Sunteți pe pagina 1din 48

Modular Channel

STAINLESS STEEL DRAINAGE PRODUCTS

Standard channel

programme for

all drainage

applications
history
BLCHER

Explanation of schematic
channel diagram
Explanation of schematic channel diagram
Each channel section contains a schematic
diagram detailing the range of channel lengths,
channel end height, outlet positions, outlet
BLCHER was established in 1965 in Vildbjerg,
height and flanged joint positions.
Denmark manufacturing stainless steel floor drains
The illustration below provides a key to the
for the local food processing industry.
precise definition of the figures used.
Today BLCHER, owned by Mapress Holding GmbH,
is a thriving international company employing over
300 staff worldwide.

0.50 metres
{ Channel length on one
side of outlet Initially BLCHER products were used where the
hygienic and corrosion resistance properties of
stainless steel were considered essential. Today
Min. depth of channel
at end
however, BLCHER products are installed within
almost any type of construction project.

Investments in modern production equipment and


highly efficient processes enable BLCHER to deliver
115 mm Position of cost effective drainage solutions suited to installations
Max. depth outlet/outlet box
with a design life expectancy of more than fifty years.
of channel at
outlet
The extensive product range includes:

Channel depth
BLCHER Domestic - Floor Drains
at outlet
BLCHER Industrial - Floor Drains
BLCHER Channel - Linear Floor Drainage
BLCHER Europipe - Drainage Pipes and Fittings
90 mm Flanged joint
Max. depth
of channel at
outlet

6.227 metres (total length)


6 metres (nominal length)
4 metres 2 metres

Flanged joint

Copyright by BLCHER
contents
BLCHER
.

C o n t e n t s

W O R L D W I D E
DRAINAGE SYSTEMS IN STAINLESS STEEL
ISO 9001 CERTIFIED

Introduction to BLCHER
Channel page... 4
Type 670 Channel without outlet box for
concrete, in-situ or tiled floors page... 6
Type 672 Channel without outlet box for
sheet vinyl floor covering page... 11
Type 671 Channel with outlet box for
concrete, in-situ or tiled floors page... 16
Type 671 Multichannel with outlet box for
concrete, in-situ or tiled floors page... 21
Type 673 Slot channel with outlet box for
concrete, in-situ or tiled floors page... 26
Options page... 31
Lower parts and water traps page... 33
Gratings page... 37
Accessories page... 41
Floor drainage methods page... 42
Technical specifications page... 44
Installation guide page... 46
Copyright by BLCHER page... 3
.

o v e r v i e w

Introduction to BLCHER Channel


Contained within this product catalogue are the various components that combine
to provide the BLCHER standard floor drainage channel programme. Developed on
the basis of 35 years experience in the production of stainless steel floor drainage
solutions BLCHER has incorporated the very best features from within the purpose
made channel programme to provide an easy to use, high performance off the shelf
solution.

The aim in developing BLCHER Channel has been to provide our customer with
easier selection, faster delivery and competitive prices combined with optimum
quality and corrosion resistance. Being produced largely from 2mm thick stainless
steel material the modular BLCHER Channel system also provides the highest
levels of stability and resistance to deformation when exposed to high loads.
In addition, the extremely smooth surface finish makes the channel system hygienic
and easy to clean.

Custom solutions
In the event you are unable to satisfy your specific application requirement from
within the standard BLCHER Channel programme please do not hesitate to contact
our technical services department for advice and support.

The right solution Floor covering


The following points should be considered when selecting a Concrete/tiles/in-situ (e.g. epoxy resin) or flexible sheet
channel system: (e.g. vinyl).
Membrane type
Water load Where required liquid or dry membrane application will
- continuous water flow determine the choice of lower part.
- intermittent discharge
- washdown Once the channel type has been determined choosing the
It is important to ensure the lower part and trap width, outlet dimension, length, depth, type of fixing, options,
arrangement has adequate flow capacity for the application. etc generates the unique product code.
Waste products
Where possible a grate should be chosen which permits Please refer to the explanation of the product code system on
pieces of waste to pass through for collection in a filter the inside of the back cover.
basket.
Loading
Example of product code definition
Can influence the choice of channel width as well as
determining the most appropriate grating for the
application.
Stainless steel grade
AISI 304 (material no. 1.4301) for standard applications or
AISI 316 L (material no. 1.4404) for aggressive / corrosive
applications.

page... 4 Copyright by BLCHER


how to use...
BLCHER

Type 670 Channel without outlet box for concrete, in-situ and tiled floors - page 6
Type overview Width:
Outlet:
147, 197, 297 and 397 mm inner frame dimension (B)
110 or 160 mm plain spigot
Length: 1-12 metres
Max depth
at outlet: 90 or 120 mm
Gratings: 8 different types
Typical
applications: Shower areas, kitchens, food & beverage production, chemical plants, abattoirs

Type 672 Channel without outlet box for sheet vinyl floor covering - page 11
Width: 147, 197, 297 and 397 mm inner frame dimension (B)
Outlet: 110 or 160 mm plain spigot
Length: 1-12 metres
Max depth
at outlet: 90 or 120 mm
Gratings: 8 different types
Typical
applications: Shower areas, kitchens, laboratories

Type 671* Channel with outlet box for concrete, in-situ or tiled floors - page 16
Width: 147 mm inner frame dimension (B)
Outlet: Outlet box with 160 outlet
Length: 1-11 metres
Max depth
at outlet: 90 or 115 mm
Grates: 7 different types
Typical
applications: Kitchens, food & beverage production, chemical plants, abattoirs

Type 671* Multichannel with outlet box for concrete, in-situ or tiled floors - page 21
Width: 77 mm inner frame dimension (B)
Outlet: Outlet box with 160 outlet
Length: 1-14 metres
Max depth
at outlet: 63, 78 or 93 mm
Grates: 6 different types
Typical
applications: Kitchens, shower areas, food & beverage production, chemical plants,
swimming pools, breakwaters

Type 673 Slot channel with outlet box for concrete, in-situ or tiled floors - page 26
Width: 20 mm aperture (B)
Outlet: Outlet box with 160 outlet
Length: 1-17 metres
Max depth
at outlet: 78, 93 or 108 mm
Grates: 6 different types (to outlet box only)
Typical
applications: Shower areas, beverage production, chemical plants, swimming pools, breakwaters

* The advantage of type 671 relative to type 670 is that with a narrow channel (77 or 147 mm inner width)
it is possible to achieve a higher outlet capacity via the 160 mm outlet box.

All channels with 160 mm outlet box can be combined with horizontal or vertical lower parts, with or
without a membrane flange. This detail also provides 60 mm height adjustment and full rodding access via the
removable water trap. See page 33.

Copyright by BLCHER page... 5


Type 670 .

Product code
definition
670 X X XXX-XX X X

Channel without outlet box


for concrete, in-situ or tiled floor
The channel is made in the following standard widths: Application areas:
147, 197, 297 and 397 mm internal frame dimensions For discharge directly into the channel
(B). For waste water with solids present
Where the channels water content is required as
A range of gratings is available to suit the varying a buffer
load and flow requirements - see page 37. Shower areas, kitchens, food & beverage
production, chemical plants, abattoirs

Channel width and outlet type selection


Select the required width and insert the appropriate letter from the
width type column into the product code.
Choose the relevant outlet type letter and insert into the product
code. Note that width type D is available with 110 (H) or 160
mm (K) outlet. 160 mm outlet can be combined with lower parts
- see page 33.
A
H1 dimensions are determined by the channel length selected see
B
following page.
C
26

670 X X XXX-XX X X Width type A B C Outlet type D H1 H3

H1
2

C 187 147 117 H 110 90/120 98


D 237 197 167 H 110 90/120 98
H3

K 160 90/120 184


E 337 297 267 K 160 90/120 184
D
F 437 397 367 K 160 90/120 184

An S is added after the


product code for orders in
AISI 316 L quality.

page... 6 Copyright by BLCHER


Type 670

Product code
definition
670 X X XXX-XX X X

Channel length
The adjacent table details the range of lengths and
outlet positions. Type 670 has two standard outlet 90
depths of 90 mm and 120 mm (see illustration).
The channel length can be up to:
6 metres with a depth of 90 mm
12 metres with a depth of 120 mm 120

670 X X XXX-XX X X

Length
Length and outlet position types are selected
from the table on pages 8-9
Outlet position

Options
These two digits indicate the choice of fixing type,
670 X X XXX-XX X X edge infill and protective strip - see page 31-32.

