Siphon 100

Cryogenic Pumping System


(For High Pressure And
Liquid Cylinder Filling)
A c c o m p l i s h e d G o a ls o f t h e
S iphon 100 Pumping S y s tem

l Lower Cost Of Pumping High Pressure


And Liquid Cylinders
n Operational Costs
n Product Costs
l Improve Pumping Performance
l Increase Pumping System Reliability And
Lower Maintenance Cost
l Automate The Pumping Process

cdols/Siphon/Rev 082900 2
Inadequacies of
C u r r e n t P u m p ing S y s te m s

l Requires Long Cool-down Of Pump (15-20


Minutes)
l Automated Start-Up / Shutdown of
Pumping Process Not Possible Due To
System Inability
l Must Build Pressure To Maintain Prime At
Lower Tank Levels
l High Pump Maintenance Cost Due To High
Tank Operating Pressure
cdols/Siphon/Rev 082900 3
Inadequacies of
C u r r e n t P u m p ing S y s te m s

l Cannot Pump 10 - 50% Of Tank Contents


(Tankage Is Therefore Intentionally
Oversized).
l High Flash Loss In Liquid Cylinder Filling
(Due To Heat Addition From Pumping And
The Atmosphere).
l 250 PSIG Tankage Required Due To High
Operating Pressure.

cdols/Siphon/Rev 082900 4
C a u s e s O f P u m p ing
S y s tem Inadequacies

l Heat Addition From The Atmosphere


n Through The Tank Wall
n Through The External Piping

l Heat Addition From The Pumping Process


n Pump Cool-down
n Pump Blow-By

cdols/Siphon/Rev 082900 5
R e v ie w O f C u r r e n t C r y o g e n ic
P u m p ing S y s te m O p e r a tio n

l Pump Cool-down
n Open The Pump Feed (V-1)
And Pump Re-circulation
Valves (V-2)
n Liquid Flow Begins But May
Stop Before Total Pump Cool-
down
n Open Pressure Building Valve
(V-3) To Continue Pump Cool-
down Flow
l Results
n Heat Is Added To The Vapor
Space Of The Tank Each Time
The Pump is Cooled Down.
cdols/Siphon/Rev 082900 6
S iphon 100
S y s te m C o m p o n e n ts
Trap Is Below The Pump
And At Higher Pressure
l Tankage is Composite Insulated For So That Gas Always Rises
30 - 70% More Thermal Efficiency
Than Current Tankage.
l Incorporates An Extended Leg Design
For An Elevated Tank. (Natural Sub-
Cooling)
l Both The Suction And Return Line Are
Enclosed In A Vacuum Insulated
Chamber For Minimal Heat Gain
l Can Be Used With The Same Pump
As With Classical System Or With
New High Efficiency Pumps.

cdols/Siphon/Rev 082900 7
Pump Prime
And Operation

l Liquid Flow From Pump Suction To Re-


circulation Is Low (1/10 to 1/4 gpm)
l Heat Is Added to The Liquid At The Pump
System Due To:
n Un-insulated Liquid Suction Line
n Increased Liquid Pressure
n Blow-By
l Pump Cavitation Will Occur If Heat
Addition Is Greater Than Available Sub-
Cooling
l Sub-Cooling Is Increased By Additional
Head Pressure Or Leg Extensions.
l Increasing Amounts Of Pressure (Heat)
Are Added As The Liquid Level Drops
Until Pumping Stops Or The Tank Vents
cdols/Siphon/Rev 082900 8
S iphon 100
S y s te m O p e r a tio n
l Pump Cool Down
n Open The Pump Feed Valve (V-1) and Allow
Liquid Into The Line.
n Return Valve (V-2) Is Always Open (Except
To Isolate The Pump) So The Heated Liquid
Can Rise Back into The Tank To Start The
Siphon.
n Re-circulates Naturally At 4-5 GPM Which Is
Approximately 2 Times As Fast As The
Pump.
n Heat Is Absorbed By Large Mass Of Liquid At
The Bottom Of The Tank, Thereby Reducing
Pressure Rise As Compared To The
Classical System, Where Heat Gain Is Stored
In The Gas Phase.
n Results
n Pump Is Primed In 2 - 3 Minutes.
cdols/Siphon/Rev 082900 9
Pump Prime
And Operation
l Pump Suction Line Is Vacuum Insulated And Extended To
Reduce Heat Gain And Allow Natural Sub-Cooling.
l Liquid Flow In The Siphon Lines is 2 Times Greater Than The
Pump Requirements.
l The Excess Liquid Flow Pulls Blow-By Heat Away From The
Pump Inlet And Recycles The Heat In The Large Mass Of
Liquid In The Bottom Of The Tank.
l A Baffle Is Installed To Allow The Warm Return Liquid To Be
Fully Re-saturated Before Being Re-pumped.
l Pump Can Operate At Low Pressure (10 PSI) Without
Cavitation Until The Entire Tank Is Empty.

cdols/Siphon/Rev 082900 10
S ummary of
S iphon 100

Advantages Over The Classical System


l Pump Start-Up Simpler, Faster, And More
Reliable.
l Pumping Consistency And Stability Of The
Siphon 100 Allows Automatic Start-Up and Shut
Down Of The Pumping System.
l Pressure Building Not Required During
Pumping Cycle.
l Pump Maintenance Cycle Is Longer Due to
Operation At Lower Pressures.
cdols/Siphon/Rev 082900 11
S ummary of
S iphon 100

l Tank Can Be Pumped Completely Empty (Smaller


Tank Sizes Or Larger Working Inventories Are
Available.
l Warmer Return Liquid / Gas Returned To The Cold
Liquid In The Bottom Of The Tank Results In Heat
Distributed Throughout The Liquid. The Heat Is
Recycled, Not Stored In The Tank.
l Reduction Of Liquid Cylinder Flash Loss Due To
Substantially Low Operating Pressure (Less Heat).
l 175 PSI Tank Required Due To Lower Operating
Pressure.
cdols/Siphon/Rev 082900 12
S ummary of
S iphon 100

Advantages Over European Thermal


Siphon Design
l MVE Composite Insulation Provides
The Best Thermal Efficiency And
Lowest Maintenance Cost versus
Perlite And Super Insulation.
l The Siphon Suction and Return Line
Extends From The Bottom Of The
Tank Allowing For Removal Of The
Entire Tanks Contents.
l The Siphon 100 Has Higher Trap
Pressures And Greater Velocity
Providing Lower Heat Gain Per Unit
Of Mass.

cdols/Siphon/Rev 082900 13
C o m p e titiv e E v a luation

Siphon 100 European Theme Siphon

Tank MAWP 175 PSIG 175 PSIG & 250 PSIG


Insulation Composite Installation, low NER Perlite Insulation, standard NER
Patent YES NO
Baffle YES, no recirculation of warm product NO
Velocity /Feed Pressures 2:1 < .5:1
Pump Capacity For All Pump Types For some Horizontal Pumps/Special Two Stage Pumps
Liquid Feed Supply Standard from Siphon Optional Filling Line
Ability to Fill HP / Liq YES, from Siphon Tube No, Must Use Aux Liquid Withdrawal
Tank Sizing One Size Smaller Than Traditional Same as Conventional
PB System NONE Standard, needed to feed pump
Losses Reduced by 50%, for Liquid and HP Reduced slightly, designed for HP cylinders

cdols/Siphon/Rev 082900 14