C330/C330M 09
TABLE 2 Maximum Dry Loose Bulk Density Requirements of 8.2 Splitting Tensile StrengthMake 152 by 305 mm [6 by
Lightweight Aggregates for Structural Concrete 12 in.] cylindrical test specimens in accordance with Practice
Maximum Dry Loose C192/C192M, cure, and test in accordance with Test Method
Bulk Density
Size Designation
kg/m3
C496/C496M.
[lb/ft3]
8.3 Density of Concrete (Test Method C567)Follow the
Fine aggregate 1120 [70]
Coarse aggregate 880 [55]
procedures in Test Method C567.
Combined fine and coarse aggregate 1040 [65] 8.4 Shrinkage of Concrete (Test Method C157/C157M)
Follow the procedures of Test Method C157/C157M with the
following exceptions:
TABLE 3 Compressive Strength and Splitting Tensile Strength
Requirements 8.4.1 Prepare
3
the concrete mixture using 335 kg of
cement/m [564 lb/yd3], admixture (if any), and with an air
Calculated Average 28-day Average 28-day
Equilibrium Splitting Tensile Compressive content of 6 6 1 %. Adjust the water content so as to produce
Density Strength, min, Strength, min, a slump of 50 to 100 mm [2 to 4 in.]. Thoroughly consolidate
max, kg/m3 MPa [psi] MPa [psi]
[lb/ft3]
the concrete in steel molds not smaller than 50 by 50 mm [2 by
All Lightweight Aggregate 2 in.] nor larger than 100 by 100 [4 by 4 in.] in cross section,
and long enough to provide a 250 mm [10 in.] gauge length.
1760 [110] 2.2 [320] 28 [4000]
1680 [105] 2.1 [300] 21 [3000]
The surface of the concrete shall be steel troweled.
1600 [100] 2.0 [290] 17 [2500] 8.4.2 CuringTo prevent evaporation of water from the
unhardened concrete, cover the specimen with a nonabsorptive,
Combination of Normal Weight and Lightweight Aggregates
nonreactive plate or sheet of tough, durable, impervious plastic
1840 [115] 2.3 [330] 28 [4000] or wet burlap. When wet burlap is used for covering, the burlap
1760 [110] 2.1 [310] 21 [3000] must be kept wet until the specimens are removed from the
1680 [105] 2.1 [300] 17 [2500]
molds (see Note 5). Remove specimens from the molds not less
than 20 nor more than 48 h after casting and store in a moist
room maintained at 23 6 2 C [73.5 6 3.5 F] with a relative
humidity of not less than 95 %. At the age of 7 days, remove
concrete, had the necessary resistance to freezing and thawing the specimens from the moist room, measure for length, and
to perform satisfactorily in its intended use. store in a curing cabinet maintained at 37.8 6 1.1 C [100 6
2 F] with a relative humidity of 32 6 2 %.
6. Sampling
6.1 Sample lightweight aggregates in accordance with Prac- NOTE 5Placing a sheet of plastic over the burlap will facilitate
keeping it wet.
tice D75. NOTE 6The air immediately above a saturated solution of magnesium
6.2 Reduce sample to test sizes in accordance with Practice chloride (MgCl2) at 37.8 C [100 F] is approximately 32 % relative
C702. humidity.
8.4.3 ReportAfter storage in the cabinet for 28 days,
7. Number of Tests remove each specimen and within 15 s, determine its change in
7.1 Tests on AggregatesOne representative sample is re- length to the nearest 0.01 % of the effective gauge length.
quired for each test for organic impurities, staining, loss on Report the change in length as the drying shrinkage of the
ignition, grading, bulk density, and clay lumps. specimen; report the average drying shrinkage of the speci-
mens as the drying shrinkage of the concrete.