How to read the table


Find the required length in the row labelled
Nom. length (the overall length is found beside
the row labelled Total length)
Go to Schematic diagram and choose the
channel with the required outlet position.
(See explanation of schematic diagram on inner
side of the rear cover.)
Read off length type and outlet position type
from the column directly above the selected
channel
Insert the two type numbers selected into the
product code (as illustrated above)

Type no. for length

Type no. for outlet position

Nominal channel length


An S is added after the
product code for orders Overall channel length
in AISI 316 L quality.

Copyright by BLCHER page... 7


Type no. 670 Channel without outlet box for concrete or tiled floors (B=147 / B=197 / B=297 / B=397)

010 010 015 015 020 020 025 025 030 030 030 035 035 040 040 040 040 045
Length
type
Outlet 00 05 00 08 00 10 00 10 00 10 15 10 15 00 10 15 20 00
position type

Nom. length 1m 1,5 m 2m 2,5 m 3m 3,5 m 4m 4,5

Schematic
diagram
- outlet
position

120 mm

120

120
Maximum
channel depth

2,0 m
at outlet

70
1,5 m

1,5 m

1,5 m
75
75
75
80 1,0 m

1,0 m

1,0 m
1,0 m
1,0 m
0,75 m

80
80
80
80
85 0,5 m

82,5

90 mm
90

90
0,5 m 85 90

90

90

90
90

90

90
90

90
90
90

90

90
90

Maximum
82,5

channel depth
0,75 m
80

80

at outlet
80
1,0 m

1,0 m

4,0 m
75
75

75

75
1,5 m

1,5 m
1,5 m

4,5 m
70
70

70

70
2,0 m

2,0 m

2,0 m

2,0 m
65

65
65
2,5 m

2,5 m
2,5 m

60
60

3,0 m
3,0 m

Total length
1,04

1,04

1,53

1,54

2,04

2,04

2,54

2,53

3,02

3,04

3,02

3,54

3,53

4,02

4,02

4,03

4,04

4,51

in metres

B = 147 9 14 18 23 28 33 47 37 52
Water content

74
(litres)

B = 197 13 19 26 33 39 46 67 52

B = 297 20 31 41 51 61 72 106 82 116

B = 397 27 41 55 68 82 96 142 109 156

Copyright by BLCHER
m
60 90 75

15
4,51 3,0 m 1,5 m

045
65 90 70
2,5 m 2,0 m

20

92
59
42
045
4,54

123
70 120
5,0 m

00

80
57
5,02 050

170
126
60 90 70
3,0 m 2,0 m

20
050

5,02

5m

65
47

137
102
65 90 65
25
2,5 m 2,5 m
050

5,04

65 120
5,5 m
00

87
62
055

5,52

183
136
5,5 m

60 90 65
3,0 m 2,5 m
25

72
51
055

5,54

151
113
60 120
6,0 m
00
060

93
66
6,00

197
146
6m

60 90 60
3,0 m 3,0 m

78
56
30

6,00

164
123
060

80 F 120 90
4,0 m 3,0 m

86
30

7,00

257
191
121
070

7m

70 F 120 90
5,0 m 3,0 m
30
080

8,00

96
8m

284
212
135
80 F 120 F 80
4,0 m 4,0 m
40
080

8,00

60 F 120 90
6,0 m 3,0 m
30
090

8,98

70 F 120 F 80
5,0 m 4,0 m
40
090

9,00

312
232
147
105
9m

75 F 120 F 75
4,5 m 4,5 m
45
090

8,98

60 F 120 F 80
6,0 m 4,0 m
40
100

9,98

65 F 120 F 75
5,5 m 4,5 m
45
100

9,99

114

339
252
161
10 m

70 F 120 F 70
5,0 m 5,0 m
50
100

10,00

60 F 120 F 70
6,0 m 5,0 m
50
110

10,98

367
273
174
124
F F
11 m

65 120 65
5,5 m 5,5 m
55
110

11,00

60 F 120 F 60
6,0 m 6,0 m
60
120

11,96

394
293
187
133
12 m

- metal for life


Type 670

Accessories
The diagram below shows accessories and outlet
configurations achievable.

Filter basket Sand/Silt bucket Filter basket Removable water trap


780.002.000.05 780.002.000.00 780.107.110.05 502.052.110

Recommended
for shower
applications only
(alternative to
B=197,297,397 B=147,197 P trap)

Channel
grating
see page 37

110mm
160mm

562.002.000
811.xxx.160 811.xxx.110
760.002.xxx

Lower parts
with/without
membrane
flange and 763.002.xxx 760.002.xxx
water trap 525.090.160
see page 33 525.090.110
525.090.110

page... 10 Copyright by BLCHER


Type 672

Product code
definition
672 X X XXX-XX X X

Channel without outlet box


for sheet vinyl floor covering
The channel is made in the following standard widths: Application areas:
147, 197, 297 and 397 mm internal frame dimensions Where the channels water content is required as a
(B). buffer
For discharge directly into the channel
A range of gratings is available to suit the varying For waste water with solids present
load and flow requirements - see page 37. Vinyl thickness from 2 - 4 mm
Shower areas, kitchens, laboratories, doorways

Channel width and outlet type selection:


Select the required width and insert the appropriate letter from the
width type column into the product code.
Choose the relevant outlet type letter and insert into the product
code. Note that width type D is available with 110 (H) or 160
mm (K) outlet. 160 mm outlet can be combined with lower parts
- see page 33.
A
H1 dimensions are determined by the channel length selected see B
following page.
26

672 X X XXX-XX X X Width type A B C Outlet type D H1 H3


C

H1
1.5
C 235 147 155 H 110 90/120 98
D 285 197 205 H 110 90/120 98
K 160 90/120 184
H3

E 385 297 305 K 160 90/120 184


F 485 397 405 K 160 90/120 184 D

vinyl

Detail of channel installed


with vinyl

An S is added after the


product code for orders
in AISI 316 L quality.

Copyright by BLCHER page... 11


Type 672

Product code
definition
672 X X XXX-XX X X

Channel length
The adjacent table details the range of lengths and
outlet positions. Type 672 has two standard outlet
depths of 90 mm and 120 mm (see illustration). 90
The channel length can be up to:
6 metres with a depth of 90 mm
12 metres with a depth of 120 mm 120

672 X X XXX-XX X X

Length
Length and outlet position types are selected
from the table on pages 14-15
Outlet position

Options
These two digits indicate the choice of fixing type,
672 X X XXX-XX X X
edge infill and protective strip - see page 31-32.

How to read the table


Find the required length in the row labelled
Nom. length (the overall length is found beside
the row labelled Total length)
Go to Schematic diagram and choose the
channel with the required outlet position.
(See explanation of schematic diagram on inner
side of the rear cover.)
Read off length type and outlet position type
from the column directly above the selected
channel
Insert the two type numbers selected into the
product code (as illustrated above)

Type no. for length

Type no. for outlet position

Nominal channel length


An S is added after the
product code for orders in Overall channel length
AISI 316 L quality.

page... 12 Copyright by BLCHER


Type 672

Accessories
The diagram below shows accessories and outlet
configurations achievable

Sand/Silt bucket Filter basket Removable water trap


Filter basket 780.002.000.00 780.107.110.05
780.002.000.05 502.052.110

Recommended
for shower
applications
B=197,297,397 B=147,197 only (alternative
to P trap)

Channel
grating
see page 37

110mm
160mm

562.002.000
760.002.xxx 811.xxx.160 811.xxx.110

Lower parts
with/without
membrane
763.002.xxx
flange and 760.002.xxx
water trap 525.090.160
525.090.110
see page 33 525.090.110

Copyright by BLCHER page... 13


Type no. 672 Channel without outlet box for sheet vinyl floor covering (B=147 / B=197 / B=297 / B=397)

010 010 015 015 020 020 025 025 030 030 030 035 035 040 040 040 040 045
Length
type
Outlet 00 05 00 08 00 10 00 10 00 10 15 10 15 00 10 15 20 00
position type

