Sunteți pe pagina 1din 9

Report No: 67117-050093

Date: 5/12/2017
Page: Page 1 of 9
Lab Location: USA

This Test Report is used by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issue defined therein.
The results shown is this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company.

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 2 of 9
Lab Location: USA

Applicant: Cascadia Seller Solutions OV ERA L L RA T I N G


Contact: Susanne King, Martha Evans
PASS
Address: 14525 18th Pl W, Lynnwood, WA 98087
FAIL X
TEL : (206) 202-0222 FAX: /
compliance-team@thinkcascadia.com,
E-mail: martha.evans@thinkcascadia.com,
Susanne.king@thinkcascadia.com
Copy To: accounting@thinkcascadia.com

Sample Information
Product Description: Coffee and Spice Grinder
Purchase Order Number: 170508-TRF-KLEIN No. of Sample Submitted: 3
Manufacturer: / Country of Destination: USA
Country of Origin: China Color: Black

Testing Status
Pre-production Production Retest Previous Report No.:
Other/ Comments: NA

For and on behalf of


Modern Testing Services, LLC

John Gerringer Technical Director


Operations

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 3 of 9
Lab Location: USA

TEST RESULT SUMMARY


Labeling F
Construction Qualities P
Performance P
Labeling mismatch between the wattage shown on two of the boxes vs the wattage on the motor label, and
missing labeling on the box such as, Household Use Only , Household Type , and the like per UL 982
Section 67.

Note : P = Meet Customers Requirement F = Below Customers Requirement


# = See Report For Test Data - = Did Not Perform
N/A = Not Applicable * = See Remark

Packaging, Front/Back Packaging, Side 1 Packaging, Side 2

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 4 of 9
Lab Location: USA

Packaging, Top Incorrect Wattage label Correct Wattage label

Warning Label on the Front of the


Samples
Bottom of Sample, Showing Label

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 5 of 9
Lab Location: USA

Sample

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 6 of 9
Lab Location: USA

MODERN TESTING SERVICES TEST PROTOCOL

SUMMARY OF TEST RESULTS FOR


Motor Operated Household Food Preparing Machines EL-813-US (abbreviated)
(UL 982 Light Safety Audit)
Client Code: BO1I20TMGC Technician: Bob Garber MTS Report Number: 67117-050093
Start Date: 05/10/2017 Finish Date: 5/19/2017 Result Reviewed by:

TEST CODE TESTED PROPERTY REQUIREMENT RESULTS COMMENTS


Pass Fail
LABELING
UL 982 6th Ed Markings General Shall be plainly / permanently marked Labeling complies with
Section 65 where readily visible with: standard, however, two
a) Manufacturers name of the boxes (200 Watts)
b) Date of manufacture
vs the wattage on the
c) Catalog number or equivalent X motor label (250 Watts),
d) Electrical rating including voltage,
frequency, input amperes or watts the third box showed the
correct wattage (250
Watts)
UL 982 6th Ed Markings Cautionary - Shall be marked per Section depending on
Section 66 General type of appliance i.e. mixer, blending mixer, X
knife, shredder, slicer, juicer, etc.
UL 982 6th Ed Section Marking Carton A carton (individual marketing container) for
67 an appliance shall be marked to indicate
that the product is intended for household
type usage, such as, Household Use X
Only, Household Type, and the like per
Section. Not marked
UL 982 6th Ed Instruction Manual - General An Instruction Manual or the equivalent
Section 68 shall be provided with the appliance. The
manual shall specifically warn the user
against each potential risk of fire, electric
shock, and injury to persons; and state the
precautions that should be taken to guard
against that condition. The safety X
instructions shall be a permanent part of the
manual but separated in format from the
other instructions, and shall appear before
the operating instructions in the manual per
section.

UL 982 6th Ed Instruction Manual All Important safeguard information shall be


Section 69 Appliances included in the instruction manual for all X
appliances per Section.
UL 982 6th Ed Instruction Manual Product Shall be marked per Section depending on
Section 70 Specific type of appliance i.e. mixer, blending mixer, X
knife, shredder, slicer, juicer, etc.

UL 982 6th Ed Instruction Manual User Shall include instructions and caution
Section 71 Maintenance statements for cleaning and user X
maintenance.
UL 982 6th Ed Instruction Manual Mounting Per Section.
Section 72 Instructions - N/A
UL 982 6th Ed Instruction Manual Outdoor Shall include grounding instructions and
Section 73 Use extension cords. - N/A

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 7 of 9
Lab Location: USA

UL 982 6th Ed Section Instruction Manual Power Appliances provided with a 2 wire polarized
74 Plug Polarization attachment plug shall provide guidance in
instruction manual pertaining to polarized X
plug.

CONSTRUCTION QUALITIES
UL 982 6th Ed General Shall be well-designed using materials
Section 6 suitable for end use. X
UL 982 6th Ed Frame and Enclosure Shall be of sufficient strength to withstand
Section 7 impact and heat.
Shall enclose moving parts, except for
those which need to be exposed to perform
their intended function. X
Shall provide protection against
unintentional contact with uninsulated live
parts.

