(%)

20

Wavelength(nm) 400 500 600 700


Quietest Photocoagulator in the Market Detachable Control Panel 1. Slit lamp delivery unit 2. Attachable slit lamp 3. Endophotocoagulation
The new technologies - DWC and IFC functions - reduce noise The GYC-1000s compact delivery unit delivery unit
during coagulation: control panel is connected by NIDEK slit lamp Attachable to your existing slit lamp Spot size: 400 m (tip of probe)

DWC (Digital Wave Control) IFC (Intelligent Fan Control) a cord, and can be detached delivery unit ZEISS attachable slit Endophoto probe (5pcs)
(NIDEK SL-1800 type) lamp
function: function: from the main body of the (attachable to ZEISS
Spot size: 50-500 m
The DWC function reduces The CPU periodically monitors the
unit. continuously variable 30SL/M, 125/16)
the mechanical noise, as the internal temperature, and reduces The luminescent digital Protective filter unit Spot size: 50~500 m
display with optimal back (motorized / manual) continuously variable
OPEN/CLOSE movement of the noise by controlling the ON/OFF of
light provides easier Protective filter unit
internal shutter is no longer the cooling fan. In addition, the 30SL/M
necessary. The GYC-1000 controls GYC-1000 incorporates a less noisy operation in a dark room. (motorized/manual)
the laser wave by digital signal fan so the system is quiet even With a slit lamp delivery unit, 125/16 (manual) Protective filter unit
from the CPU. when the fan is working. the spot size indication on (Usable with ZEISS
ZEISS SL130 delivery HAAG attachable slit or WILD surgical
Noise Difference: the control panel enables
lamp microscope)
(Increase from room noise) setting and confirmation all Spot size: 50-500 m
continuously variable (attachable to HAAG
Former GYC 16.7db at once. STREIT 900BM type) 4. Combination delivery
GYC-1000 1.6db Protective filter unit
(motorized) Spot size: 50-500 m unit
continuously variable
Attachable to NIDEK OPTHALMIC YAG
LASER YC-1300/1400/1600/1800
True Continuous Wave (CW)
The GYC-1000s solid state

Average Output Power


laser is a true continuous

Output Power
* HAAG STREIT 900BQ, 900CN and NIDEK
wave (CW), not a pulsed laser. SL-450, 250 are also attachable
CW laser delivery assures
predictable treatment results
by eliminating the potential
Coagulation Time Coagulation Time
risks associated with pulsed
laser systems. Continuous Wave Pulsed Laser A dual-application combination
photocoagulator / Yag laser system.

NIDEK GYC-1000 GYC-1000 GYC-1000


Flexibility & Versatility Superior Performance Optional Delivery Units
Universal Design The Worlds Smallest Lowest Power 532nm Green Laser Treatment With Safety Features 5. Binocular indirect ophthalmoscope delivery unit 6. Monocular indirect
The NIDEK GYC-1000 utilizes Green Laser on the Requirement Efficient, safe Precision The GYC-1000 has a variety Adjustable working distance allows effective photocoagulation at ophthalmoscope
a diode pumped solid-state Market The new technology - ITC photocoagulation is a Exposure time of conventional of safety features: it is the most favorable distance. delivery unit
laser to achieve maximum The compact ( W215 x D280 x (Intelligent Thermo Control) hallmark of the GYC-1000. lasers can be adjusted in 0.10 equipped with a filter that
laser life and the greatest function - reduces the power The 532nm laser beam passes second increments, from 0.10 reduces the power of the Keeler All Pupil HEINE OMEGA 180 type NEITZ BS- type
H90 mm) and lightweight
efficiency at low heat requirement, offering through the ocular media to 1.00 seconds. reflected green laser to 1/104 Spot size: 185 (WD300)-556 Spot size: 180 (WD300)-520 Spot size: 262 (WD300)-752
(6.7kg / 14.8lbs) console
emission. optimum and economical with low attenuation to The GYC-1000s exposure or less; the error indicator (WD700) m (WD700) m (WD700) m
offers maximum operational
The GYC-1000 laser can be minimize power loss. function displays the nature (variable according to the working (variable according to the working (variable according to the working
flexibility and treatment control of the temperature time can be adjusted in 0.05
distance) distance) distance)
plugged into any standard versatility - from the office to under CPU management. - Higher absorption by the second increments from 0.10 of the error encountered on
power outlet and requires no the O.R. pigment epitheliopathy, to 0.50 seconds, which is the the time display of the
external hookup for High Reliability hemoglobin, and oxidized most widely used range for control panel; the system
operation, yet achieves high 215mm hemoglobin photocoagulation. The finer conducts a self-diagnosis to
A digitally controlled instant
power output (max. 1700mW 280mm - Lower absorption by the adjustments provide more monitor the system
duty cycle permits the laser to
on the cornea). 90mm xanthophyll pigment precise treatment for patients. condition; and more.
be used at very fast speeds
The GYC-1000s specially
and high powers for Oxyhemoglobin
designed silent air cooling Hemoglobin
Exposure time
extended periods of time RPE
Xanthophyll
system minimizes the typical 0.01-0.10s (0.01s increment)
without failure.