Nom. length 1m 1,5 m 2m 2,5 m 3m 3,5 m 4m 4,5

Schematic
diagram
- outlet
position

120 mm

120

120
Maximum
channel depth

2,0 m
at outlet

70
1,5 m

1,5 m

1,5 m
75
75
75
80 1,0 m

1,0 m

1,0 m
1,0 m
1,0 m
0,75 m

80
80
80
80
85 0,5 m

82,5

90 mm
90

90
0,5 m 85 90

90

90

90
90

90

90
90

90
90
90

90

90
90

Maximum
channel depth
82,5

at outlet
0,75 m
80

80

80
1,0 m

1,0 m

4,0 m
75
75

75

75
1,5 m

1,5 m
1,5 m

4,5 m
70
70

70

70
2,0 m

2,0 m

2,0 m

2,0 m
65

65
65
2,5 m

2,5 m
2,5 m

60
60

3,0 m
3,0 m
1,08

1,08

1,57

1,58

2,08

2,08

2,58

2,57

3,06

3,08

3,06

3,58

3,57

4,06

4,06

4,07

4,08

4,55

Total length
in metres

9 14 18 23 28 33 47 37 52
B = 147
Water content

13 19 26 33 39 46 67 52 74
(litres)

B = 197

B = 297
20 31 41 51 61 72 106 82 116

B = 397 27 41 55 68 82 96 142 109 156

Copyright by BLCHER
m
60 90 75

15
4,55 3,0 m 1,5 m

045
65 90 70
2,5 m 2,0 m

20

92
59
42
4,58

045

123
70 120
5,0 m

80
57
00
5,06

170
126
050
60 90 70
3,0 m 2,0 m

20
5,06

5m
050

65
47

137
102
65 90 65
2,5 m 2,5 m
25
050

5,08

65 120
5,5 m

87
62
00

5,56
055

183
136
5,5 m

60 90 65
3,0 m 2,5 m

72
51
25

5,58

151
113
055

60 120
6,0 m
00

93
66
060

6,04

197
146
6m

60 90 60
3,0 m 3,0 m

78
56
30

6,04

164
123
060

80 F 120 90
4,0 m 3,0 m

86
7,04

257
191
121
30

7m
070

70 F 120 90
5,0 m 3,0 m
30

8,04
080

96
8m

284
212
135
80 F 120 F 80
4,0 m 4,0 m
40

8,04
080

60 F 120 90
6,0 m 3,0 m
30

9,02
090

70 F 120 F 80
5,0 m 4,0 m
40
090

9,04

312
232
147
105
9m

75 F 120 F 75
4,5 m 4,5 m
45
090

9,02

60 F 120 F 80
6,0 m 4,0 m
40

10,02
100

65 F 120 F 75
5,5 m 4,5 m
45

10,03
100

114

339
252
161
10 m

70 F 120 F 70
5,0 m 5,0 m
50
100

10,04

60 F 120 F 70
6,0 m 5,0 m
50
110

11,02

367
273
174
124
F F
11 m

65 120 65
5,5 m 5,5 m
55
110

11,04

60 F 120 F 60
6,0 m 6,0 m
60

12,00
120

394
293
187
133
12 m

- metal for life


Type 671 .

Product code
definition
671 C K XXX-XX X X

Channel with outlet box


for concrete, in-situ or tiled floor
The channel is made in a standard width of Application areas:
147 mm internal frame dimension (B). For discharge directly into the channel
For waste water with solids present
The benefit of the outlet box is that at 147 mm (B) it Where the channels water content is required as a
is possible to combine the channel with lower parts, buffer
removable water trap, P trap, filter basket and Kitchens, food & beverage production, chemical
sand/silt bucket. plants, abattoirs

A range of gratings is available to suit the varying


load and flow requirements
- see page 37.

Channel width
As the channel is supplied in only one standard width, Width type C
is used in the product code.

A
671 C K XXX-XX X X Width type A B C
B

C
C 187 147 117
26

Outlet box
The outlet box is supplied in one standard size and outlet dimension. B2
Therefore Outlet type K is used in the product code. Channel height B1
measurements H1 and H2 are determined by the channel length selected
- see page 17
H1

H2

671 C K XXX-XX X X Outlet type D B1 B2 H1 H2 H3

K 160 197 237 90 100 184


K 160 197 237 115 120 184
H3

D
An S is added after the
product code for orders in
AISI 316 L quality.

page... 16 Copyright by BLCHER


Type 671

Product code
definition
90
671 C K XXX-XX X X

Channel length
The adjacent table details the range of lengths and
outlet positions. Type 671 has two standard outlet 115
depths of 90 mm and 115 mm (see illustration).
The channel length can be up to:
6 metres with a depth of 90 mm
11 metres with a depth of 115 mm

671 C K XXX-XX X X

Length
Length and outlet position types are selected
from the table on pages 18-19
Outlet position

Options
These two digits indicate the choice of fixing type,
671 C K XXX-XX X X
edge infill and protective strip - see page 31-32.

How to read the table


Find the required length in the row labelled
Nom. length (the overall length is found beside
the row labelled Total length)
Go to Schematic diagram and choose the
channel with the required outlet position.
(See explanation of schematic diagram on inner
side of the rear cover.)
Read off length type and outlet position type
from the column directly above the selected
channel
Insert the two type numbers selected into the
product code (as illustrated above)

Type no. for length

Type no. for outlet position

Nominal channel length


An S is added after the
product code for orders Overall channel length
in AISI 316 L quality.

Copyright by BLCHER page... 17


type

Outlet

at outlet
at outlet

in metres
Length

- outlet

Maximum
Maximum
position
diagram
Schematic

(litres)
channel depth
channel depth

Total length
237
Nom. length

90 mm
115 mm
position type

Water content
80 90

9
1,0 m

00
1,237
75 90
1,5 m
00

14
1,727

2,0 m
70 90 1 m 1,5 m
00

2,237

18
2m

80 90 90 80
1,0 m 1,0 m
10

2,237
65 90
2,5 m
Type no. 671

2,737
00

23
75 90 90 80
2,5 m

2,727 1,5 m 1,0 m


10

60 90
3,0 m
00

3,217
70 90 90 80
2,0 m 1,0 m

28
10

3,237
3m

75 90 90 75
1,5 m 1,5 m
15

3,227
80 115
3,5 m
00

47
3,737
65 90 90 80
2,5 m 1,0 m
10

3,737
3,5 m

33

Copyright by BLCHER
70 90 90 75
2,0 m 1,5 m
15

3,727
010 015 020 020 025 025 030 030 030 035 035 035

75 115
4,0 m

52
00

4,227
60 90 90 80
3,0 m 1,0 m
10

4,237
4m

65 90 90 75
2,5 m 1,5 m

37
15

4,227
70 90 90 70
2,0 m 2,0 m
20

4,237
Channel with outlet box for concrete or tiled floors (B=147)

70 115
4,5 m
00

4,737

57
80 115 90 80
3,5 m 1,0 m
10

4,737
60 90 90 75
4,5 m

3,0 m 1,5 m
15

4,707

42
65 90 90 70
2,5 m 2,0 m
20
040 040 040 040 045 045 045 045

4,737
65 115
5,0 m

47
00

5,237
75 115 90 80
4,0 m 1,0 m
10

5,227

62
80 115 90 75
3,5 m 1,5 m
15

5m

5,227
60 70
3,0 m 2,0 m
90 90
20

5,217
050 050 050 050
47
65 65
5,237 2,5 m 2,5 m

25
90 90

60 115
5,717 5,5 m

00
70 115 90 80
5,737 4,5 m 1,0 m

10

66
75 115 90 75
5,717 4,0 m 1,5 m

15

5,5 m
80 115 90 70
5,737 3,5 m 2,0 m
20

60 90 90 65
5,717 3,0 m 2,5 m

51
25

65 F 115 90 80
6,237 5,0 m 1,0 m
10

70 F 115 90 75
6,227 4,5 m 1,5 m

71
15

75 F 115 90 70
6,227 4,0 m 2,0 m
20

6m

80 F 115 115 90
6,237 3,5 m 2,5 m
25

86
60 90 90 60
6,197 3m 3m

56
30

60 F 115 90 75
7,207 5,5 m 1,5 m
15
050 055 055 055 055 055 060 060 060 060 060 070

80
65 F 115 90 70
7,237 5,0 m 2,0 m
20

70 F 115 115
4,5 m 90 2,5 m
7,237

95
25

7m

75 F 115 90 60
7,207 4,0 m 3,0 m

80
30

80 F 115 115 F
7,237 3,5 m 80 3,5 m
35

95
60 F 115 90 90
8,217 5,5 m 2,5 m
25

90
65 F 115 90 60
8,217 5,0 m 3,0 m
30

8m

70 F 115 115 F
8,237 4,5 m 80 3,5 m
35

F F

105
75 115 115 75
4,0 m 4,0 m
40

8,217
070 070 070 070 080 080 080 080

60 F 115 115 F 80
5,5 m 3,5 m
9,217
35

65 F 115 115 F
5,0 m 75 4,0 m
40

9,227

114
9m

70 F 115 115 F 70
4,5 m 4,5 m
45

9,237
60 F 115 115 F
5,5 m 70 4,5 m
45

10,217

124
F F
10 m

65 115 115 65
10,237 5,0 m 5,0 m
50

60 F 115 115 F
11,197 5,5 m 60 5,5 m
55
090 090 090 100 100 110

133
11 m

- metal for life


Type 671

Accessories
The diagram below shows accessories and outlet
configurations achievable

