Sunteți pe pagina 1din 10

Engine and

generator
controllers
c o n t r o l l e r s

LOVATO Electric presents a complete line


of engine and generator controllers.

This range is complemented by a


comprehensive offer of electromechanical
and electronic products for measurement
and engine control.

AUTO
MAINS
FAILURE (AMF)
GEN-SET
CONTROLLERS

AA cc oo m
m pp ll ee tt ee rr aa nn gg ee oo ff pp rr oo dd uu cc tt ss

Motorised
Motor protection Rotary cam Current Changeover contactors Changeover switch switch
circuits breakers switches transformers disconnectors disconnectors
E n g i n e a n d g e n e r a t o r

ENGINE
PROTECTION
CONTROLLERS

STAND
ALONE
GEN-SET
CONTROLLERS

Earth leakage Automatic transfer Automatic battery


ralays switch controllers chargers

Digital metering Protection Push-buttons


instruments relays and selectors
Engine and
ENGINE PROTECTION CONTROLLERS STAND ALONE GEN

MODEL RGK30 RGK20 RGK40

Power key switch


Display 7 digit LCD 4 digit LED
Current control 1 phase
Analog sensor inputs

inputs n 4 4 6
Digital
outputs n 2 3 5
Expansion slots
PC set-up
Remote control
CANbus J1939

interface
Operator interface Operator interface Operator interface
- Two programming buttons - OFF-ON supply key selector switch - OFF-ON supply key selector switch
- 1 LED for engine status - Semiautomatic engine start button - Semiautomatic engine start button
- 1 LED for glow plug pre-heating - Two programming buttons - Two programming buttons
- 5 LEDs for alarm status. - 7 digit LCD (Hours, Hz, VBatt.) - 4 digit LED display (V, A, kVA,
Inputs/outputs (programmable functions) - 1 LED for engine status Hours, V batt., Hz)
- Digital inputs: 3 negative and 1 positive - 1 LED for glow plug pre-heating - 6 LEDs for measures/readings
(external start/stop by key switch) - 5 LEDs for alarm status. - 2 LEDs for Gen-Set status indication
- Digital outputs: 2 relay. Inputs/outputs (programmable functions) - 1 LED for glow plug pre-heating
- Frequency input - 8 LEDs for alarm status.
- Digital inputs: 3 negative and 1 positive Inputs/outputs (programmable functions)
- Digital outputs: 3 static - VAC input L1-L2-L3/N generator
- Inputs, outputs and alarms, all with - Digital inputs: 5 negative and 1 positive
programmable properties. - Digital outputs: 1 relay and 4 static
Additional features - Inputs, outputs and alarms, all with
- Quick set-up with PC software programmable properties.
(TTL/RS232 port). Additional features
- Quick set-up with PC software
(TTL/RS232 port).
generator cont
-SET CONTROLLERS AUTO MAINS FAILURE (AMF) GEN-SET

RGK50 RGAM10 RGAM20 RGAM12 - RGAM12RC


RGAM24 - RGAM24RC

Graphic LCD 4 alphanumeric character LED 4 alphanumeric character LED 3 digit LED
3 phase
Temperature - Pressure -
Fuel level
12 4 6 8
7 5 6 7