575.0-
maintenance problems

488.0

514.5
532.0

630.0

647.1
The GYC-1000 provides many 0.10-0.50s (0.05s increment)
common to conventional 100
0.50-1.00s (0.10s increment)
years of superior, reliable
plasma tube technology. Ergonomically easy to handle. 80
1.00-3.00s (1.00s increment)
performance. Lightweight with bright, clear
Absorption

60

40
illumination.
(%)

20

Wavelength(nm) 400 500 600 700


Quietest Photocoagulator in the Market Detachable Control Panel 1. Slit lamp delivery unit 2. Attachable slit lamp 3. Endophotocoagulation
The new technologies - DWC and IFC functions - reduce noise The GYC-1000s compact delivery unit delivery unit
during coagulation: control panel is connected by NIDEK slit lamp Attachable to your existing slit lamp Spot size: 400 m (tip of probe)

DWC (Digital Wave Control) IFC (Intelligent Fan Control) a cord, and can be detached delivery unit ZEISS attachable slit Endophoto probe (5pcs)
(NIDEK SL-1800 type) lamp
function: function: from the main body of the (attachable to ZEISS
Spot size: 50-500 m
The DWC function reduces The CPU periodically monitors the
unit. continuously variable 30SL/M, 125/16)
the mechanical noise, as the internal temperature, and reduces The luminescent digital Protective filter unit Spot size: 50~500 m
display with optimal back (motorized / manual) continuously variable
OPEN/CLOSE movement of the noise by controlling the ON/OFF of
light provides easier Protective filter unit
internal shutter is no longer the cooling fan. In addition, the 30SL/M
necessary. The GYC-1000 controls GYC-1000 incorporates a less noisy operation in a dark room. (motorized/manual)
the laser wave by digital signal fan so the system is quiet even With a slit lamp delivery unit, 125/16 (manual) Protective filter unit
from the CPU. when the fan is working. the spot size indication on (Usable with ZEISS
ZEISS SL130 delivery HAAG attachable slit or WILD surgical
Noise Difference: the control panel enables
lamp microscope)
(Increase from room noise) setting and confirmation all Spot size: 50-500 m
continuously variable (attachable to HAAG
Former GYC 16.7db at once. STREIT 900BM type) 4. Combination delivery
GYC-1000 1.6db Protective filter unit
(motorized) Spot size: 50-500 m unit
continuously variable
Attachable to NIDEK OPTHALMIC YAG
LASER YC-1300/1400/1600/1800
True Continuous Wave (CW)
The GYC-1000s solid state

Average Output Power


laser is a true continuous

Output Power
* HAAG STREIT 900BQ, 900CN and NIDEK
wave (CW), not a pulsed laser. SL-450, 250 are also attachable
CW laser delivery assures
predictable treatment results
by eliminating the potential
Coagulation Time Coagulation Time
risks associated with pulsed
laser systems. Continuous Wave Pulsed Laser A dual-application combination
photocoagulator / Yag laser system.