Annular grating Ladder-shaped grating Ladder-shaped grating Cast grating Non-skid grating Mesh grating
697.200.200.20 697.125.200.20 697.150.200.20 697.250.200.20 697.025.200.20 696.223.194.20

Outlet box/
channel grating
ses page 37

Filter basket Sand/silt bucket


780.002.000.05 780.002.000.00

160mm

562.002.000
760.002.xxx 811.xxx.160

Lower parts
with/without
membrane flange
763.002.xxx
and water trap 760.002.xxx
ses page 33 525.090.160

525.090.110

page... 20 Copyright by BLCHER


Type 671 Multi

Product code
definition
671 B K XXX-XX X X

Multichannel with outlet box


for concrete, in-situ or tiled floor
Multichannel is made in a standard width of A range of gratings is available to suit the varying
77 mm internal frame dimension (B). load and flow requirements - see page 37.

The benefit of the outlet box is that at 77 mm (B) it Application areas:


is possible to combine the channel with lower parts, For discharge directly into the channel
removable water trap, P trap, filter basket and For waste water with solids present
sand/silt bucket. Low floor constructions the reduced channel
invert means that Multichannel can be installed
Furthermore lengths of up to 14 metres are achievable within restricted floor spaces
with the shallowest of invert levels making Kitchens, shower areas, food & beverage
Multichannel an excellent solution where depth production, chemical plants, swimming pools,
is restricted. breakwaters

Channel width
As the channel is supplied in only one standard width, Width type B is
used in the product code. A

B
671 B K XXX-XX X X Width type A B C
C

B 117 77 47
26

Outlet box
The outlet box is supplied in one standard size and outlet dimension.
Therefore Outlet type K is used in the product code. Channel height
B2
measurements H1 and H2 are determined by the channel length selected
B1
- see page 22

671 B K XXX-XX X X
H1

H2

Outlet type D B1 B2 H1 H2 H3

K 160 197 237 63 70 184


K 160 197 237 78 85 184
K 160 197 237 93 100 184
H3

An S is added after the


product code for orders
in AISI 316 L quality.
D

Copyright by BLCHER page... 21


Type 671 Multi

63

Product code
definition
671 B K XXX-XX X X

78
Channel length
The adjacent table details the range of lengths and
outlet positions. Type 671 Multichannel has three stan-
dard outlet depths of 63 mm, 78 mm and 93 mm (see
illustrations). The channel length can be up to:
4 metres with a depth of 63 mm 93
9 metres with a depth of 78 mm
14 metres with a depth of 93 mm

671 B K XXX-XX X X

Length
Length and outlet position types are selected
from the table on pages 24-25
Outlet position

Options
These two digits indicate the choice of fixing type,
671 B K XXX-XX X X edge infill and protective strip - see page 31-32.

How to read the table


Find the required length in the row labelled
Nom. length (the overall length is found beside
the row labelled Total length)
Go to Schematic diagram and choose the
channel with the required outlet position.
(See explanation of schematic diagram on inner
side of the rear cover.)
Read off length type and outlet position type
from the column directly above the selected
channel
Insert the two type numbers selected into the
product code (as illustrated above)

Type no. for length

Type no. for outlet position

Nominal channel length


An S is added after the
product code for orders in Overall channel length
AISI 316 L quality.

page... 22 Copyright by BLCHER


Type 671 Multi

Accessories
The diagram below shows accessories and outlet
configurations achievable

Annular grating Ladder-shaped grating Ladder-shaped grating Cast grating Non-skid grating Mesh grating
697.200.200.20 697.125.200.20 697.150.200.20 697.250.200.20 697.025.200.20 696.223.194.20

Outlet box/
channel grating
see page 37

Filter basket Sand/silt bucket


780.002.000.05 780.002.000.00

160mm

562.002.000
760.002.xxx 811.xxx.160

Lower parts
with/without
membrane flange 763.002.xxx
760.002.xxx
and water trap
525.090.160
see page 33
525.090.110

Copyright by BLCHER page... 23


type
Outlet

at outlet
at outlet
at outlet

in metres
Length

- outlet

Maximum
Maximum
Maximum
position
diagram

(litres)
Schematic

channel depth
channel depth
channel depth

Total length
Nom. length

63 mm
78 mm
93 mm
position type

237
57 63
1,0 m

Water content 2
1,237
54 63
1,5 m

4
1,727

1 1,5
51 63
2,237 2,0 m

5
57 63 63
1,0 m 2m
57 1,0 m
2,237
63 78
2,737 2,5 m

54 63 63
1,5 m 57 1,0 m
2,5 m

2,727
63 78
3,217 3,0 m

10 7 11
51 63 63
3,237 2,0 m 57 1,0 m
3m

8
54 63 63
3,217 1,5 m 54 1,5 m

57 78
3,737 3,5 m

12
63 78 63
2,5 m 57 1,0 m
Type no. 671 (Multi)

3,737
3,5 m

51 63 63
2,0 m 54 1,5 m

9
3,727
54 78
4,227 4,0 m

63 78 63
3,0 m 57 1,0 m

14
4,217
63 78 63
4m

4,227 2,5 m 54 1,5 m

51 63 63
2,0 m 51 2,0 m

11
4,237

Copyright by BLCHER
51 78
4,737 4,5 m

57 78 63
3,5 m 57 1,0 m

15
4,737
63 78 63
3,0 m 54 1,5 m
4,5 m

4,707
63 78 63
4,737 2,5 m 51 2,0 m

63 93
5,0 m

18 22
5,237
54 78 63
5,227 4,0 m 57 1,0 m

57 78 63
5,227 3,5 m 54 1,5 m

17
5m

63 78 63
5,217 3,0 m 51 2,0 m

63 78 78
5,237 2,5 m 63 2,5 m

F
63 93
5,717 5,5 m

20 24
51 78 63
5,737 4,5 m 57 1,0 m
Multichannel with outlet box for concrete or tiled floors (B=77)

54 78 63
5,717 4,0 m 54 1,5 m

18
5,5 m

57 78 63
5,737 3,5 m 51 2,0 m

63 78 78
5,717 3,0 m 63 2,5 m

63 F 93 63
5,0 m 57 1,0 m

21 25
6,237
51 F 78 63
6,227 4,5 m 54 1,5 m

19
54 78 63
6m

4,0 m 51 2,0 m
00 00 00 10 00 10 00 10 15 00 10 15 00 10 15 20 00 10 15 20 00 10 15 20 25 00 10 15 20 25 10 15 20

6,227
010 015 020 020 025 025 030 030 030 035 035 035 040 040 040 040 045 045 045 045 050 050 050 050 050 055 055 055 055 055 060 060 060
57 F 78 78

25
3,5 m 63 2,5 m
6,237

22
63 78 78
3,0 m 63 3,0 m
6,197
51 F 93
7,0 m

24
7,237
57 F 93 63
6,0 m 57 1,0 m
7,237
63 F 93 63
5,5 m 54 1,5 m

28
7,207
63 F 93 63
5,0 m 51 2,0 m
7,237

7m
51 F 78 78
4,5 m 63 2,5 m
7,237
54 F 78 78
4,0 m 63 3,0 m

25
7,207
57 F 78 78 F
3,5 m 57 3,5 m
7,237
51 F 93 63
7,0 m 57 1,0 m
8,237
54 F 93 63
6,5 m 54 1,5 m

31
8,217
57 F 93 63
6,0 m 51 2,0 m
8,237
63 F 93 93
5,5 m 78 2,5 m
8,217
8m

34
63 93 78
5,0 m 63 3,0 m
8,217
51 F 78 78 F
4,5 m 57 3,5 m
8,237

28
54 F 78 78 F
4,0 m 54 4,0 m
8,217
51 F 93 63
7,0 m 51 2,0 m

34
9,237
54 F 93 93
6,5 m 78 2,5 m
9,227
57 F 93 78
6,0 m 63 3,0 m
9,217

37
63 F F
9m

5,5 m 93 78 57 3,5 m
9,217
63 F 93 78 F
5,0 m 54 4,0 m
9,227
51 F 78 78 F
4,5 m 51 4,5 m

