Sunteți pe pagina 1din 5

Gas Detection

Touchpoint Plus
A whole new control experience
Unique User Experience
Taking the user experience to a whole new level

Want to Want
fully utilise complete peace
your controller? of mind?

Touchpoint Plus Built for ease


so you can operate it
Engineered to the highest
standards of quality and
with confidence reliability
Touchpoint Plus brings a whole new control experience to your small system of gas
detectors. Touchpoint Plus is an easily configurable, wall mounted control system
Want a simple
that supports up to sixteen channels of gas detection. Its modular approach enables end-to-end
you to take control and configure what you need for a wide range of applications. solution? Want to
simplify system
Easy ordering, installation setup?
and servicing from the
gas detection experts With the intuitive,
ergonomic touchscreen,
setup couldnt
be easier

Want to make
Delivering reliable control
fast, informed
Honeywell reliability from the
most trusted experts in gas decisions?
detection Want to
Built-in battery backup for know whats
constant uptime System status at-a-glance
Robust, shockproof housing when time is critical going on?
for a wide range of industrial
environments
The signature feature of the Touchpoint line is a user-friendly touchscreen interface, View real-time and
Flexible capabilities historical data, analyse
and the Touchpoint Plus takes it to a new level. With this unique interface, its easier
Compatible with the full range readings and
than ever to see the status of your system at a glance - maximizing the time you have
of Honeywell gas detectors much more
Powered audiovisual alarms to make the right decisions. The intuitive, multilingual interface, simplifies operation
simplify field installation
and reduces training requirements. The full colour traffic light style status indication
Configuration includes easy
grouping and voting alarm logic provides clarity from a distance too.
without specialist knowledge
Next-generation compatibility Touchpoint Plus includes a comprehensive set of outputs as standard including Large colour
Optional Modbus output for touchscreen LCD
integration with a higher level common alarms and dedicated drives for remote audiovisual indicators. Its with multilingual
system modularity enables you to customise your system to meet your specific application options
Clear common
Providing ease and efficiency requirements. Selecting the right detector for use with your controller can deliver
status indicators
Quick and easy installation, significant savings in startup costs and on-going operations. Our global partner (green, yellow, red)
configuration, commissioning
and maintenance
network and dedicated application specialists are able to help make the right choices
Built-in sounder Mute/reset
Easy diagnostics, data for your industry.
and reporting
Minimised training time
Large colour touchscreen LCD With everything at your fingertips, you can take ownership of your
Multilingual capabilities
Green-yellow-red status
system and operate it with confidence, ensuring the safety of your
at a glance people and productivity of your site. Individual channel status indicators (green, yellow, red)
Designed for speed
One System Solution and reliability
Made of high-impact polymer plastic,
Touchpoint Plus is versatile and durable.
Honeywell Analytics one system Its dust-proof, water-proof and
solution to meet your safety XNX Universal
has been tested to withstand the
Relays, actuators and Transmitter
requirements audio/visual alarms toughest environments in which
Touchpoint Plus provides a reliable our customers operate - indoors
safety solution for small scale gas and out. So you can count on
detection systems across a wide range of the Touchpoint Plus to stand up
applications and industries. If you need to Cloud to the challenges of industrial
integrate your gas detection with a higher environments, from mechanical
level management system, the Modbus rooms to chemical plants.
output option makes this straightforward.
Touchpoint Plus is supplied with
As the heart of your gas detection system, pre-drilled and sealed cable
Touchpoint Plus is designed to work with SD Card Sensepoint entries and a unique tiered
Honeywells industry leading gas detectors internal arrangement providing
and drive actuators, audible and visual ease of access to save installers
alarms to provide a complete end-to-end time and money.
solution that you can configure as your own.
mV bridge
mA loop sensors 1. Main module
sensors
2. Input module
7 5
End user
4 3. Relay output module
4. mA output module

6 5. Power supply
8
10 3 6. Display module
TYPICAL EXAMPLE OF A SMALL 7. Touchscreen
2
GAS DETECTION SYSTEM USING 9 1
8. Backup battery

