Documente Academic
Documente Profesional
Documente Cultură
Automation Portal
Segmento 1:
%FC2
"ACCIONES"
EN ENO
Segmento 2:
%FC1
"ESTADOS"
EN ENO
Totally Integrated
Automation Portal
Segmento 1:
%M0.0
"M0"
R
Segmento 2:
%I0.5
%M0.1 "A1_FINAL DE %M0.2
"M1" CARRERA" "M2"
S
%M0.1
"M1"
R
Segmento 3:
%M0.2
"M2"
R
Segmento 4:
%I0.4
%M0.3 "A0_FINAL DE %M0.4
"M3" CARRERA" "M4"
S
%M0.3
"M3"
R
Segmento 5:
%I0.7
%M0.4 "B1_FINAL DE %M0.5
"M4" CARRERA" "M5"
S
%M0.4
"M4"
R
Totally Integrated
Automation Portal
Segmento 6:
%I2.4
%M0.5 "D_DETECTOR %M0.6
"M5" PALETS" "M6"
S
%M0.5
"M5"
R
Segmento 7:
%I0.5
%M0.6 "A1_FINAL DE %M0.7
"M6" CARRERA" "M7"
S
%M0.6
"M6"
R
Segmento 8:
%M0.7
"M7"
R
Segmento 9:
%I0.4
%M1.0 "A0_FINAL DE %M1.1
"M10" CARRERA" "M11"
S
%M1.0
"M10"
R
Segmento 10:
%I0.6 %I2.4
%M1.1 "B0_FINAL DE "D_DETECTOR %M0.0
"M11" CARRERA" PALETS" "M0"
S
%M1.1
"M11"
R
Totally Integrated
Automation Portal
Segmento 1:
%Q0.0
%M0.1 "Q_CILINDRO
"M1" VERTICAL +"
%M0.2
"M2"
%M0.6
"M6"
%M0.7
"M7"
Segmento 2:
%Q0.1
%M0.4 "Q_CILINDRO
"M4" HORIZONTAL -"
Segmento 3:
%I0.6 %Q0.2
%M1.1 "B0_FINAL DE "Q_CILINDRO
"M11" CARRERA" HORIZONTAL +"
Segmento 4:
%Q1.0
%M0.2 "S_
"M2" SUCCIONADOR"
%M0.3
"M3"
%M0.4
"M4"
%M0.5
"M5"
%M0.6
"M6"
Totally Integrated
Automation Portal
Segmento 5:
%Q1.1
"C_CINTA
%M0.5 TRANSPORTADORA
"M5" "
%I2.4
%M1.1 %I3.0 "D_DETECTOR
"M11" "F2_DISYUNTOR" PALETS"
Segmento 6:
%M0.1 %Q2.2
"M1" "H1_VERDE"
S
Segmento 7:
%M0.0 %Q2.2
"M0" "H1_VERDE"
R
Segmento 8:
%M0.0 %Q2.4
"M0" "H1_ROJO"
Totally Integrated
Automation Portal
Segmento 1:
%M8190.0 %M0.0
"FirstScan" "M0"
S
%M0.1
"M1"
RESET_BF
11
Totally Integrated
Automation Portal
Segmento 1:
MOVE MOVE
EN ENO EN ENO
%MD7600 %ID0 %MD7604 %ID4
"Tag_1" IN OUT1 "Tag_2" "Tag_3" IN OUT1 "Tag_4"
Segmento 2:
MOVE MOVE
EN ENO EN ENO
%QD0 %MD7800 %QD4 %MD7804
"Tag_5" IN OUT1 "Tag_6" "Tag_7" IN OUT1 "Tag_8"
Segmento 3:
MOVE MOVE
EN ENO EN ENO
16#5447 IN %MW8000 16#4739 IN %MW8002
OUT1 "Tag_9" OUT1 "Tag_10"
Totally Integrated
Automation Portal
PLC_1 [CPU 1214C DC/DC/Rly] / Variables PLC / Tabla de variables estndar [80]
Variables PLC
Variables PLC
Nombre Tipo de datos Direccin Rema Accesible Escribible Visible en Supervisin Comentario
nencia desde desde HMI Engi
HMI/OPC HMI/OPC neering
UA UA
P_pulsador de marcha Bool %I0.2 False True True True
A0_FINAL DE CARRERA Bool %I0.4 False True True True
A1_FINAL DE CARRERA Bool %I0.5 False True True True
B0_FINAL DE CARRERA Bool %I0.6 False True True True
B1_FINAL DE CARRERA Bool %I0.7 False True True True
V_VENTOSA Bool %I2.0 False True True True
D_DETECTOR PALETS Bool %I2.4 False True True True
D_DETECTOR PIEZA Bool %I2.5 False True True True
Q_CILINDRO VERTICAL + Bool %Q0.0 False True True True
Q_CILINDRO HORIZONTAL - Bool %Q0.1 False True True True
Q_CILINDRO HORIZONTAL + Bool %Q0.2 False True True True
S_SUCCIONADOR Bool %Q1.0 False True True True
C_CINTA TRANSPORTADORA Bool %Q1.1 False True True True
System_Byte Byte %MB8190 False True True True
FirstScan Bool %M8190.0 False True True True
DiagStatusUpdate Bool %M8190.1 False True True True
AlwaysTRUE Bool %M8190.2 False True True True
AlwaysFALSE Bool %M8190.3 False True True True
Clock_Byte Byte %MB8191 False True True True
Clock_10Hz Bool %M8191.0 False True True True
Clock_5Hz Bool %M8191.1 False True True True
Clock_2.5Hz Bool %M8191.2 False True True True
Clock_2Hz Bool %M8191.3 False True True True
Clock_1.25Hz Bool %M8191.4 False True True True
Clock_1Hz Bool %M8191.5 False True True True
Clock_0.625Hz Bool %M8191.6 False True True True
Clock_0.5Hz Bool %M8191.7 False True True True
M0 Bool %M0.0 False True True True
M1 Bool %M0.1 False True True True
M2 Bool %M0.2 False True True True
M3 Bool %M0.3 False True True True
M4 Bool %M0.4 False True True True
M5 Bool %M0.5 False True True True
M6 Bool %M0.6 False True True True
M7 Bool %M0.7 False True True True
M10 Bool %M1.0 False True True True
M11 Bool %M1.1 False True True True
H1_VERDE Bool %Q2.2 False True True True
H1_ROJO Bool %Q2.4 False True True True
F2_DISYUNTOR Bool %I3.0 False True True True
Tag_1 DWord %MD7600 False True True True
Tag_2 DWord %ID0 False True True True
Tag_3 DWord %MD7604 False True True True
Tag_4 DWord %ID4 False True True True
Tag_5 DWord %QD0 False True True True
Tag_6 DWord %MD7800 False True True True
Tag_7 DWord %QD4 False True True True
Tag_8 DWord %MD7804 False True True True
Tag_9 Word %MW8000 False True True True
Tag_10 Word %MW8002 False True True True
Totally Integrated
Automation Portal
PLC_1 [CPU 1214C DC/DC/Rly] / Variables PLC / Tabla de variables estndar [80]
Constantes de usuario
Constantes de usuario
Nombre Tipo de datos Valor Comentario
Totally Integrated
Automation Portal