31
9,237
51 F 93 78
7,0 m 63 3,0 m
10,217
54 F 93 78 F
6,5 m 57 3,5 m
10,227

40
57 F 93 78 F
6,0 m 54 4,0 m
10,227
10 m

63 F 93 78 F
5,5 m 51 4,5 m
10,217
63 F 93 93 F
5,0 m 63 5,0 m

45
10,237
51 F 93 78 F
7,0 m 54 4,0 m
11,227

42
54 F 93 78 F
6,5 m 51 4,5 m
11,227
57 F 93 93 F
11 m

6,0 m 63 5,0 m
11,237

48
63 F 93 93 F
5,5 m 63 5,5 m
11,197
51 F 93 93 F
7,0 m 63 5,0 m
12,237
54 F 93 93 F
6,5 m 63 5,5 m

51
12,207
12 m

57 F 93 93 F
6,0 m 57 6,0 m
12,237
51 F 93 93 F
7,0 m 57 6,0 m
13,237
F F

54
54 93 93
6,5 m 54 6,5 m
13 m

13,217
51 F 93 93 F
7,0 m 51 7,0 m
30 00 10 15 20 25 30 35 10 15 20 25 30 35 40 20 25 30 35 40 45 30 35 40 45 50 40 45 50 55 50 55 60 60 65 70

57
14,237
060 060 070 070 070 070 070 070 070 080 080 080 080 080 080 080 090 090 090 090 090 090 100 100 100 100 100 110 110 110 110 120 120 120 130 130 140

14

- metal for life


Type 673

Product code
definition
673 A K XXX-XX X X

Slot channel with outlet box


for concrete, in-situ or tiled floors
Slot channel requires no grating but instead has a 20 Application areas:
mm aperture along the channel length, making it the As a breakwater to separate designated wet and
most cost effective solution in the modular range. dry areas
The profile shape has been developed to make it Washdown areas where wastewater contains low
robust, hygienic and most suitable for applications solid content
where wastewater discharges carry little or no solid Low floor constructions the reduced channel
matter. invert means that Slot channel can be installed
within restricted floor spaces
A range of gratings is available for the Outlet box Shower areas, beverage production, chemical
- see page 37. plants, swimming pools, breakwaters

A
Channel width
As the channel is supplied in only one standard width, Width type A is B

used in the product code.

673 A K XXX-XX X X Width type A B C

2
A 60 20 50

Outlet box
The outlet box is supplied in one standard size and outlet dimension. B2
Therefore Outlet type K is used in the product code. Channel height
B1
measurements H1 and H2 are determined by the channel length selected
- see page 27
H1

H2

673 A K XXX-XX X X Outlet type D B1 B2 H1 H2 H3

K 160 197 237 78 85 184


K 160 197 237 93 100 184
K 160 197 237 108 120 184
H3

An S is added after the


product code for orders in D
AISI 316 L quality.

page... 26 Copyright by BLCHER


Type 673

78

Product code
definition
673 A K XXX-XX X X
Channel length
The adjacent table details the 93
range of lengths and outlet positions.
Type 673 has three standard outlet depths of 78 mm,
93 mm and 108 mm (see illustrations). The channel
length can be up to:
6 metres with a depth of 78 mm 108

11 metres with a depth of 93 mm


17 metres with a depth of 108 mm

673 A K XXX-XX X X

Length
Length and outlet position types are selected
from the table on pages 28-29
Outlet position

Options
These two digits indicate the choice of fixing type,
673 A K XXX-XX X X
edge infill and protective strip - see page 31-32.

How to read the table


Find the required length in the row labelled
Nom. length (the overall length is found beside
the row labelled Total length)
Go to Schematic diagram and choose the
channel with the required outlet position.
(See explanation of schematic diagram on inner
side of the rear cover.)
Read off length type and outlet position type
from the column directly above the selected
channel
Insert the two type numbers selected into the
product code (as illustrated above)

Type no. for length

Type no. for outlet position

Nominal channel length


An S is added after the
product code for orders Overall channel length
in AISI 316 L quality.

Copyright by BLCHER page... 27


type
Outlet

at outlet
at outlet
at outlet

in metres
Length

- outlet

Maximum
Maximum
Maximum
position
diagram

(litres)
Schematic

channel depth
channel depth
channel depth

Total length
Nom. length

78 mm
93 mm
108 mm
position type

Water content
237
72 78
1.237 1,0 m
69 78

3 4
1.727 1,5 m
66 78
2.237 2,0 m

6
72 78 78
2.237 1,0 m 72 1,0 m

63 78
2.737 2,5 m

8
69 78 78
1,5 m 72 1,0 m
1 1,5 2 m 2,5 m
2.727
60 78
3.217 3,0 m
66 78 78
2,0 m 72 1,0 m

9
3.237
3m
Type no. 673

69 78 78
3.217 1,5 m 69 1,5 m

72 93
3,5 m

13
3.737
63 78 78
3.737 2,5 m 72 1,0 m

11
66
3,5 m

2,0 m 78 78 69 1,5 m
3.727
69 93
4,0 m

14
4.227
60 78 78
4.217 3,0 m 72 1,0 m

63 78 78
4m

2,5 m 69 1,5 m

12
4.227
66 78 78
4.237 2,0 m 66 2,0 m

66 93
4.737 4,5 m

16
72 93 78
4.737 3,5 m 72 1,0 m

60 78 78
4.707 3,0 m 69 1,5 m
4,5 m

14
63 78 78

Copyright by BLCHER
4.737 2,5 m 66 2,0 m

63 93
5.237 5,0 m
69 93 78
4,0 m 72 1,0 m

18
5.227
72 93 78
5.227 3,5 m 69 1,5 m
5m

60 78 78
5.217 3,0 m 66 2,0 m

16
63 78 78
5.237 2,5 m 63 2,5 m

60 93
5.717 5,5 m
Slot channel with outlet box for concrete or tiled floors

66 93 78
5.737 4,5 m 72 1,0 m

19
69 93 78
5.717 4,0 m 69 1,5 m

72
5,5 m

3,5 m 93 78 66 2,0 m
5.737
60 78 78
3,0 m 63 2,5 m

17
5.717
63 F 93 78
6.237 5,0 m 72 1,0 m

66 F 93 78
6.227 4,5 m 69 1,5 m
F

21
69 93 78
6.227 4,0 m 66 2,0 m
6m

72 F 93 78
6.237 3,5 m 63 2,5 m

60 78 78
6.197 3,0 m 60 3,0 m

69 F 108
7,0 m

19 28
7.207
60 F 93 78
7.207 5,5 m 69 1,5 m

24
63 F 93 78
7.237 5,0 m 66 2,0 m
010 015 020 020 025 025 030 030 030 035 035 035 040 040 040 040 045 045 045 045 050 050 050 050 050 055 055 055 055 055 060 060 060 060 060 070 070 070

66 F 93 93
7m

7.237 4,5 m 78 2,5 m

69 F 93 78
7.207 4,0 m 60 3,0 m
72 F 93 93 F
3,5 m 72 3,5 m
00 00 00 10 00 10 00 10 15 00 10 15 00 10 15 20 00 10 15 20 00 10 15 20 25 00 10 15 20 25 10 15 20 25 30 00 15 20 25 30 35