TOUCHPOINT PLUS 9. Modbus TCP/Web


10. Modbus RTU

Key

Touchpoint
Plus
Control
System Configuration Options
System Not included in Expansion Unit

Touchpoint
Provided as standard Alarm 1 Alarm 2 Fault Visible Failure Configurable 4-20mA 4-20mA

Plus Dedicated powered audiovisual


Expansion alarm drives
Unit Common alarm outputs, one for Dedicated Audible/Visual Alarm Outputs System State Relays
fault and two configurable
12 12 4 4
Gas Datalogging to SD Card Outputs Outputs Outputs Outputs
Detector Remote reset and inhibit inputs
Alarm 1 Alarm 2 Alarm 3

1 0 0
SD Card
Audible & Options
Visual Alarm Choice of AC mains or DC
Fault

0
Warning

0
Inhibit

0
supply voltage Input/Output
Remote
Optional backup battery Inhibit
Choice of inputs: 2, 4 or 8 mA; 2, 4 or Buzzer Mute/Reset
Remote 01 02 03 04 05 06 07 08
8 mV; 2 mA and 2 mV; 4 mA and 4 mV Reset 09 10 11 12 13 14 15 16
Optional expansion unit for up to
16 inputs
Choice of 12 or 24 relay outputs
Choice of 4 or 8 mA outputs Power Supply Backup Battery
Optional RS485 Modbus RTU
Optional TCP/IP Modbus/HTTP
110/220 VAC 18-32 VDC 2, 4 or 8 Inputs
2-Wire 4-20mA
3-Wire 4-20mA
3-Wire mV Bridge
Installation
GENERAL SPECIFICATION GENERAL SPECIFICATION
Up to 8 channels with base unit, up to 16 Available I/O Modules continued
Capacity
channels with expansion unit Catalytic type flammable gas detectors
2 or 3 wires, mA, mV, max. 15W per channel, mV Input (Honeywell models). 2/4/8 channel
Quick and easy installation - designed to save Type of Inputs max 40W total (with dedicated A/V drive) / modules, 10/12/16 with expansion unit
68W total (without dedicated A/V drive) 2 channel mA + 2 channel mV module or
you time and money 426 mm 300 mm 156 mm
Dual Input
4 channel mA + 4 channel mV module
Size (wall-mounted version)
Touchpoint Plus can be directly wall mounted, or for an easier (16.8 x 11.8 x 6.1) 12 or 24 relay outputs, NO/C/NC
Housing Material Polycarbonate ABS changeover, 1.7A@30VDC/250VAC,
1-man installation use the optional mounting plate. Open the Relay Output
user configurable - energised/de-energised,
hinged front cover to find plenty of space for wiring and a unique Max 8.5 kg (18.7 lb), max 17 kg (37.4 lb) latching/non latching, time delay
Weight
with expansion unit
tiered terminal arrangement for easy access. Cable entries are 4 or 8 isolated repeated mA outputs,
User Interface (UI) - Controller Only
4-20mA Output
0-22mA, 0-100%FSD = 4-20mA
pre-drilled and sealed ready to use reducing installation time
Display 7 colour LCD touchscreen. Graphic User Interface Common Inputs Remote reset, remote inhibit
and cost further. 3 LEDs for master indicators. LED for each Four powered A/V outputs for alarms and
Common Outputs
Visual Indicators channel. Green: Normal; Yellow: Fault: fault, three common alarm outputs
Inhibit; Red: Alarm
15 6mm Approvals
Audible Alarm 70dB @ 1m
Electromagnetic EMC/RFI (EN 50270:2015)
Button Common for reset/mute operation LVD (EN 61010-1:2010)
Compatibility and CSA-C22.2 No. 61010-1-04
English, French, German, Italian, Dutch, Electrical Safety
Language UL 61010-1 (3rd Edition) and 508
Spanish, Portuguese, Russian, Chinese
Designed to meet - EN 50271:2010; EN
300mm