(Option board)
Operator interface Operator interface Operator interface Operator interface
- Voltage, current, power, power factor and - Voltage and frequency of mains and - Voltage and frequency of mains and - Voltage of mains and generator lines
frequency of mains and generator lines generator generator - Generator frequency
- Active and reactive energy - Battery voltage - Battery voltage - Battery voltage
- Battery voltage - Running hours - Engine speed - Running and maintenance hours
- Engine speed (stored in a non-volatile memory). - Maintenance hours (stored in a non-volatile memory).
- Oil pressure, engine temperature and - Alphanumeric display for alarm and (stored in a non-volatile memory) Inputs/outputs (programmable functions)
fuel level parameter texts - Running hours - VAC inputs: mains L1-L2/N-L3,
- Running and maintenance hours - Mains and generator supervision: (stored in a non-volatile memory). generator L1-L2/N
- Number of starts and percentage min-max voltage, min-max frequency, - Alphanumeric display for alarm and - 8 digital inputs; 7 relay outputs.
of successful starts phase sequence (for mains only) and parameter texts Additional features
- Event log of the last 255 events. voltage asymmetry (for mains only). - Mains and generator supervision: - Wide selection of functions to satisfy
Inputs/outputs (programmable functions) Inputs/outputs (programmable functions) min-max voltage, min-max frequency, particular application requirements
- VAC inputs: generator L1-L2-L3-N - VAC inputs: mains L1-L2/N-L3, phase sequence (for mains only) and - Quick commissioning with set-up
- Current inputs L1-L2-L3 generator L1-L2/N voltage asymmetry (for mains only). software and status supervision with
- 12 digital inputs; 7 relay outputs. - 4 digital inputs; 5 relay outputs Inputs/outputs (programmable functions) remote control software
- 2 slots for expansion boards: RS485 - Inputs, outputs and alarms, all with - VAC inputs: mains L1-L2/N-L3, - Modem support with Autocall function
interface, clock calendar, digital I/O, etc programmable properties. generator L1-L2/N for automatic email and SMS sending at
- Inputs, outputs and alarms, all with Additional features - 6 digital inputs; 6 relay outputs predefined events
programmable properties. - Wide selection of functions to satisfy - Inputs, outputs and alarms, all with - RS485 port for RGAMRC only.
Additional features particular application requirements programmable properties.
- 5-language support for alarms, events, - Quick set-up and commissioning with Additional features
parameters and help messages set-up software via RS232 port. - Wide selection of functions to satisfy
- All texts are user-customisable particular application requirements
- On-line help in case of alarm or during - Quick set-up and commissioning with
parameter setting set-up software via RS232 port
- Generator overload protection - Modem support with Autocall function
- Quick commissioning with set-up for automatic email and SMS sending at
software and status supervision with predefined events.
remote control software
- Modem support with Autocall function
for automatic email and SMS sending at
predefined events.
How to order

rollers Order code Description

ENGINE PROTECTION CONTROLLERS


RGK 30 12/24VDC, external start key switch
Qty
per pkg
no

1
Weight

[kg]

