GP/LP Common Features

Serial Interface (A)


Photoelectric
All devices are connectable with LP-S044 including PC, PLC, serial printer, barcode reader and dedicated connectors Sensors

can be connected with both RS232C and RS422 ports. (B)


Device must be set for the port in system setting for LP-S044, LP-S070. For details, refer to "GP user manual". Fiber
Optic
Use the dedicated communication cable for the each connected device. Sensors

(Refer to the "GP/LP Communication Cables" of page R-32)


(C)
For the method of wiring external devices like PLC, refer to "GP/LP communication manual". Door/Area
Sensors
Port NO. Pin (GP-S044, GP-S057, GP-S070) Pin (LP-S044, LP-S070)
RS232C 1 Not used Not used (D)
Proximity
2 RXD RXD Sensors
5
9 3 TXD TXD
4 (E)
8 4 DTR DTR Pressure
3 Sensors
7 5 SG SG
2
6 6 DSR DSR (F)
1 7 Not used Not used Rotary
Encoders
D-Sub 9-pin 8 Not used Not used
Male 9 Not used Not used (G)
Connectors/
RS422 1 TXD+ TXD+ Sockets

2 RXD+ RXD+
5 (H)
6 3 Not used Not used Temperature
4 Controllers
7 4 Not used Not used
3
8 5 SG SG
2 (I)
9 6 TXD- TXD- SSRs / Power
1 Controllers
7 RXD- RXD-
D-Sub 9-pin 8 Not used Not used (J)
Female 9 Not used Not used Counters

Power Wiring - F.G. (K)


+ Timers

For power supply, use the wire of which cross section is at least 0.75mm and
use the wire of which cross section is at least 1.25mm for grounding. (L)
Panel
Use crimp-on type terminal with at least 3mm of internal diameter and less than Meters

6mm of external diameter. (M)


Do not apply power before power line connection. Tacho /
Speed / Pulse
Check power polarity. Meters

Tighten the terminal screw with 0.5 to 0.8Nm torque. + - (N)


Ground resistance should be less than 100 and ground it separately. 24VDC
Display
Units

Battery Replacement
(O)
Sensor
Controllers
Please contact out distributor to replace battery.
It may cause an explosion or a fire when improper battery is used. (P)
Switching
Mode Power
Supplies

Caution During Use (Q)


Stepper Motors
Use communication cable after checking whether there is break, short. & Drivers
& Controllers
Please install power switch or circuit-breaker in order to cut power supply off.
(R)
Separate this unit from high voltage line, power line to avoid inductive noise. Graphic/
Logic
Do not use this product at below places. Panels

Place where there is severe vibration or impact (S)


Field
Place where dust exists, or corrosion causing environments. Network
Devices
Place where strong magnetic field or electric noise are generated
Place where is temperature/humidity is beyond the specification (T)
Software
Place where strong alkalis or vibration or impact
Place where there are direct ray of the sun
This product may be used in the following environments.
It shall be used indoor.
Altitude up to 2,000m
Pollution degree 2
Installation category

R-31