Documente Academic
Documente Profesional
Documente Cultură
Description
This alarm is reported when the current supplied by the RF unit to the antenna device through feeder
or multi-wire cable is beyond the normal range.
Parameters
Minor The antenna device cannot work normally. In the case of an RET antenna,
the case of a TMA, the receive sensitivity decreases.
Warning The antenna device can work normally, but some secondary functions of t
System Actions
Procedure
1. Check the configuration of the ALD power supply switch on the M2000.
1. Run the MML command DSP ANTENNAPORT/DSP RETPORT to query
the status of the ALD power supply switch of the RF unit. Check whether
the status is correct according to the configuration plan.Y => The status of
the ALD power supply switch is correct. Go to step 2.
N => The status of the ALD power supply switch is incorrect. Go to sub-
step b.
2. Run the MML command MOD ANTENNAPORT/MOD RETPORT to modify
the ALD power supply switch configuration according to the configuration
plan.Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
2. Check the preset ALD current threshold of the RF unit on the M2000.
1. Run the MML command DSP ANTENNAPORT/DSP RETPORT/LST
ANTENNAPORT/LST RETPORT to query the ALD current threshold of
theRF unit. Consult the related ALD manual for the operating current of the
ALD. Check whether the ALD current threshold is correct.Y => The
threshold is correct. Go to step 3.
N => The threshold is incorrect. Go to sub-step b.
2. Run the MML command MOD ANTENNAPORT/MOD RETPORT to modify
the ALD current threshold of the RF unit according to the configuration
plan.Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
5. Check the installation of jumper between the feeder and the antenna device on site.
1. Check the installation of jumper between the feeder and the antenna
device.Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 6.