NIDEK GYC-1000 GYC-1000 GYC-1000


Flexibility & Versatility Superior Performance Optional Delivery Units
Universal Design The Worlds Smallest Lowest Power 532nm Green Laser Treatment With Safety Features 5. Binocular indirect ophthalmoscope delivery unit 6. Monocular indirect
The NIDEK GYC-1000 utilizes Green Laser on the Requirement Efficient, safe Precision The GYC-1000 has a variety Adjustable working distance allows effective photocoagulation at ophthalmoscope
a diode pumped solid-state Market The new technology - ITC photocoagulation is a Exposure time of conventional of safety features: it is the most favorable distance. delivery unit
laser to achieve maximum The compact ( W215 x D280 x (Intelligent Thermo Control) hallmark of the GYC-1000. lasers can be adjusted in 0.10 equipped with a filter that
laser life and the greatest function - reduces the power The 532nm laser beam passes second increments, from 0.10 reduces the power of the Keeler All Pupil HEINE OMEGA 180 type NEITZ BS- type
H90 mm) and lightweight
efficiency at low heat requirement, offering through the ocular media to 1.00 seconds. reflected green laser to 1/104 Spot size: 185 (WD300)-556 Spot size: 180 (WD300)-520 Spot size: 262 (WD300)-752
(6.7kg / 14.8lbs) console
emission. optimum and economical with low attenuation to The GYC-1000s exposure or less; the error indicator (WD700) m (WD700) m (WD700) m
offers maximum operational
The GYC-1000 laser can be minimize power loss. function displays the nature (variable according to the working (variable according to the working (variable according to the working
flexibility and treatment control of the temperature time can be adjusted in 0.05
distance) distance) distance)
plugged into any standard versatility - from the office to under CPU management. - Higher absorption by the second increments from 0.10 of the error encountered on
power outlet and requires no the O.R. pigment epitheliopathy, to 0.50 seconds, which is the the time display of the
external hookup for High Reliability hemoglobin, and oxidized most widely used range for control panel; the system
operation, yet achieves high 215mm hemoglobin photocoagulation. The finer conducts a self-diagnosis to
A digitally controlled instant
power output (max. 1700mW 280mm - Lower absorption by the adjustments provide more monitor the system
duty cycle permits the laser to
on the cornea). 90mm xanthophyll pigment precise treatment for patients. condition; and more.
be used at very fast speeds
The GYC-1000s specially
and high powers for Oxyhemoglobin
designed silent air cooling Hemoglobin
Exposure time
extended periods of time RPE
Xanthophyll
system minimizes the typical 0.01-0.10s (0.01s increment)
without failure.

575.0-
maintenance problems

488.0

514.5
532.0

630.0

647.1
The GYC-1000 provides many 0.10-0.50s (0.05s increment)
common to conventional 100
0.50-1.00s (0.10s increment)
years of superior, reliable
plasma tube technology. Ergonomically easy to handle. 80
1.00-3.00s (1.00s increment)
performance. Lightweight with bright, clear
Absorption

60

40
illumination.
(%)

20

Wavelength(nm) 400 500 600 700


GYC-1000
Bracket / Extension Coaxial illumination Dual protective filter GYC-1000 Specifications
Table for Integration probe (Endophoto Treatment Laser Frequency-Doubled Diode Pumped Solid State Laser
with a Slit Lamp probe with the coaxial Wavelength Green: 532nm
The extension table or illumination) Output power Green: 50-1700mW GREEN LASER PHOTOCOAGULATOR
Output type Continuous Wave
bracket can be used to

GYC-1000
The coaxial illumination Exposure times 0.01-3.00 seconds
integrate the GYC-1000 with probe enables one-hand Automation repeat 0.1-1.0 seconds intervals
a slit lamp for space saving operation by performing Aiming laser Red Diode
and better operability. Power supply 90-264Vac, 50/60Hz, 200VA
photocoagulation and
Dimension/ Weight 215 (W) x 280 (D) x 90 (H)mm / 6.7kg
providing lighting at the For the endophotocoagulation 8.46(W) x 11.0(D) x 3.5(H) / 14.8lbs
same time. delivery unit, the optional Optional Delivery Slit Lamp Delivery (Nidek, Zeiss, Haag Streit, etc.)
BIO Delivery, MIO Delivery
dual protective filter allows an
Endophotocoagulation Delivery
assistant to safely observe the
operation.

