Improper operation of this product can be dangerous and could result in injury or death to
person and damage to the equipment. Every user or crew member must know the safety
provisions and comply with them at all times.
Do not operate this product until you verify that you are authorized to perform this work, and
that you have read and understood the operation manual. If the operation, maintenance or
repair technique used is not specifically recommended by Langh Tech, you must satisfy
yourself that it is safe for you and for others. You should also ensure that you are
authorized to perform this work, and that the product will not be damaged or become
unsafe by the operation, maintenance or repair procedures that you intend to use.
Langh Tech cannot anticipate every possible situation which may involve potential hazards.
The warnings in this publication and on the product are, therefore, not all inclusive.
Personal close attention to detail plus common sense operation of equipment are major
accident prevention measures.
You must not use this product in any manner different from that considered by this manual
without first satisfying yourself that you have considered all safety rules and precautions
applicable to the operation of the product in the location of use, including site-specific rules
and precaution applicable to the worksite.
All information, illustration and specification in this manual are based on the latest
information available at the time of publication. Langh Tech Oy Ab reserves the right to
change specifications, equipment, operating and maintenance instructions without prior
notice.
2 / 35
Table of contents
Backflush ............................................................................................................................ 12
Control system.................................................................................................................... 14
Attachments: ....................................................................................................................... 35
3 / 35
Type SWCU
Residual sludge depends on dirty scrubber water properties. Estimation is kg/ 1m3
scrubber water.(missing)
4 / 35
- Control system
5 / 35
6 / 35
Langh Tech Scrubber Water Treatment Purified water can be pumped overboard,
Unit purifies the process water used in a to the zero discharge tank or back to the
scrubber system. scrubber process. Remaining sulphates in
In order to avoid process residual the cleaned process water are neither
accumulation in the scrubber system toxic nor harmful but they increase the
extracted from the main circulation and therefore recycling of the process water
should be only part of the process water
led to the water treatment unit. Sludge
and harmful hazardous substances e.g. replacement. Purified water is pumped to
soot, metals, oil, hydrocarbons etc. are the purified water tank.
removed from the water by means of a Residual waste sludge is stored in the
filtration. The end product of the cleaning residue container. Full containers are
process is dry residual sludge and purified delivered ashore to an adequate reception
water. facility.
There are several ceramic tubes inside process. The dirty water tank 300TK1 is
the filter housings. Loop pump P300P2 used as a buffer tank for the water
pushes dirty water to circulation via the treatment unit. From time to time a portion
inner channels of the membranes. Dirt will of the scrubber process water is pumped
accumulate in the walls of the channels to the dirty water tank. The feed pump
and clean water will go through the 300P1 pumps from the dirty water tank to
the loop pump 300P2. Dirty water tank is
7 / 35
equipped with low- and high level alarm, Dirty and purified water
temperature sensor, sample cocks, vent
line and feed- and drain connections. The tanks
dirty water tank is also connected to the
Both tanks have continuous level
backflush tank via overflow line.
measuring and dirty water tank is also
equipped with 2 level switches for low and
Purified water can be reused as: high-level alarm indication. All control and
alarm level settings are adjustable from
-scrubber process water
the user interface.
-system backflush water
8 / 35
control system) until the water level is scrubber system) until water level is again
again below adjusted high level. above adjusted low limit.
Dirty water tank temperature is Purified water tank high level alarm signal
continuously monitored. If the water activates high level alarm and stops the
temperature is out of defined limits during purifier system until water level is again
system operation, low or high temperature below adjusted high limit.
alarm is tripped.
9 / 35
10 / 35
11 / 35
Backflush
loop; two purified water remote controlled purified tank and start backflush pump
Picture 7. Dirty scrubber process water on 4. Stop backflush pump 450P1 and wait
the left and purified water on the right. for pressure stabilization (duration
1000ms)
12 / 35
5. Close all backflush valves and open In normal working conditions bleed off
again valve V414 to purified tank water flow of 4-15l/min from the loop
system keeps backflush tank full at all the
time. Cleaner water is lighter and flows via
overflow line to the dirty water tank and
sludge will accumulate on the bottom of
the backflush tank. Depending on the
water quality in the bottom of the
backflush tank, 200-500 litres is drained
out to belt filter mixing tank in a 24h time.
