Sunteți pe pagina 1din 12

DETERMINAREA CONDUCTIVITII TERMICE

A MATERIALELOR DE CONSTRUCII
Lucia VLCEANU, Mihaela FLORI, Vasile PUAN

ABOUT THE DETERMINATION OF BUILDING MATERIALS


THERMAL CONDUCTIVITY
The paper introduces an experimental method of determining the
thermal conductivity of building materials. The installation we have created is
based on the Fourir law allows the determination of the thermal conductivity of
the building materials which the test bars are made of, and implicitly, theirs
identification. This method does not allow an observation of the variation of
thermal conductivity with respect to temperature for the material under question,
the result of the analysis being in fact a mean value of thermal conductivity.

Keywords: conductivity, thermocouples, thermal conductivity, thermal gradient


Cuvinte cheie: conductivitate, termocupluri, conducie termic, gradient termic

1. Introducere

Relaia de baz a transferului conductiv de cldur a fost stabilit


pe cale experimental n anul 1882 de ctre Fourir. Legea care-i poart
numele a fost verificat de numeroase experimente ulterioare i
niciodat infirmat. Conductivitatea termic [W/mK] reprezint
densitatea fluxului de cldur ce traverseaz o suprafa izoterm la un
gradient de temperatur de 1 oC/m. Deoarece, la transmiterea cldurii,
existena unui gradient termic presupune temperaturi diferite n diferite
puncte, ne intereseaz n mod deosebit variaia conductivitii termice cu

227
temperatura. Cercetrile experimentale au artat c pentru majoritatea
substanelor variaia lui cu temperatura poate fi aproximat printr-o
funcie liniar de forma:
W
0 1 t t0 (1)
m K
unde 0 corespunde unei temperaturi de referin t 0 , iar este un
coeficient caracteristic fiecrui material. Coeficientul pentru corpurile
solide poate fi pozitiv sau negativ n funcie de natura corpului.
O privire de ansamblu asupra valorilor conductivitii termice a
materialelor solide, lichide i gazoase rezult din Fig.1. Pentru
materialele de construcie se ncadreaz n intervalul (0,023) W/(mK)
i depinde mult de structura materialului, de porozitatea i de umiditatea
acestuia. Valorile cresc cu creterea temperaturii. La aceste materiale se
observ, de asemenea, o cretere a lui cu creterea densitii.

Fig. 1 Spectrul de valori pentru conductivitatea termic a diverselor


categorii de substane

2. Consideraii teoretice privind determinarea


conductivitii termice a materialelor de construcii

Cunoaterea coeficientului global de transfer termic k [W/m2.K] i


a conductivitii termice [W/m.K] se impune n multe domenii ale
tehnicii i n special n cazul izolaiilor termice, schimbul de cldur dintre
prile componente ale diverselor instalaii i mediul nconjurtor
constituind o problem deosebit de important.
Schimbul global de cldur ce are loc ntre dou fluide desprite
printr-un perete neomogen (figura 2) poate fi realizat din urmtoarea
succesiune a transferului termic: convecie i radiaie ntre fluidul 1 de
temperatur t f1 >t p1 i suprafaa B a peretelui avnd temperatura t p1 ;
conducie termic prin peretele neomogen format din straturile de
grosime d 1 , d 2 ,..., d n avnd conductivitile termice 1 , 2 ,..., n i

228
transferul termic prin convecie i radiaie de la suprafaa C a peretelui de
temperatur t pn+1 la fluidul 2, avnd temperatura t f2 <t pn+1 .
n cadrul schimbului global de cldur, aportul radiaiei termice la
transmiterea cldurii se ia n considerare prin coeficientul de transfer
termic de suprafa prin radiatie rad , rezultnd valoarea coeficientului
de transfer termic de suprafa :
conv rad [W/m2.K] (2)
2.
unde: conv [W/m K] - este coeficientul de convecie termic.
Astfel, transferul de cldur prin convecie i radiaie ntre fluidul
1 i peretele B, respectiv ntre peretele C i fluidul 2, se nlocuiete cu un
transfer de cldur de suprafa. Rezult c transferul de cldur dintre
fluidul 1 i suprafaa B a peretelui va fi:


