Sunteți pe pagina 1din 2

Project Piling works for Bukit Batok N4C18 to C21 BLK NO: 468A Date: 28/4/2017

Subject Pile ecentricity calculation Pile Group: G22 Rev: 0


Sheet: 1

PileGroup: G22 Column Ref: 18PC1


No of Pile: 1 nos Gk 2031 kN (inclusive of pilecap weight)
Pile Dia., h 700 mm Qk 300 kN
Capacity: 4000 kN (Structural capacity) Action Set 1 3192 kN (A1 = 1.35Gk+1.50Qk)
2750 kN (Working pile capacity) Action Set 2 2421 kN (A2 = 1.00Gk+1.30Qk)

fck 32 N/mm 2 (Concrete Grade C32/40)


fcd 16.5 N/mm 2 (fcd=ccfck/c),cl.3.1.6
2
fy 500 N/mm
fyd 435 N/mm 2 (fyd=fyk/s),
Cover 75 mm
d 550 mm
d/h 0.8
Area : 384845 mm2
Z: 33673946 mm3

Pile ECC : ex ey Resultant ed


59.5 89 107 182

Nd 3192 kN (Max.)
Md 581 kNm

Nd/h2fcd 0.40
3
Md/h fcd 0.10
2
ASfyd/h fcd 0.10 from Chart
Required As 1858 mm2
Provided 14H16
Provided As 2815 mm2 > Required As, OK!

Pilecap Enlargement Refer to Case 2 and attached sketch.

For Pile ECC , 75 < e 200mm, Refer to Standard amendment to pilecap due to pile eccentricity
Drawing NSB-DP-HABB-D1501-CS-603 Standard Details for Pile Eccentricity, Part 1
SB-DP-HABB-D1501-CS-604 Standard Details for Pile Eccentricity, Part 2
SB-DP-HABB-D1501-CS-605 Standard Details for Pile Eccentricity, Part 3
Project Piling works for Bukit Batok N4C18 to C21 BLK NO: 468A Date: 24/5/2017
Subject Pile ecentricity calculation Pile Group: G72 Rev: 0
Sheet: 1

PileGroup: G72
No of Pile: 1 nos
Pile Dia. 900 mm
Capacity: 6600 kN (Structural capacity)
4700 kN (Working pile capacity)

Column Ref: 18PC25


Gk 3484 kN (inclusive of pilecap weight)
Qk 400 kN
Action Set 1 5303 kN (A1 = 1.35Gk+1.50Qk)
Action Set 2 4004 kN (A2 = 1.00Gk+1.30Qk)

fck 32 N/mm 2 (Concrete Grade C32/40)


fcd 16.5 N/mm 2 (fcd=ccfck/c),cl.3.1.6

Area : 636173 mm2


Z: 71569408 mm3

Pile ECC : ex ey Resultant


95 20 97

Load Type P/A Pe/Z = P/A + Pe/Z Remark


2 2 2
N/mm N/mm N/mm
Structural 8.3 7.2 15.53 < 16.5N/mm2 OK!, within allowable

Working 6.3 5.4 11.73 < 16.5N/mm2 OK!, within allowable

Pilecap Enlargement Refer to Case 1b and attached sketch.

For Pile ECC , 75 < e 200mm, Refer to Standard amendment to pilecap due to pile eccentricity
Drawing NSB-DP-HABB-D1501-CS-603 Standard Details for Pile Eccentricity, Part 1
SB-DP-HABB-D1501-CS-604 Standard Details for Pile Eccentricity, Part 2
SB-DP-HABB-D1501-CS-605 Standard Details for Pile Eccentricity, Part 3