Column Section
H1 152x152x30
Weld Properties
Size :10 mm Fillet Weld
Bolt Properties
Diameter : 16 mm
Achor Length : 300 mm
Compression not allowed in bolts
0.75 . . d 2
An =
4
0.75 16 2
=
4
= 150.796 mm2
k 1. A n. f u
Tr =
Ym2. 1000
.9 150.8 800
=
1.25 1000
= 86.861 kN
0.6 . An. f u
Vr =
Ym2. 1000
0.6 150.8 800
=
1.25 1000
= 57.907 kN
0.9 . An. f u
Cr =
1000
0.9 150.8 800
=
1000
= 108.576 kN
f yp
cMax = tp.
2
3 . . f ck. Ym0
3
300
= 30
2
3 30 1
3
= 67.082 mm
Project Number: Sheet:
Find Equilibruim
The actual number of Grid Point used for calculation is 1064
Project Number: Sheet:
Moment balancing
Sum Of Moments around X-axis = 4.7 kNm
Sum Of Moments around Y-axis = 2.7 kNm
StrainMax
FOS =
Strain
.0035
=
.00364
= 0.9615
Concrete Fails
Calculating Factors of Safety in Critical Bolt
Tension in Bolts
Critical Bolt Tension
Tr
FOS =
Tension
86859
=
86.403
= 1 005.278
Trc
FOS =
Tension
219.15
=
86.403
= 2.536
Shear in Bolts
Critical Bolt Shear
Vr
FOS =
Shear
57.906
=
4.6742
= 12.388
Shear Tension
f actor = +
Vr 1.4 . Tr
4.6742 5.0603
= +
57.906 1.4 86859
= 0.0808
Resistance
FOS =
Force
248.35
=
86.403
= 2.874
Welds
Since unit values are used for the length and size of the weld, the capacity
of this layout is given in kN/mm
Tu .
0.67 . 0.707 . Size
Ym2
Vr1 =
1000
420
0.67 0.707 10
1.25
=
1000
= 1.592 kN/mm
fy .
0.9 . 0.707 . Size
Ym2
Vr2 =
1000
300
0.9 0.707 10
1.25
=
1000
= 1.527 kN/mm
Resistance
FOS =
Force
1.5271
=
.79739
= 1.915