26 24 26
7.237
070 070 070
63 F 108
8,0 m

30
8.217
69 F 108 78
8.207 7,0 m 72 1,0 m

31
72 F 108 78
8.207 6,5 m 69 1,5 m

080 080 080


60 F 93 93
8.217 5,5 m 78 2,5 m

8m
63 F 93 78
5,0 m 60 3,0 m

29 27
8.217
66 F 93 93 F
8.237 4,5 m 72 3,5 m

29
69 F 93 93 F
8.217 4,0 m 69 4,0 m

63 F 108 78
9.217 8,0 m 72 1,0 m

66 F 108 78
7,5 m 69 1,5 m

35
9.207
69 F 108 78
9.207 7,0 m 66 2,0 m

72 F 108 93
6,5 m 78 2,5 m

37
9.217
9m
60 F 93 93 F
9.217 5,5 m 72 3,5 m

63 F 93 93 F
5,0 m 69 4,0 m

32
9.227
66 F 93 93 F
9.237 4,5 m 66 4,5 m

60 F 108 78
10.187 8,5 m 69 1,5 m
F

38
63 108 78
10.217 8,0 m 66 2,0 m

66 F 108 93
10.217 7,5 m 78 2,5 m

69 F 108 78
10.187 7,0 m 60 3,0 m
10 m

72 F 108 93 F
6,5 m 72 3,5 m

40 38 40
10.217
60 F 93 93 F
10.217 5,5 m 66 4,5 m
F F

36
63 93 93
10.237 5,0 m 63 5,0 m

60 F 108 93
11.197 8,5 m 78 2,5 m

63 F 108 78
11.197 8,0 m 60 3,0 m

66 F 108 93 F
11.217 7,5 m 72 3,5 m

69 F 108 93 F
7,0 m 69 4,0 m
11 m

11.197
72 F 108 93 F
11.217 6,5 m 66 4,5 m

60 F 93 93 F
5,5 m 60 5,5 m

43 41 43 45 43 39
11.197
60 F 108 93 F
12.197 8,5 m 72 3,5 m

63 F 108 93 F
8,0 m 69 4,0 m

46
12.207
66 F 108 93 F
12.217 7,5 m 66 4,5 m
12 m

69 F 108 93 F
12.207 7,0 m 63 5,0 m

72 F 108 108 F
6,5 m 63 5,5 m

48 50
12.197
60 F 108 93 F
13.177 8,5 m 66 4,5 m
F F

49
63 108 93
13.217 8,0 m 63 5,0 m

66 F 108 108 F
7,5 m 78 5,5 m
13 m

13.197
F F

54
72 108 108
13.197 6,5 m 72 6,5 m

60 F 108 108 F
14.177 8,5 m 78 5,5 m

66 F 108 108 F
7,5 m 72 6,5 m

57
14.197
14 m

69 F 108 108 F
14.177 7,0 m 69 7,0 m

60 F 108 108 F
15.177 8,5 m 72 6,5 m

63 F 108 108 F
8,0 m 69 7,0 m

60
15.187
15 m

66 F 108 108 F
15.197 7,5 m 66 7,5 m

60 F 108 108 F
16.177 8,5 m 66 7,5 m
F F

63
63 108 108
16.197 8,0 m 63 8,0 m

63 F 108 108 F
8,5 m 60 8,5 m

66
17.157
00 10 15 25 30 35 40 10 15 20 25 35 40 45 15 20 25 30 35 45 50 25 30 35 40 45 55 35 40 45 50 55 45 50 55 65 55 65 70 65 70 75 75 80 85
080 080 080 080 090 090 090 090 090 090 090 100 100 100 100 100 100 100 110 110 110 110 110 110 120 120 120 120 120 130 130 130 130 140 140 140 150 150 150 160 160 170

16 m 17

- metal for life


Type 673

Accessories
The diagram below shows accessories and outlet
configurations achievable

Annular grating Ladder-shaped grating Ladder-shaped grating Cast grating Non-skid grating Mesh grating
697.200.200.20 697.125.200.20 697.150.200.20 697.250.200.20 697.025.200.20 696.223.194.20

Outlet box
grating
see page 37

Filter basket Sand/silt bucket


780.002.000.05 780.002.000.00

160mm

562.002.000
760.002.xxx 811.xxx.160

Lower parts
763.002.xxx
with/without
760.002.xxx
membrane flange 525.090.160
and water trap
525.090.110
see page 33

page... 30 Copyright by BLCHER


options
BLCHER
.

Product code
definition
67X X X XXX-XX X X
Options
A range of options as follows is available for the standard channel system:

Fixing type
The connection between concrete and channel is particularly important for channels
exposed to heavy loadings and temperature differences. Two options are available to
protect the channel from the effect of these factors.

Stabiliser angle Anchor tang

Stabiliser angle (Fixing type A) Anchor tang (Fixing type B)


The stabiliser angle is longitudinally welded to Anchor tangs are positioned every 500 mm along
the channel wall thus supporting the channel the channel wall and should be bent out 90
and in contact with the concrete throughout the before casting. Anchor tangs are generally
channels length. The stabiliser angle is therefore suitable where the channel is not subjected to
recommended for use where the channel is excessive weight or thermal loadings (e.g.
subjected to heavy wheel loadings. Adjustable medium/light industrial). Adjustable legs can be
legs and anchor tangs can also be added to the added to the anchor tangs.
stabiliser angle.

Adjustable leg (product code 670.000.001) can be added to the stabiliser angle and anchor for use in
adjusting the channel to the required finished level before casting. Loose anchor tangs (product code
670.000.002) for installation on site can also be supplied for use with the stabiliser angle - see page 41.

67X X X XXX-XX X X
Fixing type Designation

A Stabiliser angle
B Anchor tang

An S is added after the


product code for orders
in AISI 316 L quality.

Copyright by BLCHER page... 31


.

o v e r v i e w

Product code
definition
Edge infill and protective strip
67X X X XXX-XX X X
Edge infill For optimum channel strength it is
important that the channel is properly embedded in
concrete. This is particularly notable with regards to
the underside of the channel edge profile. Whilst
this can be filled on site it is also possible to have
the filling carried out under factory conditions as
part of the production process. In addition to
providing greater rigidity to the channel, the edge
infill also prevents bacteria growth in any voids
remaining.

Protective strip The edge profile can be supplied


with a protective strip which adheres lightly and is
easily removed. This is to protect the edge profile
during installation leaving a perfect visible edge
once the installation is complete.

67X X X XXX-XX X X
Type Options

A None
B Edge infill
C Protective strip
D Edge infill and protective strip

An S is added after the


product code for orders in
AISI 316 L quality.

page... 32 Copyright by BLCHER


outlet variations
BLCHER
.

o v e r v i e w

Lower parts and water traps

All BLCHER channels with 160 mm outlet can be The capacity specified for the lower parts within the table
combined with either horizontal or vertical outlet lower below includes the removable water trap.
parts. This permits installation of a removable water trap
and filter basket or sand/silt bucket. In addition the lower Lower parts can be divided into three
part provides height adjustment of 60 mm making it easier groups:
to set the channel to the required finished floor level.
1. Lower parts without membrane flange.
Where connection to a damp proof membrane is required 2. Lower parts with flange for liquid membrane
there are also lower parts which are suitable for use with 3. Lower parts with flange for dry membrane
either liquid or dry membranes.

D2

Lower parts without membrane flange


Type number Outlet Capacity D1 D2 H1 H2
H2

760.002.075 75 mm 2.5 l/sec 75 190 65 195


H1

760.002.110 110 mm 2.5 l/sec 110 190 75 205

D1

Copyright by BLCHER page... 33


.

o v e r v i e w

D2

Lower parts without membrane flange

H1
Type number Outlet Capacity D1 D2 H1 H2 B L

H2
2.5

763.002.075 75 mm 2.8 l/sec 75 190 180 217 253 60

D1
763.002.110 110 mm 3.0 l/sec 110 190 165 217 155 70
L
B

D3
D2
Lower parts with flange for liquid membrane
Type number Outlet Capacity D1 D2 D3 H1 H2

H2
774.002.075 75 mm 2.5 l/sec 75 190 409 65 195
774.002.110 110 mm 2.5 l/sec 110 190 409 75 205

H1
D1

D3
D2

Type number Outlet Capacity D1 D2 D3 H1 H2 B L

769.002.075 75 mm 2.8 l/sec 75 190 409 180 217 253 60

H1
769.002.110 110 mm 3.0 l/sec 110 190 409 165 217 155 70
H2

2.5

D1
L
B
D3
D2
Lower parts with flange for dry membrane
Type number Outlet Capacity D1 D2 D3 H1 H2

775.002.075 75 mm 2.5 l/sec 75 190 409 65 195


H2

775.002.110 110 mm 2.5 l/sec 110 190 409 75 205


H1

D1
D3
D2

Type number Outlet Capacity D1 D2 D3 H1 H2 B L

771.002.075 75 mm 2.8 l/sec 75 190 409 180 217 253 60


H1

771.002.110 110 mm 3.0 l/sec 110 190 409 165 217 155 70
H2

2.5
D1

L
B

page... 34 Copyright by BLCHER


outlet variations
BLCHER
.

Dimensioned sketch for channel type 670 and 672 (B = 197, 297, 397)
with lower parts
The drawings below show the position of the outlet relative to the finished floor. The dimension H1 corresponds to
the channels depth (90 or 120 mm) at the outlet. Note that the channel can be adjusted 60 mm relative to the lower
part.