0.160

T CONTROLLERS RGK 20 12/24VDC, built-in power key switch


with TTL programming port
1 0.270
STAND ALONE GEN-SET CONTROLLERS
12/24VDC, built-in power key switch
RGK 40 1 0.400
with TTL programming port
RGK 50 12/24VDC, graphic LCD, with RS232 port 1 0.750
AUTO MAINS FAILURE (AMF) GEN-SET CONTROLLERS
12/24VDC, 4 alphanumeric character display,
RGAM 10 1 0.480
with RS232 port (for set-up only)
12/24VDC, 4 alphanumeric character display,
RGAM 20 1 0.460
with RS232 port
31 RGAM 12 12VDC, 3 digit LED display, with RS232 port 1 0.900
31 RGAM 24 24VDC, 3 digit LED display, with RS232 port 1 0.900
31 RGAM 12RC 12VDC, 3 digit LED display, with RS485 port 1 1.000
31 RGAM 24RC 24VDC, 3 digit LED display, with RS485 port 1 1.000
RGAM40 - RGAM41 - RGAM42 RGK60 RGAM 40 12/24VDC, graphic LCD, with RS232 port 1 0.830
12/24VDC, graphic LCD, with RTC ,
RGAM 41 1 0.840
RS232 and RS485 ports
12/24VDC, graphic LCD, with RTC ,
RGAM 42 1 0.840
Graphic LCD Graphic LCD RS232 and CANbus ports
RGK 60 12/24VDC, graphic LCD, with RS232 port 1 0.750
3 phase 3 phase
Temperature - Pressure - Temperature - Pressure - INTERFACE SOFTWARE
Fuel level Fuel level Remote control communication software for
31 RGAM SW RGAM 12 - RGAM 12RC - RGAM 24 1 0.246
8 12 RGAM 24RC units
7 7 RGK SW10 Set-up software for RGK 20 - RGK 40 - RGK 50 - 1 0.246
RGAM 10 - RGAM 20 - RGAM 4 - RGK 60 units
RGK SW20 Remote control software (includes RGK SW10) for
RGK 50 - RGAM 20 - RGAM 4 - RGK 60 units 1 0.400
ACCESSORIES
Option board (clock calendar, RS485 port
RGK X01
and 2 digital outputs) for RGK 50 - RGK 60 units 1 0.050
Option board (pick-up function, 2 digital outputs
RGK X21
(RGAM42 only) (Option board) and 4 digital inputs) for RGK 50 - RGK 60 units 1 0.090
Option board (4 relay outputs) for RGK 50 -
RGK X22 1 0.110
Operator interface Operator interface RGK 60 units
- Voltage, current, power, power factor - Voltage, current, power, power factor and Option board for CANbus J1939 interface
RGK X23 1 0.100
and frequency of mains and generator frequency of mains and generator lines for RGK 50 - RGK 60 units
lines - Active and reactive energy 51 C2 Cable for PC RS232 connection, 1.8m long 1 0.090
- Active and reactive energy - Battery voltage
- Battery voltage - Engine speed 51 C3 Cable for PC GSM Modem connection, 1.8m long 1 0.210
- Engine speed - Oil pressure, engine temperature and Cable for PC PX1/RS232 converter connection,
51 C4 1 0.147
- Oil pressure, engine temperature and fuel level 1.8m long
fuel level - Running and maintenance hours 51 C5 Cable for modem controller connection, 1.8m long 1 0.111
- Running and maintenance hours - Number of starts and percentage of
Cable for GSM modem controller connection,
- Number of starts and percentage of successful starts 51 C7 1 0.100
1.8m long
successful starts - Event log of the last 255 events.
- Event log of the last 255 events. Inputs/outputs (programmable functions) 51 C11 Cable for PC TTL/RS232 connection, 2.8m long 1 0.090
Inputs/outputs (programmable functions) - VAC inputs: mains L1-L2-L3-N,
RTC = Real Time Clock with backup battery.
- VAC inputs: mains L1-L2-L3-N, generator L1-L2-L3-N
generator L1-L2-L3-N - Current inputs L1-L2-L3
- Current inputs L1-L2-L3 - 12 digital inputs; 7 relay outputs.
- 8 digital inputs; 7 relay outputs - 2 slots for expansion boards:
- Inputs, outputs and alarms, all with RS485 interface, clock calendar,
programmable properties. digital I/O, etc.
- Inputs, outputs and alarms, all with
Dimensions [mm]
Additional features
- 5-language support for alarms, events programmable properties.
and parameters Additional features RGK 20
9 68
- Generator overload protection - 5-language support for alarms, events, 72 10 73.5
27
- Dummy load control parameters and help messages
- Quick commissioning with set-up - All texts are user-customisable
software and status supervision with - On-line help in case of alarm or during
72

68

remote control software parameter setting


- Modem support with Autocall function - Generator overload protection
for automatic email and SMS sending at - Quick commissioning with set-up
predefined events software and status supervision with
- Automatic generator test by means of remote control software RGK 30 91
programmable real time clock for - Modem support with Autocall function 96 16 81 9
RGAM 41 and RGAM 42 only for automatic email and SMS sending at
- CANbus - J1939 interface for RGAM 42 predefined events.
45
48
44

only.
Technical characteristics

ENGINE PROTECTION CONTROLLERS STAND ALONE GEN-SET CONTROLLERS


Model RGK30 RGK20 RGK40 RGK50 RGAM 10

Rated battery voltage 12/24VDC 12/24VDC 12/24VDC 12/24VDC 12/24VDC


Power supply range 933VDC 935VDC 935VDC 933VDC 935VDC
Mains voltage control L1-L2/N-L3
Generator voltage control L-N L1-L2-L3/N L1-L2-L3-N L1-L2/N
Rated voltage range 10227VAC 100415VAC 100480VAC 100415VAC
Current control L1 L1-L2-L3
Rated frequency 50/60Hz 50/60Hz 50/60/400Hz 50/60Hz
PT programming
Rated input current 5A 5A
Engine running pick-up input
TRMS voltage measure
TRMS current measure
Graphic backlit LCD, 4 alphanumeric
Display 7 digit LCD 4 digit LED 192x64 pixels character LED
LEDs n 7 7 17 8 16
Digital inputs n 4 4 6 12 4
Digital outputs n 2 (Relay) 3 (SSR) 1 (Relay) + 4 (SSR) 7 (Relay) 5 (Relay)
n 1 - 8A 250VAC AC1
8A 250VAC AC1 8A 250VAC AC1
Output rating 5A 30VDC DC1 1.2ADC (SSR) 5A 30VDC DC1
5A 30VDC DC1 8A 30VDC DC1
n 4 - 1.2ADC (SSR)
Engine running inputs D+ and AC D+ and AC D+ and AC D+ and AC D+ and AC
W or generator frequency
Engine speed input W W or generator frequency W or generator frequency or Pickup