Carriage Handle

Extension Table

HEAD OFFICE
Fiber diameter: 200 m 34-14 Maehama, Hiroishi
Compatible devices: Nidek Gamagori, Aichi 443-0038, Japan
VT series and CV-24000 Telephone : 81-533-67-6611
Facsimile : 81-533-67-6610
URL : http://www.nidek.co.jp

Portable for remote use. TOKYO OFFICE


(International Div.)
6F Takahashi Bldg.,
Bracket 3-2 Kanda-Jinboucho

GYC-1000 Chiyoda, Tokyo 101-0051, Japan


Telephone : 81-3-3288-0571
Facsimile : 81-3-3288-0570

Optional Accessories NIDEK INC.


47651 Westinghouse Drive
Fremont, CA 94539, U.S.A.
Telephone : 1-510-226-5700
: 1-800-223-9044 (US only)
Facsimile : 1-510-226-5750
Safety Goggles Integration with the URL : http://www.nidek.com
NIDEK NIDEK TECHNOLOGIES AMERICA INC.
Phacoemulsification 5500 West Friendly Ave.
Suite 101
System CV-24000 Greensboro, NC 27410, U.S.A.
(Optional) Telephone : 1-336-851-0225
: 1-888-382-5064 (US only)
The GYC-1000 can be Facsimile : 1-336-851-0917
integrated into the NIDEK URL : http://www.nidektech.com

CV-24000 using the special CV-24000 NIDEK SOCIETE ANONYME


bracket (optional). This Europarc
13, rue Auguste Perret
integration can eliminate 94042 Creteil, France
problems such as the lack of Telephone : 33-1-49 80 97 97
For assistants, safety goggles hygiene and difficulties at Facsimile : 33-1-49 80 32 08
URL : http://www.nidek.fr
reduce the reflected beams the time of installation /
power to 1/104 or less for connection. The endophoto NIDEK TECHNOLOGIES SRL.
Via dell'Artigianato, 6 / A
their eye protection. (Note: probes can connect to the 35020 Albignasego (Padova), Italy
Do not look directly at the GYC-1000, contributing to Telephone : 39 049 8629200 / 8626399
GYC-1000 Facsimile : 39 049 8626824
emitted beam). space saving, easy setup and URL : http://www.nidektechnologies.it
simple system operation. Bracket

*Specifications and design are subject to change without notice for improvement.

Printed on environment-friendly recycled paper.

CNIDEK 2005 Printed in Japan GYC-1000 NNDIM5


GYC-1000
Bracket / Extension Coaxial illumination Dual protective filter GYC-1000 Specifications
Table for Integration probe (Endophoto Treatment Laser Frequency-Doubled Diode Pumped Solid State Laser
with a Slit Lamp probe with the coaxial Wavelength Green: 532nm
The extension table or illumination) Output power Green: 50-1700mW GREEN LASER PHOTOCOAGULATOR
Output type Continuous Wave
bracket can be used to

GYC-1000
The coaxial illumination Exposure times 0.01-3.00 seconds
integrate the GYC-1000 with probe enables one-hand Automation repeat 0.1-1.0 seconds intervals
a slit lamp for space saving operation by performing Aiming laser Red Diode
and better operability. Power supply 90-264Vac, 50/60Hz, 200VA
photocoagulation and
Dimension/ Weight 215 (W) x 280 (D) x 90 (H)mm / 6.7kg
providing lighting at the For the endophotocoagulation 8.46(W) x 11.0(D) x 3.5(H) / 14.8lbs
same time. delivery unit, the optional Optional Delivery Slit Lamp Delivery (Nidek, Zeiss, Haag Streit, etc.)
BIO Delivery, MIO Delivery
dual protective filter allows an
Endophotocoagulation Delivery
assistant to safely observe the
operation.

