1.INTRODUCTION
This document defines the installation and wiring for the 092-100 Parallel To Series Changeover
Switch.

The parallel to series changeover switch provides a momentary 24V power source from two batteries
that are normally connected in Parallel. When the rocker switch on the front of the device is put in the
I position, the batteries are switched into a series configuration. The 12V power supply is
disconnected and the unit supplies 24V.

2.SYSTEM SPECIFICATION
Max Current Rating: 30A Continuous

3.INSTALLATION
To install the unit, complete the following steps:

1. Mount the unit in a suitable position using the four screw holes provided inside the case.
2. Connect the wire labelled BAT1- to the negative terminal of the first battery. DO NOT
CONNECT THE NEGATIVE TERMINAL OF THIS BATTERY TO COMMON GROUND.
3. Connect the wire labelled BAT1+ to the positive terminal of the first battery.
4. Connect the wire labelled BAT2- + E to the negative terminal of the second battery, and also
connect this wire to the common ground. This can be the chassis or the ground wires of all
electrical equipment.
5. Connect the wire labelled BAT2+ to the positive terminal of the second battery.
6. With the rocker switch in the 0 position, and no charging source connected, a voltage of
approximately 12V should be present at the wire labelled 12V from vehicle. A voltage of 0V
should be present on the wire labelled 24V out.
7. Switch the rocker switch to the I position. The relays in the device should operate. With the
switch still pressed, check that the wire labelled 12V from vehicle has a voltage of 0V and the
wire labelled 24V out has a voltage of approximately 24V.
8. Connect the wire labelled 12V from vehicle to the 12V charging source. This can be either a
12V battery charger or the trailer connector.
Connect the wire labelled 24V out to the 24V equipment that is to be powered by this unit.

4.OPERATION
When a 12V charging source is connected both batteries will be charged in parallel. Upon switching
the rocker switch to the I position, the battery charger will be disconnected and the 24V equipment
will operate.

LUDO McGURK SVE


UNIT 3 CROSSFIELD ROAD, HANDFORTH, CHESHIRE, SK9 3LN.
TEL: +44 1625 527 673 FAX: +44 1625 549 929
WEB: www.ludomcgurk.co.uk EMAIL: sales@ludomcgurk.co.uk
-2-
092-100 PARALLEL TO SERIES CHANGEOVER SWITCH

5.NOTES
Do not connect anything to the batteries other than this device. All 12V equipment should be
connected to the wire labelled 12V from vehicle. All 24V equipment should be connected to the wire
labelled 24V out. Failure to do this will result in improper operation of the unit.

6.WIRING DIAGRAM

WARRANTY
All products of Kussmaul Electronics Company Inc. & Ludo McGurk Transport Equipment
Ltd. are warranted to be free of defects of material or workmanship. Liability is limited to
repairing or replacing at our factory, without charge, any material or defects which become
apparent in normal use within 3 years from the date the equipment was shipped. Equipment
is to be returned; shipping charges prepaid and will be returned, after repair, shipping
charges paid.

Kussmaul Electronics Company, Inc. & Ludo McGurk Transport Equipment Ltd shall have no
liability for damages of any kind to associated equipment arising from the installation and /or
use of the Kussmaul Electronics Company, Inc. & Ludo McGurk Transport Equipment Ltd
products. The purchaser, by the acceptance of the equipment, assumes all liability for any
damages, which may result from its installation, use or misuse, by the purchaser, his or its
employees or others.

LUDO McGURK SVE


UNIT 3 CROSSFIELD ROAD, HANDFORTH, CHESHIRE, SK9 3LN.
TEL: +44 1625 527 673 FAX: +44 1625 549 929
WEB: www.ludomcgurk.co.uk EMAIL: sales@ludomcgurk.co.uk
-3-

S-ar putea să vă placă și