Qf1 1 A t f1 tp1 [W] (3)
unde: 1 [W/m2 K] - este coeficientul de transfer termic de suprafa de
la fluidul 1 la perete. Din relaia (3) rezult:

Qf1
t f1 tp1 (4)
1 A
Conform legii lui Fourir, fluxul de
cldur transmis prin primul strat al
peretelui este dat de relaia:


Q1 1 A tp1 tp2
d1

(5)

unde: 1 [W/mK] - este conductivitatea


Fig. 2 Distribuia temperaturii termic a primului strat din perete.
ntre fluide desprite printr-un
perete plan neomogen Diferena de temperatur n stratul de
grosime d 1 al peretelui se obine din
d1
relaia (5): tp1 tp2 Q1 [C] (6)
1 A
n mod analog, rezult:
d2 dn
tp2 tp3 Q2 (7) tpn tpn1 Qn (8)
2 A n A
Prin asemnare cu relaia (4) se exprim diferena dintre temperatura

Qf 2
suprafeei C i temperatura fluidului 2: tpn t f 2 (9)
2 A

229
Considernd procesul de transmitere a cldurii staionar, adic

Qf1 Q1 Q2 ... Qn Qf 2 Q , i adunnd relaiile (4), (6) i
(8), rezult:

Q 1 d d d 1
t f1 t f 2 1 2 ... n [C] (10)
A 1 1 2 n 2
Din relaia (10) rezult:
1
Q A t f1 t f 2 k A t f1 t f 2 (11)
n d
1 1
i
1 i1 i 2
1
W / m2 K
unde: k (12)
1 di 1
n

1 i1 i 2
se numete coeficient global de transfer termic.
Dac se consider numai procesul de transmitere a cldurii prin
conducie n interiorul peretelui neomogen, din nsumarea relaiilor

Q n d
(6)(8), rezult: tp1 tpn1 i (13)
A i1 i


de unde : Q A tp1 tpn1
di
1
e A tp1 tpn1 [W]
nd
(14)

i1 i
Conductivitatea termic echivalent a peretelui cu grosimea
d
total d [m] va fi: e [W/m.K] (15)
n d
i
i1 i
n situaia n care peretele este format dintr-un singur tip de

material, relaia (14) devine: Q A tp1 tp2 [W]
d

(16)

unde: [W/m.K] i d [m] reprezint conductivitatea termic a materialului


peretelui, respectiv grosimea peretelui, iar tp1 i tp2 [0C], temperaturile
pe cele dou fee exterioare ale peretelui.

Astfel, conductivitatea termic va fi:

230

Q d
(17)

A tp1 tp2
n tabelul 1 sunt nscrise valori (din literatura de specialitate) ale
conductivitii termice specifice unor materiale de construcie.
Tabelul 1
Conductivitatea Conductivitatea
Material termic Material termic
. .
[W/m K] [W/m K]
Beton 1,45 Poliuretan 0,018
Crmid 0,90 Polistiren extrudat 0,035
BCA 0,40 Polistiren expandat 0,040
Lemn placat 0,10 Vat mineral 0,041
Lemn de stejar 0,37 Plut 0,045
Lemn de pin 0,28 Piatr 2,90

3. Schema instalaiei experimentale

n funcie de starea de agregare a materialului analizat exist


diverse metode experimentale de determinare a conductivitii termice.
n cazul materialelor solide, cea mai cunoscut metod const n
msurarea diferenei de temperatur pe feele unei epruvete
paralelipipedice cunoscnd valoarea fluxului termic care o traverseaz.
Instalaia experimental (figura 3) se compune dintr-un vas
calorimetric (1) nclzit prin intermediul unei rezistene electrice (2).
Temperatura pe feele exterioare ale epruvetelor (3) se determin cu
ajutorul a trei termocupluri (T 1 -T 3 ) cuplate fiecare la logometre. Modul de
amplasare al celor 3 termocupluri se poate observa n figura 3.

