Sunteți pe pagina 1din 4

Motor- and Component- List

Sandvik Mining and Construction Crushing Technology GmbH (SMCT)


Position Scope of supply Technical Datas Accessory/ Notes Signals Spare Rev
fittings parts
Amount Design Power Speed Protection Fabrication, Type Design Amount / Supply code Kind Setpoint Alarm
supply KW min-1 class Voltage V Notes DI L / LL Proposal
code AI H / HH
A poles Frequenzy Hz
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Hybrid CR810
4
1

Motor
4.1 ABB it is possible to start and stop 3
2x MKL 250 1800 IP55 M3BP355SMC4 460 both motors at the same time.
399A 4 60
Motor winding temperature sensors
4.1.1 evaluation device
3x Temperature class F PTC nessecary PTC HH

Motor current monitoring


4.1.2 not in scope turn-off release signal evaluation device
of Sandvik 1z for feeding device nessecary >80%nN H

Gearbox
4.2
2x

Temperature control gearbox


4.2.1
1x PT-100 PT100 PT100 1

Temperature transmitter, gearbox approx.


4.2.1.1 2-wire <5C L
1x 4-20mA assembled at 4.2.1 4-20mA AI 80C H 3
wired to 4.8 90C HH
Cooling ventilator gearbox
4.2.3
1x MKL < 0,25 IP55 460 wired direct in line 2
60 with thermostate switch
Thermostate switch for cooling ventilator included terminal- on/off
4.2.3.1 box, contactor. Fan on / off. >xC<
1x Mounted at Wired direct in line manufac.
gearbox with cooling ventilator. default
Temperature control starting coupling
4.3
2x

2120125 SMC Peru CR810-08-30 M+C List Rev.3.xls 27.05.2012/04.05.2012 page 1 of 4


Motor- and Component- List
Sandvik Mining and Construction Crushing Technology GmbH (SMCT)
Position Scope of supply Technical Datas Accessory/ Notes Signals Spare Rev
fittings parts
Amount Design Power Speed Protection Fabrication, Type Design Amount / Supply code Kind Setpoint Alarm
supply KW min-1 class Voltage V Notes DI L / LL Proposal
code AI H / HH
A poles Frequenzy Hz
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Sensor temperature control starting coupling overbridging at start for
4.3.1 ~10 sec. ness.
1x 24 VDC 1
wired to 4.8
Evaluation device temperature control starting coupling
4.3.2 switch contact >xC HH
1x 24 VDC assembled DI manufac. 1
at 4.9 default
Small terminal box crusher (TB)
4.3.3 Rose assembled
1x >=IP 65 01.12.12.09 at crusher
with 10 terminals wired to 4.8
Compact speed sensor for slip monitoring (evaluation includ) overbridging at start for
4.4 ifm / Turck / ~10 sec. ness. DI <91%Nn LL 1
2x M30x1 IP67 Telemecanique 10-36 VDC wired to 4.8 PNP default
3-wire setting.
Bearing temperature sensors PT-100 (double PT-100)
4.5 Tematec
4x IP66 WT-014-1053 PT-100 wired to 4.8 PT-100 PT100 1
3-wire
Bearing temperature transmitter for sensor PT-100
4.5.1 2-wire >95C H
1x Tematec 4-20mA assembled 4-20mA AI >110C HH 1
TT2381-A31B000-150 at LOP (4.9) 0-150C
Greasing system for crusher bearing
4.6 Lincoln wired to 4.8 summary fault
1xx 0,072 IP6K9K P203 24 DC (default setting is a DI X
Mx intermittent signal)
Level monitoring of greasing system
4.6.1 Lincoln Reedcont.
1x 24V DC wired to 4.6

Progressive grease distributor monitoring


4.6.2 Lincoln
1x 24V DC wired to 4.6

Cabinet for greasing system


4.6.4
1 >= IP 55 (mounted at crusher)