Analog input: Level-Pressure-Temperature
I/O expansion
RS232 port (TTL) (TTL)
RS485 port
Remote control
CANbus interface
Event logging

RTC (Real Time Clock)


Parameters n 6 46 88 161 110
I/O functions n 31 53 67 25
Alarms n 6 13 25 45 18
User alarms n 1 1 8
Alarm property customisation
Texts for alarms, events and parameters
Languages n 5 GB - I - F - P - E 1 GB
Text customisation
Degree of protection IP41 IP41 IP54 IP54 IP54
Plug-in removable terminal connections
Remote control means: ASCII proprietary and Modbus RTU protocols, Option board. Remote control software with RS232, RS485, MODEM or
GSM modem management, On front. IP20 at rear. ETHERNET communication by means of TCP/IP protocol.
AUTOCALL function (SMS and email sending, etc). Events in volatile memory. Frequency only.

RGK 40 - RGAM 10 - RGAM 20 RGAM 12 - RGAM 12RC - RGAM 24 - RGAM 24RC - RGAM 40 - RGAM 41 - RGAM 42

138.5
23
144 16 78 8
91
6
96 12 82

27
138.5
144
90

91

96

14mm for RGK40


14mm for RGK40.
62mm for RGK40.
AUTO MAINS FAILURE (AMF) GEN-SET CONTROLLERS
RGAM 20 RGAM 12 RGAM 40 RGK 60
RGAM 12-RC RGAM 41
RGAM 24 RGAM 42
RGAM 24-RC
12/24VDC 12VDC or 24VDC 12/24VDC 12/24VDC
935VDC 916VDC or 1332VDC 935VDC 933VDC
L1-L2/N-L3 L1-L2/N-L3 L1-L2-L3-N L1-L2-L3-N
L1-L2/N L1-L2/N L1-L2-L3-N L1-L2-L3-N
100415VAC 100480VAC 100480VAC 100480VAC
L1-L2-L3 L1-L2-L3
50/60Hz 50/60Hz 50/60/400Hz 50/60/400Hz

5A 5A


4 alphanumeric Graphic backlit LCD, Graphic backlit LCD,
3 digit LED
character LED 128x64 pixels 192x64 pixels
19 16 9 10
6 8 8 12
6 (Relay) 7 (Relay) 7 (Relay) 7 (Relay)
8A 250VAC AC1 8A 250VAC AC1 8A 250VAC AC1 8A 250VAC AC1
8A 30VDC DC1 5A 30VDC DC1 8A 30VDC DC1 5A 30VDC DC1
D+ and AC D+ and AC D+ and AC D+ and AC
W or generator frequency W or generator frequency
W or generator frequency or Pickup or Pickup

(RGAMRC only) (RGAM 41 only)



(RGAM 42 only)


(RGAM 41 - RGAM 42 only)
163 80 177 182
50 8 67 71
31 17 43 47
4 4 4 8


5 GB - I - F - P - E 5 GB - I - F - P - E 5 GB - I - F - P - E
(only user alarms)
IP54 IP41 IP41 IP54

RGK 50 - RGK 60

6 181
11.6 106.4
196.5
106.5

91
Additional products

AUTOMATIC
BATTERY
CHARGERS

BCE
Order code Rated output current Rated output voltage DC Qty per pkg Wt
[A] [V] n [kg]
1 CHARGING LEVEL
31 BCE 0312 3 1 1.900
31 BCE 0612 6 12 1 4.750
31 BCE 1212 12 1 8.600

31 BCE 2V524 2.5 1 1.900


31 BCE 0524 5 24 1 4.925
31 BCE 1024 10 1 9.550

DIGITAL
METERING
INSTRUMENTS

DMK15 DMK15 R1 DMK25 DMK26


Order code Description Qty per pkg Wt
n [kg]
DMK 15 Voltmeter, ammeter and wattmeter, 220-240VAC supply (96x48mm) 1 0.332
Voltmeter, ammeter and wattmeter with programable output relay,
DMK 15 R1 1 0.350
220-240VAC supply (96x48mm)
DMK 25 Version for Gen-Set duty, 12-24VDC supply (96x96mm) 1 0.350
Version for Gen-Set duty with maximum current demand, voltage
DMK 26 1 0.350
and current imbalance, 12-24VDC supply (96x96mm)