Fluxul de cldur Q [W] va traversa epruvetele de jos n sus, iar valoarea
acestuia se va determina n funcie de tensiunea i intensitatea
curentului electric folosit pentru nclzirea rezistenei electrice (2) cu

relaia: Q = U .I [W] (18)
Epruvetele cu suprafaa de 150x150 mm au practicate pe feele
exterioare cte un canal pentru fixarea termocuplurilor astfel nct
contactul ntre dou epruvete suprapuse s se realizeze perfect.
Determinrile experimentale vor ncepe dup ce n vasul
calorimetric s-a ajuns la starea de echilibru termic. n acest scop,
nclzirea va ncepe cu cteva minute nainte de nregistrarea datelor
experimentale.
Dup obinerea regimului staionar de transfer de cldur, se
determin consumul de energie electric prin msurarea intensitii I [A]

231
i a tensiunii U [V] curentului electric de alimentare a plcii de nclzire
din vasul calorimetric, cu ajutorul unui multimetru.
Fig. 3

Schema instalaiei
experimentale:
1 vas calorimetric;
2 plac de nclzire;
3 epruvete; T 1 , T 2
i T 3 termocupluri

Pentru simplificare, se consider c ntreg fluxul termic degajat


de rezistena electric traverseaz seciunea epruvetei.

4. Concluzii

Autorii lucrrii au conceput i realizat practic un stand


experimental care permite determinarea conductivitii termice a unor
materiale de construcii din care sunt confecionate epruvetele (3).
Standul experimental se afl n dotarea laboratorului de Termotehnic i
agregate termice al Facultii de Inginerie din Hunedoara, permind
realizarea de ctre studeni de msurtori efective cu ajutorul acestuia.
Precizia msurtorilor este afectat de soluiile alese pentru
izolarea termic a instalaiei fa de mediul ambiant, subliniindu-se faptul
c fluxul de cldur s-a considerat unidimensional i staionar.
Dup stabilirea echilibrului termic, valoarea lui determinat
cu relaia (18) corespunde temperaturii medii din instalaie.

BIBLIOGRAFIE

[1] Puan, V., Agregate termice, Editura Cermi, Iai, 2008.


[2] Vlceanu, L., Flori, M., Termotehnic. Aplicaii practice, ndrumar laborator,
Editura Politehnica Timioara, 2009.
[3] Vlceanu, L., Transfer de cldur i instalaii termice, Editura Cermi, Iai,
2008.

Conf.Dr.Ing. Lucia VLCEANU, lucia.vilceanu@fih.upt.ro


Asist.Dr.Ing. Mihaela FLORI, mihaela.flori@fih.upt.ro
ef lucr.Dr.Ing. Vasile PUAN, vasile.putan@fih.upt.ro
Universitatea Politehnica din Timioara, Facultatea de Inginerie Hunedoara,
Hunedoara, str. Revoluiei, nr.5, cod 331128
membri AGIR

232
DETERMINAREA EXPERIMENTAL A
PERFORMANELOR GENERATORULUI
DE AER CALD TIP A20
Florin MRCU, Mihai JDNEAN

EXPERIMENTAL DETERMINATION OF THE


PERFORMANCE OF COMBUSTION HEATER TYPE A20

This paper presents experimental determination of the performance of


combustion heater A20. The experimental work presented method and results
of these determinations.

Keywords: hot air generators, experimental measurements


Cuvinte cheie: generatoare de aer cald, msurtori experimentale

1. Determinri experimentale i calcule efectuate pentru


determinarea performanelor generatorului de aer cald A20

Determinarea performanelor generatorului de aer cald


presupune determinarea puterii termice, debitul de aer cald, creterea
temperaturii aerului, temperatura maxim a aerului cald, randamentul
i determinarea calitii arderii prin determinarea noxelor i a indicelui
de fum a gazelor de ardere evacuate de instalaie conform Directivei
nr.56/2001/CE.
Determinrile s-au realizat pe standul de prob a
generatoarelor de aer cald existent la firma Mecord.
Determinrile experimentale s-au realizat pe un generator de
aer cald tip A20 (figura 1) cu tensiunea nominal de 12 V care
utilizeaz combustibil lichid motorin.