Carriage Handle

Extension Table

HEAD OFFICE
Fiber diameter: 200 m 34-14 Maehama, Hiroishi
Compatible devices: Nidek Gamagori, Aichi 443-0038, Japan
VT series and CV-24000 Telephone : 81-533-67-6611
Facsimile : 81-533-67-6610
URL : http://www.nidek.co.jp

Portable for remote use. TOKYO OFFICE


(International Div.)
6F Takahashi Bldg.,
Bracket 3-2 Kanda-Jinboucho

GYC-1000 Chiyoda, Tokyo 101-0051, Japan


Telephone : 81-3-3288-0571
Facsimile : 81-3-3288-0570

Optional Accessories NIDEK INC.


47651 Westinghouse Drive
Fremont, CA 94539, U.S.A.
Telephone : 1-510-226-5700
: 1-800-223-9044 (US only)
Facsimile : 1-510-226-5750
Safety Goggles Integration with the URL : http://www.nidek.com
NIDEK NIDEK TECHNOLOGIES AMERICA INC.
Phacoemulsification 5500 West Friendly Ave.
Suite 101
System CV-24000 Greensboro, NC 27410, U.S.A.
(Optional) Telephone : 1-336-851-0225
: 1-888-382-5064 (US only)
The GYC-1000 can be Facsimile : 1-336-851-0917
integrated into the NIDEK URL : http://www.nidektech.com

CV-24000 using the special CV-24000 NIDEK SOCIETE ANONYME


bracket (optional). This Europarc
13, rue Auguste Perret
integration can eliminate 94042 Creteil, France
problems such as the lack of Telephone : 33-1-49 80 97 97
For assistants, safety goggles hygiene and difficulties at Facsimile : 33-1-49 80 32 08
URL : http://www.nidek.fr
reduce the reflected beams the time of installation /
power to 1/104 or less for connection. The endophoto NIDEK TECHNOLOGIES SRL.
Via dell'Artigianato, 6 / A
their eye protection. (Note: probes can connect to the 35020 Albignasego (Padova), Italy
Do not look directly at the GYC-1000, contributing to Telephone : 39 049 8629200 / 8626399
GYC-1000 Facsimile : 39 049 8626824
emitted beam). space saving, easy setup and URL : http://www.nidektechnologies.it
simple system operation. Bracket

*Specifications and design are subject to change without notice for improvement.

Printed on environment-friendly recycled paper.

CNIDEK 2005 Printed in Japan GYC-1000 NNDIM5


YC-1800
YC-1800 Specifications
Treatment Laser
Type Nd:YAG
Wavelength 1064nm
Mode Structure Fundamental
Pulse Duration 4 nsec
Mode of Operation Q-switched
Pulse Repetition Rate 3Hz (single) / 1.5Hz (burst)
Output Energy 0.3-10.0mJ/pulse (Continuously variable)
Burst Mode 2 or 3 pulse/trigger Portable & User-Friendly
Spot Size 8m
Cone Angle 16
Focal Shift

