Documente Academic
Documente Profesional
Documente Cultură
Approved By
Accepted By
Name Company Date
Website: www.litekabel.com
E-mail: info@litekabel.com
Certificate SG02/56058 Certificate GB00/18475 Certificate MY05/0009/OHS
1. Environmental Conditions:
1.1 Temperature:
o
Operating -20 to 70 C
o
Installation 0 to 60 C
Storage -20 to 70 oC
1.2 Humidity:
Operating Up to 100 % non condensing
Installation Up to 100 % non condensing
Storage Up to 100 % non condensing
2. Cable Structure:
2.1 Fibre Construction:
(ITU-T G.652D Standard Single Mode Fibre)
ITEM VALUE
Type of Fibre Single Mode, Step Index
Maximum Attenuation at 1310 nm 0.35 dB/km
Maximum Attenuation at 1550 nm 0.22 dB/km
Mode Field Diameter at 1310 nm 9.2 m 0.4m
Mode Field Diameter at 1550 nm 10.4 m 0.8m
Cable Cut-off Wavelength 1260 nm
Cladding Diameter 125. 0 1.0 m
Core-Clad Concentricity 0.5 m
Cladding Non-Circularity 1. 0 %
Coating Diameter 245 5 m
Coating-Cladding Concentricity < 12 m
ps
1288-1339 nm Chromatic Dispersion 3.5 /nm * km
ps
1550 nm Chromatic Dispersion 18 /nm * km
Zero Dispersion Slope <0.092 ps/nm2 *km
Zero Dispersion Wavelength 1301.5 to 1321.5 nm
Proof Test Strain Level 1%
Website: www.litekabel.com
E-mail: info@litekabel.com
Certificate SG02/56058 Certificate GB00/18475 Certificate MY05/0009/OHS
Website: www.litekabel.com
E-mail: info@litekabel.com
Certificate SG02/56058 Certificate GB00/18475 Certificate MY05/0009/OHS
Outer PE Sheath
Corrugated Steel Ta pe
Water Blocking Tape
Inner PE Sheath
Core Wrap
Therm oplastic Tubes
Colour Coded Fibres
Filling Gel
Central Strength Member
Filler Rod
Flooding Compound
Rip Cord
Repeated IEC 794-1-E6 Cable specimen shall be repeatedly Power loss after
Bend bent with a frequency of 25 cycles at a loading shall not
rate of 30 cycles per minute on a be more that 0.1
mandrel radius of approximately 15 dB
times cable outer diameter.
Crush IEC 794-1-E3 The load is 3000 N with the dimension Power loss after
of plate of 100 mm times 100 mm loading shall not
be more that 0.1
dB
Repeated IEC 794-1-E4 The radius of hammerhead is 12.5 mm. Power loss after
Impact Test The hammer shall be drop for 20 times loading shall not
from 150-mm height and the weight be more than 0.1
shall be determined by cable outer dB
diameter. Refer to Table B attached.
Note: The Mechanical Tests will only performed as per customer requirement.
Website: www.litekabel.com
E-mail: info@litekabel.com
Certificate SG02/56058 Certificate GB00/18475 Certificate MY05/0009/OHS
TABLE B: of Hammer Head Mass and Impact Energy (for 150 mm drop)
Website: www.litekabel.com
E-mail: info@litekabel.com