Please see the belt filter section for further
information.
13 / 35
14 / 35
Picture 9. User interface on the control panel, main screen (WATER TREATMENT)
15 / 35
16 / 35
alarm message, including name and troubled device and also additional time
position of faulty sensor is activated. stamp and status information. Alarm
status can be active or inactive. All alarms
must be first acknowledged before
All system pumps and motors run-signals clearing (reset) from the alarm list is
and circuit breakers position-signals are possible. If the cause of a single alarm
connected to the PLC system. Tripped disappears, the alarm message will stay
motor circuit breaker or missing run-signal on the screen until acknowledgement and
during run command activation will reset is done.
activate fault alarm including tripped
device name and position information.
Following buttons are available:
17 / 35
18 / 35
- Switch loop backflush to manual mode - Stop the feed pump 300P1
19 / 35
- Drain the loop by opening valves - Run the loop until the loop water
V456;V455;V307;V417;V704;V502;V506; temperature will exceed 75C
V507;V509 to mixing tank 500TK1
- Stop the sludge pump 500P1 - Stop the loop pump 300P2
- Add 6-7l of Ultrasil 115 to cleaning water - Fill cleaning water tank with 50-60C
- Run the loop approx..15 minutes and - Close the valves V307;V455;V456;V417
then carefully open V417 approx. 30% - Start feed pump 300P1
- Adjust V704 at the same time so that - Start loop pump 300P2
loop suction side pressure stays close to
- Carefully open V417 approx. 30%
1bar
20 / 35
- Adjust V704 so that loop suction - Adjust V704 so that the loop pump
pressure is close to 1bar 300P2 suction side pressure will be close
to 1bar
- Rinse the system 10 minutes
- Add 6-7l of Ultrasil 73/75 to cleaning
water tank 700TK1
- Stop the loop pump 300P2
- Run the loop arp.15 minutes and then
- Stop the feed pump 300P1 carefully open V417 approx. 30%
- Drain the loop by opening valves - Adjust V704 at the same time so that
V456;V455;V307;V417;V704;V502;V506; loop suction side pressure stays close to
V507;V509 to mixing tank 500TK1 1bar
- Start sludge pump 500P1 (pump until the - Run the loop until the loop water
loop and the cleaning water 700TK1 tank temperature will exceed 75C
are empty)
21 / 35
Step 6
- Stop the sludge pump 500P1 - Fill cleaning water tank with 50-60C
technical water.
- Fill cleaning water tank with 50-60C
technical water. - Close the valves V307;V455;V456;V417
- Carefully open V417 approx. 30% - Adjust V704 so that loop suction
pressure is close to 1bar
- Adjust V704 so that loop suction
pressure is close to 1bar - Stop the loop pump 300P2
- Close
V703;V704;V417;V416;V502;V506;V507;
- Stop the loop pump 300P2
V509
- Stop the feed pump 300P1
- Open V415;V458
- Drain the loop by opening valves
- Set all remote controlled pumps and
V456;V455;V307;V417;V704;V502;V506;
valves back to AUTO mode
V507;V509 to mixing tank 500TK1
- Set system backflush to AUTO mode
- Start sludge pump 500P1 (pump until the
loop and the cleaning water 700TK1 tank
are empty)
Now the system is cleaned with alkaline
and acid cleaning agents and rinsed with
Step 7
22 / 35
23 / 35
out. If the water goes lighter it means that Mixing tank has high level alarm which will
it`s clean enough and you can stop stop the transfer pump 500P1. Mixing tank
pumping. high-level alarm is activated if mixing tank
high-level switch signal is active after
WARNING: Always use safety
adjusted time delay (transfer to the belt
glasses and rubber gloves when
filter not possible).
operating with the belt filter system!
