Part Number:
SUBMITTAL MicroMetl Power Exhaust Option
FORM NO. PECD-SRT34TA-2W1 DATE: 09 / 14
Configuration PECD-SRT34TA- Series
Performance and Sound Data
SUBMITTED TO
COMPANY:
DRAWN BY: M. M.
JOB NAME:
EQUIPMENT:
NOTES:
Low Static.
Medium Static.
High Static.
Pg. 3 of 4
THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT.
MANUFACTURER RESERVES THE RIGHT TO DISCONTINUE, OR CHANGE AT ANYTIME, SPECIFICATIONS & DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS. COPYRIGHT MICROMETL CORPORATION 2014. ALL RIGHTS RESERVED.
MICROMETL CORPORATION 3035 N. SHADELAND AVENUE, SUITE 300 INDIANAPOLIS, IN. 46226 1-800-662-4822 MICROMETL WEST 905 SOUTHERN WAY. SPARKS, NV 89431 1-800-884-4662
Part Number:
SUBMITTAL MicroMetl Low Leak Power Exhaust and Economizer Combinations
for Carrier 48/50 TC 04 - 16, 50 TCQ 04 - 14, 48/50 HC 04 - 14,
FORM NO. PECD-SRT34TA-2W1 DATE: 09 / 14
50 HCQ 04 - 12, 48/50 LC 04-12 Units Part Number Scheme
SUBMITTED TO
COMPANY:
DRAWN BY: M. M.
JOB NAME:
Not all options, configurations, controls, or product types, Power Exhaust total HP :
H - 1/2 HP Belt Driven
PART NUMBER - P E C D - S R T 1 2 T A - D J D 0 - 2 V 1 0
Product Type: Special Options (Not used if not needed):
Power Exhaust and Economizer- PE S - Smoke Detector (future)
F - O/A Flow Monitoring (Greentrol)
Exhaust Type: M - Motorized relief (3 cfm/sqft @ 1" static)
Propeller - P * - Future Options
Centrifugal - C Power Exhaust Operation:
Permanent Magnet - E V - Constant Volume
Backward Incline - B M - Modulating
Economizer Type: Voltage:
Downflow - D 1 - 208/230V/1PH
Horizontal Internal - H 2 - 208/230V/3PH
Convertable (through the end) - C 4 - 460V/3PH
Horizontal External Panel Mounted - E 5 - 475V/3PH
External Horizontal Mixing Box - M
Actuator Type:
Carrier Unit: H - Honeywell
Small Roof Top - SRT B - Belimo
Medium Roof Top - MRT S - Siemens
Chassis Size:
Sensors:
Chassis 1 and 2 - 12
D - Adjustable Dry Bulb
Chassis 2 Special Low Static - S2
E - Enthalpy
Chassis 3 and 4 - 34
X - Differential Dry Bulb
Chassis 4 Special Low Static - S4
Z - Differential Enthalpy
Chassis 5 - 05
0 - No Sensor
Combo. Package not available. Economizer and Exhaust ordered separately. Chassis 6 and 7 - 67
Combo. Package not available. Economizer and Exhaust ordered separately. Chassis 8 and 9 - 89 Logic Controls:
53
J - Jade Single Speed Indoor Fan
Compliance: 3 2 - Jade 2 Speed Indoor Fan
Damper Leakage,Title 24 - 2013, and AHRAE 90.1 - 2010 - T 1 4 3 B - Zip Base Module Only, Single or 2 Speed Indoor Fan
Damper Leakage Washington State Energy Code - 2012 - W 2 3 Y - Zip Base and Energy Module 1 or 2 Speed Indoor Fan
Revision Level: 3 X - Zip Base and Energy Module 2 Speed Indoor Fan
First Level - A 0 - No Controls
Format:
Notes:
D - Distribution
1
Economizers meet Title 24, 2013, Prescriptive Section 140.4(e)4(a, b, c, and h), d, e, f, and g when supplied with Note 3 controls, and
ASHRAE Standard 90.1-2010, Table 6.4.3.4.4 requirements.
5 year parts and componenets warranty. Damper reliability and leakage. Relief. Sensor setpoint, reliability, calibration, and high limit.
2
Economizers meet Wasington State Energy Code, Commercial - 2012, Section C402.4.5.2, Exception 4 for Unitary Packaged Equipment.
Motorized damper leakage.
3
Economizers meet Title 24, 2013, Mandatory Section 120.2 Economizer fault and detection diagnostic requirements.
4
Optional Energy Module required for use with CO2, Power Exhaust, or non-integrated heat pump systems.
5
Only used with non- current models. Current models TC, TCQ, HC, HCQ, LC use 2 - Jade 2 speed indoor fan option, even with 1 speed units.