AUTOMATIC
TRANSFER
SWITCH
CONTROLLERS
ATL10 ATL20 A240 ATL30 A240
Order code Description Qty per pkg Wt
n [kg]
ATL10 Version with RS232 port, 12/24/48VDC supply (96x96mm) 1 0.460
ATL20 A240 Version with RS232 port, 12-48VDC and 220-240VAC supply (144x144mm) 1 0.700
Version with RS232 and RS485 ports and real time clock, 12-48VDC and
ATL30 A240 1 0.700
220-240VAC supply (144x144mm)
INTERFACE SOFTWARE
Set-up software complete with 51 C2 cable for ATL 10, ATL 20 A240 and
ATL SW 1 0.246
ATL30 A240
ACCESSORIES FOR ATL10
31 PA96x96 Front IP54 protective cover 1 0.077
ACCESSORIES AND SPARE PARTS FOR ATL20 A240 AND ATL30 A240
51 C2 PC ATL connecting cable, 1.8m long 1 0.090
31 PACR Front IP54 protective cover 1 0.107
ACCESSORIES AND SPARE PARTS FOR ATL30 A240
51 C4 PC 4 PX1 converter connecting cable, 1.8m long 1 0.147
51 C5 ATL 30 A240 analog modem connecting cable, 1.8m long 1 0.111
51 C6 ATL 30 A240 4 PX1 converter connecting cable, 1.8m long 1 0.102
51 C9 PC analog modem connecting cable, 1.8m long 1 0.137
4 PX1 RS232/RS485 converter drive, opto-isolated, 220-240VAC 1 0.600
RS232/RS485 opto-isolated converter drive, 38,400 Baud rate maximum, automatic or manual TRANSMIT line supervision.
220-240VAC 10% (110-120VAC supply on request).

ATL10 ATL20 A240 ATL30 A240


Voltage control L1-L2-L3 L1-L2-L3-N L1-L2-L3-N
Serial interface With RS232 port (Modbus) With RS232 port (Modbus) With RS232 and RS485 opto-isolated
ports and real time clock (Modbus)
Display 1 2 2
Auxiliary voltage 12/24/48VDC 12-48VDC / 220-240VAC 12-48VDC / 220-240VAC
Rated voltage Ue 100-480VAC 100-690VAC 100-690VAC
inputs n 6 8 8
Digital:
outputs n 6 7 7
new

PLANET
Switch
Motor protection circuit
2009 breakers

Switch disconnectors
ON
I

OFF
0

Contactors

Motor protection relays

Electromechanical starters

Changeover switch disconnectors Control and signalling units

Limit, micro and foot


switches

Rotary cam switches

PLANET
Din

details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value.
The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and

In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for
7)
13(
5
3
1

CN25
.10

24V

50/60
Hz
A1

A2

tor
1

2
3

4
5

6
13

14
(7)

(8)

Modular contactors
contac
lar
Modu
2

Time relays

Protection relays

Level control relays


R1

0, 0,
0,

RH
E
LA
EATE
LK
R
G 0,
0,

0,0 t(sec

Earth leakage relays


0,0
T
I
TR SE
RE
1,
1 2 O reesn
ma
2, tx
0,
0,2 In(A In0,x
oreest
au tx1 reesn
ma
T Inx tx

TES In1x
OIN
T
C
In0,x

FU
oreets
au tx1

Motorised switch disconnectors


Inx
reesn
In1x
ma
In1x
ST
IN
n L
A
C
IE tx

In0,x
oreest
au tx1

Inx
reesn
ma In1x Inx
tx

In0,x
oreest
au tx1

Inx
In1x
In0,x
PLANET

Logic

electrical systems in order to avoid damages and safety hazards.