Power Supply*
60079-29-1:2007; EN 45544-1 /-2
Touchpoint Plus is supplied with 13 pre-drilled and sealed Power AC 110/220VAC, 50-60Hz Manual switching Performance**
/-3:2015; EN 50104:2010 C22.2 No. 152-
cable entries for for PG16/M20 glands. Power DC 18 to 32 VDC (+/-10%) Typical 24VDC M1984, ISA 12.13.01
Direct Surface Mounting Max 105W (including detector and external Designed to meet - IEC/EN 61508:2010
Power Consumption
devices), max 210W with expansion unit Safety Integrity** and EN 50402:2005+A1:2008 SIL2
Environmental certification
42 6m
m Class I, Division 2, Group A, B, C and D
-10C to +55C (14F to +131F) Hazardous Location
Operating continuous, up to 95% RH (non- or non-hazardous only
Optional Mounting Plate condensing), IP65 and NEMA 4X Others
Instrument -25C to +60C. (-13F to +140F), 22.2V Lithium Ion Battery, 2600mAh
Storage Backup Battery
up to 95% RH (non-condensing) capacity (>30 minutes for typical system)
Available I/O Modules Data logging Configuration, logged events and data
2 or 3 wire, 2/4/8 channel modules, MODBUS TCP, WEB monitoring and
Sensor Connection - compatible with a wide range of field devices 4-20mA Input
10/12/16 with expansion unit
Communication
MODBUS RTU
+24 Vdc * Basic and expansion units each require a power supply
External 24 VDC
GND
Supply ** Contact Honeywell Analytics for availability
Touchpoint Plus mA Input Module

Touchpoint Plus mA Input Module

Touchpoint Plus mA Input Module

Touchpoint Plus mV Input Module


+ +V
+24 vdc +24 vdc +24 Vdc *** Not available in Expansion Unit
+VE +VE +VE Sensitive
4-20mA Bead
Sensor

Signal Signal
ORDERING INFORMATION
Sensor

Sensor

Sensor

SIG SIG 4-20mA SIG Non-


4-20mA 66 Sensitive
-VE 66 66 Bead -V
-VE -VE _
0 Vdc
0 Vdc 0 Vdc

2-wire Loop Powered 3-wire Current Source 3-wire Externally Powered 3-wire mV Bridge
Output Option
4: 4ch mA Output
8: 8ch mA Output
N: No mA Output Battery
Power
Mounting Type B: Backup Battey
A: AC N: None
AVAILABLE GAS DETECTORS D: DC W: Wall Mount

Sensepoint
Simple devices, intrusive
Signalpoint

TPPLBAWA 8 S 8 BN N N
configuration, power up
to 8 devices directly from Product Name Future Use
705
Touchpoint Plus
Searchpoint Optima Plus Communication***

Sensepoint XCD N:None


Unit Type Input Option
R: MODBUS TCP+WEB(read)
Enhanced devices, non-
Series 3000 MkII/MKIII B: Base Unit A2: 2ch mA Input Communication*** T: MODBUS TCP
intrusive local operation,
E: Expansion Unit A4: 4ch mA Input W: MODBUS TCP+WEB(read/write)**
adjustment in field, power R: MODBUS RTU
RAEGuard II PID up to 8 devices directly A8: 8ch mA Input
V2: 2ch mV Input N: None
from Touchpoint Plus
IAQPoint2 V4: 4ch mV Input
V8: 8ch mV Input
D4: 2ch mA+ 2ch mV input Relay Option
XNX Universal Transmitter High integrity devices, D8: 4ch mA+ 4ch mV input
specialised configuration, S: 12 Relays
Searchline Excel adjustment in the field, D: 24 Relays
monitor up to 8 devices with N: No Relays

