Calibrating Vaisala Continuous minimizes downtime by keeping and optimal performance of your
Monitoring Systems (CMS) on site your monitoring system in place and CMS, the system sends a reminder
helps to maximize reliability and operational. Certain calibrations when calibration is due.
profitability by minimizing costly require removal of the device from
equipment downtime, removing process. For these situations Vaisala Complete Documentation
the need for in-house or factory offers rental devices and device The Vaisala On-Site Calibration
calibration, and allowing your staff swap services to ensure continuity Service provides a thorough
to focus on what is truly important of monitoring and gap-free data. By analysis with comprehensive
your business. outsourcing calibration to Vaisala, paper and digital documentation,
you remove the need to invest in including a calibration certificate to
Reliable On-site specialized calibration equipment ensure verification and standards
Calibration for Life and training allowing staff to focus compliance. Calibration reports,
Science Applications on their primary tasks. data sheets, and calibration labels
On-site Calibration Service offers We provide you with a range of can be supplied on-site, with digital
a range of benefits over the single and multi-point calibration backup files saved to disk. Our
conventional options of either options using application-specific highly accurate calibrations fulfill
shipping equipment back to the reference instruments, complete with international standards and make
manufacturer or calibrating in- a certificate of NIST-traceability. To it easy to comply with regulatory
house. Reliable on-site calibration maintain the high levels of accuracy requirements.
Technical Data
Single Point Calibration
Temperature Temperature for Liquid Nitrogen Applications
Range -90 C to +70 C Range -196 C
Unit Under Test acceptance limits +/-1 C Unit Under Test acceptance limits +/-3 C
Calibration points One point at point of use Calibration points One point at point of use
Adjustment Not available Adjustment Not available
Certificate Includes as-found / as-left data Certificate Includes as-found / as-left data
Traceability NIST Traceability NIST
Available for the following devices Vaisala Temperature Available for the following devices Vaisala Temperature
Data Loggers Data Loggers DL1700
DL1000, DL1016, DL1400, DL1416, DL2000, HMT140 Reference instrument Vaisala Temperature Data Logger
Reference instrument Vaisala Temperature Data Logger
Accredited Calibration
Temperature Relative Humidity
Range 0 C to 70 C Range 11 to 95 %RH at 0 to 70 C
Unit Under Test acceptance limits +/-0.6 C Unit Under Test +/- 2 %RH +/- 0.6 C (device dependent)
Calibration points Application dependent acceptance limits
Adjustment Yes Calibration points Application dependent
Certificate Includes as-found/ Adjustment Yes
as-left data and uncertainties Certificate Includes as-found / as-left data and uncertainties
Traceability NIST Traceability NIST
Available for the following devices Vaisala Temperature Available for the following devices Vaisala Humidity
Data Loggers Data Logger DL2000
DL1000, DL1016, DL1400, DL1416, DL2000 Vaisala HUMICAP Humidity and
Vaisala HUMICAP Humidity and Temperature Transmitter Series HMT330
Temperature Transmitter Series HMT330 Reference instrument Thunder Scientific 2500
Reference instrument Thunder Scientific 2500