233
Fig. 1 Generator de aer cald tip A20
(1-compresor, 2-motor, 3-ventilator, 4-automatizare, 5-bujie, 6-camera de
ardere, 7-cazan, 8-tub de flacr, 9-ntoarcerea gazelor de ardere, 10-cap
incandescent, 11-vaporizator)

2. Metoda de determinare experimental a puterii termice,


debitul de aer cald, creterea de temperatur a aerului i a
randamentului

Metoda de determinare experimental este prezentat tabelar


(tabelul 1) i const n msurarea valorilor parametrilor de funcionare
i determinarea prin calcul a caracteristicilor generatorului de aer cald.
Tabelul 1
Mrimea msurat sau calculat Mod de obinere
Frecvena pompei (Hz) msurare
Turaia motorului (rot/min) msurare
Tensiunea de alimentare (V) msurare
t msurare
Temperatura aer la intrarea, ar (0C)
t msurare
Temperatura aer cald, ac (0C)
Diferena de temperatur intrare-ieire, (0C) t ac t ar
-
Viteza aerului msurat cu anemometrul msurare
w ac Diagrama anemometrului
Viteza aerului la ieire (m/s)
Diametrul interior al seciunii de ieire a msurare
aerului cald Di (mm)

234
2 6
S ( x Di )/(4 x 10 )
Seciunea de ieire a (m )
2

Debitul volumic de aer calculat (m3/h) S w


3600 x ac ac
tabele termotehnice
Densitatea aerului la ieire ac (Kg/m3)
Da Da S aw ac ac
Debitul masic de aer (Kg/h)
Temperatura medie aer n generator (0C) (tac + tar)/ 2
tabele termotehnice
c
Cldura specific la t. medie pa (J/KgK)
Puterea termic a instalaiei Pt (W)
Dac pa t ac t ar
3600

Randamentul generatorului
d Dac pa t ac t ar
1000 mC hQd

Cldura disponibil i densitatea motorinei sunt:

Qd Qi 41850
kJ/kg (1)
m
= 0,880 kg/l (2)

Determinrile experimentale s-au realizat pentru msurarea


puterii termice pe treapta de putere maxim, pentru trei valori ale
tensiunii electrice de alimentare, i pe treapta de putere minim la
tensiunea nominal.
Rezultatele obinute au fost nregistrate n tabelul 2:

Tabelul 2
Mrimea msurat sau calculat Pmaxim Pmaxim Pmaxim Pminim
Frecvena pompei (Hz) 3,96 3,97 3,96 2,30
Turaia motorului (rot/min) 5750 9250 6600 4700
Tensiunea de alimentare (V) 10,5 18 12,2 12,2
Temperatura aer la intrare, tar (0C) 22 23 22 22
Temperatura aerului cald, tac (0C) 104 73 92 78
Diferena de temperatur intrare- 82 50 70 56
0
ieire, ( C)
Viteza aerului (div/min) 390 560 440 300
Viteza aerului la ieire wac (m/s) 6,8 9.4 7,6 5,2
Diametrul interior al seciunii de 63 63 63 63
ieire a aerului cald Di (mm)
Seciunea de ieire Sa (m2) 0,00312 0,00312 0,00312 0,00312
Debitul volumic de aer (m3/h) 76,2 105 85,4 58,5

235
Densitatea aerului la ieire 0,939 1,100 0,960 1,010
3
ac (kg/m )
Debitul masic de aer Da (kg/h) 71,6 115,5 82,0 59,0
Temperatura medie a aerului n 63 48 57 50
generator tm (0C)
Cldura specific la temperatura 1009 1008 1009 1008
medie cpa (J/kgK)
Puterea termic a instalaiei Pt (W) 1638 1601 1605 923
0,728 0,711 0,713 0,750
Randamentul generatorului d