B B B B

H1
H1 H1 H1

248-308
267-327
278-338

288-348

300-360

300-360
200

210

222
222

110
75 110 75
160 160 160 160

760.002.075 S 760.002.110 S 763.002.075 S 763.002.110 S

Dimensioned sketch for channel types 671 and 673 with lower part.
The drawings below show the position of the outlet relative to the finished floor. The dimension H1 corresponds to
the height of the outlet box = 70, 85, 100 or 120 mm (depending on the channel depth selected). Note that the
outlet box/channel can be adjusted 60 mm relative to the lower part.
H1
H1

H1

H1

248-308
268-328
278-338

288-348

300-360
300-360
200

210

222

222

110
75

75
110
160 160 160
160
760.002.075 S 763.002.075 S 763.002.110 S
760.002.110 S

Copyright by BLCHER page... 35


.

o v e r v i e w

Removable water traps for lower parts


Type number Capacity* VL Suitable for

562.002.000 S 3.3 l/sec 52 mm 760/763/771/774/775.002.xxx


VL

* Capacity when used together with lower part with vertical outlet.
For capacities when used together with other types of lower part,
please contact BLCHER.

Extension pipes socketed one end


Type number D L

811.015.075 75 mm 150 mm
811.025.075 75 mm 250 mm
811.050.075 75 mm 500 mm
811.015.110 110 mm 150 mm
811.025.110 110 mm 250 mm
L

811.050.110 110 mm 500 mm


811.015.160 160 mm 150 mm
811.025.160 160 mm 250 mm
811.050.160 160 mm 500 mm
D

P-Trap
Type number D Capacity X1 X2 X3 VL
2.
5

525.090.075 S 75 mm 2.5 l/sec 093 mm 222 mm 189 mm 081 mm


525.090.110 S 110 mm 3.4 l/sec 132 mm 289 mm 249 mm 089 mm
VL

525.090.160 S 160 mm 7.5 l/sec 184 mm 388 mm 338 mm 105 mm


X3
X1

X2

page... 36 Copyright by BLCHER


gratings
BLCHER
.

Gratings for channels and outlet boxes

An extensive range of BLCHER channel gratings is available All gratings are 25 mm deep at the bearing point to
to suit varying load, hygiene and flow requirements. ensure a precise fit in the channel profile.

For definition of load classes - see page 40.

Gratings with associated loading classes

Shower grating
2 mm material thickness with holes 8 x 8 mm

Type number Width Length DIN (loading class)

697.015.075.99 074 mm 998 mm K 300 kg


697.015.150.99 144 mm 998 mm K 300 kg

An S is added after the product code for orders in AISI 316 L quality.

Copyright by BLCHER page... 37


.

o v e r v i e w

Non-skid grating
2 mm material thickness bent into profile with non-skid holes

Type number Width Length DIN (loading class)

697.026.075.99 073 mm 998 mm L 1500 kg


697.026.150.99 143 mm 998 mm L 1000 kg

697.026.200.20 193x193 mm for outlet box L 1200 kg

Ladder grating 25/5


25 x 5 mm spot welded flat steel with distance between bars of
19 mm. Grating reversible with non-skid surface to one side

Type number Width Length DIN (loading class)

697.125.075.50 075 mm 499 mm L 4500 kg


697.125.150.50 145 mm 499 mm L 5000 kg
697.125.200.50 195 mm 499 mm L 5000 kg
697.125.200.20 195x195 mm for outlet box L 7000 kg

Ladder grating 50/5


50 x 5 mm spot welded flat steel with distance between bars of
19 mm. Grating non-skid

Type number Width Length DIN (loading class)

697.150.150.50 145 mm 499 mm M 8400 kg


697.150.200.50 195 mm 499 mm M 8400 kg
697.150.300.50 295 mm 499 mm M 8400 kg
697.150.400.50 395 mm 499 mm M 8400 kg

697.150.200.20 195x195 mm for outlet box M 8400 kg

Annular grating
10 mm thick plate with welded support bars and 8 mm aperture

Type number Width Length DIN (loading class)

697.200.075.99* 075 mm 998 mm L 3500 kg


697.200.150.99* 145 mm 998 mm L 3500 kg
697.200.200.99* 195 mm 998 mm L 7000 kg

697.200.200.20* 195x195 mm for outlet box L 7000 kg

An S is added after the product code for orders in AISI 316 L quality.
* Available only in AISI 304 quality.
** Available only in AISI CF-8 (material no. 1.4308) quality.

page... 38 Copyright by BLCHER


gratings
BLCHER
.

Mesh grating
25 x 2 mm and 10 x 2 mm flat steel with non-skid surface
Aperture size 22 x 22 mm

Type number Width Length DIN (loading class)

696.223.074.99 074 mm 998 mm L 2000 kg


696.223.144.99 144 mm 998 mm L 1800 kg
696.223.194.99 194 mm 998 mm L 1350 kg
696.223.294.99 294 mm 998 mm L 1600 kg
696.223.394.99 394 mm 998 mm L 1250 kg

696.223.194.20 194x194 mm for outlet box L 1350 kg

Plain ladder grating 25/8


Fully welded flat bar with distance between bars of 18 mm

Type number Width Length DIN (loading class)

697.225.300.99* 294 mm 998 mm M 8400 kg


697.225.400.99* 394 mm 998 mm M 8400 kg

Cast grating
Fully cast with non-skid surface

Type number Width Length DIN (loading class)

697.250.075.50** 075 mm 499 mm M 8400 kg


697.250.150.50** 145 mm 499 mm L 6000 kg
697.250.200.50** 195 mm 499 mm M 8400 kg

697.250.200.20** 195x195 mm for outlet box M 8400 kg

Wegde grating
5.5x2.8mm wedge shaped bars welded to 12.7x3.3mm support
bars at 50mm centres
Type number Width Length DIN (loading class)

697.630.075.99 075 mm 999 mm - Pedestrian ONLY


697.630.150.99 145 mm 999 mm - Pedestrian ONLY
697.630.150.99 195 mm 999 mm - Pedestrian ONLY

Box grating
25x25x2mm thick box section fully welded.
Type number Width Length DIN (loading class)

697.235.150.99 145 mm 999 mm - approx 10000 kg


697.235.200.99 195 mm 999 mm - approx 5000 kg
697.235.300.99 294 mm 999 mm - approx 2000 kg
697.235.400.99 394 mm 999 mm - approx 1000 kg

Additional None Slip Tabs can be specified if required.

An S is added after the product code for orders in AISI 316 L quality.
* Available only in AISI 304 quality.
** Available only in AISI CF-8 (material no. 1.4308) quality.

Copyright by BLCHER page... 39


.

o v e r v i e w

Description of load classes:


Load classes. The gratings load class can be specified under Description of loading classes:
various standards and testing methods. The following are K(K300) The grating is loaded with 2/3 of 300 kg (200 kg)
relevant to BLCHERs specification of load classes: five times, with the pressure maintained for 5 min.
on the final occasion. The deflection is then
DIN 19 599: Gullies and manhole tops for use in buildings. measured.
Finally the grating is loaded with 300 kg.
The grating is tested with a piston, the size of which depends There is no deflection standard on this occasion
on the grating width (defined as the largest free opening in the but the grating must not break and should still
outlet/channel). The free opening is the diameter of the largest be removable.
circle which can exist between the grating supports.
As the grating is subjected to various piston sizes, it is not L(L1500) The grating is loaded with 2/3 of 1500 kg
always possible to compare the various widths (e.g. a grating (1000 kg) five times, with the pressure
with a width of 300 mm can be in a higher load class than a maintained for 5 min. on the final occasion.
grating with a width of 200 mm). The deflection is then measured.
Finally the grating is loaded with 1500 kg.
The maximum permitted deflection similarly depends on the There is no deflection standard on this occasion
free opening and is set at 2/500 of the area of the free but the grating must not break and should still
opening to a maximum of 2 mm. be removable.

The specified loading in kg for each grating corresponds to M(M12500)The grating is loaded with 2/3 of 12500 kg
the max. loading under the DIN standard. (8333 kg) five times, with the pressure
maintained for 5 min. on the final occasion.
The deflection is then measured.
Finally the grating is loaded with 12500 kg.
There is no deflection standard on this occasion
but the grating must not break and should still
The following classifications are designed to give a simplified be removable.
indication as to the suitability of the gratings in service:

Barefoot area e.g. shower areas, changing rooms

Pedestrian traffic e.g. kitchens, supermarkets

Pallet trucks, trolleys e.g. light industry

Delivery vans, lorries e.g. industry, factories

Fork-lift trucks e.g. heavy industry.

page... 40 Copyright by BLCHER


accessories
BLCHER

Optional extras
Adjustable legs can be added to either anchor tangs
or stabiliser angles and consist of a 150 mm long
8 mm threaded rod with two nuts used for height
adjustment and fixing the leg to the channel.
The threaded rod is fixed to a slotted foot plate for
fixing to the substructure and is designed to assist in
adjusting the channel to the required finished level
and to prevent the channel from floating during
casting in concrete.