Aiming Laser
0-500m (Continuously variable, toward both anterior chamber and
posterior chamber) YC-1800
Type Diode laser
Wavelength
Output Power
635nm
OFF, 0.5-25W
OPHTHALMIC YAG LASER SYSTEM
Cone Angle 16
Aiming Method Dual beam method
Rotation of Beam 360
Slit Lamp
Objective Lens f=130mm
Eye Piece 12.5x
Magnification (field of view) 32x(6.2mm), 20x(10mm), 12.5x(16mm), 8x(25mm), 5x(40mm) HEAD OFFICE
Power Supply Single-phase, 100-240Vac, 50/60Hz, 100VA 34-14 Maehama, Hiroishi
Dimension / Weight 324 (W) x 407(D) x 528.5(H) mm / 16kg Gamagori, Aichi 443-0038, Japan
12.8(W) x 16 (D) x 20.8 (H) " / 35.3lbs. Telephone : 81-533-67-6611
Facsimile : 81-533-67-6610
Standard Accessories Head belt, Arm rest, Key swtich, Slit lamp bulb, Chin rest pads URL : http://www.nidek.co.jp
Optional Accessories Motorized optical table, Foot switch, Safety goggles
TOKYO OFFICE
(International Div.)
*Manufacturer 3F Sumitomo Fudosan Hongo Bldg.,
NIDEK Co., LTD. 3-22-5 Hongo, Bunkyo-ku, Tokyo,
34-14, Maehama, Hiroishi, Gamagori, Aichi 443-0038, Japan 113-0033 Japan
Telephone : 81-3-5844-2641
Caution: U.S. Federal Law restricts this device to sale, distribution and use by or on the order of a Facsimile : 81-3-5844-2642
physician or other licensed eye care practitioner. URL : http://www.nidek.com

NIDEK INC.
47651 Westinghouse Drive
Fremont, CA 94539, U.S.A.
Telephone : 1-510-226-5700
: 1-800-223-9044 (US only)
Facsimile : 1-510-226-5750
URL : http://www.usa.nidek.com

NIDEK SOCIETE ANONYME


Europarc
13, rue Auguste Perret
94042 Creteil, France
Telephone : 33-1-49 80 97 97
Facsimile : 33-1-49 80 32 08
URL : http://www.nidek.fr

NIDEK TECHNOLOGIES SRL.


Via dell'Artigianato, 6 / A
35020 Albignasego (Padova), Italy
Telephone : 39 049 8629200 / 8626399
Facsimile : 39 049 8626824
VISIBLE AND INVISIBLE URL : http://www.nidektechnologies.it
LASER RADIATION
AVOID EXPOSURE TO BEAM
VISIBLE AND INVISIBLE LASER CLASS 3B LASER PRODUCT
RADIATION - AVOID DIRECT YAG LASER, 1064nm, 4ns, 25mJ max.
EXPOSURE TO BEAM
DIODE LASER, 635nm, CW, 5mW max.
YAG, 1064nm, 25mJ/PULSE, 4 nsec
IEC 60825-1 2001 13706-M824-A
DIODE, 635nm, CW, 5mW (MAX)
CLASS b LASER PRODUCT

*Specifications and design are subject to change without notice for improvement.

Printed on environment-friendly recycled paper.

CNIDEK 2006 Printed in Japan YC-1800 NOEGM6


OPHTHALMIC YAG LASER SYSTEM
YC-1800
Portable & User-Friendly Design Reliability and Safety

Improved Operability Compact & Slim Design Reliable Laser Output Safer Rotating Aiming Beam
The Smart Switch (patent pending) located The NIDEK YC-1800 is the smallest and lightest The YC-1800 employs the new technology to The dual 635nm aiming beam offers superior
on the joystick provides high operability, ophthalmic photodisruptor available and can control the pulse number under the CPU visual sensitivity, which in turn enhances the
allowing doctors to change parameters (Energy be easily transported. Compact and slim design D-Pulse (patent pending), providing higher speed and ease of operation. The 635nm beam
up, Energy down and Ready/Standby *) while also allows greater flexibility in locating your stability against environmental conditions and is also safer to human eyes since it achieves the
holding the joystick. arm rest. change over time. same crisp and sharp intensity of 650nm or
Permits faster and easier operation, and 670nm beam with half the power output. The
eliminates need to look away from oculars to YC-1800 has the ability to rotate the dual
make parameter adjustments. Versatile Combo Lasers aiming beams 360 permitting work anywhere
The YC-1800 can be easily connected to NIDEKs Fast Operation in the periphery without clipping the iris.
* Factory setting.
The user has three choices from among energy up, Green Laser Photocoagulator (GYC-1000), The 3Hz firing rate is the fastest available,
energy down, ready/standby, aiming up, aiming down, allowing treatment of a wider range of which can be very practical when encountering
burst and reset.
patients and indications. a moving eye or other patient difficulties. The
360 degree-manual rotation
Space requirements are minimized, and the YC-1800 can treat a wide variety of diseases, of the aiming beam for
combination adapter (optional) includes the and its speed and efficiency allows comfortable precise operation.
split mirror illumination tower. operation.

