Technical data AUMA multi-turn actuators for open-close SAExC 07.1 SAExC 16.

1
duty with 3-phase AC motors AUMA NORM
Type Output Torque range1) Running torque2) Valve Valve stem Handwheel
speed for type of duty for type of duty attachment diameter
rpm
S2-15 min S2-30 min S2-15 min S2-30 min Standard Option for rising
min. max. max. max. max. EN ISO DIN valve stem3) reduc- approx.
50 Hz 60 Hz Nm Nm Nm Nm Nm 5210 3210 max. mm mm tion ratio kg5)
4 4.8 11 : 1
5.6 6.7 8:1
8 9.6 11 : 1
11 13 8:1 22
16 19 11 : 1
22 26 F 07 8:1
SAExC 07.1 32 38 10 30 20 12 6 G0 26 160 11 : 1
F 10
45 54 8:1
63 75 11 : 1
90 108 8:1 23
1254) 1504) 5.5 : 1
1804) 2164) 25 10 4:1
4 4.8 11 : 1
5.6 6.7 8:1
8 9.6 11 : 1
11 13 8:1 22
16 19 11 : 1
22 26 F 07 8:1
SAExC 07.5 20 60 40 24 12 G0 26 160 11 : 1
32 38 F 10
45 54 8:1
63 75 11 : 1
90 108 8:1 24
1254) 1504) 5.5 : 1
1804) 2164) 50 30 20 10 4:1
4 4.8 11 : 1
5.6 6.7 8:1
8 9.6 11 : 1
11 13 8:1 26
16 19 11 : 1
22 26 8:1
SAExC 10.1 32 38 40 120 90 48 24 F 10 G0 40 200 11 : 1
45 54 8:1 28
63 75 11 : 1
90 108 8:1
1254) 1504) 5.5 : 1 29
1804) 2164) 100 70 20 10 4:1
4 4.8 11 : 1
5.6 6.7 8:1
8 9.6 11 : 1 50
11 13 8:1
16 19 11 : 1
22 26 8:1 51
32 38 11 : 1
45 54 8:1 54
SAExC 14.1 63 75 100 250 180 100 50 F 14 G 1/2 57 315 11 : 1
90 108 8:1
1254) 1504) 5.5 : 1 55
1804) 2164) 200 140 80 40 4:1
4 4.8 11 : 1
5.6 6.7 8:1
8 9.6 175 90 11 : 1 52
11 13 8:1
16 19 11 : 1
22 26 150 80 8:1 53
SAExC 14.5 32 38 200 500 360 F 14 G 1/2 57 400 11 : 1
45 54 8:1
63 75 125 65 11 : 1
90 108 8:1 60
1254) 1504) 5.5 : 1
1804) 2164) 400 290 100 50 4:1
4 4.8 11 : 1
5.6 6.7 8:1
8 9.6 330 170 11 : 1
11 13 8:1 78
16 19 11 : 1
22 26 300 150 8:1
SAExC 16.1 32 38 400 1,000 710 F 16 G3 75 500 11 : 1
45 54 8:1 89
63 75 250 125 11 : 1
90 108 8:1
1254) 1504) 5.5 : 1 94
1804) 2164) 800 570 200 100 4:1

