Sunteți pe pagina 1din 9

Debutanizer Bottoms to Debutanizer Debutanizer Bottoms to

Cooling Water Supply/ Return Bottom


Tankage in Case of NHT SD Cooler Tankage in Case of NHT SD
Serial No. 411-E10A/B Temperature
Flow Temperature In/Out Flow Temperature In/Out Flow
Heat Duty In/Out
m3/hr o
C m3/hr o
C Mkcal/hr m3/hr o
C
Cooling Water Flow ~ 667m3/hr Cooling Wat
1 200 128 37.41 667 34.5 44.57 -6.92 200 128
2 210 128 37.80 667 34.5 45.04 -7.24 220 128
3 220 128 38.19 667 34.5 45.49 -7.55 230 128
4 230 128 38.61 667 34.5 45.94 -7.86 240 128
5 240 128 39.05 667 34.5 46.39 -8.17 250 128
6 250 128 39.48 667 34.5 46.83 -8.47 200 130
7 200 130 37.48 667 34.5 44.81 -7.08 210 130
8 210 130 37.87 667 34.5 45.29 -7.41 230 130
9 220 130 38.28 667 34.5 45.76 -7.73 250 130
10 230 130 38.71 667 34.5 46.22 -8.05 200 132
11 200 132 37.56 667 34.5 45.06 -7.25 220 132
12 210 132 37.95 667 34.5 45.54 -7.58 250 132
13 200 135 37.66 667 34.5 45.42 -7.50 200 135
14 220 135 38.53 667 34.5 46.42 -8.19 230 135
15 240 135 39.44 667 34.5 47.39 -8.86 250 135
tanizer Bottoms to Cooling Water Supply/ Return Debutanizer
e in Case of NHT SD Bottom Cooler
Temperature 411-E10A/B
Flow Temperature In/Out
In/Out Heat Duty
o
C m3/hr o
C Mkcal/hr
Cooling Water Flow ~ 700m3/hr
37.31 700 34.5 44.12 -6.93
38.07 700 34.5 45.01 -7.56
38.48 700 34.5 45.44 -7.87
38.92 700 34.5 45.86 -8.18
39.34 700 34.5 46.29 -8.48
37.38 700 34.5 44.35 -7.09
37.77 700 34.5 44.81 -7.42
38.58 700 34.5 45.70 -8.06
39.45 700 34.5 46.57 -8.69
37.45 700 34.5 44.58 -7.26
38.25 700 34.5 45.51 -7.92
39.57 700 34.5 46.85 -8.89
37.55 700 34.5 44.93 -7.51
38.83 700 34.5 46.36 -8.53
39.75 700 34.5 47.28 -9.20
Performance Evaulation of 411-E10A/B at CW Flow 667m3/hr
49.00

47.39
47.00 46.83
46.42 46.39
46.22
45.94
45.76
45.42 45.54 45.49
45.29
45.00 45.06 45.04
44.81
44.57

43.00

41.00

39.44 39.48
39.00 39.05
38.71
38.61
38.53
38.28
38.19
37.95
37.87
37.80
37.66
37.56
37.48
37.41
37.00

35.00
190 200 210 220 230 240 250 260

Debutanizer Bottoms to Tankage in case of NHT Shutdown Flow Rate 411-FIC058 m3/hr

At 128C 411TI057 At 128C CWR At 130C 411TI057 At 130C CWR


At 132C 411TI057 At 132C CWR At 135C 411TI057 At 135C CWR
Performance Evaulation of 411-E10A/B at CW Flow 700m3/hr
0.00

49.00
-2.00

47.28
47.00 46.85 -4.00
46.57
46.36 5
45.70 4
45.51 3 -6.00
45.00 44.93
-6.93 44.81 2
-7.09
44.58
-7.51
44.35 -7.42 -7.56
1 -7.87
-8.06 -8.00
-8.18
-8.53 -8.48
-8.69
43.00 -9.20
-10.00

41.00 -12.00

39.75
39.57
39.45
39.34 -14.00
39.00 38.83 38.92
38.58
38.48
38.25
38.07 -16.00
37.77
37.55
37.45
37.38
37.31
37.00
-18.00

35.00 -20.00
190 200 210 220 230 240 250 260

Debutanizer Bottoms to Tankage in case of NHT Shutdown Flow Rate 411-FIC058 m3/hr

At 128C 411TI057 At 128C CWR At 130C 411TI057 At 130C CWR At 132C 411TI057 At 132C CWR
At 132C 411TI057 At 132C CWR At 128C Duty At 130C Duty At 132C Duty