The YC-GYC Great Number of Energy


changeover lever Settings
Unique Joystick Smart Switch The YC-1800 offers 0.3-10mJ, continuously
adjustable in increments of 0.1mJ, allowing the
most precise tissue effect.
One-Touch Lock
The YC-1800 can smoothly slide back and forth
and around, and the unit can be easily fixed
and released at anywhere you like with the Super Adjustable Nd:YAG
one-touch lock, offering high operability with Offset
improved safety. The YC-1800 has the exclusive ability to adjust
the offset 500 microns (25 micron steps) to
best meet your varied clinical needs.
A different offset can be used for PMMA,
silicone or acrylic lenses, and the offset can
even be adjusted on the same IOL to
compensate for a parallax effect in the
periphery. This eliminates the need to manually
defocus, permits a clear field of view, and
minimizes lens pitting.
OPHTHALMIC YAG LASER SYSTEM
YC-1800
Portable & User-Friendly Design Reliability and Safety

Improved Operability Compact & Slim Design Reliable Laser Output Safer Rotating Aiming Beam
The Smart Switch (patent pending) located The NIDEK YC-1800 is the smallest and lightest The YC-1800 employs the new technology to The dual 635nm aiming beam offers superior
on the joystick provides high operability, ophthalmic photodisruptor available and can control the pulse number under the CPU visual sensitivity, which in turn enhances the
allowing doctors to change parameters (Energy be easily transported. Compact and slim design D-Pulse (patent pending), providing higher speed and ease of operation. The 635nm beam
up, Energy down and Ready/Standby *) while also allows greater flexibility in locating your stability against environmental conditions and is also safer to human eyes since it achieves the
holding the joystick. arm rest. change over time. same crisp and sharp intensity of 650nm or
Permits faster and easier operation, and 670nm beam with half the power output. The
eliminates need to look away from oculars to YC-1800 has the ability to rotate the dual
make parameter adjustments. Versatile Combo Lasers aiming beams 360 permitting work anywhere
The YC-1800 can be easily connected to NIDEKs Fast Operation in the periphery without clipping the iris.
* Factory setting.
The user has three choices from among energy up, Green Laser Photocoagulator (GYC-1000), The 3Hz firing rate is the fastest available,
energy down, ready/standby, aiming up, aiming down, allowing treatment of a wider range of which can be very practical when encountering
burst and reset.
patients and indications. a moving eye or other patient difficulties. The
360 degree-manual rotation
Space requirements are minimized, and the YC-1800 can treat a wide variety of diseases, of the aiming beam for
combination adapter (optional) includes the and its speed and efficiency allows comfortable precise operation.
split mirror illumination tower. operation.

The YC-GYC Great Number of Energy


changeover lever Settings
Unique Joystick Smart Switch The YC-1800 offers 0.3-10mJ, continuously
adjustable in increments of 0.1mJ, allowing the
most precise tissue effect.
One-Touch Lock
The YC-1800 can smoothly slide back and forth
and around, and the unit can be easily fixed
and released at anywhere you like with the Super Adjustable Nd:YAG
one-touch lock, offering high operability with Offset
improved safety. The YC-1800 has the exclusive ability to adjust
the offset 500 microns (25 micron steps) to
best meet your varied clinical needs.
A different offset can be used for PMMA,
silicone or acrylic lenses, and the offset can
even be adjusted on the same IOL to
compensate for a parallax effect in the
periphery. This eliminates the need to manually
defocus, permits a clear field of view, and
minimizes lens pitting.
YC-1800
YC-1800 Specifications
Treatment Laser
Type Nd:YAG
Wavelength 1064nm
Mode Structure Fundamental
Pulse Duration 4 nsec
Mode of Operation Q-switched
Pulse Repetition Rate 3Hz (single) / 1.5Hz (burst)
Output Energy 0.3-10.0mJ/pulse (Continuously variable)
Burst Mode 2 or 3 pulse/trigger Portable & User-Friendly
Spot Size 8m
Cone Angle 16
Focal Shift

