SET Press SET button. 0015 Press UP or DOWN button until AutO is
displayed.
Press UP or DOWN button until requested
value is displayed. (If pressed
buttons continuously, displayed value is 0020 SET Press SET button.
SET
changed quickly).
Press SET button to save. Press UP or DOWN button until requested
o
value is displayed.
Setting of High Setpoint Value (For EPM-4C and 4AC)
SET Press SET button to save.
oF
SET Press SET button for 3 sec.
Setting the Instant Tripping Function (For EPM-4C and 4AC)
Press UP or DOWN button until SP H is
displayed. sp h SET Press SET button for 3 sec.
SET Press SET button. 2500 Press UP or DOWN button until trP is
displayed.
Press UP or DOWN button until requested
value is displayed. (If pressed
buttons continuously, displayed value is 2750 SET Press SET button.
changed quickly). o
SET Press SET button to save. Press UP or DOWN button until
requested value is displayed.
oF
SET Press SET button to save..
DIGITAL AMMETER
EPM-4D / EPM-4C/ EPM-4A / EPM-4AC
Setting of Latch Function (For EPM-4C and 4AC) Technical Data
SET Press SET button for 3 sec. Operating Voltage (Un),*
Operating Range (DU) : Please look at labels on the device.
Press UP or DOWN button until LAtC is Operating Frequency (f) : 45-65 Hz
displayed.
Accuracy : 1% 1 digit [(%10-%100) full scale]
Measuring Input (Iin) : 0.05-5.5 A (for EPM-4D, 4C )
SET Press SET button.
o Measuring Range
0,07 -200 A (for EPM-4A, 4AC)
: 0,05 -10000 A with Ct
Press UP or DOWN button until requested
value is displayed. (for EPM-4D, EPM-4C )
oF 0,07-200 A (for EPM-4A, 4AC)
SET Press SET button to save. Current Transformer Ratio (Ct) : 5...10000 / 5A ( for EPM-4D, 4C)
Adjustment Contact Situation (For EPM-4C and 4AC) Power Consumption(Pcons) : <4 VA
Burden : <1 VA
SET Press SET button for 3 sec.
Output Contact : 5A, 250V, 1250VA (Resistive)
Press UP or DOWN button until Out is (for EPM-4C and 4AC)
displayed. Ins. Tripping : >1.5 x SP H or <0.5 x SP L
(for EPM-4C and 4AC)
SET Press SET button.
c Hysteresis
Delay Times
: 0-0.5 x Full scale (for EPM-4C, 4AC)
: 0.0 - 999.9 sec. (for EPM-4C, 4AC)
Press UP or DOWN button until requested
value is displayed. Demand Time (Average) :1-60 min. (for EPM-4A, 4C, 4D and 4AC )
o Enclosure : Non-flammable
SET Press SET button to save. Equipment Protection : Double Insulation ( ),
Measuring Category III
Escaping the Set Menu (For EPM-4A, 4C, 4AC and 4D) Ambient Temperature
O
: -5 C; +50 C
O
48mm
is assured by the manufacturer or any of its subsidiaries for any consequences arising out
of the use of this material.
Only for rack panel mounting. 72mm 96mm 96mm
TYPE PR 18(72x72) TYPE PR 19(96x96) TYPE PR 20(48x96)
Connection Diagrams
The Area Measurements on The Control Panel
Wall Wall Wall
EPM-4A EPM-4AC
79.3mm
82.5mm 70mm
75mm 63mm
4 3 2 1 6 5 4 3 2 1 54 mm
42mm
65.5mm
90mm
Output
43mm
1A
Contact
1A
1,5m 1,5m
L L
N N TYPE PR 18 TYPE PR 19 TYPE PR 20
Measuring Measuring
Input (Iin) Input (Iin)
50mm 50mm 50mm
43mm
EPM-4D EPM-4C
68mm 92mm 90,5mm
Output
Measuring l
in lin
Factory Settings :
1A
Contact
1A
Input
k l k l
L Measuring L Ctr = 0005 SP L = 0.250 (EPM-4C) Strt = 006.0
K L Input K L
N trn = 0001 HYS = 4.000 (EPM-4AC) AutO = OF
Warning : dE t = 0015 HYS = 0.100 (EPM-4C) trP = OF
SP H = 160.0 (EPM-4AC) On t = 010.0 LAtC = OF
a) A switch or circuit breaker must be connected between the network SP L = 10.00 (EPM-4AC) OF t = 010.0 Out = nO
and the auxiliary supply input of device. SP H = 4.000 (EPM-4C)
b) Connected switch or circuit breaker must be in close proximity to the device.
c) Connected switch or circuit breaker must be marked as the disconnecting
device for the equipment.
d) The type of the used fuse must be FF type and the current of the used fuse
must be 1A.
e) No need of a vantilator in the installation area
A3359/Rev-2