LEGEND (cont)
ISM Integrated Starter Module
LEGEND L Main Supply Power
AUX Auxiliary LVG Leaving
BRG Bearing N.O. Normally Open
C Contactor PRESS Pressure
CB Circuit Breaker REQMT Requirement
CCM Chiller Control Module TEMP Temperature
CCN Carrier Comfort Network TB Terminal Board
COMPR Compressor
COND Condenser Denotes Control Panel Terminal
CVC Chiller Visual Controller
DISCH Discharge Denotes Oil Pump Terminal
DL/DP Datalink or Dataport Denotes Power Panel Terminal
ENT Entering
EVAP Evaporator ** Denotes Motor Starter Panel Conn.
EXT External
FR Frame Denotes Component Terminal
GND Ground Wire Splice
G.V. Guide Vane Denotes Conductor
HGBP Hot Gas Bypass Male/Female Connector
HT EXCH Heat Exchanger Option Wiring
AUX Auxiliary FR Frame L Main Supply Power Denotes Oil Pump Terminal
C Contactor G Ground N.O. Normally Open Denotes Component Terminal
CB Circuit Breaker GRD Ground PRESS Pressure Denotes Power Panel Terminal
REQMT Requirement Wire Splice
CCM Chiller Control Module GVA Guide Vane Actuator
COMM Communication HGBP Hot Gas Bypass T Transformer * Denotes Mach. Control Panel Conn. Denotes Conductor Male/Female Connector
COMPR Compressor HT EXCH Heat Exchanger TB Terminal Board ** Denotes Motor Starter Panel Conn.
DISCH Discharge ISM Integrated Starter Module Option Wiring
103
LEGEND NOTES:
1. Power factor correction capacitors (when required) are connected ahead of all current
HPR High Pressure Relay transformers for proper calibration and sensing by the ISM and IQDP4130.
AUX Auxiliary 2. For metering option see Fig. 51.
C Contactor ISM Integrated Starter Module
CB Circuit Breaker L Main Supply Power
CT Current Transformer LL Control Power Supply
DS Disconnect Switch M Contactor
FU Fuse RES Resistor
G Ground S Contactor
TB Terminal Block
104
LEGEND
AM Ammeter
CT Current Transformer
ISM Integrated Starter Module
LL Control Power Supply
VFD Variable Frequency Drive
VM Voltmeter
Represents Twisted Wire
To Door
LEGEND
AM Ammeter
CT Current Transformer
ISM Integrated Starter Module
LL Control Power Supply
VFD Variable Frequency Drive
VM Voltmeter
Represents Twisted Wire
To Door
105
Fig. 52 Benshaw, Inc. Solid-State Unit Mounted Starter Wiring Schematic (Low Voltage)
106
LEGEND
AUX Auxiliary L Main Supply Power Wire Node Symbol PC Board Terminals
BR Bridge Rectifier LL Control Power Supply may have terminal block
CB Circuit Breaker M Contactor Twisted Pair
COND Condenser O/L Overload Reset Benshaw supplied
CPU Central Processing Unit PFCC Power Factor terminal block Twisted Shielded Pair
CVC Chiller Visual Controller Correction Capacitor
CT Current Transformer Terminal Strip Shield Wire
RLA Rated Load Amps
EVAP Evaporator SCR Silicone Controller Rectifier Power Connection Field Wiring
FU Fuse ST Shunt Trip
GND Ground TB Terminal Block
NOTES:
1 LED status with power applied and prior to run command. "ON"
"OFF"
Transformer T1 primary fuses FU1/FU2 value dependent on system voltage and model, per Chart 1.
2
Transformer connections per transformer nameplate connection diagram.
MOVs are used on power stack assemblies for system voltages of 200 through 460 vac (as shown).
3 Resistor/capacitor networks (DVDTs) are used on power stack assemblies in place of MOVs for a system
voltage of 575 vac (not shown).
K3 relay shown in deenergized state. K3 contact will close when power is supplied. K3 contact will open
4 on stop command or system fault.
5 CT1-CT3 are sized per Chart 2.
6 Optional.
Fig. 52 Benshaw, Inc. Solid-State Unit Mounted Starter Wiring Schematic (Low Voltage) (cont)
107
LEGEND
AUX Auxiliary
C Contactor
CB Circuit Breaker
COMM Communication
COND Condenser
CPT Control Power
Transformer
CR Control Relay
CT Current Transformer
DS Disconnect Switch
EVAP Evaporator
FU Fuse
G Ground
GFCT Ground Fault Current
108
Transformer
HPR Horsepower
ISM Integrated Starter
Module
L Main Power Supply
LL Control Power Supply
LVG Leaving
M Contactor
MTR Motor
PRESS Pressure
PT Power Transformer
ST Shunt Trip
STAT Status
TB Terminal Block
TRANS Transition
VFD Variable Frequency
Drive
VL Wire Label
Starter Vendor
Power Wiring
Starter Vendor
Control Wiring
Field Installed
Power Wiring
(supplied by others)
Field Installed
Control Wiring
(supplied by others)
Option Starter
Vendor Wiring
Twisted Pair Wiring
by Starter Vendor
Customer Terminal
Connection
109
GFCT Ground Fault Current
Transformer
HPR Horsepower
ISM Integrated Starter
Module
L Main Power Supply
LL Control Power Supply
LVG Leaving
M Contactor
MTR Motor
PRESS Pressure
PT Power Transformer
ST Shunt Trip
STAT Status
TB Terminal Block
TRANS Transition
VFD Variable Frequency
Drive
VL Wire Label
Starter Vendor
Power Wiring
Starter Vendor
Control Wiring
Field Installed
Power Wiring
(supplied by others)
Field Installed
Control Wiring
(supplied by others)
Option Starter
Vendor Wiring
Twisted Pair Wiring
by Starter Vendor
Customer Terminal
Connection
110
FU Fuse
GFCT Ground Fault Current
Transformer
HPR Horsepower
ISM Integrated Starter
Module
L Main Power Supply
LL Control Power Supply
MTR Motor
PRESS Pressure
PT Power Transformer
ST Shunt Trip
STAT Status
TB Terminal Block
TC Transition Clear
TRANS Transition
VFD Variable Frequency
Drive
VL Wire Label
Starter Vendor
Power Wiring
Starter Vendor
Control Wiring
Field Installed
Power Wiring
(supplied by others)
Field Installed
Control Wiring
(supplied by others)
Option Starter
Vendor Wiring
Twisted Pair Wiring
by Starter Vendor
Customer Terminal
Connection