2120125 SMC Peru CR810-08-30 M+C List Rev.3.xls 27.05.2012/04.05.2012 page 2 of 4


Motor- and Component- List
Sandvik Mining and Construction Crushing Technology GmbH (SMCT)
Position Scope of supply Technical Datas Accessory/ Notes Signals Spare Rev
fittings parts
Amount Design Power Speed Protection Fabrication, Type Design Amount / Supply code Kind Setpoint Alarm
supply KW min-1 class Voltage V Notes DI L / LL Proposal
code AI H / HH
A poles Frequenzy Hz
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Terminal box crusher (TB)
4.8 (most likely) assembled sensors/ actuators
1x >=IP 65 Rittal at crusher wired to clamps
600x400x120 (WxHxT) wired to 4.9
Local Operator Panel (LOP) power supply PLC System local/remote, Hybrid -
4.9 (most likely) 460VAC / 24VDC is not included. start/stop, Hydraulic on/
1x <= 1.5 >=IP 55 Rittal 460 included. With manually control for off, Gap +/-, Gap-displ., DI X 2
AE1077.500 3 phases the hydraulic. lamps, emergency Off.
760x760x210 (WxHxT) 60 Included 20m cable to TB Inching operation of rolls.
Digital signals to customer via potential free contacts.
Sensor for relative gap measurement (Ultrasonic)
4.10 P+F
1x UC500-30GM-IUR2-V15 24 VDC wired to 4.8 4 - 20 mA AI X

Display for relative gap measurement (with zero adjust


4.10.1 Montwill function compensate)
1x IP65 Digital panel meter 24 VDC built in in the front door 4 - 20 mA AI
5-digit at LOP (4.9)
Hydraulic aggregate
4.12
1x Bott / AROS oil tank ca. 35 litre

Motor
4.12.1 wired to 4.9, 3
1x MKL 1.5 1800 IP 55 460 None additional
4 60 MCC necessary.
Level-switch digital signal in case of
4.12.2 low level (switch contact
1x 24 V DC wired to 4.12.10 ) in collaboration with DI <Min L
4.12.3 < Min Min LL
Temperature-switch digital signal in case of
4.12.3 high temperatur (switch
1x 24 V DC wired to 4.12.10 contact) in collaboration DI >70C H
with 4.12.2 >80C HH
Pressure-switch for pressure-load
4.12.4 not used. switch contact
1x 24 V DC instead of this is 4.12.11 NC

Filter monitoring
4.12.5
1x 24 V DC wired to 4.12.10 switch contact DI > x bar H

2120125 SMC Peru CR810-08-30 M+C List Rev.3.xls 27.05.2012/04.05.2012 page 3 of 4


Motor- and Component- List
Sandvik Mining and Construction Crushing Technology GmbH (SMCT)
Position Scope of supply Technical Datas Accessory/ Notes Signals Spare Rev
fittings parts
Amount Design Power Speed Protection Fabrication, Type Design Amount / Supply code Kind Setpoint Alarm
supply KW min-1 class Voltage V Notes DI L / LL Proposal
code AI H / HH
A poles Frequenzy Hz
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Magnetic valve (Movement back)
4.12.6
1x 24 V DC wired to 4.12.10

Magnetic valve (Movement forward)


4.12.7
1x 24 V DC wired to 4.12.10

Heating
4.12.8 120 connection to MCC.
1x 0,75 1 phase temperature switch inside 2
60
Terminal box hydraulic sensors/ actuators
4.12.10 form hydraulic are
1x >=IP 65 Rittal wired to 4.9
or compatible (Industrial connector harting)
Pressure-switch for pressure-load (mounted at hydraulic cylinder)
4.12.11 both switches in serie, switch contact DI < 90 bar L
2x 24 V DC wired to 4.8 NC

Electrical dokumentation for the cusher station wiring + terminal diagramm,


5.0 P&ID, interlocking, and so on.
1x paper / PDF Language
English
Enviroment terms and conditions
5.1 temperature -20C - +40C

Name plates for cable and sensors


5.2
1
Code Column 2:
x = included in the supply of the mechanical equipment
xx = included in the supply of the mechanical equipment, including power circuit and control
z = supplied by customer

Code Column 3:
MKL = AC squirrel-cage motor

DI = digital input to PLC/DCSI


AI = analog input to PLC/DCS

2120125 SMC Peru CR810-08-30 M+C List Rev.3.xls 27.05.2012/04.05.2012 page 4 of 4