LAB REPORT

Unit ID Agitator/mixer drive


Component Lubricating oil
Current sample number 1700716
page 1 of 1

Machine type: Agitator/mixer drive


OELCHECK GmbH Postfach 1116 83094 Brannenburg Manufacturer: ABC
Oil brand name: BP Enersyn SG-XP 220
Oil quantity in system: 80 l
Example report
Analysis scope: Analysis-Kit 2

Diagnosis for the current laboratory values Sample Rating


The PQ index indicates a high content of magnetic ferrous particles. This is an indication of abnormal wear caused, for example, by
pitting, scuffing or contamination by other ferrous particles. The sample is heavily contaminated. Also, particles larger than 40 m can
be detected noticeably without a microscope. Your sample taking procedure may have influenced the analyzed values. I recommend
that you subject the oil to another trend analysis shortly. Change the oil if you are sure that the sample is representative of the oil refill.
Dipl.-Ing. Stefan Mitterer

Caution
ANALYSIS RESULTS Current sample Previous samples Bottle and Cap
LAB NUMBER 1700716 1700717
SAMPLE RATING
Date tested 13.03.2015 16.09.2013
Date of sample taken 09.03.2015 10.09.2013
Date of last oil change 22.02.2014 05.01.2013
Top-up since change l 0 10
Operating time since change M 11 8
Total operating time M 19 8
Oil changed no no
WEAR
Iron Fe mg/kg 98 140
Chrome Cr mg/kg 0 1
Tin Sn mg/kg 4 5 Infrared Spectrum
Aluminum Al mg/kg 1 1
Nickel Ni mg/kg 0 0
Copper Cu mg/kg 8 0
Lead Pb mg/kg 4 0
PQ index - 963 < 25
CONTAMINATION
Silicon Si mg/kg 5 0
Potassium K mg/kg 0 0
Sodium Na mg/kg 8 3
Water % < 0.10 < 0.10
OIL CONDITION
Viscosity at 40C mm/s 240.90 234.83
Viscosity at 100C mm/s 35.84 36.23
Viscosity index - 198 205
Oxidation A/cm 8 -
ADDITIVES
Calcium Ca mg/kg 38 5
Magnesium Mg mg/kg 1 0
Boron B mg/kg 0 1
Zinc Zn mg/kg 60 18
Phosphorus P mg/kg 766 631
Barium Ba mg/kg 7 1
Molybdenum Mo mg/kg 0 0
ADDITIONAL TESTS
AN / NN mgKOH/g 0.36 0.50

Description of standards and test methods: www.oelcheck.de