Metering instruments and
current transformers

Soft starters
Changeover contactors
MON

ENT
RUN

STOP
AC motor drives

Automatic power factor


controllers
D
RGE
Y CHA
TER
BAT
TIC ON
ER
OMA POW
AUT GE V
LO L
W
Y
G
R
O
A
BTE
CHAR

Automatic battery chargers


BLR
E
T
U
FO
BAY
SW
M NR
CT
E
BAO
N
Y
CT
ALAR PR
O
E
T
Y
TA
IN
BAIL
V

BC

7 8
6
9
5
100
FUSE 6,3A

4
BATTERY

30 GE
I CHAR
BATTERY
ALARM OUT
220-240V~
50-60Hz

+
_
POWER

_
-3V=
12
N
5-2.V=
24 L

Automatic transfer switch


AR
AL
TES

LINE
S
CIW
O
TL
E
C
R
AU I
M
L
FT
S
N
A
H S
TE

AT LINE L
H
L
L AU

controllers
H
L MA
L
L O
OF
OF
E
S
RE
O
W
A
R
D
TH
WI
I
TR
O
OF
O LO
N
P
T
O
A0 AE
T
W
U
O
E
7.D
R

A
LO
N
R
A0E
N
R
T
D
A
G8O

Current monitoring relays


W
A
R
D I
TR
E
G
Y
C
M
R
N
T
E9O
TH
S
A0
WI
N
2S
F
A0 LH
W
U
LTI4A
CEI

LS
N1W
A0P NR
O
G
A
I5E
H
S
Q

P
S
N
2W
A0 NR
O
G
A
LI6E
H
S
Q

B
V
A0LW
Y
R
G
E
1A
LT
O

V
H
G
A0 IY
R
O
G
E
B2TAL
H

N
T
F
A0 LH
W
U
C
L1SI3AEI

Programmable logic relays

Switching power supplies


AR
AL

Engine and generator controllers


TES

IW
SL
T
CE
O
C
R
AU I
L
M
FT
H
S
N
A L S
TE
L
AM L
RG H
AU
NE
LI
L
L
L MA
O
H
OF
OF
E
S
RE
O
W
A
R
D
TH
WI
I
TR
O
OF

Frequency meter
O NPO
LO
T
A0 UE
T
A
W
O
E
7.D
R

A
LO
N
R
A0E
N
R
T
D
A
G8O

W
A
R
D I
TR
E
Y
C
G
N
T
M
R
E9O
TH
S
A0
WI
N
2S
T
F
A0 EI
LH
W
U
LI4A
C

LS
N1W
A0P NR
A
O
G
5IE
H
S
Q

N
2W
P
S
A0 NR
O
G
A
LI6E
H
S
Q

LV
A0 LW
Y
R
G
1TA
BO E

G
B
V G
R
O
2A
HT
A0EL
H
IY

N
1S
FT
A0 LH
U
W
C
LI3AEI

www.LovatoElectric.com
LOVATO ELECTRIC S.P.A.
CONTROL SOLUTIONS FOR INDUSTRY
VIA DON E. MAZZA, 12 - 24020 GORLE (BERGAMO) ITALY
PD54 GB 11 08

Tel. +39 035 4282111 Fax +39 035 4282200


E-mail: info@LovatoElectric.com Sales Department: Tel. +39 035 4282354 - Fax +39 035 4282400
Digital metering instruments
LOVATO Electric offices in the world
United Kingdom Germany Spain Poland Czech Republic
LOVATO (UK) LTD DELTEC LOVATO GmbH LOVATO ELECTRIC S.L. LOVATO ELECTRIC SP. Z O.O. LOVATO S.R.O.
Tel. +44 1384 443377 Tel. +49 7237 1733 Tel. +34 938 454649 Tel. +48 71 7979010 Tel. +420 382 265482
www.Lovato.co.uk www.DeltecLovato.de www.LovatoElectric.es www.LovatoElectric.pl www.Lovato.cz
Latvia USA Canada Mexico Hong Kong - China
LOVATO-REZ LTD LOVATO ELECTRIC INC LOVATO ELECTRIC LOVATO ELECTRIC LOVATO ASIA (HK)
Tel. +371 7 381951 Tel. +1 757 545 4700 CORPORATION DE MEXICO, S.A. DE C.V. Tel. +852 27911616
www.Lovato.lv www.LovatoUsa.com Tel. +1 450 681 9200 Tel. +52 555 3415662 www.LovatoElectric.com
www.Lovato.ca www.LovatoElectric.com.mx

S-ar putea să vă placă și