Aiming Laser
0-500m (Continuously variable, toward both anterior chamber and
posterior chamber) YC-1800
Type Diode laser
Wavelength
Output Power
635nm
OFF, 0.5-25W
OPHTHALMIC YAG LASER SYSTEM
Cone Angle 16
Aiming Method Dual beam method
Rotation of Beam 360
Slit Lamp
Objective Lens f=130mm
Eye Piece 12.5x
Magnification (field of view) 32x(6.2mm), 20x(10mm), 12.5x(16mm), 8x(25mm), 5x(40mm) HEAD OFFICE
Power Supply Single-phase, 100-240Vac, 50/60Hz, 100VA 34-14 Maehama, Hiroishi
Dimension / Weight 324 (W) x 407(D) x 528.5(H) mm / 16kg Gamagori, Aichi 443-0038, Japan
12.8(W) x 16 (D) x 20.8 (H) " / 35.3lbs. Telephone : 81-533-67-6611
Facsimile : 81-533-67-6610
Standard Accessories Head belt, Arm rest, Key swtich, Slit lamp bulb, Chin rest pads URL : http://www.nidek.co.jp
Optional Accessories Motorized optical table, Foot switch, Safety goggles
TOKYO OFFICE
(International Div.)
*Manufacturer 3F Sumitomo Fudosan Hongo Bldg.,
NIDEK Co., LTD. 3-22-5 Hongo, Bunkyo-ku, Tokyo,
34-14, Maehama, Hiroishi, Gamagori, Aichi 443-0038, Japan 113-0033 Japan
Telephone : 81-3-5844-2641
Caution: U.S. Federal Law restricts this device to sale, distribution and use by or on the order of a Facsimile : 81-3-5844-2642
physician or other licensed eye care practitioner. URL : http://www.nidek.com

NIDEK INC.
47651 Westinghouse Drive
Fremont, CA 94539, U.S.A.
Telephone : 1-510-226-5700
: 1-800-223-9044 (US only)
Facsimile : 1-510-226-5750
URL : http://www.usa.nidek.com

NIDEK SOCIETE ANONYME


Europarc
13, rue Auguste Perret
94042 Creteil, France
Telephone : 33-1-49 80 97 97
Facsimile : 33-1-49 80 32 08
URL : http://www.nidek.fr

NIDEK TECHNOLOGIES SRL.


Via dell'Artigianato, 6 / A
35020 Albignasego (Padova), Italy
Telephone : 39 049 8629200 / 8626399
Facsimile : 39 049 8626824
VISIBLE AND INVISIBLE URL : http://www.nidektechnologies.it
LASER RADIATION
AVOID EXPOSURE TO BEAM
VISIBLE AND INVISIBLE LASER CLASS 3B LASER PRODUCT
RADIATION - AVOID DIRECT YAG LASER, 1064nm, 4ns, 25mJ max.
EXPOSURE TO BEAM
DIODE LASER, 635nm, CW, 5mW max.
YAG, 1064nm, 25mJ/PULSE, 4 nsec
IEC 60825-1 2001 13706-M824-A
DIODE, 635nm, CW, 5mW (MAX)
CLASS b LASER PRODUCT

*Specifications and design are subject to change without notice for improvement.

Printed on environment-friendly recycled paper.

CNIDEK 2006 Printed in Japan YC-1800 NOEGM6

S-ar putea să vă placă și