24 / 35
Picture 15. Belt filter settings The discharge line has a fine filter 400F1
Mixing tank mixer motor is running if to avoid dirt flakes entering from the Belt
mixing tank low-level switch is not active filter tank bottom mixing to purified water
and belt filter operation set to run-mode that is pumped to the system or
Filtered water is stored in separate belt When the discharge pumps 400P2 starts,
filter tank. When the filter tank high level first 15-20 seconds the water is led
switch indicates high level, 400P2 transfer through the fine filter. After the mentioned
pump starts to empty the tank (if allowed period bypass valve will be opened.
by the external scrubber control system) Note: Fine filter must be changed once
until the tank low level switch is activated. per month!
Belt filter tank high level alarm is activated
if high-level switch is still activated after
adjusted delay. Belt filter tank high-level
25 / 35
26 / 35
27 / 35
28 / 35
29 / 35
30 / 35
31 / 35
32 / 35
33 / 35
Specification list:
- beltfilter purified water pump 400P2: Grundfoss CRNE 3-4 3-4 A-FGJ-G-E-HQQE
34 / 35
Attachments:
Drawing P8007A.1900:01
Drawing P8007B.1900:01
35 / 35
FT
301
FCT
401
PCT PCT
401 402
LCSS
302
LI TI
301 LI 701
401
LT
301 PT PI
PCT
401 TI TE 305
TE 301
301 301 302 PI PI
304 PT
303
LCSS 301
301 PI
PI 302 PDI
301 301
LCS
GS GS
503
451 301
LCS
402
PI LCS
452 401
PI
451
PI
LCSS
502
501
PI
501
LCS
502
LCS
501
Turbidity
403
QT
Copyright of Langh Tech Finland, whose property this document remains. No part thereof may be disclosed, copied, duplicated or in any other way
made use of, except with the approval of Langh Tech Finland.
Drawn Scale
NSa 27.10.2015 Langh Tech
Checked
JTS 30.10.2015 Water Treatment System
Appvd. Metr.
KH 02.11.2015
Page
Name
1/1
CROE/RCCL WTS Size Drawing No: Revision
FT
301
LCS
"H"
LCS
"L"
FCT
401
PCT
PCT 402
401
LCSS
302
LI
301 LI
401
LT TI
301 PT 701 PI
PCT
401 TI TE 305
TE 301
301 301 302 PI PI
304 PT
303
LCSS 301
301
PI
PI 302 PDI
301 301
LCS
GS GS
503
451 301
LCS
402
PI LCS
452 401
PI
451
PI
LCSS
502
501
PI
501
LCS
502
LCS
501
Turbidity
403
QT
H BACK FLUSH TANK, V514 AND POLYMER MIX UNIT INFO ADDED 26.04.2016 KH LL
G pH RANGE UPDATED 13.04.2016 KH LL
F INSTRUMENTATION UPDATED 28.01.2016 KH LL
E RETURN LINE MODIFIED 18.12.2015 NSa JTS
D BACK FLUSH PIPING AND PUMP CAPACITY MODIFIED 16.12.2015 NSa JTS
C SECOND WASH WATER MONITOR MODIFIED, LOOSE TANK AND PUMP ADDED 16.12.2015 NSa JTS
B SECOND WASH WATER MONITOR ADDED, BACK FLUSH DRAINING ADDED 11.12.2015 NSa JTS
A INITIAL ISSUE 02.11.2015 NSa KH
Rev. Alteration or remark Date Drawn Appr.
Copyright of Langh Tech Finland, whose property this document remains. No part thereof may be disclosed, copied, duplicated or in any other way
made use of, except with the approval of Langh Tech Finland.
Drawn Scale
NSa 27.10.2015 Langh Tech
Checked
JTS 30.10.2015 Water Treatment System
Appvd. Metr.
KH 02.11.2015
Page
Name
1/1
CROE/RCCL WTS Size Drawing No: Revision