E3Point, EC F9, IR F9 external power as required

Note: Other field devices available on request. Some devices are not available in all regions.
oneywell Analytics is able to provide gas detection solutions to meet the requirements of all
pplications and industries. Contact us in the following ways:
Honeywell Gas Detection
Headquarters
Honeywell is able to provide gas detection solutions to meet the requirements of all applications
Europe, Middle East, AfricaContact us in the
and industries. Americas
following ways: Asia Pacific
fe Safety Distribution AG Honeywell Analytics Distribution Inc. Honeywell Analytics
avastrasse 2 405 Barclay Blvd. Asia Pacific
604 Hegnau Lincolnshire, IL 60069 #701 Kolon Science Valley (1)
witzerland HEADQUARTERS USA 43 Digital-Ro 34-Gil, Guro-Gu
el: +41 (0)44 943 4300 Tel: +1 847 955 8200 Seoul 152-729
ax: +41 (0)44Europe, Middle East, Africa
943 4398 Americas
Toll free: +1 800 538 0363
Asia Pacific
Korea
Life Safety Distribution GmbH Honeywell Analytics Distribution Inc. Honeywell Industrial Safety
asdetection@honeywell.com
Javastrasse 2 Fax: +1405847 955 Blvd.
Barclay 8210 Tel: +82 (0) 2 6909 0300
7F SangAm IT Tower,
8604 Hegnau Lincolnshire, IL 60069
detectgas@honeywell.com Fax: +82 (0)Buk-ro,
434 Worldcup 2 2025Mapo-gu,
0328
ustomer Service:
Switzerland USA India Tel:
Seoul 03922 +91 124 4752700
el: 00800 333 222 44 (Freephone number)
Tel: +41 (0)44 943 4300 Tel: +1 847 955 8200 Korea
el: +41 44 943 analytics.ap@honeywell.com
Fax:4380 (Alternative
+41 (0)44 943number)
4398 Toll free: +1 800 538 0363 Tel: +82 (0) 2 6909 0300
ax: 00800 333 222 55
gasdetection@honeywell.com Fax: +1 847 955 8210 Fax: +82 (0) 2 2025 0328
Middle East Tel: +971 4 450
Customer Service:
5800 (Fixed Gas Detection) detectgas@honeywell.com India Tel: +91 124 4752700
Middle East Tel: analytics.ap@honeywell.com
Tel:+971
008004 333
450222 585244(Portable Gas Detection)
(Freephone number)
Tel: +41 44 943 4380 (Alternative number)
Fax: 00800 333 222 55
Middle East Tel: +971 4 450 5800
(Fixed Gas Detection)

echnical Support Centres


Middle East Tel: +971 4 450 5852
(Portable Gas Detection)

oneywell Analytics Ltd. Honeywell Analytics Honeywell Analytics Honeywell Analytics


Stinsford Road ZAC Athlia 4 - 375 avenue du Mistral Elsenheimerstrasse 43 P.O. Box-45595
TECHNICAL SUPPORT
uffield Industrial Estate Bt B, Espace Mistral 80687 Mnchen 6th Street
oole, Dorset,EMEA:
BH17HAexpert@honeywell.com
0RZ 13600 La Ciotat Germany Musaffah Industrial Area
nited Kingdom France
US: ha.us.service@honeywell.com Tel: +49 89 791 92 20 Abu Dhabi
AP: ha.ap.service@honeywell.com
el: +44 (0) 1202 645 544 Tel: +33 (0) 4 42 98 17 75 Fax: +49 89 791 92 43 UAE
ax: +44 (0) 1202 645 555 Fax: +33 (0) 4 42 71 97 05 Tel: +971 2 554 6672
Fax: +971 2 554 6672

MEA: HAexpert@honeywell.com
S: ha.us.service@honeywell.com
P: ha.ap.service@honeywell.com

www.honeywellanalytics.com
www.raesystems.com

www.honeywellanalytics.com
www.raesystems.com
13496_H_Touchpoint Plus_DS01157_V2_EMEA
03/16

Honeywell Analytics
2016 Honeywell Analytics

xperts in Gas
Please Note:Detection
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or
omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued
ease Note: regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
e every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or
ssions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently
ed regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.

S-ar putea să vă placă și