Tabelul 3
Consumul orar (l/h)
Tensiunea de alimentare (V) 10,5 18 12,2
Treapta 1-minim 0,12 0,12 0,12
Treapta 2 0,14 0,14 0,14
Treapta 3 0,165 0,165 0,165
Treapta 4 0,190 0,190 0,190
Treapta 5-maxim 0,22 0,22 0,22

Se constat c valorile msurate ale consumurilor orare de


motorin (tabelul 3) nu difer funcie de tensiunile de alimentare.
Acest aspect se explic prin faptul c blocul electronic asigur
aceeai frecven de acionare a pompei de motorin cu piston,
indiferent de tensiunile de alimentare.
Aceast situaie nu este convenabil, deoarece suflanta i
modific turaia funcie de tensiunile de alimentare, modificndu-se i
coeficientul excesului de aer, debitele de motorin fiind cvasi constante.
Pentru a combate aceast situaie este necesar s se asigure
la optimizarea procesului de ardere un exces de aer acoperitor la
tensiunea electric minim admis de funcionare a generatorului de aer
cald.
n tabelul 4 s-au nregistrat i temperaturile gazelor de
evacuare.

Tabelul 4
12,2 V tg (0C)
Treapta 1- minim 244
Treapta 2 326
Treapta 3 300
Treapta 4 331
Treapta 5 - maxim 327

236
3. Determinarea calitii arderii

Determinarea calitii arderii s-a realizat prin determinarea


noxelor i a indicelui de fum a gazelor de ardere evacuate de instalaie
conform Directivei nr.56/2001/CE.
S-au fcut determinri pentru toate cele 5 trepte de funcionare
programate (tabelul 5).
Tabelul 5
Uniti HC NOx CO
Bacarach (ppm) (ppm) (ppm)
Valori admise Max.4 Max.100 Max.200 Max1000
de Directiva CE
Treapta 1 3 9 173 32
Treapta 2 3 5 185 45
Treapta 3 3 3 186 48
Treapta 4 3 3 190 35
Treapta 5 2 0 193 5

Calitatea arderii se ncadreaz n valorile admise de


prevederile Directivei 56/2001/CE.
Pentru obinerea valorilor msurate s-a utilizat urmtoarea
aparatur:

- termometru electronic cu termocuple cromel-alumel


- analizor de gaze
- anemometru
- multimetru electronic
- frecvenmetru
- turometru
- cronometru
- eprubet gradat
- aparat determinare indice de fum
- stand probe generatoare aer cald

BIBLIOGRAFIE

[1] Baehr, H.D., Stephan, K., Heat and mass transfer, Springer Verlag, Berlin,
Heidelberg, 2006.
[2] Ionel, I., Ungureanu, C., Bisorca, D., Termoenergetica i mediul, Editura
Politehnica Timioara, 2006.
[3] Leca, A., .a., Transfer de cldur i mas, Editura tehnic, Bucureti, 1998.

237
[4] Mrcu, F., Jdnean, M., Combustion research in burner with fuel
distribution on standing vaporizer for combustion heaters, Cofret 2008, 4-eme
edition du Colloque Francophone en Energie, Environnement, Economie et
Thermodynamique, 11-13 Juin 2008, Ecole des Mines de Nantes, ISBN
2.6905267.61.5.
[5] Bejan, M., n lumea unitilor de msur. Ediia a doua revzut i adugit.
Editura Academiei Romne i Editura AGIR, Bucureti, 2005.

Drd.Ing. Florin MRCU,


Universitatea Politehnica Timioara,
e-mail: florin.marcut@yahoo.com
Prof.Dr.Ing. Mihai JDNEAN,
Facultatea de Mecanic, Universitatea Politehnica din Timioara,
membru AGIR
e-mail: mihai_jadaneant@yahoo.com; mihai.jadaneant@mec.upt.ro

238

S-ar putea să vă placă și