Adjustable legs are available as individual extras.


Adjustable leg

Recommended number per channel:


Two per 1000 mm (min. four).

Anchor tangs are added to stabiliser angles in


particular where there are high thermal loads.

The anchor tangs are available as individual extras


and are easily fitted to the stabiliser angles slots.

Recommended number per channel:


Two per 500 mm (min. four).

Anchor tang

Type number Options

670.000.001* Adjustable leg


670.000.002* Anchor tang

* Available only in AISI 304 quality.

Copyright by BLCHER page... 41


.

o v e r v i e w

Floor drainage methods

Choice of channel or industrial drain Many discharge units and runoff water. It is possible to
To choose between a channel and a floor drain it is install a channel so that water does not cover the entire
necessary to consider the rooms use and design. floor and cause a safety hazard.
For example the number and location of discharge units, Large floor areas. Installing a channel in a large room
frequency of discharge, the volume of water, the size of allows the floor to be laid with less fall.
the room and the nature of the traffic in the room. Large quantities of surface water. The water content of a
The following factors indicate that channels should be large channel acts as a buffer and reduces slip hazards.
considered: Breakwater. A channel in a door opening will isolate
designated wet and dry areas.

Calculation of channel length


relative to room size
Where there are no special circumstances to be taken into As most floors with channels are laid to falls, account
account, the diagrams below can be used as a guide for must be taken at the planning stage to ensure the fall (A)
establishing the correct location and design of channels so does not exceed 1-2% (depending on floor type).
that a constant fall is achieved to the drainage channel.
CL = L-B
CL = L-B
CL = L-B

Room length = L A A A
L

- Room width = B

Channel length = CL
B B/2 B/2
B

page... 42 Copyright by BLCHER


capacity
BLCHER
.

Capacity
The channels capacity depends on channel type/size and For continuous flow, only the outlets flow rate should be
outlet type/dimensions. considered.

Where discharge is intermittent the channels water content The channels water content is given in the table under
can be taken into account. the individual channel lengths and is calculated for a water
level 5 mm below the channels top edge. See example
below.

Outlet capacity
For continuous water flow please refer to the approx. outlet capacities for lower parts and removable water traps
see pages 33-34

Copyright by BLCHER page... 43


.

o v e r v i e w

Technical Specifications
Material quality
All channels are made in either AISI 304 (material no. 1.4301) or AISI 316 L (material no. 1.4404) steel quality.
An S is added after the product code for orders in AISI 316 L quality.
All channels are chemically pickled and passivated to provide a clean hygienic surface finish.

Material thickness
Channels for concrete, in-situ or tiled floors: 2 mm, ensuring the channel can
be used where there are heavy loads. 2
Channels for sheet vinyl floorcovering: 1.5 mm vinyl covered floors are
not exposed to heavy loads.

Frame width 20

The frame width is 20 mm; outer height is 12 mm.

12
Grating support
26 mm shoulder depth ensures that 25 mm gratings do not protrude above the channel.
15 mm shoulder width ensures that there is adequate support for the various grating 15
types. Keeping this shoulder to a minimum is important for hygiene reasons to
prevent bacteria growth on the horizontal surface.

26
Cross-bars
8 x 20 mm flat bar placed 1/1000 mm in channels.
8 mm round bar steel is placed 1/500 mm in slot channels.
Cross-bars reinforce the channel and ensure that it is not pressed together
during embedding in concrete. Cross-bars also ensure that the grates are
not displaced longitudinally.

Channel widths
Gratings with widths of: Cross-bars
075 mm = total channel width 117 mm (A)
145 mm = total channel width 187 mm (A) A

195 mm = total channel width 237 mm (A)


295 mm = total channel width 337 mm (A)
395 mm = total channel width 437 mm (A)

48 mm is added to dimension (A) for vinyl channels.


60

20
Slot channels
The aperture is 20 mm permitting relatively small wheels
to run over the channel.
2

50

page... 44 Copyright by BLCHER


technical specifications
BLCHER
.

Longitudinal fall
In Multichannel and Slot channels the longitudinal fall is
0.5-0.6%; for all other channel types the fall is 1%.

Cross fall
Together with the longitudinal fall, cross fall ensures that
150 - 170
the waste water and solids flow to the outlet without leaving
deposits. The cross fall corresponds to an angle of 130 in
Slot channels and 150-170 for all other channel types.

Flanged joint
Channels with a total length exceeding 6 metres are made in
two or three sections which can be bolted together with
flanged joints. The flanges are 5 mm thick and finish flush
with all internal surfaces. One of the two mating flanges is
supplied with a 2 mm thick EPDM seal.

The flanges are tightened (30 Nm) together with the 8 mm


nuts and bolts supplied.

After jointing, it may be necessary to cut away any excess


seal inside the channel. This can be done with a sharp thin
Flanged joint
bladed knife. Approx. 2 mm of the seal will remain visible
after making a flanged joint. Each flange protrudes 34mm
from the channel bottom.

The flanged joint is labelled with an F in the channels


schematic diagram.
Max. 34 mm

Outlet
Channels are provided with either a plain spigot outlet or
an outlet box. The outlet fits either directly into the
interconnecting pipework or into an adjustable lower part
in which a removable water trap and filter basket can be
mounted.

Plain spigot Outlet box

Copyright by BLCHER page... 45


.

o v e r v i e w

Installation guide
Detail of flanged joint Bending out of anchor tangs

30 Nm

Connection of adjustable leg Connection of adjustable leg


to anchor tang to stabiliser angle

Connection of loose anchor tang to stabiliser angle

page... 46 Copyright by BLCHER


overview/user guide
BLCHER
.

u s e r g u i d e Product code system

Type
670 Std. channel drain without outlet box
Installation guide 671
672
Std. channel drain with outlet box
Std. channel drain without outlet box
for sheet vinyl floor covering
- tiled, in-situ and concrete floors 673 Slot channel drain

Width
Before installation. A Slot channel drain
If the channel is installed in a recess, B Grating width = 77mm
C Grating width = 147mm
it should be min. 100 mm wider and D Grating width = 197mm
50 mm deeper than the channels outer E Grating width = 297mm
F Grating width = 397mm
dimensions. Remember to take account
of anchor tangs or stabiliser angle. Length
010 etc. Total channel drain length
e.g. 010 = 1 metre and 100 = 10 metres
1. Infill underside of edge profile
(BLCHER offers this service as an Fixing type
A Stabiliser angle
option) B Anchor tang
2. Cast around the channel with
concrete ensuring the channel 6XX A A XXX- XX A A S Example
is properly supported to prevent 670AK100-40BC S (670 AK 100-40 BC S)
deformation
(None) Stainless steel AISI 304
3. Seal the interface between S Stainless steel AISI 316
channel and floor finish with a Options
suitable joint sealant A None
N.B.! Before embedding the channel B Edge infill
C Protective strip
anchor tangs must be bent out to 90. D Edge infill and protective strip

Outlet position
00, 10 etc. Distance from end to outlet
Installation guide - sheet vinyl floor covering e.g. 10 = 1 metre from end of channel drain

Outlet dimension
H= 110MM(DN100)
J= 148
K= 160(DN150)
L= 198

The channels product code is structured around


a system specifying the individual variables in
the code itself. The definition of the individual
elements in the product code is shown above.

1. Roll out the vinyl covering. 2. Fix the vinyl covering to the channel with the
clamping flange and accompanying screws.

N.B.! Before embedding the channel anchor tangs must


be bent out to 90.

The installation guide is included with the channel on delivery.

Copyright by BLCHER page... 47


BLCHER
Pugdalvej 1
7480 Vildbjerg
Denmark
Tel.: +45 99 92 08 00
Fax.: +45 99 92 08 30
mail@blucher.dk
www.blucher.com

Founded in 1965 BLCHER is recognised as one of Europes


leading manufacturers of stainless steel drainage systems.
Our products comply with the most stringent
requirements and specifications for professional users in the
food, beverage, chemical, shipyards and construction
industries worldwide.

S-ar putea să vă placă și