NSCP2015SEISMICANALYSIS(STATICFORCEPROCEDURE)
BuildingData: SeismicFactors:
#suspendedfloors 5 ImportanceFactor,I 1 NSCP2015Section208.4.2(Table2081)
Floor wh Forceattopduetowhiplasheffect
w(kN) h(m) F(kN)
level (kNm) forT0.7 0
5 4802.6 15.5 74440.3 1717.11 for0.7<T<3.6 0.07TV= 129.66 Ft= 0 kN
4 4802.6 12.4 59552.2 1373.69 forT3.6 0.25V= 1214.72
3 4321.4 9.3 40189 927.04
2 3602.7 6.2 22336.7 515.24
1 4556.6 3.1 14125.5 325.83 VerticalDistributionofforces:
0 0 0 0 0.00
1 0 0 0 0.00 Leveln Fn
2 0 0 0 0.00 Level8 F8
3 0 0 0 0.00 Level7 F7
4 0 0 0 0.00 Level6 F6
5 0 0 0 0.00 Level5 F5 1717.11 kN
6 0 0 0 0.00 Level4 F4 1373.69 kN
7 0 0 0 0 Level3 F3 927.04 kN
8 0 0 0 0 Level2 F2 515.24 kN
9 0 0 0 0 Level1 F1 325.83 kN
10 0 0 0 0
11 0 0 0 0
12 0 0 0 0 *n=uppermostlevel(forn>8)
13 0 0 0 0 *Level1isthefirstsuspendedfloorabovetheground
14 0 0 0 0 *References: NationalStructuralCodeofthePhilippines2015
= 22085.9 210643.8 UniformBuildingCode(UBC)1997
*Programmedby:KevinSaluague(kevinsaluague09@gmail.com) WindandEarthquakeResistantBuildingsbyTaranath,Bungale