UL 982 6th Ed Power Supply Connections Cord shall be of appropriate length (no less
Section 11.1 Cord Connected Cords and than 2 feet depending on application), type,
Plugs and current capacity per section. Polarity X
shall be appropriate.
UL 982 6th Ed Section Switches Ratings / Labeling Shall be appropriate for application and
17.1-17.6 have suitable current and voltage ratings
per Section. If, when energized, an
appliance has moving parts that are likely to
cause injury to persons, a motor control
switch, other than a momentary-contact X
switch, on the appliance shall have a plainly
identified OFF position, or ON and OFF
positions and be marked per Section as
applicable.
UL 982 6th Ed Switches With Motors More If a portable appliance employs a motor
Section 17.7-17.8 Than 1/3 Horsepower rated at more than 1/3 horsepower, a
motor-control switch for the motor shall be X
provided in the appliance. An appliance
shall not employ a through-cord switch.

UL 982 6th Ed Grounding - Required The following types of appliances shall


Section 20.1 have provision for grounding:
a) An appliance for use in damp or wet
locations;
b) An appliance intended for outdoor use;
c) An appliance intended to be used on a X
circuit operating at more than 150 V to
ground; and
d) An appliance intended for permanent
connection to the supply source.

UL 982 6th Ed Protection Against Personnel Shall have no sharp edges and shall
Section 22 Injury enclose all moving parts that may cause
injury. Attachments, guards, interlocks, and
stability shall be per Section. X

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 8 of 9
Lab Location: USA

UL 982 6th Ed Attachments The literature accompanying a package


Section 23 containing a basic appliance and various
attachments intended to be marketed as a
complete unit shall indicate what
attachments are intended for use with the
basic appliance.
If an attachment is packaged and marketed
separately from the basic appliance and
recommended for use with it by the
manufacturer of the basic appliance, it shall
have an assigned catalog number (or
equivalent).
-
Also, information packaged with the basic
appliance shall Identify by catalog number,
series number, or the like, the attachments
which are intended for use with the basic
appliance. Those numbers shall appear at
the following locations:
a) On the package housing the attachment;
and
b) On information material furnished with
the attachment or on the attachment itself.
N/A
UL 982 6th Ed Stability Shall be configured to its most unfavorable
Section 25 mode, tested in all possible positions that
might typically be encountered and tilted to X
an angle of 10 degrees per Section.

UL 982 6th Ed Guards Evaluate configuration and effectiveness


Section 27 per Section. Report discrepant conditions. X
UL 982 6th Ed Switches, Controls, Interlocks Evaluate and report discrepancies per
Section 28 Section. X
PERFORMANCE
UL 982 6th Ed Input Test When operated with highest current draw
Section 35 conditions, shall be at rated current or X
power within allowable deviation.

UL 982 6th Ed Dielectric Voltage Withstand An appliance shall be capable of


Section 37 withstanding for 1 minute without an
indication of unacceptable performance the
application of a potential applied per
Section:

a) 1000 V for an appliance employing a


motor rated at 1/2 horsepower or less.
b) 1000 V plus twice the rated voltage for
an appliance employing a motor rated at
more than 1/2 horsepower.
X
c) 1000 V, or 1000 V plus the rated voltage
(depending upon the value of the test
potential applied to the appliance as a
whole), between the terminals of a
capacitor used for electromagnetic
interference (EMI) reduction or arc
suppression.
d) 2500 V for an electric knife.

UL 982 6th Ed Strain Relief Shall withstand 35 lbf applied for 1 minute
Section 54.1 54.2 with the connections within the appliance X
disconnected..

Functionality Shall function as intended as received


X

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia
Report No: 67117-050093
Date: 5/12/2017
Page: Page 9 of 9
Lab Location: USA

The samples were subjected to several cycles of normal use as directed in instruction manual (10 seconds), as well use
to the labelled maximum 20 second interval, and allowing to cool for 60 seconds, and repeating for 10 cycles, samples
performed as expected with no problems noted.

There was a labeling mismatch between the wattage shown on two of the boxes (200 Watts) vs the wattage on the motor
label (250 Watts), the third box showed the correct wattage (250 Watts). There is also missing labeling on the box such as,
Household Use Only, Household Type, and the like per UL 982 Section 67.

****End of Test Report****

NOTE:
If there is question or concern regarding the above results, please contact us via email bob.garber@mtsus.com

Modern Testing Services, LLC Tel: 1-508-638-1793 Fax: 1-508-638-1759


349 Lenox Street Email: Info@ModernTestingServices.com
Norwood, MA 02062 Website: www.ModernTestingServices.com

USA Ger many UK Turkey China Hong K ong Taiwan Bangladesh Cambodia I ndia Thailand K or ea I ndonesia Pakistan Vietnam Egypt Australia

S-ar putea să vă placă și