7.2 Tests on ConcreteAt least three specimens are re-
quired for each of the following tests of concrete: compressive 8.5 Test for Popout MaterialsPrepare concrete specimens
strength, shrinkage, density, resistance to freezing and thawing, for the test for popout materials as described in method for
and presence of popout materials. At least eight concrete preparation of samples for shrinkage of concrete. Cure and
specimens are required for splitting tensile strength tests. autoclave the specimens in accordance with Test Method C151.
Visually inspect the autoclaved specimens for the number of
8. Test Methods popouts that have developed on the surface. Report the number
8.1 Compressive Strength (Test Method C39/C39M)Make of popouts per specimen.
test specimens in accordance with Practice C192/C192M and 8.6 Test for Freezing and Thawing Make freezing and
Practice C31/C31M. Unless otherwise specified, cure speci- thawing tests of concrete, when required, in accordance with
mens in accordance with Practice C192/C192M or Practice Test Method C666/C666M, with the following modification to
C31/C31M, until the time of test. When specified, an alterna- the section on Test Specimens and on Procedure. Unless
tive curing method is allowed. The alternative method shall be otherwise specified, remove the lightweight aggregate concrete
in accordance with Practice C192/C192M or the standard specimens from moist curing at an age of 14 days and allow to
curing procedure in Practice C31/C31M for the first 7 days, dry in air for another 14 days exposed to a relative humidity of
after which the specimens shall be removed from moist curing 50 6 5 % and a temperature of 23 6 2 C [73.5 6 3.5 F].
and stored at 23 6 2 C [73.5 6 3.5 F] with a relative Then submerge the specimens in water for 24 hours, prior to
humidity of 50 6 5 % until the time of test. the freezing and thawing test.
Copyright by ASTM Int'l (all rights reserved); Tue Apr 16 04:50:31 EDT 2013
3
Downloaded/printed by
William Phillips (none) pursuant to License Agreement. No further reproductions authorized.
C330/C330M 09
8.7 Grading (Test Method C136)Follow the procedures of 8.9 Clay Lumps and Friable Particles in Aggregate, shall be
Test Method C136, except that the mass of the test sample for in accordance with Test Method C142.
fine aggregate shall be in accordance with Table 4. The test
sample for coarse aggregate shall consist of 2830 cm3 [0.1 ft3] 8.10 Density FactorDetermine the Density (Specific
or more of the material used for the determination of bulk Gravity) Factor in accordance with ACI 211.2.
density. Mechanical sieving of aggregate shall be for 5 min-
utes. 9. Rejection
8.8 Bulk Density (Loose) (Test Method C29/C29M)The 9.1 Material that fails to conform to the requirements of this
aggregate shall be tested in an oven dry condition utilizing the specification shall be subject to rejection. The reason for
shoveling procedure. rejection shall be reported to the producer or supplier promptly
and in writing.
TABLE 4 Mass of Sieve Test Sample for Fine Lightweight
Aggregates 10. Certification
Nominal Bulk Density (Loose) of Aggregate Mass of Test
kg/m3 lb/ft3 Sample, g 10.1 When specified in the purchase order or contract, a
80240 515 50 producers or suppliers certification shall be furnished to the
240400 1525 100 purchaser that the material was sampled and tested in accor-
400560 2535 150
560720 3545 200
dance with this specification and has been found to meet the
720880 4555 250 requirements. When specified in the purchase order or contract,
880 1040 5565 300 a report of the test results shall be furnished.
10401120 6570 350
SUMMARY OF CHANGES
Committee C09 has identified the location of selected changes to this specification since the last issue,
C33005, that may impact the use of this specification. (Approved December 15, 2009)
(1) Revised 8.4.3. (2) Moved the tabular information from 5.2.1 into new Table 3
and renumbered subsequent tables.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/
COPYRIGHT/).
Copyright by ASTM Int'l (all rights reserved); Tue Apr 16 04:50:31 EDT 2013
4
Downloaded/printed by
William Phillips (none) pursuant to License Agreement. No further reproductions authorized.