Sunteți pe pagina 1din 6

Form CIDB IBS Score M1 (rev.

2010)

CALCULATION FOR IBS SCORE


For Office Use
Project Registration No:

Project Category:

Project Name: Contract Value: RM18 million

IBS SCORE for MEREKABENTUK, MEMBINA DAN


MENYIAPKAN UNIT RUMAH TERES DAN

Contractor Name: Developer / Owner Name :

Architect Consultant : Civil & Structural Engineer Consultant Name :


ARCHITECTS PERUNDING CSS
No.17-3,Jalan OP 1/2,
One Puchong Business Park,
47100 Puchong,Selangor Darul Ehsan.

List of Submitted Drawings


1) 6)
2) 7)
3) 8)
4) 9)
5) 10)

We hereby declare that the information given and the IBS Score submitted herewith is true and complete.

The total IBS Score for the proposed building / project is 70.33

Date : 20/04/2017 Name & Signature of Qualified Person


CALCULATIONS OF OVERALL IBS SCORE

PROJECT DETAILS

Project Name : CADANGAN PEMBANGUNAN BLOK TERES 2 TINGKAT ( UNIT) DI ATAS LOT

Type / Block No: Terrace House Total no of Units / Blocks: 1

Contract Value : RM mil

Category of Building

Residential (Landed) Industrial Commercial

Residential (high rise) Institutional Others

For mixed decelopment, please indicate the area of the category:

Residential (landed) - m2 Industrial - m2

Residential (high rise) - m2 Institutional - m2

Commercial - m2 Others - m2
IBS SCORE for MEREKABENTUK, MEMBINA DAN MENYIAPKAN UNIT RUMAH TERES

Source: Manual for IBS Content Scoring System (IBS Score) - ISBN 983-2724-30-9

IBS Score = Score for Structural Systems + Score for Wall System + Score for Other Simplified Construction
System

50[(Qs/Qst)xFs] + 30[(Qw/Qwt)xFw] + S

where : Qs Construction area of a structural system


Qst Total construction area of building
Fs IBS Factor for structural system for Table 1
Qw Length of wall system (external or internal wall)
Qwt Total wall length (external or internal wall length)
Fw IBS Factor for wall system from Table 2
S IBS Score for other simplified construction solutions from Table 3

Calculation for IBS Score for a project

Building : Double Storey Terrace


2 storey
1) Construction Area
i) Ground Floor 72 m2 (for 1 unit)
ii) First Floor 72 m2 (for 1 unit)
ii) Roof area 72 m2 (for 1 unit)
iii) Total units 1
Total Construction Area 216 m2

2) Structural Systems :
Wall Load Bearing Precast Wall System
Roof Prefabricated steel roof truss

3) Wall System:
Wall area
i) Internal Precast wall panel 45.2 m / unit
ii)External Precast wall panel 71.3 m / unit
Total Wall Area 116.5 m

4) Other Simplified Construction Solutions


Beams 76% complies to MS1064 Part 10 : 2001
Columns 76% complies to MS1064 Part 10 : 2001
Wall 76% complies to MS1064 Part 10 : 2001
Slabs 76% complies to MS1064 Part 10 : 2001
Windows 76% complies to MS1054 Part 5 : 2001
Doors 76% complies to MS1054 Part 4 : 2001
a) For building more than 2 storeys
i)Repetition of floor to floor height 0%
ii)vertical repetition of structure layout 0%
b) For building 1 or 2 storeys
i)Horizontal repetition of structural layout 70%
Other Prefab components:-
Prefab Staircase 0%
ELEMENTS Area (m2) IBS Factor Coverage % IBS Score

Part 1 : Structural Systems (a) (b) (a) / (a) =(c) (b) x (c) x 50

1.1 Ground Floor


In-situ column & beams using reusable system 72 0.5 33% 8.33
formwork + In-situ concrete using reusable system
formwork
1.2 First Floor
In-situ column & beams using reusable system
formwork + In-situ concrete using reusable system 72 0.5 33% 8.33
formwork
1.6 Roof
Prefabricated roof truss 72 1.0 33% 16.67

Total Area 216 100%


Subtotal for Structural System (maximum 50 points) (A) 33.33

ELEMENTS Length (m) IBS Factor Coverage % IBS Score


Part 2 : Wall Systems (a) (b) (a) / (a) =(c) (b) x (c) x 20

Internal Wall
i)In-situ concrete with reusable system formwork 45.2 0.5 39% 3.88

External Wall
i)In-situ concrete with reusable system formwork 71.3 0.5 61% 6.12

Total Area 116.5 100%


Subtotal for Wall System (maximum 20 points) (B) 10.00
Part 3 : Other Simplified Construction Solutions

USAGE
% USAGE FOR
Elements UNIT THIS PROJECT
IBS SCORE
50%<X<75% 75%<X<100%

1.0 Utilisation of standardised


components based on MS 1064

a) Beams sizes complies to MS 1064 Part


10 : 2001 Nos 2 4 76% 4

b) Columns sizes complies to MS 1064 Part


10 : 2001 Nos 2 4 76% 4

c) Walls sizes complies to MS 1064 Part 10 :


2001 m 2 4 76% 4

d) Slabs sizes complies to MS 1064 Part 10 :


2001 m2 2 4 76% 4
e) Windows sizes complies to MS 1064 Part
10 : 2001 Nos 2 4 76% 4

2001 Nos 2 4 76% 4

2.0 Repetition of Structural Layout


a) For building more than 2 storeys

i) Repetition of floor to floor height Nos 1 2 N/A 0

ii) vertical repetition of structure layout Nos 1 2 N/A 0

iii) Horizontal repetition of structural layout Nos 1 2 N/A 0

b) For building 1 or 2 storeys

i)Horizontal repetition of structural layout Nos 3 6 70% 3

Subtotal for other simplified construction solution (maximum 30 points) ( C ) 27.0

TOTAL IBS Score (maximum 100 points) ( A + B + C ) 70.3


IBS SCORE for Cadangan Pembinaan

IBS Content Score for the project can be calculated using the following formula:

IBS Score for project = {IBS Score of building x Qst (building) / Qst(project)}

Construction IBS IBS


Item Building Coverage
Area (m 2) Score(building) Score(project)

1 Double Storey Terrace 216 1.000 70 70.33

Total 216 1.0 70.33

Therefore, the IBS score for the whole of the development project is 70.33