1) Tripping torque adjustable for both directions


2) Permissible average torque for the whole travel
3) For output drives type A and B1
4) Not self-locking
5) Weight for multi-turn actuator AUMA NORM with 3-phase AC motor, standard electrical connection, output drive type B1 and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Page 1 of 3
Issue 1.06
Y003.722/002/en
SAExC 07.1 SAExC 16.1 Technical data AUMA multi-turn actuators for open-close
AUMA NORM duty with 3-phase AC motors
General information
Multi-turn actuators AUMA NORM require electric controls. AUMA offers the actuator controls AUMA MATIC AMExC or
AUMATIC ACExC. These can also easily be mounted to the actuator at a later date.
Features and functions
Explosion protection Standard: II2G EEx de IIC T4
II2G c IIC T4
Options: II2G EEx d IIC T4
II2G c IIC T4
EC type examination certificate PTB 01 ATEX 1087
Type of duty 6) Standard: Short-time duty S2 - 15 min
Option: Short-time duty S2 - 30 min
Motors 3-ph AC asynchronous motor, type IM B9 according to IEC 34
Insulation class Standard: F, tropicalized
Option: H, tropicalized
Motor protection Standard: PTC thermistors (according DIN 44082) 7)
Option: Thermoswitches (NC) 8)
Self-locking Yes; for output speeds 4 to 90 rpm
Limit switching Counter gear mechanism for end positions CLOSED and OPEN
for 1 to 500 turns per stroke (optional for 1 to 5,000 turns per stroke)
Standard: Single switch (1 NC and 1 NO) for each end position
Options: Tandem switch (2 NC and 2 NO) for each end position, switches galvanically isolated
Triple switch (3 NC and 3 NO) for each end position, switches galvanically isolated
Intermediate position switch (DUO limit switching), available for any intermediate
position
Torque switching Torque switching for direction OPEN and CLOSE, infinitely adjustable
Standard: Single switch (1 NC and 1 NO) for each direction
Options: Tandem switch (2 NC and 2 NO) for each direction, switches galvanically isolated
Non-intrusive setting (option) Magnetic limit and torque transmitter MWG
(only possible in combination with actuator controls AUMATIC)
for 1 to 500 turns per stroke or
for 10 to 5,000 turns per stroke
Position feedback signal, Potentiometer or 0/4 20 mA (RWG)
analogue (options) For further details see separate data sheet
Torque feedback signal, analogue Only in combination with magnetic limit and torque transmitter MWG and actuator controls
(option) AUMATIC
Mech. position indicator Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
(option)
Running indication Blinker transmitter
Heater in switch compartment Standard: self-regulating PTC heater, 5 20 W, 110 250 V AC/DC
Options: 24 48 V AC/DC or 380 400 V AC
A resistance type heater (5 W, 24 V DC) is installed in the actuator in combination with the
actuator controls AUMA MATIC AMExC or AUMATIC ACExC.
Motor heater (option) SAExC 07.1 10.1: 12.5 W
SAExC 14.1 16.1: 25 W
Manual operation Manual drive for setting and emergency operation, handwheel does not rotate during electric
operation.
Option: Handwheel lockable
Electrical connection Standard: Ex-plug/socket connector with terminal board KP (screw type connection)
Options: Ex-plug-in terminal connection
Double Sealed
Threads for cable glands Standard: Metric threads
Options: Pg-threads, NPT-threads, G-threads
Terminal plan KMS TP210/001 (basic version)
Output drive types A, B1, B2, B3, B4 according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special output drives: AF, B3D, DD, ED, IB1, IB3

6) Based on 20 C ambient temperature and at an average load with running torque. The type of duty must not be exceeded
7) PTC thermistors require additionally a suitable tripping device in the controls
8) According to EN 60079-14, a thermal overload relay (e.g. motor protection switch) must be installed for explosion-proof actuators in addition to the thermoswitches
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Page 2 of 3

Issue 1.06

Y003.722/002/en
Technical data AUMA multi-turn actuators for open-close SAExC 07.1 SAExC 16.1
duty with 3-phase AC motors AUMA NORM
Service conditions
Enclosure protection according to Standard: IP 67
EN 60 529 9) Options: IP 68
For both enclosure protections (IP 67 and IP 68) the terminal compartment is additionally
sealed against the interior double sealed
Corrosion protection Standard: KN Suitable for installation in industrial units, in water or power plants
with a low pollutant concentration
Options: KS Suitable for installation in occasionally or permanently aggressive
atmosphere with a moderate pollutant concentration
(e.g. in wastewater treatment plants, chemical industry)
KX Suitable for installation in extremely aggressive atmosphere with high
humidity and high pollutant concentration
KX-G same as KX, however aluminium-free version (outer parts)
Finish coating Standard: two-component iron-mica combination
Colour Standard: grey (DB 702, similar to RAL 9007)
Option: Other colours are possible on request
Ambient temperature 10) Standard: 20 C to + 40 C
Options: 40 C to + 40 C (low temperature)
50 C to + 40 C (extreme low temperature)
Vibration resistance according to 2 g, for 10 to 200 Hz
EN 60068-2-6 Resistant to vibrations during start-up or for failures of the plant.
However, a fatigue strength may not be derived from this.
Valid for multi-turn actuators in version AUMA NORM (with Ex-plug socket connector with
terminal board KP, without actuator controls). Not valid in combination with gearboxes
Lifetime
Type Operating cycles (OPEN - CLOSE - OPEN)
with 30 turns/stroke
SAExC 07.1 SAExC 10.1 20,000
SAExC 14.1 SAExC 16.1 15,000

Other information
EC directives ATEX directive: (94/9/EC)
Electromagnetic Compatibility (EMC): (89/336/EEC)
Low Voltage Directive: (73/23/EEC)
Machinery Directive: (98/37/EC)
Reference documents Product description Electric multi-turn actuators SA
Information Electric actuators and valve gearboxes according to ATEX directive...
Dimension sheets SA(R)ExC
Electrical data sheets SAExC

9) For version in enclosure protection IP 68 higher corrosion protection KS or KX is strongly recommended.


10) Under certain conditions (special sizing) up to + 60 C possible. Version with RWG from 40 C to + 40 C (+ 60 C)
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Page 3 of 3
Issue 1.06
Y003.722/002/en